21. |
Argon triple point realization cryostat for platinum resistance long stem thermometers |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1519-1521
J. Ancsin,
J. Phillips,
Preview
|
PDF (164KB)
|
|
摘要:
A high‐precision realization cryostat was developed for long stem type platinum resistance thermometers at the argon triple point. Six liters of argon gas (at room temperature) are sufficient for calibration and if ultrahigh purity grade is used one may expect the results to yield better than ±1 mK accuracy.
ISSN:0034-6748
DOI:10.1063/1.1134567
出版商:AIP
年代:1976
数据来源: AIP
|
22. |
Marginal oscillator optimized for radiofrequency size effect measurements |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1522-1526
P. A. Probst,
B. Collet,
W. M. MacInnes,
Preview
|
PDF (328KB)
|
|
摘要:
A marginal oscillator (1–50 MHz) operating at relatively high, stable oscillation levels, with very low noise, is described. Phase‐sensitive detection of the real and imaginary parts of the surface impedance of metals or the nuclear susceptibility can be carried out from 0.5 Hz as a result of the low 1/fnoise. The noise is dominated by this 1/fnoise below 200 Hz, while at higher frequencies it is white and the oscillator has a noise factor of 1.15 or 0.6 dB.
ISSN:0034-6748
DOI:10.1063/1.1134568
出版商:AIP
年代:1976
数据来源: AIP
|
23. |
Digital detector for monitoring lidar output energy |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1527-1530
J. A. Reagan,
J. D. Spinhirne,
T. V. Bruhns,
R. L. Peck,
Preview
|
PDF (225KB)
|
|
摘要:
A digital detector for monitoring laser output energy that has been used successfully for accurate collection of lidar data is presented. The detector includes both an optical system to sample laser pulses and electronic circuitry to provide a digitized electronic output proportional to the energy in the sampled light pulses. Test results show that the detector system is capable of monitoring lidar relative output energy to within 1%.
ISSN:0034-6748
DOI:10.1063/1.1134569
出版商:AIP
年代:1976
数据来源: AIP
|
24. |
Apparatus for alternating fields microelectrophoresis |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1531-1535
Evelyne Delatour,
Maxime Hanss,
Preview
|
PDF (318KB)
|
|
摘要:
Based on principles which are outlined, an apparatus for alternating fields microelectrophoroesis is described. It uses a laternal orientation cell which is moved vertically at constant speed while a wave burst is applied to the cell. The resulting particles movements are photographed through dark‐field illumination and a microscope. The mobility is deduced from the track amplitudes on the photographs. An easy temperature correction is given. The main advantage of the A. C. microelectroesis method is a higher precision in the determination of the mobility distribution curve.
ISSN:0034-6748
DOI:10.1063/1.1134574
出版商:AIP
年代:1976
数据来源: AIP
|
25. |
Measurement of thermal expansion at high temperatures by laser interferometry of two fibers |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1536-1541
G. W. Hollenberg,
W. N. Sharpe,
Preview
|
PDF (382KB)
|
|
摘要:
Thermal expansion is determined by measuring interferometrically the relative displacement of two fibers attached to specimens. Coherent monochromatic light from a laser incident upon the two adjacent fibers produces a Fraunhofer fringe pattern. Relative displacement of the fibers can then be determined by monitoring the motion of the fringe pattern. The technique was applied to the measurement of thermal expansion of ceramics in air to 1150 °C and of graphites in vacuum to 1900 °C.
ISSN:0034-6748
DOI:10.1063/1.1134575
出版商:AIP
年代:1976
数据来源: AIP
|
26. |
Versatile x‐ray spectrometer in the range 5–200 keV |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1542-1546
J. D. Strachan,
Preview
|
PDF (347KB)
|
|
摘要:
A spectrometer is described which provides time resolution down to a few nanoseconds and broad‐band energy resolution in the range 5–200 keV along a single line of sight. The spectrometer consists of five channels arranged so that the x rays which are not absorbed in one plastic scintillator pass on to the next channel, but the scintillator emission is deflected onto a photomultiplier.
ISSN:0034-6748
DOI:10.1063/1.1134576
出版商:AIP
年代:1976
数据来源: AIP
|
27. |
Effect of scattered light on temperature measurement by optical pyrometry |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1547-1550
R. E. Einziger,
J. N. Mundy,
Preview
|
PDF (293KB)
|
|
摘要:
The difficulties associated with the use of optical pyrometry for temperature measurement in an electron‐beam furnace are discussed. Light from the filaments producing the electron beam may be scattered into the optical pyrometer. A procedure has been developed that allows a determination of the required correction to the optical pyrometer reading which will take into account the scattered‐light effect and also the error introduced by the correction. The problems associated with the use of thermocouples at high voltage in an electron‐beam furnace are also evaluated.
ISSN:0034-6748
DOI:10.1063/1.1134577
出版商:AIP
年代:1976
数据来源: AIP
|
28. |
On the sample holders for the superconducting magnetometer |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1551-1552
M. Cerdonio,
C. Messana,
C. Gramaccioni,
Preview
|
PDF (118KB)
|
|
摘要:
A simple modification of the sample holders for our superconducting magnetometer is described. It eliminates the holder contribution from the total signal.
ISSN:0034-6748
DOI:10.1063/1.1134546
出版商:AIP
年代:1976
数据来源: AIP
|
29. |
Novel short recovery time high‐voltage switch |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1552-1553
M. Dufour,
H. Egger,
W. Seelig,
Preview
|
PDF (168KB)
|
|
摘要:
A novel sealed‐off low‐pressure quenching discharge gap capable of switching voltages up to 25 kV has been built. A recovery time of a few microseconds was measured, allowing switching rates in the 100 kHz range.
ISSN:0034-6748
DOI:10.1063/1.1134547
出版商:AIP
年代:1976
数据来源: AIP
|
30. |
Blanking resistive heating circuit for Auger electron spectroscopy experiments |
|
Review of Scientific Instruments,
Volume 47,
Issue 12,
1976,
Page 1554-1555
Yung‐Yi Tu,
J. M. Blakely,
Preview
|
PDF (111KB)
|
|
摘要:
A blanking circuit is described that is suitable for resistively heated samples. The Auger spectrum is blanked synchronously with the pulsed heating current. This arrangement allows the detection of undistorted Auger spectra from a fixed point on the specimen surface.
ISSN:0034-6748
DOI:10.1063/1.1134548
出版商:AIP
年代:1976
数据来源: AIP
|