11. |
Servo‐Controlled Measuring Bridge for Semiconductors of High Resistivity |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 763-766
J. H. Fermor,
A. Kjekshus,
Preview
|
PDF (264KB)
|
|
摘要:
A servo‐controlled measuring bridge for resistivity and Hall effect measurements on semiconducting materials with specimen resistances of up to 1013&OHgr; is described.
ISSN:0034-6748
DOI:10.1063/1.1719697
出版商:AIP
年代:1965
数据来源: AIP
|
12. |
Pairs of CdS Crystals with Matched Photoresponses |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 767-767
Donald D. Snyder,
Preview
|
PDF (88KB)
|
|
摘要:
This paper is a report of a study undertaken to ascertain the feasibility of developing identically photoresponsive CdS crystals for x‐ray monitoring applications. Of the crystals studied nearly one half could be matched into pairs with very nearly identical photoresponse to changes in visible and x‐ray (30 kV) irradiation intensity.
ISSN:0034-6748
DOI:10.1063/1.1719698
出版商:AIP
年代:1965
数据来源: AIP
|
13. |
Economical Liquid Helium Cryostat and other Cryogenic Apparatus |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 768-771
J. E. Whitehouse,
T. A. Callcott,
J. A. Naber,
J. S. Raby,
Preview
|
PDF (280KB)
|
|
摘要:
A liquid helium cryostat which is inexpensive and simple to build is described. Its main features originate from the use of spherical metal floats arranged concentrically to form the body of the vessel. The tailpiece used with the cryostat provides for liquid helium to circulate in the sample holder. A mechanical valve allows the flow of liquid to be interrupted so that temperatures above 4.2°K may be maintained. A typical combination of cryostat and tailpiece has a capacity for 2 liters of liquid helium and will store this charge for nearly 4 days.A liquid nitrogen vacuum system cold trap and a liquid helium transfer tube are also described. The former also features the use of metal floats in its construction. The transfer tube has a degree of flexibility and a very small outer diameter.
ISSN:0034-6748
DOI:10.1063/1.1719699
出版商:AIP
年代:1965
数据来源: AIP
|
14. |
Field Modulation Techniques for Resolution Enhancement in ESR Spectroscopy |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 771-774
Sivert H. Glarum,
Preview
|
PDF (284KB)
|
|
摘要:
Methods for reducing linewidths in electron spin resonance spectroscopy by 50–70% using complex magnetic field modulation waveforms are described. Results obtained using a field modulation line sharpener are presented to demonstrate the usefulness of such techniques.
ISSN:0034-6748
DOI:10.1063/1.1719700
出版商:AIP
年代:1965
数据来源: AIP
|
15. |
Stable, Distributed‐Dynode Electron Multiplier |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 775-779
C. A. Spindt,
K. R. Shoulders,
Preview
|
PDF (352KB)
|
|
摘要:
The development of a high gain, stable electron multiplier is described. The configuration investigated consists of two rectangular, continuous dynodes forming a plane‐parallel channel. Details of strip preparation, film deposition, and experimental performance values are discussed.
ISSN:0034-6748
DOI:10.1063/1.1719701
出版商:AIP
年代:1965
数据来源: AIP
|
16. |
New Precision Thermometric Titration Calorimeter |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 779-783
J. J. Christensen,
R. M. Izatt,
L. D. Hansen,
Preview
|
PDF (374KB)
|
|
摘要:
A new solution calorimeter is described which combines the thermometric titration techniques with the precision and accuracy of conventional solution calorimetry. The calorimeter through use of a unique design has a low heat leakage,k= 1.1×10−3min−1, and a short equilibration period, 1–3 sec. Measurements of quantities of heat as small as 4 calories with an accuracy of 0.1% are possible. The heat of ionization of water at zero ionic strength has been determined to be 13.34±0.02 kcal/mole which is in excellent agreement with the value of 13.34±0.01 kcal/mole determined by conventional solution calorimetry. The large amount of information obtained from a single run makes this type of calorimeter a valuable addition to the field of solution calorimetry.
ISSN:0034-6748
DOI:10.1063/1.1719702
出版商:AIP
年代:1965
数据来源: AIP
|
17. |
Calculation of Spectral Distortion due to Pile‐Up Effect |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 784-794
Raymond Gold,
Preview
|
PDF (693KB)
|
|
摘要:
The effect of pile‐up distortion in the pulse height spectrum of a detector has been determined in the form of an integral representation. A number of important special cases, which arise in experimental applications, are treated. The integral representations for these cases have been evaluted in regions of experimental interest. Comparisons are given between the present numerical results and other estimates of pile‐up distortion.
ISSN:0034-6748
DOI:10.1063/1.1719703
出版商:AIP
年代:1965
数据来源: AIP
|
18. |
Frequency Modulation of Large Cavities |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 794-796
K. B. Rajangam,
F. Hai,
K. R. MacKenzie,
Preview
|
PDF (223KB)
|
|
摘要:
A model study is described in which a rotating capacitor is coupled to a large re‐entrant cavity. The size and capacitive loading (∼500 pF) are such as to make modulation by ferrites or broadband amplifiers difficult and expensive. A nominal frequency range of 3 to 1 is achieved with a single‐plate six‐bladed rotor. On a possible fullscale cavity with a range of approximately 9 to 3 Mc, the data are scaled to a voltage of 5 kV peak for rf power requirements of 1 to 4.4 kW.
ISSN:0034-6748
DOI:10.1063/1.1719704
出版商:AIP
年代:1965
数据来源: AIP
|
19. |
Equilibration of the Ice‐Water Temperature Standard |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 797-799
Edmond S. Miksch,
Preview
|
PDF (226KB)
|
|
摘要:
A test has been made of the accuracy with which an ice‐water system establishes the equilibrium temperature. A device consisting of a bulb containing ice and water with provision for volumetric measurement is used as a thermometer. This was placed in the re‐entrant well of a chamber similar to those used to establish the triple point. The temperature established by the well chamber was varied by varying the pressure of the water in it. It was found that when the temperature was made to differ from the equilibrium temperature of the thermometer by as little as 3×10−6°C, growth or melting occurred in the thermometer.
ISSN:0034-6748
DOI:10.1063/1.1719705
出版商:AIP
年代:1965
数据来源: AIP
|
20. |
Precision (0.1°C) Vacuum Cryostat and Furnace for Mo¨ssbauer Experiments |
|
Review of Scientific Instruments,
Volume 36,
Issue 6,
1965,
Page 800-802
F. Van Der Woude,
G. Boom,
Preview
|
PDF (244KB)
|
|
摘要:
The design of a small vacuum cryostat and furnace for a Mo¨ssbauer spectrometer is described. A regulating system for a 0.1°C temperature stability for periods of several days is given.
ISSN:0034-6748
DOI:10.1063/1.1719706
出版商:AIP
年代:1965
数据来源: AIP
|