1. |
Fast Neutron Time‐of‐Flight Spectrometer |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 963-975
G. C. Neilson,
W. K. Dawson,
F. A. Johnson,
Preview
|
PDF (783KB)
|
|
摘要:
A versatile neutron time‐of‐flight spectrometer suitable for use in the millimicrosecond region is described. Either the rf beam deflection method or the gamma coincidence method is used to provide the zero time indication. Details of these methods, along with spectra obtained for some (d,n) reactions, are given. The two systems are compatible and make use of the same simple time‐to‐pulse‐height converter. The dependence of the decay time of a liquid scintillator on the specific ionization of the detected particle has been used to make the neutron detector insensitive to gamma‐rays.
ISSN:0034-6748
DOI:10.1063/1.1716441
出版商:AIP
年代:1959
数据来源: AIP
|
2. |
Automatic Recording Film Balance System |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 975-981
H. J. Trurnit,
W. E. Lauer,
Preview
|
PDF (653KB)
|
|
摘要:
An automatic recording film balance system is described. It consists of a film trough and two pendulum type balances with pressure ranges of 0–400 (800) millidynes/cm and 0–40 (80) dynes/cm, respectively. Each balance is connected to a float when in operation (Langmuir type balance) and the sensing element in both cases is a linear variable differential transformer, the iron core of which is connected to the pendulum. The transformer signal after amplification drives the pen motor of a strip chart recorder. Special features like a constant pressure device together with auxiliary instruments such as a second X‐Y recorder, an automatic dipping device for film transfer, a volta potential meter and a slit viscosimeter permit the automatic recording of the following functions:dFdAT, dAdTF, dFdTA, dFdtT, A, dAdtT, F, AwAsT, F, dVdFT, and d&eegr;dFT.F=film pressure,A=film area,T=temperature,t=time,Aw/As=deposition ratio, &eegr;=film viscosity, andV=volta potential. Test and performance data are presented.
ISSN:0034-6748
DOI:10.1063/1.1716442
出版商:AIP
年代:1959
数据来源: AIP
|
3. |
Techniques for Handling Metallic Whiskers |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 982-983
Ethel L. Fontanella,
R. W. DeBlois,
Preview
|
PDF (155KB)
|
|
摘要:
Detailed descriptive methods are presented for the selection, removal, and preparation for experimental use of both iron and copper whiskers. Techniques which minimize damage are emphasized.
ISSN:0034-6748
DOI:10.1063/1.1716443
出版商:AIP
年代:1959
数据来源: AIP
|
4. |
Liquid Hydrogen Targets of Adhesive‐Bonded Mylar Plastic |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 983-985
Roy S. Hickman,
Robert W. Kenney,
Robert C. Mathewson,
Richard A. Perkins,
Preview
|
PDF (261KB)
|
|
摘要:
Vacuum‐tight cryogenic containers can easily be made from Mylar plastic sheet and metal, or from Mylar alone, for use in vacuum‐insulated liquid hydrogen target assemblies. Mylar is bonded very firmly to metals or to itself by an Epon‐Versamid mixture or by Armstrong A‐4. These adhesives maintain strong vacuum‐tight joints throughout the temperature range from 300 to 4°K. Mylar sheet has also proved satisfactory as vacuum‐window material for beam ports. Fabrication of these structures is described in detail, and explosion safety measures are mentioned. Some examples are given of structures which have been used or tested, with data on the ultimate strength of each expressed as the internal pressure required to rupture it. Helium leak testing must be carried out at 77°K or below, because Mylar is relatively impermeable to helium only at low temperatures. The primary electron beams commonly obtained from electron linear accelerators are sufficiently intense to cause Mylar beam windows to fail under vacuum loading, probably because of radiation damage. However, the authors know of no case of radiation damage to Mylar sustained in exposure to secondary beams from high‐energy accelerators.
ISSN:0034-6748
DOI:10.1063/1.1716444
出版商:AIP
年代:1959
数据来源: AIP
|
5. |
External Beam Current Monitor for Linear Accelerators |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 985-988
L. Bess,
J. Ovadia,
J. Valassis,
Preview
|
PDF (288KB)
|
|
摘要:
An electron current monitor for linear accelerators has been developed. Its sensing element was a toroidal coil through which the beam passes undisturbed. With appropriate electronic circuity this permitted the true shape of the current pulse to be viewed and also provided an indication of the average beam current on a meter. The average beam current that could be measured ranged from 3×10−8to 3×10−6amp. Furthermore, the use of the current monitor greatly simplified the process of initially obtaining yield from the machine.
ISSN:0034-6748
DOI:10.1063/1.1716445
出版商:AIP
年代:1959
数据来源: AIP
|
6. |
High‐Pressure Microwave Window |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 989-991
A. W. Lawson,
George E. Smith,
Preview
|
PDF (208KB)
|
|
摘要:
Two conically tapered single crystals of Al2O3, with small ends abutting, are used to simultaneously effect a high pressure seal and provide a matched transformation from a standard 1‐cm circular wave guide at atmospheric pressure to a circular wave guide terminated by a high‐Q cavity resonator with an internal hydrostatic pressure up to 104bars.
ISSN:0034-6748
DOI:10.1063/1.1716446
出版商:AIP
年代:1959
数据来源: AIP
|
7. |
Time Analyzer Utilizing the Argonne Type 256‐Channel Pulse‐Height Analyzer |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 991-994
J. F. Whalen,
J. W. Meadows,
C. H. Nelson,
Preview
|
PDF (291KB)
|
|
摘要:
A time analyzer has been designed which is capable of utilizing the memory of any multichannel analyzer which employs pulse height to time conversion or any similar instrument. The circuit described here has been specifically adapted for use with the Argonne type 256‐channel analyzer. Channel widths from 1 &mgr;sec to >38 &mgr;sec are possible with a minimum dead time of 38 &mgr;sec.
ISSN:0034-6748
DOI:10.1063/1.1716447
出版商:AIP
年代:1959
数据来源: AIP
|
8. |
Solid‐State, High‐Intensity Monochromatic Light Sources |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 995-996
Irwin Wieder,
Preview
|
PDF (153KB)
|
|
摘要:
The extension of optical pumping techniques to solids has been hampered by the lack of suitable light sources. The utilization of photoluminescent effects is proposed as a method for obtaining light sources applicable to optical pumping experiments in some solids, and a ruby source which emits 0.1 w of light at 6934 A and 6920 A is described.
ISSN:0034-6748
DOI:10.1063/1.1716448
出版商:AIP
年代:1959
数据来源: AIP
|
9. |
Automatic Control and Programing System for Single Crystal Diffractometry |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 997-1003
F. Langdon,
B. C. Frazer,
Preview
|
PDF (522KB)
|
|
摘要:
An automatic control and programing system for the collection of single crystal diffraction data is described. The system has been designed for a neutron diffractometer, but it could easily be adapted for use with x‐rays.
ISSN:0034-6748
DOI:10.1063/1.1716449
出版商:AIP
年代:1959
数据来源: AIP
|
10. |
Millimicrosecond Discriminator |
|
Review of Scientific Instruments,
Volume 30,
Issue 11,
1959,
Page 1004-1006
David F. Swift,
Victor Perez‐Mendez,
Preview
|
PDF (187KB)
|
|
摘要:
A discriminator circuit for use with millimicrosecond counting equipment is described here. The circuit utilizes a diode voltage comparator which drives a secondary‐emission tube univibrator after amplification. Two shaped outputs are provided: one, of short duration, for use with 10‐Mc scalers, and another longer pulse for microsecond scalers.The main characteristics of this unit are its good response to pulses as short as 3 m &mgr;sec and the fast recovery time, which is less than 0.1 &mgr;sec at the fast output.
ISSN:0034-6748
DOI:10.1063/1.1716403
出版商:AIP
年代:1959
数据来源: AIP
|
|