31. |
Excess noise of the R 928 photomultiplier |
|
Review of Scientific Instruments,
Volume 58,
Issue 1,
1987,
Page 136-138
M. Ko¨chel,
K. Hirsch,
H. Salzmann,
Preview
|
PDF (344KB)
|
|
摘要:
The noise factor of the HAMAMATSU R 928 circular cage photomultiplier has been measured. It is demonstrated that the optimum mode of operation with respect to the noise is the one with constant interstage voltage distribution. Different effects contributing to the overall noise factor have been identified.
ISSN:0034-6748
DOI:10.1063/1.1139543
出版商:AIP
年代:1987
数据来源: AIP
|
32. |
Emission characteristics of zeolite A ion source |
|
Review of Scientific Instruments,
Volume 58,
Issue 1,
1987,
Page 138-140
Y. Satoh,
M. Takebe,
K. Iinuma,
Preview
|
PDF (348KB)
|
|
摘要:
An easy method to prepare alkali ion emitters has been realized by using the ion‐exchange technique. The thermionic emission characteristics of zeolite A alkali ion sources have been studied. Experimental results indicate that ion transport process within zeolite plays an important role in the emission mechanism.
ISSN:0034-6748
DOI:10.1063/1.1139544
出版商:AIP
年代:1987
数据来源: AIP
|
33. |
Compact, movable Faraday cup for intense electron beam pulses |
|
Review of Scientific Instruments,
Volume 58,
Issue 1,
1987,
Page 140-142
Hidenori Matsuzawa,
Tetsuya Akitsu,
Preview
|
PDF (348KB)
|
|
摘要:
A compact, axially movable Faraday cup of low noise level was devised for measuring an intense electron beam of a duration time of 10 ns or less, with a replaceable aperture to limit incident electron beams in diameter.
ISSN:0034-6748
DOI:10.1063/1.1139545
出版商:AIP
年代:1987
数据来源: AIP
|
34. |
Circuit for extension of an interrupt input of a personal computer PC8001mkII |
|
Review of Scientific Instruments,
Volume 58,
Issue 1,
1987,
Page 142-143
Koichi Matsuura,
Tatsuo Yamasaki,
Satoru Kishida,
Hiroyuki Taki,
Ichiro Tsurumi,
Preview
|
PDF (199KB)
|
|
摘要:
A circuit is described which extends an interrupt input of a personal computer PC8001mkII to multiple interrupt inputs using a daisy‐chain approach, where prioritized interrupts up to 128 levels may be available by providing additional wait states and an interrupt look‐ahead circuit. The circuit presented in this note may be applied to other computers with some slight modifications.
ISSN:0034-6748
DOI:10.1063/1.1139546
出版商:AIP
年代:1987
数据来源: AIP
|
35. |
Removal of phototubes from Pb–glass detectors |
|
Review of Scientific Instruments,
Volume 58,
Issue 1,
1987,
Page 143-144
D. E. Alburger,
Preview
|
PDF (194KB)
|
|
摘要:
A simple procedure is described for removing faulty photomultiplier tubes from Pb–glass detectors by means of heated chloroform.
ISSN:0034-6748
DOI:10.1063/1.1139547
出版商:AIP
年代:1987
数据来源: AIP
|
36. |
Interface for data exchange between a parallel and the IEEE‐488 bus |
|
Review of Scientific Instruments,
Volume 58,
Issue 1,
1987,
Page 144-146
M. Grubic,
Preview
|
PDF (321KB)
|
|
摘要:
Low‐cost talker and listener interfaces between the IEEE‐488 bus and a BCD instrument parallel data bus are described. The circuits do not employ any microprocessor at all. Their versatile handshake lines enable simple connection to numerous devices.
ISSN:0034-6748
DOI:10.1063/1.1139548
出版商:AIP
年代:1987
数据来源: AIP
|
37. |
Timed source of slow protons |
|
Review of Scientific Instruments,
Volume 58,
Issue 1,
1987,
Page 146-147
A. P. Mills,
Preview
|
PDF (175KB)
|
|
摘要:
Alpha particle bombardment of a Si surface‐barrier detector in vacuum causes the release of several species of ions from the contaminant layer on the detector surface. The mass‐to‐charge ratios of the ions are determined by time‐of‐flight spectroscopy. A significant fraction of the ions are H+with a yield of 4×10−5H+per alpha particle and an emission energy of less than 70 eV. This ion source could be useful for testing slow &mgr;+collection optics and possibly for studying the diffusion of H atoms in liquid He.
ISSN:0034-6748
DOI:10.1063/1.1139549
出版商:AIP
年代:1987
数据来源: AIP
|
38. |
Simple system for mapping magnetic field errors in tori |
|
Review of Scientific Instruments,
Volume 58,
Issue 1,
1987,
Page 148-149
P. M. Bellan,
Preview
|
PDF (165KB)
|
|
摘要:
A simple inexpensive electron beam/detector system is described. This system is capable of making vector maps of magnetic field errors over the minor cross section of toroidal plasma devices.
ISSN:0034-6748
DOI:10.1063/1.1139664
出版商:AIP
年代:1987
数据来源: AIP
|