11. |
Measurement of Electronic Susceptibilities by Means of Nuclear Resonance Absorption |
|
Review of Scientific Instruments,
Volume 26,
Issue 3,
1955,
Page 293-294
G. Feher,
W. D. Knight,
Preview
|
PDF (155KB)
|
|
摘要:
The proton nuclear magnetic resonance is observed in two crossed capillary tubes embedded in a paramagnetic material in a constant external field. The resonance frequencies from the two capillaries depend on the respective demagnetizing factors. For Mn2O3the two resonance lines are separated by 13.0 kc at 22.3 Mc, giving a mass susceptibility of 65×10−6cgs, in agreement with values obtained by other methods. For a magnetic field homogeneity of about one part in 107over the sample, the ultimate sensitivity of the method would be 10−7to 10−8susceptibility unit. Measurements can be made at low temperatures.
ISSN:0034-6748
DOI:10.1063/1.1771280
出版商:AIP
年代:1955
数据来源: AIP
|
12. |
Resolution of Alpha‐Particle Spectra by Ionization Pulse Analysis of Collimated Samples |
|
Review of Scientific Instruments,
Volume 26,
Issue 3,
1955,
Page 295-302
D. W. Engelkemeir,
L. B. Magnusson,
Preview
|
PDF (592KB)
|
|
摘要:
A high‐resolution ion pulse analyzer has been developed for the study of alpha‐decay fine structure. Alpha‐particle spectra are distorted in conventional high geometry measurements by addition of ionization from excited‐state radiations of the daughter atom. Covering the sample foil with electroformed nickel mesh of a few mils thickness proved to be an effective technique for collimating the alpha particles and absorbing coincident excited‐state radiations. The resolution of the instrument was tested with samples of Bi212, Th230, and Pu238. The measured intensities and particle energies are in satisfactory agreement with magnetic deflection data. Alpha peak standard deviations of 12–13 kev were obtained at a detection efficiency of 0.04 count per disintegration. The standard deviation due to amplifier noise alone amounted to 10 kev.
ISSN:0034-6748
DOI:10.1063/1.1771281
出版商:AIP
年代:1955
数据来源: AIP
|
13. |
High‐Vacuum Jet System for Condensation Pumps |
|
Review of Scientific Instruments,
Volume 26,
Issue 3,
1955,
Page 303-304
J. S. George,
Preview
|
|
ISSN:0034-6748
DOI:10.1063/1.1771285
出版商:AIP
年代:1955
数据来源: AIP
|
14. |
X‐Ray Beam Measurement of Distortion in a Magnet Cloud Chamber |
|
Review of Scientific Instruments,
Volume 26,
Issue 3,
1955,
Page 304-305
Robert Mowbray Walker,
Preview
|
PDF (157KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1771286
出版商:AIP
年代:1955
数据来源: AIP
|
15. |
Nickel Diffusion Leak for Hydrogen |
|
Review of Scientific Instruments,
Volume 26,
Issue 3,
1955,
Page 305-306
E. R. Harrison,
L. C. W. Hobbis,
Preview
|
|
ISSN:0034-6748
DOI:10.1063/1.1771288
出版商:AIP
年代:1955
数据来源: AIP
|