411. |
Present status of the SORTEC SR Facility |
|
Review of Scientific Instruments,
Volume 63,
Issue 1,
1992,
Page 1611-1612
N. Atoda,
N. Awaji,
M. Kodaira,
T. Kishimoto,
J. Nishino,
K. Koga,
Y. Maejima,
I. Higashigawa,
K. Yanagida,
Preview
|
PDF (263KB)
|
|
摘要:
The status and performance of the SORTEC SR facility is described. Emphasis is placed on the reliable operation and the high performance of the SR source and the status of major systems for x‐ray lithography.
ISSN:0034-6748
DOI:10.1063/1.1142992
出版商:AIP
年代:1992
数据来源: AIP
|
412. |
The Synchrotron Radiation Facility at Frascati |
|
Review of Scientific Instruments,
Volume 63,
Issue 1,
1992,
Page 1613-1614
R. Cimino,
E. Burattini,
S. Mobilio,
Preview
|
PDF (287KB)
|
|
摘要:
In this paper we give a brief description of the Synchrotron Radiation Facility at Frascati. Particular emphasis is given in describing the most significant instrument developments during the last few years.
ISSN:0034-6748
DOI:10.1063/1.1142993
出版商:AIP
年代:1992
数据来源: AIP
|
413. |
The ELETTRA Synchrotron Radiation Facility |
|
Review of Scientific Instruments,
Volume 63,
Issue 1,
1992,
Page 1615-1616
R. P. Walker,
Preview
|
PDF (291KB)
|
|
摘要:
The present status of the ELETTRA Synchrotron Radiation Facility, under construction in Trieste, Italy, is described.
ISSN:0034-6748
DOI:10.1063/1.1142994
出版商:AIP
年代:1992
数据来源: AIP
|
414. |
TELL‐TERAS, NIJI‐I, II, III, IV, and positron facilities |
|
Review of Scientific Instruments,
Volume 63,
Issue 1,
1992,
Page 1617-1620
Takio Tomimasu,
Preview
|
PDF (533KB)
|
|
摘要:
The installation of the experimental facilities, TELL, TERAS, NIJI‐III, NIJI‐IV and slow position and pion facilities is disscused. The beam characterics from the storage rings is also discussed. (AIP)
ISSN:0034-6748
DOI:10.1063/1.1142995
出版商:AIP
年代:1992
数据来源: AIP
|
415. |
Synchrotron radiation from the Amsterdam Pulse Stretcher (AmPS) |
|
Review of Scientific Instruments,
Volume 63,
Issue 1,
1992,
Page 1621-1622
Guy Luijckx,
Rob Maas,
Preview
|
PDF (240KB)
|
|
摘要:
The National Institute for Nuclear Physics and High‐Energy Physics NIKHEF is constructing AmPS, a pulse stretcher ring, as an extension to its existing electron linac facility. The project is primarily funded to produce continuous electron beams for nuclear physics experiments. The first beam for nuclear physics experiments is expected by mid 1992. AmPS is designed for energies between 300 and 1000 MeV and circulating currents up to 200 mA. Synchrotron radiation will be generated in each of the 32 bending magnets of the ring. At least two of its long straights are well suited to install either wavelength shifters (wigglers) and/or undulators. For nuclear physics AmPS will be operated for 2500 hours per year, an additional 2000 hours per year for dedicated SR use seems feasible. AmPS will provide SR beams from the VUV to the soft x‐ray region; with appropriate insertion devices extension is possible up to the medium energy x‐ray region. Its SR brilliance can be made fully competitive with new generation sources by adding 32 quadrupoles to its lattice.
ISSN:0034-6748
DOI:10.1063/1.1142996
出版商:AIP
年代:1992
数据来源: AIP
|
416. |
Summary of the satellite workshop on thermal problems of synchrotron radiation optics |
|
Review of Scientific Instruments,
Volume 63,
Issue 1,
1992,
Page 1623-1624
Andreas K. Freund,
Dennis M. Mills,
Preview
|
PDF (311KB)
|
|
摘要:
Highlights of a workshop on thermal problems of synchrotron radiation optics, a satellite meeting of the 4th International Conference on Synchrotron Radiation Instrumentation, will be presented. The most recent theoretical concepts and experimental results in studies of the thermal distortion of components exposed to the high heat loads of synchrotron radiation were discussed. Presentations were made on a variety of cooling techniques such as adaptive optical components, cryogenic cooling, nonstandard geometries (e.g., thin crystals and inclined crystals), and specialized materials (e.g., beryllium single crystals and multilayers), all of which attempt to mitigate the thermal effects on the performance of the x‐ray optical components.
ISSN:0034-6748
DOI:10.1063/1.1142997
出版商:AIP
年代:1992
数据来源: AIP
|
417. |
Report of the satellite workshop on synchrotron radiation instrumentation for x‐ray absorption spectroscopy |
|
Review of Scientific Instruments,
Volume 63,
Issue 1,
1992,
Page 1625-1627
G. N. Greaves,
Preview
|
PDF (378KB)
|
|
摘要:
Report of a workshop on synchrotron radiation instrumentation for x−ray absorption spectroscopy, a satellite meeting of the 4th International Conference on Synchrotron Radiation Instrumentation, will be presented. The workshop comprised presentations and discussions in the principal areas of x−ray optics, sources of noise, detectors and new experiments. (AIP)
ISSN:0034-6748
DOI:10.1063/1.1142998
出版商:AIP
年代:1992
数据来源: AIP
|
418. |
Synchrotron radiation instrumentation and macromolecular crystallography |
|
Review of Scientific Instruments,
Volume 63,
Issue 1,
1992,
Page 1628-1629
J. R. Helliwell,
Preview
|
PDF (244KB)
|
|
摘要:
Highlights of a workshop on synchrotron radiation intrumentation and macromolecular crystallography, a satellite meeting of the 4th International Conference on Synchrotron Radiation Instrumentation, will be presented. The theme of the meeting was to look towards the developments on the next generation of high brilliance SR sources current under construction. Macromolecular crystallography needs span a very wide range of technical requirments covering the most demanding uses of SR. It is a rapidly expanding field. (AIP)
ISSN:0034-6748
DOI:10.1063/1.1142999
出版商:AIP
年代:1992
数据来源: AIP
|
|