11. |
A Method for Measuring Short Period Activities |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 458-461
A. D. Schelberg,
M. B. Sampson,
Allan C. G. Mitchell,
Preview
|
PDF (217KB)
|
|
摘要:
By photographing an oscilloscope it is possible to measure short periods ranging from 0.1 second to 5 seconds. The pulses from a Geiger counter are fed into thexaxis amplifier of an oscilloscope using no sweep. An oscillograph recorder is used to photograph the cathode‐ray tube so that a record of all the pulses from the counter is obtained. The activated target is moved from the bombardment position to the counting position in about 0.2 second by means of a pneumatic tube. Exposure of calcium to a 23‐Mev alpha‐particle beam resulted in an activity with a half‐life of 0.58±0.04 second. This activity may be assigned to Ti43produced by the reaction Ca40(&agr;,n)Ti43.
ISSN:0034-6748
DOI:10.1063/1.1741296
出版商:AIP
年代:1948
数据来源: AIP
|
12. |
The Use of Retarding Potentials with the Mass Spectrometer |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 462-466
R. E. Fox,
J. A. Hipple,
Preview
|
PDF (314KB)
|
|
摘要:
In addition to the use of stopping potentials for the study of metastable ions in a mass spectrometer, there are several other important uses including the study of ions formed with kinetic energy. There are also several interesting phenomena associated with this method which were encountered when this arrangement was first used. A summary of the authors' experiences with this method is given for the benefit of those who might plan to use this arrangement in the future.
ISSN:0034-6748
DOI:10.1063/1.1741297
出版商:AIP
年代:1948
数据来源: AIP
|
13. |
Multiple Geiger Counters for the Observation of Particle Tracks |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 467-470
William H. Chambers,
Preview
|
PDF (256KB)
|
|
摘要:
An array of sixteen, self‐quenching, Geiger counters is described, which employs a matrix of parallel, small diameter wires for electrodes. The gas atmosphere is common to all counters. The array and attendant recording circuit is used to observe the tracks of charged particles. A spurious count, caused by incomplete absorption of the photons by the polyatomic gas, occurs in a counter adjacent to the track for about 1.5 percent of the primary tracks.
ISSN:0034-6748
DOI:10.1063/1.1741298
出版商:AIP
年代:1948
数据来源: AIP
|
14. |
Cathode‐Ray Oscilloscope Camera |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 471-472
D. D. Bare,
Preview
|
PDF (194KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1741299
出版商:AIP
年代:1948
数据来源: AIP
|
15. |
Adjustable Aperture for Electron Microscope, RCA Type EMU |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 472-473
John T. Quynn,
Preview
|
PDF (155KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1741300
出版商:AIP
年代:1948
数据来源: AIP
|
16. |
High Speed Coincidence Circuit Used for Multipliers |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 473-474
E. Baldinger,
P. Huber,
K. P. Meyer,
Preview
|
PDF (144KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1741301
出版商:AIP
年代:1948
数据来源: AIP
|
17. |
Beta‐Ray Spectrometer Magnetic Shielding |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 474-474
David E. Alburger,
Preview
|
PDF (77KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1741302
出版商:AIP
年代:1948
数据来源: AIP
|
18. |
An Improvement of &agr;‐Particle Counters |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 475-476
M. A. Guimara˜es,
P. A. Sampaio,
Preview
|
|
ISSN:0034-6748
DOI:10.1063/1.1741305
出版商:AIP
年代:1948
数据来源: AIP
|
19. |
New Instruments |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 476-483
W. A. Wildhack,
Preview
|
PDF (657KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1741306
出版商:AIP
年代:1948
数据来源: AIP
|
20. |
New Materials |
|
Review of Scientific Instruments,
Volume 19,
Issue 7,
1948,
Page 483-484
Forest K. Harris,
Preview
|
PDF (162KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1741307
出版商:AIP
年代:1948
数据来源: AIP
|