41. |
A piston‐actuated shock‐tube, with laser–Schlieren diagnostics |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1342-1346
S. M. Hurst,
S. H. Bauer,
Preview
|
PDF (502KB)
|
|
摘要:
The essential construction features of a piston actuated shock tube are described, and its advantages relative to the conventional use of diaphragm ruptures for shock initiation are listed. Typical operational parameters are presented to illustrate the levels of reproducibility achieved. Tests with He and N2drivers into ∼99% Ar (1.0%–0.1% reagent) covered shock speeds from 1.539±0.002–0.8143±0.002 mm/&mgr;s, corresponding to 2390–847K incident shock temperatures. Application of this tube for recording postshock front density gradients of the endoergic dissociation of ethane and the exoergic condensation of iron atoms via the laser–Schlieren technique is described.
ISSN:0034-6748
DOI:10.1063/1.1144090
出版商:AIP
年代:1993
数据来源: AIP
|
42. |
Bimorph stepping motor for point‐contact experiments |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1347-1350
J. Heil,
Y. De Wilde,
A. G. M. Jansen,
P. Wyder,
W. Grill,
Preview
|
PDF (489KB)
|
|
摘要:
A rotating piezoelectric device, which uses the so‐called slip‐stick mechanism for micropositioning is presented. The device is especially designed for use in point‐contact experiments at very low temperatures in high magnetic fields. Two typical applications are presented.
ISSN:0034-6748
DOI:10.1063/1.1144091
出版商:AIP
年代:1993
数据来源: AIP
|
43. |
Accurate, inexpensive, thermal expansion microtranslator |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1351-1354
James J. Snyder,
Preview
|
PDF (411KB)
|
|
摘要:
We have developed an accurate, inexpensive translator utilizing the thermal expansion of an electrically heated wire. The resistance of the wire, measured in a Wheatstone bridge, provides a readout of the length of the wire based on its temperature coefficient of resistance.
ISSN:0034-6748
DOI:10.1063/1.1144092
出版商:AIP
年代:1993
数据来源: AIP
|
44. |
Spectrophotometric stopped‐flow apparatus suitable for high‐pressure experiments to 200 MPa |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1355-1357
R. van Eldik,
W. Gaede,
S. Wieland,
J. Kraft,
M. Spitzer,
D. A. Palmer,
Preview
|
PDF (313KB)
|
|
摘要:
A modified high‐pressure, stopped‐flow apparatus has been developed to enable kinetic experiments to be monitored spectrophotometrically to 200 MPa, with efficient mixing of the reactant solutions. This apparatus is compact, relatively inexpensive to construct, and the solutions are only exposed to inert materials, such as Kel‐F, Teflon, quartz (low‐pressure windows), and glass or Viton. The drive‐syringe pistons are propelled by a step motor housed on top of the stopped‐flow unit inside the pressure vessel, resulting in a dead time for the system of ∼10 ms at 25 °C.
ISSN:0034-6748
DOI:10.1063/1.1144466
出版商:AIP
年代:1993
数据来源: AIP
|
45. |
Design of a constant tension thermocouple rake suitable for flame studies |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1358-1359
Sandeep Ahuja,
David L. Miller,
Preview
|
PDF (204KB)
|
|
摘要:
An improved, spring‐loaded thermocouple rake, suitable for studying flame structure, has been designed. This design keeps the thermocouple under tension thereby ensuring that the thermocouple does not droop due to the thermal expansion of the sensing wire when inserted in the flame. The present design allows the usage of thermocouple wire as small as 0.0508 mm and relative ease in changing thermocouple wire.
ISSN:0034-6748
DOI:10.1063/1.1144093
出版商:AIP
年代:1993
数据来源: AIP
|
46. |
A simple self‐propelled two‐dimensional micropositioner |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1360-1361
B. L. Blackford,
Preview
|
PDF (157KB)
|
|
摘要:
A quartz tube is propelled horizontally along a quartz track by the stick‐slip inertial slider method, activated by the longitudinal mode of a piezoelectric tube mounted inside the quartz tube. Two‐dimensional motion is achieved by rotation of the quartz tube, activated by the bending mode of the piezo. With a sample attached to the quartz tube, the device is an excellent replacement for the electrostatic‐clamp type of walker used as the coarse approach mechanism in scanning probe microscopes (SPMs). Alternatively, by attaching the tip (or sample) to the piezo tube, the device can function as a very simple SPM in which the same piezo tube is used for coarse approach and for scanning. The device performs reliably in air and high vacuum, and is ultrahigh vacuum compatible. Step sizes from 10 to 1000 nm, and speeds up to 0.2 mm/s are possible.
ISSN:0034-6748
DOI:10.1063/1.1144094
出版商:AIP
年代:1993
数据来源: AIP
|
47. |
Vessels for preparing and delivering gaseous solutions |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1362-1363
Dean F. Keeley,
William K. Koon,
Preview
|
PDF (237KB)
|
|
摘要:
Two, inexpensive, easily constructed vessels are described which can be used to prepare and deliver measured volumes of parts per million concentrations of gaseous mixtures.
ISSN:0034-6748
DOI:10.1063/1.1144095
出版商:AIP
年代:1993
数据来源: AIP
|
48. |
Magnetic susceptibility of polychlorotrifluoroethylene (PCTFE) |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1364-1364
A. Mari,
L. Brossard,
Preview
|
PDF (113KB)
|
|
摘要:
The magnetic susceptibility of polychlorotrifluoroethylene, commonly named as Kel’f, has been measured in a magnetic field of 2 T from 2 to 300 K. The susceptibility is diamagnetic above 3 K with a small Curie contribution at low temperature.
ISSN:0034-6748
DOI:10.1063/1.1144096
出版商:AIP
年代:1993
数据来源: AIP
|
49. |
Improved furnace temperature control for the PARC vibrating sample magnetometer |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1365-1366
C. H. Sellers,
J. E. Lee,
T. A. Hyde,
Preview
|
PDF (180KB)
|
|
摘要:
Temperature control of furnaces to be used with the PARC vibrating sample magnetometer can be greatly improved if a separate temperature controller is utilized. A control circuit that allows easy temperature programming and ramping is described, as well as sample holder modifications which permit accurate measurement of the sample temperature.
ISSN:0034-6748
DOI:10.1063/1.1144097
出版商:AIP
年代:1993
数据来源: AIP
|
50. |
Simple determination of the frequency response of piezoelectric tubes |
|
Review of Scientific Instruments,
Volume 64,
Issue 5,
1993,
Page 1367-1368
L. Tao,
J. Maps,
Preview
|
PDF (258KB)
|
|
摘要:
A simple technique for measuring the relative extension or response of a piezoelectric tube as a function of frequency is presented. The method clearly identifies resonant modes of the system. This information is useful in tuning feedback control systems in scanned probe microscopes.
ISSN:0034-6748
DOI:10.1063/1.1144098
出版商:AIP
年代:1993
数据来源: AIP
|
|