11. |
Differential Pressure Gauge for Use with Liquids and Corrosive Fluids |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 869-870
H. E. Flotow,
B. M. Abraham,
R. D. Carlson,
Preview
|
PDF (147KB)
|
|
摘要:
A sensitive, rugged pressure gauge is described that was developed to determine the density (composition) and the viscous pressure loss in flowing streams of UO2‐NaK slurries. The differential pressure sensors are two metal bellows that are rigidly connected in opposition, the net displacement of which is detected by a linear variable differential transformer. The sensitivity of the unit is 0.05 mm Hg pressure and the range is 100 mm Hg with an accuracy of ±0.4%. By simply inserting various calibrated springs in the instrument it is possible to increase or decrease the range and maintain the sensitivity at 0.05% of the range.
ISSN:0034-6748
DOI:10.1063/1.1716024
出版商:AIP
年代:1958
数据来源: AIP
|
12. |
Theoretical Analysis of Ultrahigh Vacuum Condensers |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 871-873
William R. Mickelsen,
J. Howard Childs,
Preview
|
PDF (172KB)
|
|
摘要:
The analysis considers the condensation of high‐velocity molecular beams on condenser surfaces having very low temperatures. The condenser surface area and volume necessary to maintain a given vacuum are derived theoretically from a highly idealized model.
ISSN:0034-6748
DOI:10.1063/1.1716025
出版商:AIP
年代:1958
数据来源: AIP
|
13. |
30‐Inch Propane Bubble Chamber |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 874-879
Wilson M. Powell,
William B. Fowler,
Larry O. Oswald,
Preview
|
PDF (505KB)
|
|
摘要:
A propane bubble chamber with a sensitive volume of 30½ in. by 21½ in. by 6½ in. deep operating in a magnetic field of 14 000 gauss is described. Operating parameters and some engineering details are given. The part of the chamber containing the propane is hydrostatically supported in oil through which the chamber is photographed. This permits the use of small glass windows with a large safety factor.
ISSN:0034-6748
DOI:10.1063/1.1716026
出版商:AIP
年代:1958
数据来源: AIP
|
14. |
Magnetic Spectrometer for 450‐Mev Protons |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 880-884
A. V. Crewe,
Preview
|
PDF (291KB)
|
|
摘要:
A 60° wedge‐focusing magnetic spectrometer has been built for use with the 450‐Mev proton beam of the Chicago synchrocyclotron. It has curved pole edges to produce good focusing in one plane only. The minimum line width obtainable is ∼¼% with an available solid angle of ∼1/2000 sterad. The deflection is vertical, and angular distributions can be measured from 7° to 173° without allowing the primary beam to strike the magnet yoke.
ISSN:0034-6748
DOI:10.1063/1.1716027
出版商:AIP
年代:1958
数据来源: AIP
|
15. |
Combined Magnetic Spectrograph and Spectrometer |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 885-888
Harald A. Enge,
Preview
|
PDF (259KB)
|
|
摘要:
A combination instrument is proposed in which a broad‐range magnetic spectrograph can be operated as such or in connection with a magnetic quadrupole lens to form a high‐intensity spectrometer. A solid angle of approximately 10−2steradian can be attained with this spectrometer without use of very large magnet gaps.
ISSN:0034-6748
DOI:10.1063/1.1716028
出版商:AIP
年代:1958
数据来源: AIP
|
16. |
Phase Shift Method of Carrier Lifetime Measurements in Semiconductors |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 889-891
E. Harnik,
A. Many,
N. B. Grover,
Preview
|
PDF (242KB)
|
|
摘要:
A direct reading instrument for lifetime measurements in semiconductors is described. It is based on the phase shift that exists between a sinusoidal modulation of carrier injection and the corresponding modulation of specimen conductance. Carrier injection is effected optically, a Kerr cell being used to modulate the intensity of the injecting light. The phase shift is determined by means of a compensatingRCcircuit which allows a direct reading of lifetime. The actual measurement is reduced to the setting of a variable resistor in such a way that an ellipse observed on the screen of a CRO degenerates into a straight line. The performance of the instrument is discussed for the case of a thin, rectangular filament illuminated on one of its large faces either homogeneously or in a narrow band.
ISSN:0034-6748
DOI:10.1063/1.1716029
出版商:AIP
年代:1958
数据来源: AIP
|
17. |
Symmetrical Raster Generator for Detonation Velocity Measurement in Explosives |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 892-893
Paul A. Kendall,
Adolph B. Amster,
Preview
|
PDF (144KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1716030
出版商:AIP
年代:1958
数据来源: AIP
|
18. |
Precision Liquid Nitrogen Trap Level Controller |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 893-895
George F. Wells,
Preview
|
|
ISSN:0034-6748
DOI:10.1063/1.1716032
出版商:AIP
年代:1958
数据来源: AIP
|
19. |
Positive‐Feed Fluid Pump with Variable Flow Rate |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 895-896
Graeme P. Welch,
Preview
|
PDF (171KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1716033
出版商:AIP
年代:1958
数据来源: AIP
|
20. |
High‐Pressure Gas‐to‐Liquid Transducer |
|
Review of Scientific Instruments,
Volume 29,
Issue 10,
1958,
Page 896-896
Don O. Coffin,
Preview
|
PDF (80KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1716034
出版商:AIP
年代:1958
数据来源: AIP
|