31. |
Movable and Fixed Modular Vacuum Devices with Confined Fluorocarbon Plastic Seals |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1076-1082
R. L. Anderson,
L. A. Guildner,
R. E. Edsinger,
Preview
|
PDF (561KB)
|
|
摘要:
Sealing techniques have been perfected which utilize the properties of fluorocarbon plastics to make high vacuum seals. Several designs are described in which confined gaskets are used instead of O‐rings, with consequent reduction of contamination from outgassing and permeation. These sealing techniques have been incorporated into a series of modular components which may be used for assembly of high vacuum systems. Some of these components are movable joints which allow leak‐free motion between parts of a system. While not suited for high temperature bakeout, systems constructed from these modular components are capable of being pumped below 10−7Torr. Dependable systems can easily be assembled or modified using these components, with no detectable helium leaks at a level of 2×10−10std cm3/sec.
ISSN:0034-6748
DOI:10.1063/1.1684697
出版商:AIP
年代:1970
数据来源: AIP
|
32. |
A New Instrument for the Measurement of Liquid Level |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1083-1087
K. Lindstro¨m,
H. Kjellander,
C. Jonsson,
Preview
|
PDF (375KB)
|
|
摘要:
A new instrument for the measurement of liquid level has been developed, which makes use of the fact that an electric pulse advancing on a transmission line is reflected from any point on the line where the line impedance changes abruptly. Such a change of impedance is obtained at a sudden change of the dielectric constant in the transmission line, i.e., if a fluid is partially introduced in the line. The instrument is further based on the sing‐around principle, which gives directly a digital output signal of high accuracy and linearity, in the order of ±0.02%. The instrument can be used for all liquids having a dielectric constant greater than 1.1 or sufficient electrical conductivity.
ISSN:0034-6748
DOI:10.1063/1.1684698
出版商:AIP
年代:1970
数据来源: AIP
|
33. |
A Capacitor for Accurate Wide Range Dielectric Constant Measurements on Compressed Fluids |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1087-1089
B. A. Younglove,
G. C. Straty,
Preview
|
PDF (234KB)
|
|
摘要:
A capacitor is described which has been used to make accurate measurements of the dielectric constant of liquid and gaseous oxygen over a wide temperature (55–300 K) and pressure (0.2–34 MN/m2) range. The capacitor is simple to construct and its stability is unaffected by large hydrostatic pressure variations. The temperature variation of the vacuum capacitance is small and remains reproducible even after repeated temperature and pressure cycling.
ISSN:0034-6748
DOI:10.1063/1.1684699
出版商:AIP
年代:1970
数据来源: AIP
|
34. |
A3He Cryostat for Dynamic Proton Polarization |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1090-1091
A. Masaike,
M. Eisenkremer,
H. Gla¨ttli,
Preview
|
PDF (157KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1684700
出版商:AIP
年代:1970
数据来源: AIP
|
35. |
Flash Burst Operation of an Electronic Stroboscope |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1091-1092
Allen D. Wood,
Preview
|
PDF (179KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1684701
出版商:AIP
年代:1970
数据来源: AIP
|
36. |
Temperature Control Circuit for Simultaneous Evaporation from Two Sources |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1092-1094
E. J. White,
J. R. Clarke,
Preview
|
|
ISSN:0034-6748
DOI:10.1063/1.1684703
出版商:AIP
年代:1970
数据来源: AIP
|
37. |
Time Lag Calibration of Insulated Pressure Probes |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1094-1095
R. M. Schmidt,
A. P. Waggoner,
M. F. Weisbach,
Preview
|
|
ISSN:0034-6748
DOI:10.1063/1.1684705
出版商:AIP
年代:1970
数据来源: AIP
|
38. |
Miniature Field Emission X‐Ray Tube |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1095-1096
J. H. McCrary,
L. D. Looney,
Preview
|
PDF (166KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1684706
出版商:AIP
年代:1970
数据来源: AIP
|
39. |
A MOSFET Gate with 100 dB Carrier Suppression |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1096-1097
B. Michael Moores,
Ron H. Munnings,
Robin L. Armstrong,
Preview
|
PDF (166KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1684707
出版商:AIP
年代:1970
数据来源: AIP
|
40. |
A Simple Technique for Single Shot, Microwave Spectrum Analysis |
|
Review of Scientific Instruments,
Volume 41,
Issue 7,
1970,
Page 1097-1098
John A. Nation,
Preview
|
PDF (189KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1684708
出版商:AIP
年代:1970
数据来源: AIP
|