1. |
Editorial |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 479-479
J. B. H. K.,
Preview
|
PDF (26KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1717417
出版商:AIP
年代:1961
数据来源: AIP
|
2. |
FOREWORD |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 480-480
Keith R. Symon,
Preview
|
PDF (58KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1717418
出版商:AIP
年代:1961
数据来源: AIP
|
3. |
CONTENTS |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 481-481
Preview
|
PDF (33KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1717419
出版商:AIP
年代:1961
数据来源: AIP
|
4. |
Development of the Spark Chamber: A Review |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 482-485
Arthur Roberts,
Preview
|
PDF (319KB)
|
|
摘要:
A survey of the development of the spark chamber from the spark counter is given. An effort has been made to clarify the early history of the device. Some unpublished recent Russian work on spark chambers is summarized. A consistent terminology for the various times relevant to spark chamber operation is suggested.
ISSN:0034-6748
DOI:10.1063/1.1717420
出版商:AIP
年代:1961
数据来源: AIP
|
5. |
Discussion |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 486-498
Preview
|
PDF (868KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1717421
出版商:AIP
年代:1961
数据来源: AIP
|
6. |
Observations on Pulsed Spark Chambers |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 499-508
Joachim Fischer,
Gus T. Zorn,
Preview
|
PDF (753KB)
|
|
摘要:
The spark formation time in rare‐gas pulsed spark chambers was investigated as a function of the pulse voltage under various conditions of electrodes, gap lengths, gases, delay times, and clearing fields. An explanation of these formation times was found in terms of a simple process of electron multiplication leading to rapid gas breakdown. Notes on the construction of a thin foil spark chamber and on thyratron pulsers for use with spark chambers are also given.
ISSN:0034-6748
DOI:10.1063/1.1717422
出版商:AIP
年代:1961
数据来源: AIP
|
7. |
Discussion |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 509-511
Preview
|
PDF (207KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1717423
出版商:AIP
年代:1961
数据来源: AIP
|
8. |
A 14×14×7‐in. Thin Plate Spark Chamber |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 512-515
Donald I. Meyer,
Kent M. Terwilliger,
Preview
|
PDF (267KB)
|
|
摘要:
A Lucite wall spark chamber with 0.012‐in. aluminum electrodes, active dimensions 14×14×7 in., has been constructed and tested both with cosmic rays and a particle beam. The gap efficiency is nearly 100% and the time resolution ∼1 &mgr;sec. Construction methods and chamber characteristics are presented.
ISSN:0034-6748
DOI:10.1063/1.1717424
出版商:AIP
年代:1961
数据来源: AIP
|
9. |
Further Discussion on Methods of Construction |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 516-518
Preview
|
PDF (190KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1717425
出版商:AIP
年代:1961
数据来源: AIP
|
10. |
Accuracy of Track Location in Spark Chambers. I |
|
Review of Scientific Instruments,
Volume 32,
Issue 5,
1961,
Page 519-521
J. G. Rutherglen,
J. M. Paterson,
Preview
|
PDF (154KB)
|
|
摘要:
Several spark chambers with a sensitive area of about 6×6 in. have been constructed using 0.005‐in. aluminum plates and 0.25‐in. glass frames as spacers. These were tested with cosmic rays, using neon, argon, and neon‐argon mixtures as the filling gas. A spark gap triggered by scintillation counters was used to apply a high voltage pulse to the plates. Photographs of the sparks produced were analyzed to determine the accuracy with which the track of the cosmic ray could be located. It was found that the electrons nearest the negative clectrode are the ones which determine the position of the spark. The results give a basis on which to design a spark chamber system to give any desired accuracy of track location and direction.
ISSN:0034-6748
DOI:10.1063/1.1717426
出版商:AIP
年代:1961
数据来源: AIP
|