41. |
A differential transformer as a position detector in a magnetic densimeter |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1462-1463
Sandra C. Greer,
M. R. Moldover,
R. Hocken,
Preview
|
PDF (166KB)
|
|
摘要:
We describe the use of a differential transformer to detect the position of the buoy in a magnetic densimeter, an instrument for precise measurement of fluid densities. This detector can be used in cases where the buoy is not visible and it can be assembled from commercial electronic components.
ISSN:0034-6748
DOI:10.1063/1.1686531
出版商:AIP
年代:1974
数据来源: AIP
|
42. |
A differential ellipsometer |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1464-1465
Jesse I. Treu,
Preview
|
PDF (140KB)
|
|
摘要:
A system is described which provides for direct measurement of the difference between linear dichroism, circular dichroism, or phase shifts (in transmission or reflection) of two adjacent samples. A uniaxial crystal is used to produce two incident light beams of mutually orthogonal polarization. The total intensity is analyzed by a single detector to give the differential quantities.
ISSN:0034-6748
DOI:10.1063/1.1686532
出版商:AIP
年代:1974
数据来源: AIP
|
43. |
Trigger circuits for use in flash photolytic experiments |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1465-1467
J. R. Wiesenfeld,
Preview
|
PDF (172KB)
|
|
摘要:
Two trigger modules suitable for use in flash photolytic apparatus are described. One generates a 30 kV pulse for overvoltage triggering of flash lamps or control of spark gaps. The other produces high voltage, high current pulses for initiating conduction in mercury ignitrons.
ISSN:0034-6748
DOI:10.1063/1.1686533
出版商:AIP
年代:1974
数据来源: AIP
|
44. |
Economical mass spectrometer ion current measurement with a commercial parametric amplifier |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1467-1469
R. D. Russell,
T. K. Ahern,
Preview
|
PDF (261KB)
|
|
摘要:
A Philbrick model 1702 parametric amplifier has been used as an input device for the measurement of mass spectrometer ion currents. The results obtained have been comparable with those obtained by other methods, although the cost is very modest. Combined with an Analogic AN‐2544 ratio meter, it has been used to make an economical ratio recording system for oxygen isotopic analysis.
ISSN:0034-6748
DOI:10.1063/1.1686534
出版商:AIP
年代:1974
数据来源: AIP
|
45. |
A simple and inexpensive fluorescein detector |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1469-1470
Peter E. Engler,
Paul R. Calabrese,
Francis A. Giori,
Preview
|
PDF (181KB)
|
|
摘要:
A simple and inexpensive fluorescein detector is described that is capable of detecting a solution of approximately one part fluorescein to five million parts of water. The device can be constructed in a laboratory or workshop equipped with the minimum tools and instrumentation. As conceived, the device is used as a leak detector and is designed to activate a relay when an aqueous fluorescein solution exceeding a concentration of one part per five million flows through a quartz tube.
ISSN:0034-6748
DOI:10.1063/1.1686535
出版商:AIP
年代:1974
数据来源: AIP
|
46. |
Fast pulsed discharge switching in the 10 kJ range using commercial gaps |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1471-1472
G. Saint‐Hilaire,
J. M. Guay,
K. Dimoff,
Preview
|
PDF (161KB)
|
|
摘要:
A moderately powered, multipurpose, fast pulsed discharge source is described in which standardized components are used to ``parallel switch'' a condenser bank. The system is virtually maintenance free, exhibits an overall jitter of less than 0.2 &mgr;sec in current breakdown and can operate flexibly over a range in storage energy from 0.8 to 8 kJ.
ISSN:0034-6748
DOI:10.1063/1.1686536
出版商:AIP
年代:1974
数据来源: AIP
|
47. |
Instrumental broadening of the parallel plate analyzer |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1472-1474
Grayson H. Rayborn,
Ta‐Lee Hsiao,
Preview
|
PDF (160KB)
|
|
摘要:
Broadening curves for the parallel plate energy analyzer are presented for Gaussian input kinetic energy distributions, for no angular broadening, and for a uniform angular distribution over ±30for an analyzer of nominal resolution of forty. Use of the curves is demonstrated on a measured kinetic energy spectrum of Ar+ions. The broadening curve for two Gaussian functions is given for comparison.
ISSN:0034-6748
DOI:10.1063/1.1686537
出版商:AIP
年代:1974
数据来源: AIP
|
48. |
A rigid microwave access lens into copper‐shielded plasma physics experiments |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1474-1475
C. A. J. Hugenholtz,
Preview
|
PDF (148KB)
|
|
摘要:
In this note, a microwave lens is described giving easy access through the copper shell of the SPICA experiment without disturbing the shielding effect. The lens consists of a number of small holes drilled in a solid plane metal disk. With increasing radius, the holes in the lens become smaller in diameter, so the phase velocity will increase towards the edge which produces a focusing effect for microwaves.
ISSN:0034-6748
DOI:10.1063/1.1686538
出版商:AIP
年代:1974
数据来源: AIP
|
49. |
A multi‐exposure x‐ray powder camera for high pressure work |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1475-1476
Joginder Singh,
Preview
|
PDF (205KB)
|
|
摘要:
A multi‐exposure powder camera for high pressure x‐ray diffraction studies up to 150 kilobars is described.
ISSN:0034-6748
DOI:10.1063/1.1686539
出版商:AIP
年代:1974
数据来源: AIP
|
50. |
A differential pressure sensor for use in high ambient pressures |
|
Review of Scientific Instruments,
Volume 45,
Issue 11,
1974,
Page 1476-1478
W. P. Boyle,
Preview
|
PDF (261KB)
|
|
摘要:
A differential pressure sensor is described. This instrument is capable of resolving pressure changes of about 3.0 kN/m2in ambient pressures of up to 1.0 GN/m2. The instrument is of the deflecting diaphragm type with the movement being measured by an inductive transducer.
ISSN:0034-6748
DOI:10.1063/1.1686540
出版商:AIP
年代:1974
数据来源: AIP
|