31. |
Method for the preparation of dielectric films by activated reactive evaporation using resistively heated sources |
|
Review of Scientific Instruments,
Volume 57,
Issue 9,
1986,
Page 2355-2356
Joy George,
B. Pradeep,
K. S. Joseph,
Preview
|
PDF (156KB)
|
|
摘要:
A simple method is reported for the deposition of dielectric films using activated reactive evaporation (ARE). This method uses heated tungsten wire as an electron emitter and does not require a magnetic field for stabilizing the plasma, as required in an earlier reported method. The reactive gas pressure during coating is 5×10−4Torr. An x‐ray diffractogram and optical transmission spectra of Bi2O3films deposited at a rate ≊50 A˚/s using this apparatus are also presented.
ISSN:0034-6748
DOI:10.1063/1.1138676
出版商:AIP
年代:1986
数据来源: AIP
|
32. |
Fast‐opening magnetic valve for high‐pressure gas injection and applications to hydrogen pellet fueling systems |
|
Review of Scientific Instruments,
Volume 57,
Issue 9,
1986,
Page 2356-2358
S. L. Milora,
S. K. Combs,
C. R. Foust,
Preview
|
PDF (227KB)
|
|
摘要:
A fast, magnetically driven gas valve and its application to pneumatic‐based solid hydrogen pellet injectors are described. The valve, which is equipped with a polyimide stem tip (hard seal) and a 5‐mm‐diam orifice, can open against working pressures up to 140 bar (2000 psi). Other unique features of this design include temperature‐ and radiation‐resistant seals, a programmable output pressure pulse, and repetitive operation in excess of 20 Hz. A prototype valve has been used to propel frozen hydrogen isotope pellets to speeds of up to 1900 m/s.
ISSN:0034-6748
DOI:10.1063/1.1138677
出版商:AIP
年代:1986
数据来源: AIP
|
33. |
Rectangular waveguide calorimeter for single intense microwave pulses |
|
Review of Scientific Instruments,
Volume 57,
Issue 9,
1986,
Page 2359-2361
L. M. Earley,
W. P. Ballard,
L. D. Roose,
Preview
|
PDF (228KB)
|
|
摘要:
A new calorimeter for single intense microwave pulses has been designed and tested. The device was constructed in WR284 rectangular waveguide and was operated at frequencies from 2.5 to 4.3 GHz with a tunable instantaneous bandwidth of approximately 500 MHz. The calorimeter used a single thermistor to measure the energy deposited on a carbon absorber having a microwave power absorbance of 90%. The calorimeter was tested at power levels from 100 to 1000 MW for pulse lengths of 12–6 ns, respectively. The sensitivity of the device was 200–300 mV/J.
ISSN:0034-6748
DOI:10.1063/1.1138678
出版商:AIP
年代:1986
数据来源: AIP
|
34. |
New high‐precision bridge for low‐resistance thermometry |
|
Review of Scientific Instruments,
Volume 57,
Issue 9,
1986,
Page 2361-2362
L. Bruschi,
R. Storti,
G. Torzo,
Preview
|
PDF (137KB)
|
|
摘要:
We describe a simple four‐terminal ac bridge designed to be used with sensors of low resistance, such as platinum thermometer at low temperature.
ISSN:0034-6748
DOI:10.1063/1.1138679
出版商:AIP
年代:1986
数据来源: AIP
|
35. |
Small permanent magnet for fields up to 2.6 T |
|
Review of Scientific Instruments,
Volume 57,
Issue 9,
1986,
Page 2362-2365
R. Oldenbourg,
W. C. Phillips,
Preview
|
PDF (287KB)
|
|
摘要:
We describe a small permanent magnet (no dimension exceeds 8 cm) which produces a uniform magnetic field of 2 T in a volume of about 14 mm3. This magnet has been used to orient macromolecular assemblies for light microscopy, x‐ray, and light‐scattering studies.
ISSN:0034-6748
DOI:10.1063/1.1138680
出版商:AIP
年代:1986
数据来源: AIP
|
36. |
Inexpensive and high‐precision digital power supply and counting interface for UPS, XPS, and Auger spectrometers |
|
Review of Scientific Instruments,
Volume 57,
Issue 9,
1986,
Page 2366-2366
Dennis L. Lichtenberger,
Glen Eugene Kellogg,
John G. Kristofzski,
Dennis Page,
Steve Turner,
Gerry Klinger,
Jim Lorenzen,
Preview
|
PDF (82KB)
|
|
摘要:
A digital data‐acquisition system has been built to interface two photoelectron spectrometers to a DEC LSI‐11/23 processor.
ISSN:0034-6748
DOI:10.1063/1.1139199
出版商:AIP
年代:1986
数据来源: AIP
|
|