31. |
Combined mu‐metal and niobium superconductor shielding for dc SQUID operation |
|
Review of Scientific Instruments,
Volume 58,
Issue 2,
1987,
Page 311-312
Bu‐xin Xu,
W. O. Hamilton,
Preview
|
PDF (226KB)
|
|
摘要:
In this note, we report the use of a combined mu‐metal and niobium superconductor shielding which results in much improved dc SQUID operation. The configuration is suitable for large experiments and is much cheaper than the mu‐metal shielding conventionally used.
ISSN:0034-6748
DOI:10.1063/1.1139278
出版商:AIP
年代:1987
数据来源: AIP
|
32. |
Quadruple thickness monitor with double backup |
|
Review of Scientific Instruments,
Volume 58,
Issue 2,
1987,
Page 313-314
H. Strauven,
E. De Wijngaerdt,
J. Spinnewijn,
O. B. Verbeke,
Preview
|
PDF (234KB)
|
|
摘要:
A quadruple thickness monitor, based on quartz oscillators, in order to control the co‐evaporation of quaternary alloys, is described in detail. Saturated crystals can be changed without interrupting the vacuum. The system is satisfactory in very high vacuum (no degassing at 10−8Torr) and can be adapted to ultrahigh vacuum.
ISSN:0034-6748
DOI:10.1063/1.1139279
出版商:AIP
年代:1987
数据来源: AIP
|
33. |
Use of ‘‘Five‐Minute Epoxy’’ as a cryogenic leak sealant |
|
Review of Scientific Instruments,
Volume 58,
Issue 2,
1987,
Page 314-315
Douglas L. Martin,
Preview
|
PDF (234KB)
|
|
摘要:
‘‘Five‐Minute Epoxy’’ has been used successfully to mend small leaks in a liquid‐helium cryostat; it is an alternative to more specialized epoxies for this purpose.
ISSN:0034-6748
DOI:10.1063/1.1139280
出版商:AIP
年代:1987
数据来源: AIP
|
34. |
Use of a light emitting diode as a current sensor for electrostatic double probes |
|
Review of Scientific Instruments,
Volume 58,
Issue 2,
1987,
Page 315-317
J. Tendys,
Preview
|
PDF (273KB)
|
|
摘要:
A light emitting diode has been used as a convenient current sensor for electrostatic double probes under conditions of very high common mode voltages at frequencies around 1 MHz. A simple probe circuit permitted the signal to be transmitted optically to a remote conditioning and detection circuit. A calibration curve was used to correct the nonlinearities in the system.
ISSN:0034-6748
DOI:10.1063/1.1139281
出版商:AIP
年代:1987
数据来源: AIP
|
35. |
Sample transfer system for surface studies in wide pressure range (10−7–106Pa) |
|
Review of Scientific Instruments,
Volume 58,
Issue 2,
1987,
Page 317-319
Shinichi Ichikawa,
Mahlon S. Wilson,
Preview
|
PDF (240KB)
|
|
摘要:
An inexpensive sample transfer system suitable for surface studies withinsituprepared model catalysts is described. Experiments from ultrahigh vacuum to 10 atm and 50‐cm travel with negligible pressure spikes were made possible by the use of double‐seal glands with spring‐loaded Teflon O‐rings and a guided rotational transport rod.
ISSN:0034-6748
DOI:10.1063/1.1139282
出版商:AIP
年代:1987
数据来源: AIP
|
36. |
Comment on ‘‘Low‐pass filters for signal averaging’’ [Rev. Sci. Instrum.57, 957 (1986)] |
|
Review of Scientific Instruments,
Volume 58,
Issue 2,
1987,
Page 320-320
Daniel H. Sheingold,
Preview
|
PDF (56KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1139283
出版商:AIP
年代:1987
数据来源: AIP
|
37. |
Erratum: New apparatus to perform fast determinations of mixture vapor–liquid equilibria up to 10 MPa and 423 K [Rev. Sci. Instrum.57, 469 (1986)] |
|
Review of Scientific Instruments,
Volume 58,
Issue 2,
1987,
Page 321-321
S. Laugier,
D. Richon,
Preview
|
PDF (61KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1139670
出版商:AIP
年代:1987