1. |
Editorial |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 519-520
Preview
|
PDF (130KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748986
出版商:AIP
年代:1933
数据来源: AIP
|
2. |
The Physics of Solids |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 520-523
B. E. Warren,
Preview
|
PDF (277KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748987
出版商:AIP
年代:1933
数据来源: AIP
|
3. |
Professor Born's Theory of the Electron |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 524-524
E. L. Hill,
Preview
|
PDF (71KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748988
出版商:AIP
年代:1933
数据来源: AIP
|
4. |
Optical Properties of the Alkali Metals |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 525-526
E. L. Hill,
Preview
|
PDF (99KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748989
出版商:AIP
年代:1933
数据来源: AIP
|
5. |
An Adaptation of the Interferometer for Hyperfine Structure |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 527-528
George S. Monk,
Preview
|
PDF (57KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748990
出版商:AIP
年代:1933
数据来源: AIP
|
6. |
A New Type of Crystal Structure Model |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 529-529
George Glockler,
Preview
|
PDF (56KB)
|
|
ISSN:0034-6748
DOI:10.1063/1.1748991
出版商:AIP
年代:1933
数据来源: AIP
|
7. |
A New Wave‐Length Comparator |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 530-531
George Glockler,
F. W. Fullerton,
Preview
|
PDF (79KB)
|
|
摘要:
A wave‐length comparator has been constructed, in which the microscope moves along the direction of the measuring screw and the platform carrying the photographic plate has an independent motion at right angles to the direction of the screw. A split nut which is part of the microscope carriage permits release from the screw and a quick motion of the microscope from one end of the photographic plate to the other.
ISSN:0034-6748
DOI:10.1063/1.1748992
出版商:AIP
年代:1933
数据来源: AIP
|
8. |
An Improved d.c. Amplifying Circuit |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 532-536
Lee A. DuBridge,
Hart Brown,
Preview
|
PDF (250KB)
|
|
摘要:
The sensitivity of d.c. amplifying circuits with FP‐54 tubes is limited by the stability which can be obtained. In single‐tube circuits it is necessary to balance out fluctuations caused by changes in battery e.m.f. and in filament emission. Soller's circuit for balancing out e.m.f. changes has been studied in detail and a modified circuit has been developed in which the adjustments are less critical and which allows balancing out of changes in filament emission also. The latter is accomplished by balancing the plate current against the current to the space‐charge grid. Details of construction and manipulation of the new circuit are given, as well as data on its stability.
ISSN:0034-6748
DOI:10.1063/1.1748993
出版商:AIP
年代:1933
数据来源: AIP
|
9. |
A New Radiofrequency Phase Meter |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 537-539
R. R. Law,
Preview
|
PDF (161KB)
|
|
摘要:
A new type radiofrequency phase meter, wherein the original voltages to be studied are heterodyned to convenient audiofrequencies for phase measurement, is described. By heterodyning both above and below the frequencies of the voltages being tested, the effects of undesired phase shifts within the apparatus are eliminated. Circuit constants which have given satisfactory results in practice are included. Accuracies of one‐tenth degree on angles up to ten degrees are readily attained at frequencies of 106cycles per second.
ISSN:0034-6748
DOI:10.1063/1.1748994
出版商:AIP
年代:1933
数据来源: AIP
|
10. |
An Electrostatic Generating Voltmeter |
|
Review of Scientific Instruments,
Volume 4,
Issue 10,
1933,
Page 540-541
G. P. Harnwell,
S. N. Van Voorhis,
Preview
|
PDF (131KB)
|
|
摘要:
An electrostatic generating voltmeter is described which has a strictly linear scale, which has no commutators, and whose calibration is substantially independent of the speed of the driving motor and of the characteristics of the associated vacuum tube amplifier. A means of calibration by use of a wire grid in front of the voltmeter is also described.
ISSN:0034-6748
DOI:10.1063/1.1748995
出版商:AIP
年代:1933
数据来源: AIP
|