1. |
The Construction and Cooling of Large Vapor Traps |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 207-210
D. L. Northrup,
C. M. Van Atta,
L. C. Van Atta,
Preview
|
PDF (245KB)
|
|
摘要:
A description is given of a simple and efficient baffle system which results in a vapor trap of high conductance for permanent gas. Two methods for maintaining the temperature of the trap in the range −50° to −80°C are described, one designed for intermittent and one for continuous operation. Measured conductances and over‐all performance characteristics are given.
ISSN:0034-6748
DOI:10.1063/1.1751686
出版商:AIP
年代:1940
数据来源: AIP
|
2. |
A Circuit for the Rapid Measurement of the Power Factor of Condensers |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 210-211
Eric A. Walker,
Preview
|
PDF (120KB)
|
|
摘要:
A rugged, simple, and inexpensive circuit is described which enables one to ascertain rapidly the power factor and capacitance of condensers. With minor changes the circuit can be used to determine the magnitude and angle of any impedance.
ISSN:0034-6748
DOI:10.1063/1.1751687
出版商:AIP
年代:1940
数据来源: AIP
|
3. |
A Mass Spectrometer for Routine Isotope Abundance Measurements |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 212-216
Alfred O. Nier,
Preview
|
PDF (317KB)
|
|
摘要:
A mass spectrometer suitable for routine isotope analyses of carbon, nitrogen, and other light elements which may be put in the gaseous or vapor form is described. Although a simple, relatively inexpensive magnet consuming little power is used, good resolution is obtained.
ISSN:0034-6748
DOI:10.1063/1.1751688
出版商:AIP
年代:1940
数据来源: AIP
|
4. |
Work's Method for Balancing the Kelvin Double Bridge |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 217-219
G. R. Patterson,
Preview
|
PDF (165KB)
|
|
摘要:
The Kelvin double bridge for measuring low resistances usually is balanced by either variable ratio arms or by a variable standard resistor. For the calibration of fixed value standard resistors when the major ratio arms and the bridge standard are fixed value precision standards, Work's method obtains the balance of the bridge by passing an adjustable auxiliary current through the standard.
ISSN:0034-6748
DOI:10.1063/1.1751689
出版商:AIP
年代:1940
数据来源: AIP
|
5. |
A Precision Spectrophotometer for Use in the Range 450 to 820 m&mgr; |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 220-226
S. Jacobsohn,
H. E. Bent,
A. J. Harrison,
Preview
|
PDF (437KB)
|
|
摘要:
A precision photoelectric spectrophotometer is described which illuminates absorption cells with light which has passed through two monochromators, the half‐intensity width of the spectral region isolated being from 5 to 10 m&mgr;. Cells 20 cm long and as much as 14 cm in diameter may be used when it is necessary to work at low or high temperatures with thermostated equipment. The detector is a null instrument, giving a sensitivity of 0.0001I0and an accuracy under favorable conditions in the optical density of 0.1 percent.
ISSN:0034-6748
DOI:10.1063/1.1751690
出版商:AIP
年代:1940
数据来源: AIP
|
6. |
Photo‐Cell Multiplier Tubes |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 226-229
C. C. Larson,
H. Salinger,
Preview
|
PDF (263KB)
|
|
摘要:
Structural and performance data on a Cs&sngbnd;Cs2O&sngbnd;Ag type of photoelectric cell whose current output is amplified by an integral 6‐ or 11‐stage electron multiplier are given.
ISSN:0034-6748
DOI:10.1063/1.1751691
出版商:AIP
年代:1940
数据来源: AIP
|
7. |
Notes on the Wettability of Highly Polished Metal Surfaces by Graphite Hydrosols |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 230-231
Raymond Szymanowitz,
Bernard H. Porter,
Preview
|
PDF (118KB)
|
|
摘要:
Investigation shows that a straight line relationship exists between the concentration of aqueous colloidal graphite and the minimum temperature at which it will wet unclean, highly polished surfaces of metal. Surfaces cleaned with metallographic powder and water are wetted by this type of dispersion at room temperature.
ISSN:0034-6748
DOI:10.1063/1.1751692
出版商:AIP
年代:1940
数据来源: AIP
|
8. |
The Lining of Metal Capillaries with Glass and the Application to a Capillary Positive Ion Source |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 232-234
I. A. Getting,
H. W. Leighton,
Preview
|
PDF (177KB)
|
|
摘要:
A technique is described for the lining of metal capillaries with a thin coat of glass. The advantages of such capillaries in electrical discharges are pointed out. Use is made of such a capillary in a highly efficient positive ion source for high voltage nuclear research.
ISSN:0034-6748
DOI:10.1063/1.1751693
出版商:AIP
年代:1940
数据来源: AIP
|
9. |
A Vacuum Interferometer for Precise Measurements |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 235-236
R. M. Elliott,
Preview
|
PDF (93KB)
|
|
摘要:
The serious effect of pressure and temperature variations in the use of a Fabry‐Perot interferometer is outlined, together with a method successfully employed to reduce these variations to a reasonable limit.
ISSN:0034-6748
DOI:10.1063/1.1751694
出版商:AIP
年代:1940
数据来源: AIP
|
10. |
A Note on the Paralysis of Sub‐Threshold Counters |
|
Review of Scientific Instruments,
Volume 11,
Issue 7,
1940,
Page 237-238
C. G. Montgomery,
D. D. Montgomery,
Preview
|
|
ISSN:0034-6748
DOI:10.1063/1.1751697
出版商:AIP
年代:1940
数据来源: AIP
|