1. |
Design characteristics for drug nebulizers |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 63-68
DennisJ. H.,
HendrickD. J.,
Preview
|
PDF (616KB)
|
|
摘要:
Drug nebulizers should be designed to produce an aerosol which efficiently targets drug to the respiratory tract. In this article we review the basic principles of aerosol generation from both jet and ultrasonic nebulizers, and the factors governing respiratory tract penetration and deposition. We review methods for accurate measurement of aerosol dose and size, with emphasis on evaporative effects and the implications to drug nebulizer design. We identify three forms of drug aerosol waste attributable to: generation of non-respirable aerosol, losses to the environment, and dead volume solution; and we consider how each may be minimized through good nebulizer design. Finally, we compare the relative merits of jet and ultrasonic nebulizers, and conclude by predicting a new trend in future drug nebulizer therapy.
ISSN:0309-1902
DOI:10.3109/03091909209021962
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
2. |
Interference problems and screening in NMR and MRI |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 69-78
TimmsW. E.,
Preview
|
PDF (828KB)
|
|
摘要:
A pragmatic approach to interference in NMR and MRI systems is presented with the objective of raising the awareness of problems associated with larger installations. The basic premise is that an installation is a system composed of interconnected sub-systems, each with its own idiosyncracies. Consequently all problems should be considered from this view-point. Practical warnings and solutions are given along with simple mathematical equations to permit one to calculate some interference effects. Most problems are associated with RF and gradient sub-systems, so the main content deals with degradation of the NMR signal by noise and coherent RF interference and with the interaction of sub-systems. Attention is drawn to the correct identification of the source of a problem, and the importance of a well engineered solution.‘Quick-fix repairs’can lead to very baffling problems when the system is reconfigured for a different experiment.
ISSN:0309-1902
DOI:10.3109/03091909209021963
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
3. |
Biparietal diameter: an alternative measure of head growth in the low-birthweight infant |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 79-81
TiroshE.,
WeingerM. A.,
BergerA.,
CohenA.,
Preview
|
PDF (318KB)
|
|
摘要:
Reliability and validity of biparietal diameter (BPD) compared with head circumference (HC) measurement as an index of cranial growth was assessed. A significant correlation between BPD and HC (r = 0.857; p<0.0001) and an interobserver reliability of 92% were found. Infants' age and sex had independent effects on BPD growth rale. Very sick infants had a lower increase in BPD rate than healthy controls. It is suggested that in sick premature infants, when the head is encumbered by various types of apparatus, this technique might prove more feasible than HC measurement.
ISSN:0309-1902
DOI:10.3109/03091909209021964
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
4. |
Portable maximum respiratory pressure measurement—A comparison with laboratory techniques |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 82-86
CarrollN.,
ClagueJ. E.,
PollardM. H.,
HoranM. A.,
EdwardsR. H. T.,
CalverleyP. M. A.,
Preview
|
PDF (551KB)
|
|
摘要:
We have evaluated a new, hand-held, electronic device to measure maximal respiratory pressures, and compared its performance in normal subjects against two pre-existing methods. This new device produces accurate, reproducible results and has the advantages of easy use and portability, which allow it to be used at the patient's bedside, outpatient clinic or pulmonary function laboratory.
ISSN:0309-1902
DOI:10.3109/03091909209021965
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
5. |
Calendar |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 87-88
Preview
|
PDF (172KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909209021966
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
6. |
Selected contents |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 89-94
Preview
|
PDF (684KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909209021967
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
7. |
Evaluation |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 95-98
Preview
|
PDF (443KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909209021968
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
8. |
News, trends&techniques |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 99-102
Preview
|
PDF (416KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909209021969
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
9. |
New Products |
|
Journal of Medical Engineering&Technology,
Volume 16,
Issue 2,
1992,
Page 103-106
Preview
|
PDF (744KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909209021970
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
|