1. |
Full and Partial Particle Replication Technique for Electron Microscopy |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1181-1185
F. Leonhard,
C. F. Cook,
F. R. Anderson,
Preview
|
PDF (467KB)
|
|
摘要:
The state of the art, and the principal problems of particle replication techniques have been reviewed. The objective was to obtain the highest reliability as well as the maximum geometrical and contrast resolution for the replication technique. To this end, further improvements and complementary developments of the now‐known techniques of particle replication were made. The essential stages consist of: (1) preshadowing of the sample by a refractory alloy (Pt:10%Rh) evaporated in high vacuum from a carbon rod; (2) utilizing a residual gas scattering evaporation technique (carbon in an argon atmosphere of 10−3mm Hg) at twice the mean free path of the carbon (this forms a thin uniform carbon coating layer as a supporting layer which gives a minimum of contrast in the electron microscope); (3) utilizing an auxiliary strengthening layer of a subliming material (sulfur) to protect effectively the replica from deformation or fracture during the preparation procedure (the auxiliary layer can later be removed by sublimation); (4) development of an easy to do partial‐particle replication technique, utilizing a thermoplastic embedding technique to restrict replication to only one side of a particle which will give superposition free images.
ISSN:0034-6748
DOI:10.1063/1.1716846
出版商:AIP
年代:1960
数据来源: AIP
|
2. |
On the Use of 2N504 Transistors in the Avalanche Mode for Nuclear Instrumentation |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1186-1189
Ralph Fullwood,
Preview
|
PDF (244KB)
|
|
摘要:
Philco 2N501, 2N502, and 2N504 transistors have been operated successfully in the avalanche mode as fast discriminators on photomultiplier tubes and as the pulse generating element in pulse generators. They exhibit the property of a fast rise time (≲1 nsec) and sharp discriminating characteristics but have the disadvantage of a long recovery time (∼80 nsec).
ISSN:0034-6748
DOI:10.1063/1.1716847
出版商:AIP
年代:1960
数据来源: AIP
|
3. |
An Analysis of the Circuit of Dauphinee and Mooser for Measuring Resistivity and Hall Constant |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1189-1192
L. J. V. D. Pauw,
Preview
|
PDF (244KB)
|
|
摘要:
The Dauphinee and Mooser circuit [Rev. Sci. Instr.26, 660 (1955)] for the measurement of resistivity and the Hall effect is liable to certain systematic errors due to capacitive effects in the switches. The magnitude of these errors is estimated, and it is shown how they may be eliminated by the use of suitably placed trimming capacitors and by a suitable switching sequence. The sensitivity of the circuit is also calculated.
ISSN:0034-6748
DOI:10.1063/1.1716848
出版商:AIP
年代:1960
数据来源: AIP
|
4. |
Efficient Production of Multiply Charged Positive Ions by Low Energy Stripping in Helium Gas |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1193-1197
S. K. Allison,
J. Cuevas,
M. Garcia‐Munoz,
Preview
|
PDF (393KB)
|
|
摘要:
``Low energy'' as used in this report means ionic and atomic beam velocities from approximately 5×107to 2×108cm/sec. In this velocity region an ion beam brought to charge equilibrium in helium gas has a much greater content of components of high positive charge than does the same beam charge equilibrated in other gases. To achieve this effect, however, the pressure of helium gas in a charge stripper or converter cell placed in the beam path must be much higher than in other gases. The predicted effect, calculated from the charge changing cross sections, is verified by experiments on the stripping of Li+to Li++in air and helium. In a qualitative experiment the proton beam of the Chicago synchrocyclotron was increased 100% by equilibrating the hydrogen constituent in a 90–10 HeH2mixture before issuing it from the ion source into the acceleration chamber.
ISSN:0034-6748
DOI:10.1063/1.1716849
出版商:AIP
年代:1960
数据来源: AIP
|
5. |
Improved “Twin” Scintillation Fast Neutron Detector |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1198-1200
I. B. Berlman,
R. Grismore,
B. G. Oltman,
Preview
|
PDF (233KB)
|
|
摘要:
Improvements are presented in the use of the ``twin'' scintillation detector described in an earlier paper. Conditions are specified under which the fluorescence yield is maximized and the proton to electron ratio equalized in both solutions. For a neutron energy of 2.19 Mev the instrumental line width is 23%. The estimated lower limit of its potential range is ¼ to ⅓ mev. Other improvements in sensitivity have permitted the measurement of background neutron fluxes of the order of those produced by cosmic rays.
ISSN:0034-6748
DOI:10.1063/1.1716850
出版商:AIP
年代:1960
数据来源: AIP
|
6. |
High Temperature Mass Spectrometer Sample System |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1200-1202
H. M. Shin,
H. K. Hahm,
S. I. Kwon,
S. H. Jo,
S. B. Hong,
Preview
|
PDF (202KB)
|
|
摘要:
A General Electric analytical mass spectrometer, which was originally designed only for gaseous samples, has been modified so that the sample system can be converted for application to solid samples at elevated temperatures up to 1000°C. Conversion is accomplished by the complete replacement of the sample system by a magnetically operated device and a cavity furnace, the heater of which is thermally attached to the furnace body and servo‐controlled to keep to the predetermined temperature within a fraction of a degree. The furnace body is a silica tube, 5 mm i.d. Replacement of the sample can be done within 10 min without breaking the major vacuum. Advantages and disadvantages compared to the Knudsen cell are also discussed.
ISSN:0034-6748
DOI:10.1063/1.1716851
出版商:AIP
年代:1960
数据来源: AIP
|
7. |
Low Scatter High Current Gas Target for D‐D Neutrons |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1202-1203
Allan C. B. Richardson,
Preview
|
PDF (103KB)
|
|
摘要:
A target for the production of neutrons by the D(d,n) He3reaction is described. The target gas is circulated to cool the foils used as entrance and exit windows for the incident deuteron beam. Low mass construction is employed to minimize the scattering of neutrons.
ISSN:0034-6748
DOI:10.1063/1.1716852
出版商:AIP
年代:1960
数据来源: AIP
|
8. |
Measurement of Ratio of Absorptivity of Sunlight to Thermal Emissivity |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1204-1208
G. D. Gordon,
Preview
|
PDF (328KB)
|
|
摘要:
Direct measurements of the ratio of the surface absorptivity of sunlight to the thermal emissivity have been made, and the apparatus is described. A thin plate to be measured is suspended in a vacuum, surrounded by walls cooled by liquid nitrogen, and illuminated by an arc light, which simulates solar radiation. The desired ratio is determined from the equilibrium temperature, which ranged from 0° to 250°C for the samples measured. Possible errors in the procedure have been analyzed theoretically, and corrections introduced where necessary. Intensity fluctuations in the present light source have limited the accuracy to 10%, but this is not a fundamental limitation in the method. Values of the thermal emissivity are also obtained from the rate of change of sample temperature.
ISSN:0034-6748
DOI:10.1063/1.1716853
出版商:AIP
年代:1960
数据来源: AIP
|
9. |
Fast Transistorized Time‐to‐Pulse‐Height Converter |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1209-1214
G. Culligan,
N. H. Lipman,
Preview
|
PDF (389KB)
|
|
摘要:
A transistorized time‐to‐pulse‐height converter is described which has a timebase range of 0 to 15 nsec, and a stability of 10−10sec. The circuit has been used for the mass analysis of particle beams by time‐of‐flight. Time resolutions of 10−9sec were obtained using conventional scintillation counters. The circuit has a short dead time (3×10−7sec), contains a gating facility, but is of simple design. It has been in use at CERN for the previous six months, and functions satisfactorily under experimental conditions.
ISSN:0034-6748
DOI:10.1063/1.1716854
出版商:AIP
年代:1960
数据来源: AIP
|
10. |
Capacitance Transducers for Muscle Research |
|
Review of Scientific Instruments,
Volume 31,
Issue 11,
1960,
Page 1215-1217
Myron O. Schilling,
Preview
|
PDF (226KB)
|
|
摘要:
Apparatus has been developed for the measurement of shortening and tension of isolated muscle using variable capacitance methods. An isotonic transducer is described which will measure up to 2.5 cm of shortening with a minimum of inertial loading with 1% linearity. An isometric transducer is described which will measure tensions up to 100 g with not more than 5‐&mgr; displacement from 0 to 200 cycles/sec. Simple modifications provide other ranges of tension.
ISSN:0034-6748
DOI:10.1063/1.1716855
出版商:AIP
年代:1960
数据来源: AIP
|