21. |
Logarithmic Readout Attachment for Double‐Beam Spectrophotometers |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 338-339
J. R. Shepherd,
H. R. Hedgpeth,
Preview
|
|
摘要:
The described attachment will process the output from a manual readout spectrophotometer, take the log10of reference minus the log of the signal (log10Io/I), and feed that to a recorder.
ISSN:0034-6748
DOI:10.1063/1.1686126
出版商:AIP
年代:1973
数据来源: AIP
|
22. |
Differences Between ac and dc Determinations of Germanium Thermometer Resistances |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 339-341
C. A. Swenson,
P. C. F. Wolfendale,
Preview
|
PDF (224KB)
|
|
摘要:
The resistances of several germanium thermometers are found to differ for ac and dc measurements. At 300 K, these differences are frequency independent from roughly 5 to 103Hz. The ac resistances always are smaller, and the approximate temperature differences (Tdc−Tac) vary from 100 mk at 77 K to 0.2 mK below 17 K.
ISSN:0034-6748
DOI:10.1063/1.1686127
出版商:AIP
年代:1973
数据来源: AIP
|
23. |
Inexpensive High Vacuum Feedthroughs |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 341-342
S. Gerber,
D. Post,
Preview
|
PDF (146KB)
|
|
摘要:
Rigid coaxial cable has been used to construct simple, inexpensive high vacuum coaxial and coaxial push pull rotary motion feedthroughs.
ISSN:0034-6748
DOI:10.1063/1.1686128
出版商:AIP
年代:1973
数据来源: AIP
|
24. |
Magnetic and Electrostatic Deflectors for Charged‐Particle Beams |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 342-343
W. Haeberli,
Preview
|
PDF (133KB)
|
|
摘要:
It is often assumed that uniform electrostatic or magnetic fields are required if all particles in a parallel beam of ions of finite diameter are to be deflected through the same angle. It is shown that the nonuniform field caused even by very short electrodes or pole pieces produces uniform deflection under certain conditions.
ISSN:0034-6748
DOI:10.1063/1.1686129
出版商:AIP
年代:1973
数据来源: AIP
|
25. |
A Digital Electrode Controller for the Spark Source Mass Spectrometer |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 343-345
Lewis A. Fergason,
John D. Dowdy,
Preview
|
PDF (276KB)
|
|
摘要:
An automatic electrode controller is described for an r.f. spark source mass spectrometer. It maintains the spacing between the electrodes to provide constant breakdown voltage.
ISSN:0034-6748
DOI:10.1063/1.1686130
出版商:AIP
年代:1973
数据来源: AIP
|
26. |
A Pulse Amplitude to dc Voltage Converter |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 345-346
Mikio Yamashita,
Preview
|
PDF (126KB)
|
|
摘要:
A simple instrument is described which provides a dc voltage corresponding to the amplitude of a pulse train. The instrument permits measurements of input pulse amplitudes with an accuracy of [inverted lazy s] 0.1%.
ISSN:0034-6748
DOI:10.1063/1.1686131
出版商:AIP
年代:1973
数据来源: AIP
|
27. |
A Compact Demountable Superleak ‐ Tight Seal for Low Temperature Experiments |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 346-347
Roger E. Little,
Yu Liu,
Preview
|
PDF (121KB)
|
|
摘要:
A technique for applying and removing a superleak ‐ tight epoxy seal is described. The advantages of the seal are that no heat or pressure is required to make the seal.
ISSN:0034-6748
DOI:10.1063/1.1686132
出版商:AIP
年代:1973
数据来源: AIP
|
28. |
An Optical Absorption Cell with Vapor Cross Flow |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 347-348
P. E. Hendrickson,
W. L. Walls,
S. Broersma,
Preview
|
PDF (130KB)
|
|
摘要:
In order to avoid wall contamination, and to simulate an open air system, a water vapor cross flow instrument has been designed. Vapor equilibrium is established within 30 min. A 6.3 &mgr; infrared beam traverses the pressure, temperature, and humidity controlled vapor column. The effect of these thermodynamic parameters can be examined.
ISSN:0034-6748
DOI:10.1063/1.1686133
出版商:AIP
年代:1973
数据来源: AIP
|
29. |
Measurement of Contrast Changes in Scanning Electron Microscopy |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 348-349
E. M. Schulson,
Preview
|
PDF (139KB)
|
|
摘要:
A direct and rapid method is described for measuring changes in contrast on SEM images. The method is based on the fact that a given level of contrast can be detected only if the beam current at the specimen exceeds a critical value.
ISSN:0034-6748
DOI:10.1063/1.1686134
出版商:AIP
年代:1973
数据来源: AIP
|
30. |
A Function Generator for Dynamic Control of a Plasma |
|
Review of Scientific Instruments,
Volume 44,
Issue 3,
1973,
Page 349-350
Atsushi Ogata,
Tetsuo Watari,
Preview
|
PDF (142KB)
|
|
摘要:
A function generator is constructed to generate voltage as any given function of input voltage. The generator approximates any function including a nonmonotonic one by quantizing it into 11 steps. It has fast response (less than 100 nsec), good frequency characteristic (up to 10 MHz), and is easy to construct. It is to be used with aV‐to‐fconverter in a feedback loop of rf confinement of a plasma, where the most favorable frequency is given as a nonlinear function of plasma density.
ISSN:0034-6748
DOI:10.1063/1.1686135
出版商:AIP
年代:1973
数据来源: AIP
|