11. |
Simple Measurement of Isepamicin, a New Aminoglycoside Antibiotic, in Guinea Pig and Human Plasma, Using High‐Performance Liquid Chromatography with Ultraviolet Detection |
|
Therapeutic Drug Monitoring,
Volume 13,
Issue 1,
1991,
Page 73-78
Silvio Dionisotti,
Francesco Bamonte,
Franco Scaglione,
Ennio Ongini,
Preview
|
PDF (446KB)
|
|
摘要:
Isepamicin, the 1-N-(S-alpha-hydroxy-beta-aminopropionyl) derivative of gentamicin B, is a new aminoglycoside antibiotic, which not only has most of the properties of amikacin but also is effective against several amika-cin-resistant strains of bacteria. The drug was assayed in guinea-pig and human plasma with a high-performance liquid chromatographic procedure using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene and ultraviolet detection. Linearity was established over the range 0.5–40 μg/ml using 50 μl of plasma. Accuracy had a mean relative error of
ISSN:0163-4356
出版商:OVID
年代:1991
数据来源: OVID
|
12. |
A Simple, Sensitive Liquid Chromatographic Assay ofcis‐Thiothixene in Plasma with Coulometric Detection |
|
Therapeutic Drug Monitoring,
Volume 13,
Issue 1,
1991,
Page 79-85
M. Hariharan,
Ted VanNoord,
Erick Kindt,
Rajiv Tandon,
Preview
|
PDF (567KB)
|
|
摘要:
A novel, simple, and very sensitive liquid-chromatographic assay with a coulometric detector has been developed for quantitatingcis-thiothixene (CTX) in human plasma. A reverse phase, 5-μm cyano column (25 x 0.46 cm), a mobile phase of phosphate buffer (pH 2.5) and acetonitrile (40/60 by vol), and a coulometric detector are used for the separation of CTX, and the internal standard, trifluoperazine. CTX and trifluoprazine are extracted from alkalinized plasma inton-pentane-isopropanol (95/5 by vol) and purified by back extraction into perchloric acid. The optimum oxidation potential for the analytes is +0.8 V versus an Ag/AgCl electrode. The detection limit for CTX is 200 pg using 1 mL of plasma and CTX concentrations are linear from 0 to 40 μg/L. The average interassay CV is 9%, and the mean recovery is 99% relative to the internal standard. Possible interferences from various psychiatric and common drugs in the assay have been studied. The assay method was validated by determining the concentration of CTX in the plasma of 100 schizophrenic patients.
ISSN:0163-4356
出版商:OVID
年代:1991
数据来源: OVID
|
13. |
FlecainideWhat Are We Measuring? |
|
Therapeutic Drug Monitoring,
Volume 13,
Issue 1,
1991,
Page 86-86
Ian Watson,
Preview
|
PDF (28KB)
|
|
ISSN:0163-4356
出版商:OVID
年代:1991
数据来源: OVID
|
14. |
Announcement |
|
Therapeutic Drug Monitoring,
Volume 13,
Issue 1,
1991,
Page 87-87
Preview
|
PDF (17KB)
|
|
ISSN:0163-4356
出版商:OVID
年代:1991
数据来源: OVID
|
|