1. |
A microcomputer-based system for the accurate continuous measurement of ventilation and blood pressure parameters under anaesthesia |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 5,
1989,
Page 243-251
TooleyM. A.,
O'ConnorS. A.,
WilkinxsonD. J.,
Preview
|
PDF (959KB)
|
|
摘要:
A microcomputer system for the measurement of parameters of ventilation and blood pressure in the spontaneously breathing anaesthetized patient is described. The system continuously calculates minute volume, respiratory frequency, and mean end tidal carbon dioxide concentration. Additionally four cardiovascular parameters are measured. The inputs are obtained from a wet-wedge spirometer, a capnograph and a blood pressure monitor. The methods of computer calculation are described in detail. The computer-generated results are compared with those obtained by manual calculation. The system described has the capacity to record and display a wide variety of further measurements made during anaesthesia. This system provides invaluable information for research and teaching, but may also be useful during routine anaesthesia.
ISSN:0309-1902
DOI:10.3109/03091908909033163
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
2. |
Remote Control Systems' Radiotelemetry Receiver 7060: its use in clinical colonic motility measurement |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 5,
1989,
Page 252-256
ThorburnHeather A.,
CarterKenneth B.,
GoldbergJacqueline A.,
FinlayIan G.,
Preview
|
PDF (856KB)
|
|
摘要:
A new radiotelemetry receiver type 7060 for use with radiopills is described. Its performance under laboratory conditions was assessed and its use for clinical colonic pressure measurements evaluated. The receiver, which resembles a small microcomputer, was easy to set up and worked reasonably well under ward conditions. Difficulties were experienced with the belt aerial supplied with the receiver, which did not reliably pick up signals from a freely moving radiopill. The receiver is not suitable for ambulatory applications. Its main clinical use is in situations where frequent sampling of the radiopill's signal over a long period of time is essential (e.g. colonic pressures). The large quantity of data generated can be fed from the receiver's analogue or digital output on line to a recorder.
ISSN:0309-1902
DOI:10.3109/03091908909033164
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
3. |
Evaluation report: ECG recorders |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 5,
1989,
Page 257-265
Preview
|
PDF (825KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908909033165
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
4. |
Correspondence |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 5,
1989,
Page 266-267
RowanD.,
ShawA.,
Preview
|
PDF (204KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908909033166
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
5. |
Book reviews |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 5,
1989,
Page 267-268
Preview
|
PDF (190KB)
|
|
摘要:
Fetal Monitoring M. J. Whittle. Baillière Tindall, UK. ISBN 0-7020-1221-1. 222 pages. 1987. Price£15.Microcomputers and Physiological Simulation J. E. Randall, Raven Press, U.S.A. ISBN 0-88167-292-0. 303 pages 1987. 2nd edition. Price $49.50.
ISSN:0309-1902
DOI:10.3109/03091908909033167
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
6. |
dti TechAlert |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 5,
1989,
Page 271-272
Preview
|
PDF (205KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908909033168
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
|