1. |
AWARD OF PRIZE FOR 1930 |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 513-513
Preview
|
PDF (41KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748817
出版商:AIP
年代:1931
数据来源: AIP
|
2. |
AN IMPROVED McLEOD GAUGE |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 514-518
Samuel D. Bryden,
Preview
|
PDF (235KB)
|
|
摘要:
A ``short form'' of McLeod gauge has been designed and built which is believed to be an improvement over the conventional constructions. These improvements consist of a simplified and compact construction of the compression chamber and mercury cistern, and of the entrance of the tubing connecting the gauge with the vacuum system directly through the top of the compression chamber.The actual construction is shown by a drawing and photograph.The theory of the McLeod gauge is briefly considered and the possible advantages of combining a controlled compression or expansion chamber with several existing gauges are indicated.
ISSN:0034-6748
DOI:10.1063/1.1748818
出版商:AIP
年代:1931
数据来源: AIP
|
3. |
Compton Electrometer Suspension |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 518-518
A. H. Cox,
Preview
|
PDF (24KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748819
出版商:AIP
年代:1931
数据来源: AIP
|
4. |
A VACUUM TUBE RELAY AND RACE TIMER |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 519-521
W. M. Roberds,
Preview
|
PDF (104KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748820
出版商:AIP
年代:1931
数据来源: AIP
|
5. |
APPLICATIONS OF THE SCHLIEREN METHOD OF PHOTOGRAPHY |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 522-531
D. B. Gawthrop,
Preview
|
PDF (505KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748821
出版商:AIP
年代:1931
数据来源: AIP
|
6. |
A METHOD OF OBTAINING A LINEAR TIME AXIS FOR A CATHODE RAY OSCILLOGRAPH |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 532-540
A. L. Samuel,
Preview
|
PDF (313KB)
|
|
摘要:
The usefulness of a cathode ray oscillograph tube of the type of the Western Electric No. 224‐B is enhanced by any circuit that will provide a linear time axis. A number of methods of accomplishing this result have been described from time to time. One method used in the Bell Telephone Laboratories employs a hot‐cathode three‐element gas‐filled tube in the usual ``sweep'' circuit. This method possesses advantages in reproducibility, ease of control and synchronization. A brief description of the tube is given together with a simple analysis of the behavior of the circuit. Methods of coupling the sweep circuit to the oscillograph tube, of synchronizing the sweep frequency and of improving the linearity are discussed. A complete portable laboratory oscillograph outfit is shown as an illustration of one form that the device may assume. This set is for use within the audible frequency range.
ISSN:0034-6748
DOI:10.1063/1.1748822
出版商:AIP
年代:1931
数据来源: AIP
|
7. |
A THROUGH TYPE CURRENT TRANSFORMER AND AMPLIFIER FOR MEASURING ALTERNATING CURRENTS OF A FEW MILLIAMPERES |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 541-548
W. B. Kouwenhoven,
Preview
|
PDF (291KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748823
出版商:AIP
年代:1931
数据来源: AIP
|
8. |
A HIGH POWER SOURCE OF CONTINUOUS ULTRAVIOLET SPECTRUM |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 549-550
G. B. Kistiakowsky,
Preview
|
PDF (89KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748824
出版商:AIP
年代:1931
数据来源: AIP
|
9. |
A METHOD OF MEASURING THE INTEGRATED LIGHT FROM SHORT FLASHES OF HIGH INTENSITY |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 551-553
Lewis R. Koller,
Preview
|
PDF (96KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748825
出版商:AIP
年代:1931
数据来源: AIP
|
10. |
SOME ASPECTS OF PROGRESSIVE IMPROVEMENT IN THE SCREW THREAD |
|
Review of Scientific Instruments,
Volume 2,
Issue 9,
1931,
Page 554-570
William E. Hoke,
Preview
|
PDF (899KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748826
出版商:AIP
年代:1931
数据来源: AIP
|