|
1. |
Assay of Clotting Factors in Outdated Blood Bank Plasma and Its Potential Use for Therapy in Hemophilia and Other Hemorrhagic Dyscrasias |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 289-292
Robert L. Rosenthal,
Esther Sloan,
Preview
|
PDF (291KB)
|
|
摘要:
Assays of several clotting factors were performed on outdated, plastic bag blood bank plasma 25 to 36 days old, and after four more months of storage of aliquots at 4C and –20 C. Levels of PTC, PTA, Factor VII and prothrombin were almost consistently found to be above 70 per cent. Factor V levels were generally below 30 per cent, especially after four months of storage. AHG levels averaged 56 per cent and 34 per cent of outdated plasmas were above 70 per cent. No further deterioration occurred after four months at –20 C. These findings suggest that outdated blood bank plasmas screened for satisfactory AHG levels may be used directly for therapy or as a source of concentrated AHG fractions. Outdated plasma may be utilized without screening of clotting factor activity for replacement of PTC, PTA, Factor VII and prothrom
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04741.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
2. |
Plasmapheresis of the Patient as a Method for Achieving Effective Levels of Plasma Coagulation Factors Using Fresh Frozen Plasma* |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 293-301
Herbert A. Perkins,
Preview
|
PDF (652KB)
|
|
摘要:
Levels of clotting factors compatible with normal hemostasis can be achieved in the plasma of patients with severe congenital deficiencies by transfusion of large amounts of fresh frozen plasma after prior reduction of the plasma volume of the patient by plasmapheresis. The procedure is a potential source of serious complications; close observation of the patient and observance of recommended precautions are necessary. The technic should be useful in emergency situations when AHF concentrates are not available and routine plasma transfusions are inadequate.
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04742.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
3. |
Transfusion of Platelet Concentrates Prepared from Acidified Platelet‐Rich Plasma* |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 302-307
John A. Shively,
Margaret P. Sullivan,
Jiau S. Chiu,
Preview
|
PDF (403KB)
|
|
摘要:
With the use of Aster's and excess ACD solutions, the recovery of chromium51‐labeled platelets was greater, and the sequestration phenomenon decreased in patients without hematologic disease, compared with preparations collected in the normal amounts of ACD as the anticoagulant. Analysis of platelet counts following transfusions of platelet concentrates demonstrated a significant increase of platelets in transfused leukemic patients using acidified preparations as compared with those collected in normal amounts of ACD. The use of additional ACD solution which is routinely available in the blood bank appears to be a satisfactory method to prepare the acidified platelet concentrate
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04743.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
4. |
Platelet Concentrates from Acidified Plasma |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 308-309
Wanda S. Chappell,
Preview
|
PDF (114KB)
|
|
摘要:
A method is described which takes advantage of the calculated 16 per cent excess of ACD‐A anticoagulant in routine blood collection in order to lower the pH of Platelet‐Rich Plasma. This permits the preparation of unaggregated Platelet Concentrates in a closed system without additi
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04744.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
5. |
The Third Example of Anti‐Doa |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 310-310
Catherine H. Williams,
Mary N. Crawford,
Preview
|
PDF (58KB)
|
|
摘要:
A third example of anti‐Doais reporte
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04745.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
6. |
Human‐Type Blood Factors in Gibbons, with Special Reference to the Multiplicity of Serological Specificities of Human Type M Blood |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 311-318
Alexander S. Wiener,
J. Moor‐Jankowski,
E. B. Gordon,
A. J. Riopelle,
W. F. Shell,
Preview
|
PDF (551KB)
|
|
摘要:
The human‐type blood groups of 20 gibbons of subspeciesHylobates lar larand of four gibbons of subspeciesHylobates lar pileatushave been determined. Differences in distribution of the ABO blood groups and MN types were observed for the two subspecies, but all 24 gibbons were of Rh‐Hr type RhGi. All the animals also lack both factors I and i. By absorption experiments anti‐M reagents were shown to contain antibodies of at least three distinct M specificities; one M specificity is shared by all gibbon red cells, a second is absent from all gibbon red cells, while a third is shared only by gibbons red cells of type (M)Giand type (MN)Gi. The theoretical and practical significance of the multiplicity of M factors in human M blood are pointe
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04746.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
7. |
Blood Group, Serum Genetic Factors, and Hemoglobins in Cook Islanders |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 319-323
R. Douglas,
J. Jacobs,
D. D. McCarthy,
J. M. Staveley,
Preview
|
PDF (336KB)
|
|
摘要:
The blood groups, the haptoglobin and transferrin types, together with the Gm2groups and hemoglobins of 100 unrelated Cook Islanders in Atiu Island are recorded.The absence of the B gene, the low frequency of S, the high frequency of non‐secretors, the absence of K and the high Hpl level together with the absence of hemoglobin variants are features of the peoples of the South West Pacific, particularly Eastern Polynesi
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04747.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
8. |
Blood Group, Serum Genetic Factors, and Hemoglobins in Cook Islanders |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 324-326
R. Douglas,
J. Jacobs,
D. D. McCarthy,
J. M. Staveley,
Preview
|
PDF (180KB)
|
|
摘要:
The ABO, MN, Lewis and Rh types, together with the Gm3groups, haptoglobin, transferrin and hemoglobin types of 323 Rarotongans are recorded.
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04748.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
9. |
Anti‐M in Neoplastic Diseases |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 327-327
O. Vetter,
H. Wegner,
Preview
|
PDF (81KB)
|
|
摘要:
The association of anti‐M and neoplastic disease could not be confirmed. On the other hand 17 examples of anti‐M, not associated with neoplasms, were encountered in 40,000 blood samp
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04749.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
10. |
The Evaluation of a Rapid Card Technic for ABO and Rho(D) Typing |
|
Transfusion,
Volume 6,
Issue 4,
1966,
Page 328-330
Bernice H. Cohen,
Samuel E. Press,
Preview
|
PDF (244KB)
|
|
摘要:
A simple card technic using seven drops of finger blood for rapid ABO and Rho(D) typing was compared with the standard typing methods of the JHH Blood Bank laboratory. When performed according to instructions, the card test showed distinct, easily readable reactions that were in excellent agreement with the results obtained by the standard method. Therefore, where Rh sub‐grouping is not required, or is to be carried out subsequently on all “Rho(D) negative” subjects, this card technic provides a useful, simple procedure suitable for field studies and all types of mass screening, since venipunctures are unnecessary, classification is rapid, and a permanent record avai
ISSN:0041-1132
DOI:10.1111/j.1537-2995.1966.tb04750.x
出版商:Blackwell Publishing Ltd
年代:1966
数据来源: WILEY
|
|