|
1. |
Front cover |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 033-034
Preview
|
PDF (499KB)
|
|
摘要:
JASPE2 8(8j 61 N-66N 1053-1 122 337R-405R 9 9 ) Typeset by Burgess Thames View Abingdon Oxfordshire December 1993 Printed in Great Britain by Journal of Analytical Atomic Spectrometry Including Atomic Spectrometry Updates CONTENTS NEWS AND VIEWS 61 N Obituary-David A Hickman 61 N Reconstruction of Boris L'vov's Electrothermal Atomizer-Judith Egan-Shuttler 61 N Gordon Kirkbright Bursary 62N Book Review-Adam McMahon 63N Diary of Conferences and Courses 65N Future Issues PAPERS 1053 1059 1067 1075 1085 1091 1097 1103 1109 1113 1117 1121 Determination of Ultratrace Levels of Heavy Metals in Arctic Snow by Electro- thermal Vaporization Inductively Coupled Plasma Mass Spectrometry-Ralph E Sturgeon Scott N Willie James Zheng Akira Kudo D Conrad Gregoire Determination of Palladium and Platinum in Fresh Waters by Inductively Coupled Plasma Mass Spectrometry and Activated Charcoal Preconcentration-Gwendy E M Hall J C.Pelchat Determination of Selenium in Marine Certified Reference Materials by Hydride Generation Inductively Coupled Plasma Mass Spectrometry-Hiroaki Tao Joseph W H Lam James W McLaren Arsenic Speciation in Seafood Samples With Emphasis on Minor Constituents an tnvestigation Using High-performance Liquid Chromatography With Detection by Inductively Coupled Plasma Mass Spectrometry-Erik H Larsen Gunnar Pritzl Steen Honore Hansen Speciation of Arsenic by Ion Chromatography and Off -line Hydride Generation Electrothermal Atomic Absorption Spectrometry-Han Heng-bin Liu Yan-bing Mou Shi-fen Ni Zhe-mmg Electrothermal Vaporization for Sample Introduction in Microwave-induced Plasma Atomic Absorption Spectrometry-Ytxiang Duan Xingyou Li Qinhan Jin Improvement in Mercury Cold Vapour Atomic Techniques by Resorting to Organized Assemblies and On-line Membrane Drying of Vapour-B Aizpun Fernandez M R Fernandez de la Campa Alfred0 Sanz-Medel Improvement in Detection Limits in Graphite Furnace Diode Laser Atomic Absorption Spectrometry by Wavelength Modulation Technique.Plenary Lecture-Christoph Schnurer-Patschan Aleksandr Zybin Henning Groll Kay Niemax Preliminary Study on the Use of Palladium as a Chemical Modifier for the Determination of Silicon by Electrothermal Atomic Absorption Spectrometry-Zhixra Zhuang Pengyuan Yang Xiaoru Wang Zhiwei Deng Benli Huang Effect of Aqueous Organic Solvents on the Determination of Trace Elements by Flame Atomic Absorption Spectrometry and Inductively Coupled Plasma Atomic Emission Spectrometry-M Todorovic S Vidovic.Z IIIC Indirect Flame Atomic Absorption Spectrometric Determination of Papaverine Strychnine and Cocaine by Continuous Precipitation With Dragendorff's Reagent-Marceltna Eisman Mercedes Gallego Miguel Valcarcel CUMULATIVE AUTVOR INDEX ATOMIC SPECTROMETRY 337R Industrial Analysis Metals Chemicals and Advanced Materials-John Marshall UPDATE John Carroll James S. Crighton Charles L. R. Barnard 377R References continued on inside back cover 0267-9477C199318:l-YJASPE2 8(8j 61 N-66N 1053-1 122 337R-405R 9 9 ) Typeset by Burgess Thames View Abingdon Oxfordshire December 1993 Printed in Great Britain by Journal of Analytical Atomic Spectrometry Including Atomic Spectrometry Updates CONTENTS NEWS AND VIEWS 61 N Obituary-David A Hickman 61 N Reconstruction of Boris L'vov's Electrothermal Atomizer-Judith Egan-Shuttler 61 N Gordon Kirkbright Bursary 62N Book Review-Adam McMahon 63N Diary of Conferences and Courses 65N Future Issues PAPERS 1053 1059 1067 1075 1085 1091 1097 1103 1109 1113 1117 1121 Determination of Ultratrace Levels of Heavy Metals in Arctic Snow by Electro- thermal Vaporization Inductively Coupled Plasma Mass Spectrometry-Ralph E Sturgeon Scott N Willie James Zheng Akira Kudo D Conrad Gregoire Determination of Palladium and Platinum in Fresh Waters by Inductively Coupled Plasma Mass Spectrometry and Activated Charcoal Preconcentration-Gwendy E M Hall J C.Pelchat Determination of Selenium in Marine Certified Reference Materials by Hydride Generation Inductively Coupled Plasma Mass Spectrometry-Hiroaki Tao Joseph W H Lam James W McLaren Arsenic Speciation in Seafood Samples With Emphasis on Minor Constituents an tnvestigation Using High-performance Liquid Chromatography With Detection by Inductively Coupled Plasma Mass Spectrometry-Erik H Larsen Gunnar Pritzl Steen Honore Hansen Speciation of Arsenic by Ion Chromatography and Off -line Hydride Generation Electrothermal Atomic Absorption Spectrometry-Han Heng-bin Liu Yan-bing Mou Shi-fen Ni Zhe-mmg Electrothermal Vaporization for Sample Introduction in Microwave-induced Plasma Atomic Absorption Spectrometry-Ytxiang Duan Xingyou Li Qinhan Jin Improvement in Mercury Cold Vapour Atomic Techniques by Resorting to Organized Assemblies and On-line Membrane Drying of Vapour-B Aizpun Fernandez M R Fernandez de la Campa Alfred0 Sanz-Medel Improvement in Detection Limits in Graphite Furnace Diode Laser Atomic Absorption Spectrometry by Wavelength Modulation Technique.Plenary Lecture-Christoph Schnurer-Patschan Aleksandr Zybin Henning Groll Kay Niemax Preliminary Study on the Use of Palladium as a Chemical Modifier for the Determination of Silicon by Electrothermal Atomic Absorption Spectrometry-Zhixra Zhuang Pengyuan Yang Xiaoru Wang Zhiwei Deng Benli Huang Effect of Aqueous Organic Solvents on the Determination of Trace Elements by Flame Atomic Absorption Spectrometry and Inductively Coupled Plasma Atomic Emission Spectrometry-M Todorovic S Vidovic. Z IIIC Indirect Flame Atomic Absorption Spectrometric Determination of Papaverine Strychnine and Cocaine by Continuous Precipitation With Dragendorff's Reagent-Marceltna Eisman Mercedes Gallego Miguel Valcarcel CUMULATIVE AUTVOR INDEX ATOMIC SPECTROMETRY 337R Industrial Analysis Metals Chemicals and Advanced Materials-John Marshall UPDATE John Carroll James S. Crighton Charles L. R. Barnard 377R References continued on inside back cover 0267-9477C199318:l-Y
ISSN:0267-9477
DOI:10.1039/JA99308FX033
出版商:RSC
年代:1993
数据来源: RSC
|
2. |
Contents pages |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 035-036
Preview
|
PDF (142KB)
|
|
摘要:
JASPE2 8(8j 61 N-66N 1053-1 122 337R-405R 9 9 ) Typeset by Burgess Thames View Abingdon Oxfordshire December 1993 Printed in Great Britain by Journal of Analytical Atomic Spectrometry Including Atomic Spectrometry Updates CONTENTS NEWS AND VIEWS 61 N Obituary-David A Hickman 61 N Reconstruction of Boris L'vov's Electrothermal Atomizer-Judith Egan-Shuttler 61 N Gordon Kirkbright Bursary 62N Book Review-Adam McMahon 63N Diary of Conferences and Courses 65N Future Issues PAPERS 1053 1059 1067 1075 1085 1091 1097 1103 1109 1113 1117 1121 Determination of Ultratrace Levels of Heavy Metals in Arctic Snow by Electro- thermal Vaporization Inductively Coupled Plasma Mass Spectrometry-Ralph E Sturgeon Scott N Willie James Zheng Akira Kudo D Conrad Gregoire Determination of Palladium and Platinum in Fresh Waters by Inductively Coupled Plasma Mass Spectrometry and Activated Charcoal Preconcentration-Gwendy E M Hall J C.Pelchat Determination of Selenium in Marine Certified Reference Materials by Hydride Generation Inductively Coupled Plasma Mass Spectrometry-Hiroaki Tao Joseph W H Lam James W McLaren Arsenic Speciation in Seafood Samples With Emphasis on Minor Constituents an tnvestigation Using High-performance Liquid Chromatography With Detection by Inductively Coupled Plasma Mass Spectrometry-Erik H Larsen Gunnar Pritzl Steen Honore Hansen Speciation of Arsenic by Ion Chromatography and Off -line Hydride Generation Electrothermal Atomic Absorption Spectrometry-Han Heng-bin Liu Yan-bing Mou Shi-fen Ni Zhe-mmg Electrothermal Vaporization for Sample Introduction in Microwave-induced Plasma Atomic Absorption Spectrometry-Ytxiang Duan Xingyou Li Qinhan Jin Improvement in Mercury Cold Vapour Atomic Techniques by Resorting to Organized Assemblies and On-line Membrane Drying of Vapour-B Aizpun Fernandez M R Fernandez de la Campa Alfred0 Sanz-Medel Improvement in Detection Limits in Graphite Furnace Diode Laser Atomic Absorption Spectrometry by Wavelength Modulation Technique.Plenary Lecture-Christoph Schnurer-Patschan Aleksandr Zybin Henning Groll Kay Niemax Preliminary Study on the Use of Palladium as a Chemical Modifier for the Determination of Silicon by Electrothermal Atomic Absorption Spectrometry-Zhixra Zhuang Pengyuan Yang Xiaoru Wang Zhiwei Deng Benli Huang Effect of Aqueous Organic Solvents on the Determination of Trace Elements by Flame Atomic Absorption Spectrometry and Inductively Coupled Plasma Atomic Emission Spectrometry-M Todorovic S Vidovic.Z IIIC Indirect Flame Atomic Absorption Spectrometric Determination of Papaverine Strychnine and Cocaine by Continuous Precipitation With Dragendorff's Reagent-Marceltna Eisman Mercedes Gallego Miguel Valcarcel CUMULATIVE AUTVOR INDEX ATOMIC SPECTROMETRY 337R Industrial Analysis Metals Chemicals and Advanced Materials-John Marshall UPDATE John Carroll James S. Crighton Charles L. R. Barnard 377R References continued on inside back cover 0267-9477C199318:l-YJASPE2 8(8j 61 N-66N 1053-1 122 337R-405R 9 9 ) Typeset by Burgess Thames View Abingdon Oxfordshire December 1993 Printed in Great Britain by Journal of Analytical Atomic Spectrometry Including Atomic Spectrometry Updates CONTENTS NEWS AND VIEWS 61 N Obituary-David A Hickman 61 N Reconstruction of Boris L'vov's Electrothermal Atomizer-Judith Egan-Shuttler 61 N Gordon Kirkbright Bursary 62N Book Review-Adam McMahon 63N Diary of Conferences and Courses 65N Future Issues PAPERS 1053 1059 1067 1075 1085 1091 1097 1103 1109 1113 1117 1121 Determination of Ultratrace Levels of Heavy Metals in Arctic Snow by Electro- thermal Vaporization Inductively Coupled Plasma Mass Spectrometry-Ralph E Sturgeon Scott N Willie James Zheng Akira Kudo D Conrad Gregoire Determination of Palladium and Platinum in Fresh Waters by Inductively Coupled Plasma Mass Spectrometry and Activated Charcoal Preconcentration-Gwendy E M Hall J C.Pelchat Determination of Selenium in Marine Certified Reference Materials by Hydride Generation Inductively Coupled Plasma Mass Spectrometry-Hiroaki Tao Joseph W H Lam James W McLaren Arsenic Speciation in Seafood Samples With Emphasis on Minor Constituents an tnvestigation Using High-performance Liquid Chromatography With Detection by Inductively Coupled Plasma Mass Spectrometry-Erik H Larsen Gunnar Pritzl Steen Honore Hansen Speciation of Arsenic by Ion Chromatography and Off -line Hydride Generation Electrothermal Atomic Absorption Spectrometry-Han Heng-bin Liu Yan-bing Mou Shi-fen Ni Zhe-mmg Electrothermal Vaporization for Sample Introduction in Microwave-induced Plasma Atomic Absorption Spectrometry-Ytxiang Duan Xingyou Li Qinhan Jin Improvement in Mercury Cold Vapour Atomic Techniques by Resorting to Organized Assemblies and On-line Membrane Drying of Vapour-B Aizpun Fernandez M R Fernandez de la Campa Alfred0 Sanz-Medel Improvement in Detection Limits in Graphite Furnace Diode Laser Atomic Absorption Spectrometry by Wavelength Modulation Technique.Plenary Lecture-Christoph Schnurer-Patschan Aleksandr Zybin Henning Groll Kay Niemax Preliminary Study on the Use of Palladium as a Chemical Modifier for the Determination of Silicon by Electrothermal Atomic Absorption Spectrometry-Zhixra Zhuang Pengyuan Yang Xiaoru Wang Zhiwei Deng Benli Huang Effect of Aqueous Organic Solvents on the Determination of Trace Elements by Flame Atomic Absorption Spectrometry and Inductively Coupled Plasma Atomic Emission Spectrometry-M Todorovic S Vidovic. Z IIIC Indirect Flame Atomic Absorption Spectrometric Determination of Papaverine Strychnine and Cocaine by Continuous Precipitation With Dragendorff's Reagent-Marceltna Eisman Mercedes Gallego Miguel Valcarcel CUMULATIVE AUTVOR INDEX ATOMIC SPECTROMETRY 337R Industrial Analysis Metals Chemicals and Advanced Materials-John Marshall UPDATE John Carroll James S. Crighton Charles L. R. Barnard 377R References continued on inside back cover 0267-9477C199318:l-Y
ISSN:0267-9477
DOI:10.1039/JA99308BX035
出版商:RSC
年代:1993
数据来源: RSC
|
3. |
Back matter |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 051-054
Preview
|
PDF (310KB)
|
|
摘要:
Royal Society of Chemistry Analytical Division Atomic Spectroscopy Group Seventh Biennial National Atomic Spectroscopy Symposium 7th BNASS University of Hull UK 20 - 22 July 1994 Plenary Lectures tnvited Lectures Call for Papers Exhibition Professor R F Browner shmple introduction the Achilles heel of ICP-AES Dr H T Delves Clinical and environmental applications of AS Professor R S Houk Innovations in elemental analysis by MS Dr R Kloclcenhnper TXRF - Physical principles and analytical applications Dr D L Styns The elucidation of electrothermal atomizer mechanisms - and TCP-MS; Part II surface science at very high temperatures Dr H M Crews Multi-element anaIysis of biological materials by ICP-MS - The Dr W Frech AS techniques for the determination of mercury and its compounds in Professor S Greenfield The ICP as source and atodion reservoir Dr G M Greenway On-line Preconcentration for AS Dr D J Halls Analytical minimalism applied to the determination of trace elements Dr P J Potts Design considerations for a laboratory HW microprobe; optimizing the Dr I L Shuttler Recent developments in ETAAS instrumentation Dr K C Thompson The utilization of vapour generation techniques in environmental Dr C T Tye Interfacing plasma sources with mass spectrometers is it art or science? Mrs K A Wolnik Applications of ICP-ES and ICP-MS to forensic anaIysis reality! environmental samples and petroleum products in clinical and biological samples use of glass capillary collimators based on results @om a ray-tracing program analysis Contributed oral and poster presentations on recent developments in both pure and applied atomic spectroscopy - analytical applications theoretical studies or fbndamental advances in U S AES AFS inorganic MS and XRF.Three copies of abstracts must be submitted before 31 March 1994 Suppliers of atomic spectroscopic instrumentation and accessories ancillary equipment and scientific publishers Social Programme BNASS has an enviable reputation of being a fiiendly and dynamic meeting. A number of social events including a Symposium Dinner will form an integral part of the meeting Immediately prior to the 7th BNASS there will be a Workshop on Sample Pre-treatment and Sample Introduction for Atomic Spectroscopy 19 - 20 July 1994 Workshop Further Details Dr Steve Haswell School of Chemistry University of Hull Hull HU6 7RX UK.Telephone +49 (0)482 465469; fax +49 (0)482 466410The Second International Symposium on Speciation of Elements in Toxicology and in Environmental and Biological Sciences June 15-18,1994 Loen Norway. AIMS The Symposium will focus on recent speciation research related to the chemical physical and morphological states of elements as they appear irn various compartments in environmental and biological systems. The aims of the symposium are to provide a forum at which recent progress in analytical methodology of element speciation can be discussed and to provide an opportunity for an interchange of ideas between analytical and other scientists investigating fundamental aspects of environmental and human toxicology nutrition or metal containing drugs.THEMES The main themes for the Symposium are A. Sampling Characterization Detection and Determination of Chemical or Particulate Species * In Air * In Water * In Soil * In Biological Systems B.Thermodynamic and Kinetic Aspects C .Importance of Speciation in Environmental and Human Toxicology Nutrition and Medicine. * Speciation of the elements will be considered in the context of pathways to humans exposure routes uptake distribution metabolism toxicological mechanisms and excretion SUBMISSION OF ABSTRACTS All contributions (oral or poster) presented will be eligible for publication in a Special Symposium Issue of the journal The Analyst. Prospective authors should submit an abstract (A4 format) of one-page length including tables and figures by February 15 1994(deadline).ORGANIZING COMMITTEE Yngvar Thomassen (Symposium Chairman) Rita Cornelis (Gent Belgium) Brit Salbu (Am Norway) Evert Nieboer (Programme Chairman) Jytte Molin Christensen (Copenhagen Denmark) Wolfgang Frech (Umea Sweden) Jan Aaseth (Elverum Norway) FOR FURTHER INFORMATION CONTACT The Second International Symposium on Speciation of Elements in Toxicology and in Environmental and Biological Sciences Yngvar Thomassen National Institute of Occupational Health P.O. Box 8 149 DEP N-0033 Oslo 1 Norway. TEL 47 22466850; FAX 47 22603276 This Symposium has been organized by The Institute of Environment and Health (University of Toronto and McMaster University Canada) ; and The National Institute of Occupational Health (Oslo. Norway) .I The 5th Nordic Symposium on Trace Elements in Human Health and Disease June 19-21,1994 Loen Norway AIMS The Symposium will focus on recent research related to trace elements and their relevance in human physiology and toxicology.The programme will emphasize cross-disciplinary issues and promote participant interaction. The conference is intended both for scientists in academia with expertise in toxicology clinical and analytical chemistry pathology metabolic disorders occupational and environmental health and nutrition as well as environmental and health professionals. THEMES The main themes for the Symposium are * Environmental and Occupational Exposure * Analytical and Clinical Chemistry * Trace Element Imbalances Related to Human Diseases (e.g. Cancer; Cardiovascular Liver and Neurological Diseases) * Dietary Levels and Critical Requirements (Essentiality versus Toxicity; Geomedicine) * Reference Concentrations as Drugs Chemotherapeutics Diagnostic Agents and Chelation Therapy * Reproductive and Development Effects SUBMISSION OF ABSTRACTS The Organizing Committee cordially invites you to submit an abstract of original research related to the themes of the Symposium.Prospective authors should submit an abstract (A4 format) of one-page length including tables and figures by February 15 1994(deadline). All contributions (oral or poster) presented will be eligible for publication in a Special Symposium issue of The Analyst ORGANIZING COMMITTEE Jan Aaseth (Symposium Chaimn) Hedmark Central Hospital Norway Jan Alexander Institute of Public Health Oslo Norway Evert Nieboer McMaster University Hamilton Canada Jetmund Ringstad Ulleval Hospital Oslo Norway Brit Salbu Agricultural University As Norway Yngvar Thomassen (Symposium Secretary) Oslo Norway FOR FURTHER INFORMATION CONTACT Trace Elements in Human Health and Disease Yngvar Thomassen National Institute of Occupational Health P.O.Box 8149 DEP N-0033 Oslo Norway. "EL 47 22466850; FAX 47 22603276JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY READER ENQUIRY SERVICE DECEMBER '93 For further information about any of the products featured in the advertisements in this issue please write the appropriate number in one of the boxes below. Postage paid if posted in the British Isles but overseas readers must affix a stamp.t x Valid 12 months PLEASE USE BLOCK CAPITALS LEAVING A SPACE BETWEEN WORDS I I T T - I I - 1 - l I 1 Tl-711 1 1 I i I 1 I I I I I 1 1 I T I 1 ; I I l;l I I I I I i I I I i Ii! i 1 nn 1 I I i I I I 1 - u i U L . u 1 L 1 - J - 1 I I 1 1 i l l _ - ~ I i I I i 1 n l l l [ 1 I I I [ 1 I I TT1 - T 1 NAME _ _ _- - - I 2 COMPANV PLEASE GIVE YOUR BUSINESS AOORESS IF POSSIBLE. IF NOT PLEASE TICK HERE fl 3 STREET 4 TOWN 1 5 COUNTY POST CODE 6 COUNTRY 7 DEPARTMENT DIVISION 8 VOUR JOB TITLE POSITION 9 TELEPHONE NO - l l l l l l l l l l l OFFICE USE ONLV I 4 t C U PRO(' I) FOLD HERE I j I I I I I I I I I I I I I I t I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I Postage wilt be paid by Licensee Do not affix Postage Stamps if posted in GI:. Britain Channel Islands N. Ireland or the Isle of Man 1 BUSINESS REPLY SERVICE Reader Enquiry Service Journal of Analytical Atomic Spectrometry The Royal Society of Chemistry Burlington House Piccadilly LONDON W1E 6WF England I 1 I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I 21 I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I 1 I I I 1 I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I 1 I I I I I I
ISSN:0267-9477
DOI:10.1039/JA99308BP051
出版商:RSC
年代:1993
数据来源: RSC
|
4. |
Gordon F. Kirkbright Bursary Fund 1994 |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 61-62
Preview
|
PDF (66KB)
|
|
摘要:
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 61N Gordon F. Kirkbright Bursary Fund 1994 The fund was established in 1985 as a the Committee of the Association of first post-doctoral position) to visit a memorial to Gordon Kirkbright and British Spectroscopists and the ABS recognized scientific meeting or place his contributions to analytical spec- Trust; it aims to enable promising or learning. troscopy and to analytical science in young scientists of any nation (e.g. In 1993 bursaries were awarded general. The fund is administered by postgraduate students or those in their to Jonathan D. Howe Christopher62N JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 D. Puxley and Alice E. Thornley. Jonathan Howe is working at Bristol for a PhD on resonance enhanced multiphoton ionization spectroscopy to detect gaseous free radicals.He visited the National Institute of Stan- dards and Technology in the USA for 5 weeks and presented a paper at the Ohio State Symposium on Molecular Spectroscopy. Christopher Puxley is a PhD student in the Fluorine Group at Leicester he attended the Ninth meeting on Chemistry and Physics of Matrix-isolated Species in Hel- sinki Finland. Alice Thornley is a PhD student at the University of Durham she is a theoretical chemist calculating the spectra of Van der Waals molecules and visited the laboratory of Professor Roger Miller at the University of North Carolina USA. Applications are now invited for the award of the Gordon F. Kirkbright bursaries for 1994. Completed forms must be received not later than Febru- ary 28 1994. Full details and applica- tion forms can be obtained from Professor L.H. Sutcliffe Department of Chemistry University of Surrey Guildford Surrey UK GU2 SXH. Telephone 0483 300 800 ext. 9586; Fax 0483 300 803.
ISSN:0267-9477
DOI:10.1039/JA99308061Nc
出版商:RSC
年代:1993
数据来源: RSC
|
5. |
Book review |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 62-62
Adam McMahon,
Preview
|
PDF (152KB)
|
|
摘要:
62N JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Book Review Applied Laser Spectroscopy Techniques Instrumentation and Applications Edited by David L. Andrews. Pp ix +47 1. VCH Publishers. 1992. Price E8 1 .OO DM 198.00. ISBN 1-5608 1- 023-8. ISBN 3-527 2 8072-3 ~~ ~ This book serves as an excellent intro- duction to the major areas of applica- tion of laser spectroscopy. It is aimed at the advanced pre-graduate or gradu- ate level and provides an overview of the techniques instrumentation and many specific applications of laser spectroscopy. Whilst there is coverage of atomic laser spectroscopy most of the material describes techniques and applications of molecular spectros- copy. Nonetheless all of the material is likely to be of interest to any species of spectroscopist.The book opens with chapters by Andrews and McCoustra outlining the fundamental principles and the instru- mentation used in laser spectroscopy. The properties of laser radiation and the variety of lasers and accessory equipment available to the spectros- copist are introduced. This provides the reader with some knowledge of the tools of the trade which are applied in a variety of ways in the subsequent eight chapters. Each of these subse- quent chapters written by a well- selected author focuses on distinct subject areas within laser spectros- copy. An introduction is provided to the theory applications and current status of each technique and the reader is referred to the literature for more detailed coverage of the various topics. The chapters which directly address atomic laser spectroscopy include chapter 3 by Demtroder who dis- cusses the principles of the various types of electronic photo-absorption spectroscopy.Most examples cited however relate to molecular spectro- scopy including the measurement of atmospheric NO SO and 03. The chapter by Pfab addresses the theory of laser-induced atomic fluorescence and gives brief examples of the power of this technique in trace analysis. The main focus is again molecular spec- troscopy including a discussion of applications of the technique to flame and plasma diagnostics and the mea- surement of trace atmospheric species. In Chapter 8 Goodman and Philis discuss multiphoton absorption spec- troscopy. The theory of multiphoton absorption is outlined with particular emphasis on the selection rules which can allow the study of states not readily accessible in single photon experiments.The chapter also includes a discussion of photo-acoustic and thermal lensing detection methods. Chapter 9 by Ledingham and Singhal covers laser ionization mass spectro- metry (LIMS) and both the non-reso- nant and resonant photo-ionization of gas-phase neutrals. These post-ioniza- tion methods are amongst the most sensitive and selective methods for trace atomic and molecular measure- ments. Resonance ionization schemes are presented which are applicable to all elements except Ne and He and the authors give examples of applications to single particle metals and semicon- ductor analysis as well as to the ioniza- tion of a variety of organic molecules. The remaining chapters address techniques for molecular spectro- scopy.Howard and Brown discuss high-resolution infrared spectroscopy placing the laser-based approach in context relative to other methods such as FTIR. Applications cited include the study of diatomic and small poly- atomic neutrals and ions as well as van der Waals complexes. Comple- mentary to the chapter on infrared spectroscopy are the following two chapters by Morris and by Berger Lavorel and Millot which cover Raman spectroscopy. The various types of Raman spectroscopy are outlined with examples of important applications such as Raman micro- scopy and temperature measurement by coherent anti-Stokes Raman spec- troscopy (CARS). In the final chapter laser-based methods for the investigation of ultra- fast molecular phenomena are dis- cussed.Fluorescence Raman and in- frared spectroscopies are described which take advantage of the short timescale of laser pulses to investigate highly transient phenomena. This chapter makes fascinating reading but is further than any from the subject of analytical atomic spectroscopy. As with most experimental science laser spectroscopy has its own acro- nym soup. The appendix provides a necessary interpretation for the newcomer. There is inevitably some small de- gree of overlap between chapters and without digging deeply into all of them readers may miss aspects of theory or instrumentation not covered in the introductory chapters yet relevant to more than one subject area. Examples would be the use of optical fibre probes; photo-acoustic detection; ap- proaches to the attainment of sub- Doppler spectral resolution; and the laser magnetic resonance technique. In conclusion only a minor part of the book is directly relevant to the atomic spectroscopist but the rest of the text provides an interesting overview of state-of-the-art methods. I have en- joyed reading this book and found it to be a clearly written introduction to applied laser spectroscopy. Adam McMahon Department of Chemistry Manchester Metropolitan University Manchester MI 5GD
ISSN:0267-9477
DOI:10.1039/JA993080062N
出版商:RSC
年代:1993
数据来源: RSC
|
6. |
Diary of conferences and courses |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 63-65
Preview
|
PDF (311KB)
|
|
摘要:
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 63N Diary of Conferences and Courses 1994 WCFIA 94 1994 Winter Conference on Flow Injection Analysis January 5-7 1994 San Diego CA USA Details can be found in J. Anal. At. Spectrom. 1993 8 47N. For further information contact WCFIA 94 Gary Christian Depart- ment of Chemistry BG- 10 University of Washington Seattle WA 98195. Telephone (206) 543-1635; fax (206) 685-3478; e-mail christia@ chem.- washington.edu. 1994 Winter Conference on Plasma Spectrochemistry January 10-15,1994 San Diego CA USA Details can be found in J. Anal. At. Spectrom. 1992 7 49N. For further information contact Dr R. M. Barnes 1994 Winter Conference on Plasma Spectrochemistry c/o ICP Information Newsletter Department of Chemistry GRC Towers Univer- sity of Massachusetts Amherst MA 01003-0035 USA.Telephone 413 545 2294; fax 413 545 4490. Sanibel Conference on Mass Spectro- metry in Polymer and Material Science January 22-25 1994 Sanibel Island FL USA For further information contact Judith A. Sjoberg ASMS 815 Don Gaspar Santa Fe NM 87501 USA. Telephone (505) 989-45 17; fax (505) 989-1073. 45th Pittsburgh Conference and Expo- sition on Analytical Chemistry and Applied Spectroscopy February 28-March 4 Chicago IL USA For further information contact Pittsburgh Conference 300 Penn Center Boulevard Suite 332 Pitts- burgh PA 15235-9962 USA. ANATECH 94 4th International Sym- posium on Analytical Techniques for Industrial Process Control April 10-13 1994 Royal Hotel Casino Mandelieu La Napoule France Details can be found in J.Anal. At. Spectrom. 1993 8 48N. For further information contact ANATECH 94 Secretariat Elsevier Advanced Technology Mayfield House 256 Banbury Road Oxford UK OX2 7DH. Telephone +44 (0) 865 512242; fax +44 (0) 865 310981. 24th Annual Symposium on Environ- mental Analytical Chemistry May 16-19,1994 Ottawa Canada For further information contact M. Malaiyandi CAEC Chemistry De- partment Carleton University 1255 Colonel By Drive Ottawa Ontario Canada. International Symposium on Micro- chemical Techniques (ISM '94) May 16-20 Montreux Switzerland The International Symposium on Microchemical Techniques (ISM '94) will have its next meeting in a joint organization with the Deauville Con- ference 1994-Symposium on Analyt- ical Sciences (SAS '94) in Montreux Switzerland from May 16-20 1994.For further information contact Nicko & C.R.I. Associes 7 Rue d'Argout F-75002 Paris France. Telephone +33-1-42 334766; fax +33-1-40 41 92 41. ASMS Short Courses on Mass Spec- trometry May 22-29,1994 Hyatt Regency Hotel Chicago IL USA Introduction to Interpretation of Mass Spectra Advanced Interpretation of Mass Spectra LC-MS The Art and the Practice GC-MS for Environmental Analysis Practical MS-MS Analysis 42nd ASMS Conference on Mass Spectrometry and Allied Topics May 29-June 3 1994 Hyatt Regency Hotel Chicago IL USA For further information contact Judith A. Sjoberg ASMS 815 Don Gaspar Santa Fe NM 87501 USA. Telephone (505) 989-45 17; fax (505) 989-1073. Scandinavian Symposium on Infrared and Raman Spectroscopy SSIR-94 May30-June 1,1994 Depart men t of Chemistry University of Bergen N-5007 Bergen Norway Details can be found in J.Anal. At. Spectrom. 1993 8 48N. For further information contact Dr. Alfred A. Christy Department of Chemistry University of Bergen. Tele- phone +47 5-213363 (after 09.09.93) +47-55-213363); fax +47-5-329058 (after 09.09.93) +47-55-329058). Laila Kyrkjebo Department of Chemistry University of Bergen telephone + 47-5-2 13342 (after 09.09.93 +47-55-2 13342). Biosensors '94 The Third World Con- gress on Biosensors June 1-3 New Orleans LA USA Details can be found in J. Anal. At. Spectrom. 1993 8 42N. For further information contact Kay Russell Conference Department Elsevier Advanced Technology May- field House 256 Banbury Road Oxford UK OX2 7DH. Telephone +44 (0) 865 512242; fax +44 (0) 865 3 1098 1.6th International Conference on Flow Analysis June 8-11 Toledo Spain Details can be found in J. Anal. At. Spectrom. 1993 8 42N. For further information contact M. Valcarcel/M. D. Luque de Castro Flow Analysis VI Departamento de Quimica Analitica Facultad de Cien- cias E- 14004 Cordoba Spain. Tele- phone 34 57 218616; fax 34 57 2 18606. 7th International Symposium on Reso- nance Ionization Spectroscopy and Its Applications (RIS-94) July 3-8 199464N JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Bern kastel- Kues Germany Details can be found in J. Anal. At. Spectrom. 1993 8 59N. For further information contact RIS-94 R. Chitty Institut fur Physik Universitat Mainz Postfach 39 80 D-55092 Mainz Germany telephone 0049-6131-393628; fax 0049-6131- 393428; telex 418-7155 phmz d; email RIS94@VIPMZA.PHYSIK.UNI-MAINZ. DE. Spectroscopy Across the Spectrum IV Techniques and Applications of Analyt- ical Spectroscopy University of East Anglia Norwich UK Details can be found in J. Anal. At. Spectrom. 1993 8 59N. For further information contact Dr. D. L. Andrews School of Chemical Sciences University of East Anglia Norwich UK NR4 7TJ. Fax 0603 25936. July 11-14,1994 Seventh Biennial National Atomic Spectroscopy Symposium July 20-22 1994 University of Hull Hull UK Details can be found in J. Anal. At. Spectrom. 1992 7 49N. For further information contact Dr Steve Hill Department of Environ- mental Sciences University of Plymouth Drake Circus Plymouth Devon UK PL4 8AA. 13th International Mass Spectrometry Conference August 29-September 2 Budapest Hungary For further information contact Hun- garian Chemical Society; FO u.68 H- 1027 Budapest Hungary. Telephone 361 201 6883; fax 316 15 61215. EUCMOS XXII XXII European Con- gress on Molecular Spectroscopy September 11-16 1994 Essen Germany Details can be found in J. Anal. At. Spectrom. 1993 8 49N. For further details contact Gesell- schaft Deutscher Chemiker Abt. Tagungen P.O. Box 90 04 40 W-6000 Frankfurt 90 Germany. Telephone +49 697917-366; fax +49 69 7917- 475; telex 4 170 497 gdch d. Geoanalysis 94 An International Sym- posium on the Analysis of Geological and Environmental Materials September 18-22 1994 Charlotte Mason Conference Centre Ambleside UK. Details can be found in J.Anal. At. Spectrom. 1993 8 49N. For further information contact Mr. D. L. Miles Analytical Geochemistry Group British Geological Survey Kingsley Dunham Centre Keyworth UK NG12 5GG. Telephone 0602 363100; fax 0602 363200. 7th International Symposium on Envi- ronmental Radiochemical Analysis September 2 1-23 Bournemouth UK Dates to Note Synopses of papers January 28 1994. Final date for registration July 15 1994. For further details contact Dr P. Warwick Department of Chemistry Loughborough University of Tech- nology Loughborough Leicestershire UK LEll 3TU. Telephone 0509 222585 or 0509 222545; fax 0509 233 163. 6th International Colloquium on Solid Sampling With Atomic Spectroscopy October 11-13 1994 A msterda m The Netherlands Details can be found in J. Anal. At.Spectrom. 1993 8 59N. For further information contact Dr. R. F. M. Herber Coronel Laboratory University of Amsterdam Meiberg- dreef 15 NL-1105 AZ Amsterdam The Netherlands. Third Rio Symposium on Atomic Spec- trometry November 6-12,1994 Venezuela In keeping with the style of the Second Rio Symposium the third meeting will be divided into two parts. The first part will include work on electrothermal flame and hydride atomic absorption along with atomic emission and atomic fluorescence spectrometry. The second part will consist of two parallel sessions one devoted to electrother- mal atomic absorption spectrometry and the other to inductively coupled plasma atomic emission spectrometry. Part I will be held at Universidad Simon Bolivar in Caracas and Part I1 will take place at the Margarita Hilton Hotel on the Venezuelan Island of Margar it a.Scope Part 1 November 6-9 The programme will include invited lectures (40 min) oral presentation of papers (20 min) and posters covering the following topics introduction of samples; instrumentation develop- ments; hydride techniques; analytical quality assurance; interference studies; application to environmental biologi- cal and industrial samples; speciation; sample treatment; solid and slurry sampling; and preconcentration. Additionally a course on the appli- cation of atomic spectroscopic tech- niques to environmental problems is scheduled for this part of the meeting. Posters will be given the same prom- inence as oral presentations. Part 2 November 10- 12 (a) Workshop on Electrothermal Atomic Absorption Spectrometry (b)Workshop on ICP Atomic Emis- sion Spectrometry The programme will include invited lectures (40 min) and oral presentation of papers (20 min) covering special topics related to both techniques of analysis.More details will be given in the Second Circular. Call for Papers The organizers invite you to submit an abstract of no more than two pages. The deadline for receipt of abstracts is June 15 1994. Registration Fee The registration fee is US$ 100.00 for Part 1 and US$ 100.00 for Part 2. For registered students and accompanying persons the fee is US$50.00 for each Part. Late registration will cost 20% more. Details will be given in the Second Circular. Exhibition Instruments books and materials will be on display during Part 1 of the Symposium.Exhibitors will have the opportunity to give short explanatory talks about their equipment. Inter- ested exhibitors should contact the local organizers as soon as possible. For further information contact Pro- fessor Jose Alvarado Universidad Simon Bolivar Departamento de Quimica Laboratorio de Absorcion Atomica Apartado postal No. 89000 Caracas 1080-A Venezuela. Fax 962 1695. (0058-2-)938322 / 57 19 134 / 5763355 /JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 65N Analytica '94-Second National Sym- posium on Analytical Science December 1994 Western Cape South Africa Details can be found in J. Anal. At. Spectrom. 1993 8 60N. For further information contact Dr. I. M. Moodie c/o PO Box 1970 Tygerberg 7505 South Africa. Fax 02 1-932-4575. 1995 nestr.3 D-04 103 Leipzig Germany. Telephone and fax (49)-341-6858377. search. DeDartment of Analvtical Colloquium Spectroscopicurn Inkrna- UFZ-Centre for Environmental Re- tionale (CSI) XXIX August 27-September 1 1995 Chemistry Permoserstr. 15. D-043 18 Leipzig Germany Details can be found in J. Anal. At. Leipzig Germany. Telephone (49)- 341-235-2370; fax -2625. Spectrorn. 1993 8 50N. For further details contact Prof. Dr. K. Dittrich Universitat Leipzig FB Chemie FG Atomspektroskopie Lin-
ISSN:0267-9477
DOI:10.1039/JA993080063N
出版商:RSC
年代:1993
数据来源: RSC
|
7. |
Future issues |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 65-66
Preview
|
PDF (933KB)
|
|
摘要:
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 65N Future Issues will include- Spectral Line Selection for Determina- tion of Zirconium Cerium Thorium and Titanium by Inductively Coupled Plasma Atomic Emission Spectrome- try in Zirconia-based Ceramic Materi- als-Sergio R. Marin Silvia G. Cor- nejo Lorna Arriagada Determination of Arsenic Species in Fish by Directly Coupled High- performance Liquid Chromatogra- phy-Inductively Coupled Plasma Mass Spectrometry-Simon Branch Les Ebdon Peter O’Neill Use of Inductively Coupled Plasma Mass Spectrometry for the Determina- tion of Ultra-trace Elements in Human Serum-Hans Vanhoe Jacques Ver- sieck Richard Dams Thermal Stabilization of Antimony in Electrothermal Atomic Absorption Spectrometry-Kari Dahl Ivar Mar- tinsen Bernard Radziuk Brit Salbu Yngvar Thomassen Silicon Measurement in Bone and Other Tissues by Electrothermal Atomic Absorption Spectrometry- Zhuoer Huang High-performance Flow Electrother- mal Atomic Absorption Spectrometry for On-line Trace Element Preconcen- tration-Matrix Separation and Trace Element Determination Applied to an Aluminium Solution-Harald Berndt G.Schaldach Comparison Between Infrared and Ultraviolet Laser Ablation at Atmo- spheric Pressure-Implications for Solid Sampling Inductively Coupled Plasma Spectrometry-C. Geertsen A. Briand F. Chartier J.-L. Lacour Patrick Mauchien Jean-Michel Mer- met Sten Sjostrom Matrix Effects of Potassium Chloride and Phosphoric Acid in Argon Induc- tively Coupled Plasma Atomic Emis- sion Spectrometry-Bojan Budic Vida Hudnik Development of a Simple Method for the Determination of Toluene Extrac- table Organotin by Electrothermal Atomic Absorption Spectrometry and its Application to Effluent Analysis- K.Clive Thompson Shayessteh Dad- farnia Gavin Hoult Analysis of Electrical Arc Furnace Flue Dusts by Atomic Emission Spec- trometry-Aurora G. Coedo M. T. Dorado Isabel G. Cob0 Electrothermal Atomic Absorption Spectrometry in Occupational and En- vironmental Health Practice-a Dec- ade of Progress and Establishment. A Review-D. L. Tsalev Determination of Cadmium and Zinc Isotope Ratios in Sheep’s Blood and Organ Tissue by Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry-D. Con- rad Gregoire Julian Lee Matrix Separation by Chelation to Prepare Biological Materials for Isoto- pic Zinc Analysis by Inductively Coupled Plasma Mass Spectrome- try-Steven F.Durrant Antoaneta Krushevska Dulasiri Amarasiriwar- dena Mark D. Argentine Sabine Ro- mon-Guesnier Ramon M. Barnes Effects of Low Acetic Acid Concentra- tions in Inductively Coupled Plasma Atomic Emission Spectrometry- Sanda Roncevic Marija Siroki Determination of Chromium in Bio- logical Fluids by Electrothermal Atomic Absorption Spectrometry Us- ing Wall Platform and Probe Atomi- zation From Different Graphite Surfa- ces-E. Alvarez-Cabal Cimadevilla Katarzyna Wrobel J. Gayon Mar- chante A. Sanz-Medel Isotope Dilution Glow Discharge Mass Spectrometry as Applied to the Analysis of Lead in Waste Oils -Christopher M. Barshick David H. Smith Jeffrey W. Wade Charles K.BayneRamon M. Barnes Editor Department of Chemistry LGRC Towers University of Massachusetts Am herst MA 01 003-0035 Telephone (413) 545-2294 fax 545-4490 Objective The ICP INFORMATION NEWSLETTER is a monthly journal published by the Plasma Research Group at the University of Massachusetts and is devoted exclusively to the rapid and impartial dissemination of news and literature information re- lated to the development and applications of plasma sources for spectrochemical analysis. Background ICP stands for inductively coupled plasma discharge which duringthe past decade has become the leading spectrochemi- cal excitation source for atomic emission spectroscopy. ICP discharges also are applied commercially as an ion source for mass spectrometry and as an atom and ion cell in atomic fluo- rescence spectrometry.The popularity of this source and the need to collect in a single literature reference all of the pertinent data on ICP stimulated the publication of the ICP INFOR- MATION NEWSLETTER in 1975. Other popular plasma sources i.e. microwave induced plasmas direct current plasmas and glow discharges atso are included in the scope of the ICP IN- FORMATION NEWSLETTER. Scope As the only authoritative monthly journal of its type the ICP INFORMATlON NEWSLETTER is read in more than 40 coun- tries by scientists actively applying or planning to use the ICP or other types of plasma spectroscopy. For the novice in the field the ICP 1NK)RMATlON NEWSLETTER provides a conase and systematic source of information and background material needed for the selection of instrumentation or the development of methodology.For the experienced scientist it offers a sin- gle-source reference to current developments and literature. Editorial The ICP INFORMATION NEWSLETTER is edited by Dr. Ramon M. Barnes Professor of Chemistry University of Mas- sachusetts at Amherst with the assistance of a 20-member Board of National Correspondents composed of leading plasma spectroscopists. The Board members from around the world report news viewpoints and developments. Dr. Barnes has been conducting plasma research on ICP and other dis- charges since 1968. He also serves as chairman of the Winter Conference on Plasma Spectrochemistry sponsored by the ICP INFORMATION NEWSLETTER. Regular Features .Original submitted and invited research articles by ICP and .Complete bibliography of all major ICP publications..Abstracts of all ICP papers presented at major US and inter- .First-hand accounts of world-wide ICP developments. .Special reports on dcp microwave glow discharge and other Calendar and advanced programs of plasma meetings. .Technical translations and reprints of critical foreign-lan- guage ICP papers. Critical reviews of plasma-related books and software. Conference Activities The ICP INFORMATION NEWSLETTER has sponsored seven international meetings on developments in atomic plasma spectrochemical analysis since 1980 in San Juan Orlando San Diego St. Petersburg and Kailua-Kona. Meeting pro- ceedings have appeared as Developments in Atomic Plasma Specfrochemical Analysis (Wiley) Plasma Spectrochemistry and Plasma Spectrochemistry 11-IV (Pergamon Press) as well as in special issues of Specfrochimica Acta Part B and Journal of Analytical Atomic Spectrometry.The 1994 Winter Confer- ence on Plasma Spectrochemistry will be held in San Diego California January 10 - 15 1994; its proceedings will be published by Fall 1994. Subscription Information Subscriptions are available for 12 issues on either an annual or volume basis. The first issue of each volume begins in June and the last issue is published in May. For example Volume 18 runsfrom June 1992 through May 1993. Back issues beginning with Volume 1 May 1975 also are available. To begin a subscription complete the form below and submit it with prepayment or purchase information.For additional informa- tion please call (41 3) 545-2294 fax (41 3) 545-4490 or contact the Editor. Credit cards accepted. plasma experts. national meetings. plasma progress. To order complete this section and send it to ICP Information Newsletter %Dr. Ramon M. Barnes Depart- ment of Chemistry Lederle GRC Towers University of Massachusetts Amherst MA 01 003-0035 USA. Start a subscription for the following issue 0 Volume(s)- (June 19- - May 19- ) or CI 19 (January - December). Enclosed 0 Prepayment 0 Check or money order QVISA c1 Mastercard Account No. (All 13 or 16 digits) ) or 0 Send invoice. Date Card holder Signature .Amount Due $ - Mail to Name Organization Address City State/Country ZI P/Postalcode Telephone - Telex/fax Note For each credit-card transaction a 4 % service charge will be added reflecting our bank charges. Current subscription rates are $60 (North America) $85 (Europe South America) or $94 (Africa Asia Indian/Pacific Ocean Areas Middle East and Russia). Back issue rates available on request. All payments should be made with US dollars by draft on a US bank by international money order or by credit card. Foreign bank checks are not accepted. 0 Purchase order (No. Cardholder Name Expiration date - -__
ISSN:0267-9477
DOI:10.1039/JA993080065N
出版商:RSC
年代:1993
数据来源: RSC
|
8. |
Atomic Spectrometry Update—Industrial Analysis: Metals, Chemicals and Advanced Materials |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 337-375
John Marshall,
Preview
|
PDF (5128KB)
|
|
摘要:
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 33713 ATOMIC SPECTROMETRY UPDATE-INDUSTRIAL ANALYSIS METALS CHEMICALS AND ADVANCED MATERIALS John Marshall* and John Carroll ICI plc Wilton Research Centre P.O. Box 90 Middlesbrough Cleveland UK TS6 W E . James S. Crighton BP Research and Engineering Centre Chertsey Road Sunbury on Thames Middlesex UK TWI 6 7LN Charles L. R. Barnard Department of Physical Sciences Glasgow Caledonian University Cowcaddens Road Glasgow UK G4 OBA Summary of Contents 1. Metals 1.1. Ferrous Metals and Alloys 1.2. Non-Ferrous Metals and Alloys Table 1. Summary of Analyses of Metals 2. Chemicals 2.1. Petroleum and Petroleum Products 2.1 .l. Crude oil and fractions 2.1.2. Lubricating oils 2.2. Organic Chemicals and Solvents 2.2.1. Chemicals 2.2.2.Solvents 2.2.3. Catalysts 2.3. Inorganic Chemicals and Acids 2.4. Nuclear Materials 2.5. Process Analysis and Automation Table 2. Summary of the Analyses of Chemicals 3. Advanced Materials 3.1. Polymeric Materials and Composites 3.2. Semiconductor Materials 3.2.1 Silicon based materials 3.2.2. Gallium arsenide based materials 3.2.3. Cadmium mercury telluride and indium phosphide based materials 3.3. Glasses Ceramics and Refractories 3.3.1 Glasses 3.3.2 Ceramics and refractories Table 3. Summary of Analyses of Advanced Materials This Atomic Spectrometry Update is the latest in an annual series appearing under the title of ‘Industrial Analysis’. The structure of the review is broadly the same as in previous years. Reports on the analysis of catalysts have been moved from the ceramics and refractories section into the chemicals section of the review.It is hoped that this categorization will better reflect the interest in these materials in the petrochemicals industry. The year in which major developments in instrumental analytical chemistry begin can usually only be identified with the benefit of hindsight. It has been evident for some time that where sensitivity and selectivity are required mass spectrometric techniques have begun to dominate the field of atomic spectrometry. Pressures on industry to improve productivity have favoured rapid multi-element techniques such as ICP-MS and the advent of a viable solid sampling option in LA has provided a very powerful tool for product and process investigation.The identification of chemical form continues to grow in importance and the use of atomic spectrometry coupled with chromatography has become a significant area of research in the chemicals industry. Surface analysis techniques based on MS (e.g. SIMS GDMS) still make an enormous contribution to the characterization of semiconductors. However TXRF is now making a significant impact in this field as a consequence of the high sensitivity of the technique and its applicability to the non-destructive analysis of wafers and thin films. The advent of r.f. boosted GDs represents a promising development but it remains to be seen whether practical advantages over more conventional techniques such as WDXRF can be demonstrated in an industrial context. *Review Co-ordinator to whom correspondence should be addressed.338R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 1. METALS This section of the review covers the analysis offerrous and non- ferrous metals and alloys by analytical atomic spectro- metry. A summary of the methods for the analysis of metals is given in Table 1. The composition of the abstracts received for review was approximately one third for ferrous metals and the remainder for non-ferrous. 1.1. Ferrous Metals and Alloys The vast majority of the publications received described modifications to sample preparation methods. There is considerable emphasis on the presentation of the sample in a form that presents the best opportunity for near interfer- ence-free determination. As might be expected this is particularly the case for AAS and ICP-AES.The use of interference inhibitors in AAS has received further attention for the determination of Cr and Mn in steel. It was observed that guanidine and formamide and also ethylenedamine and ethanolamine proved to be effective inhibitors for the interference of transition metals in the determination of Cr and Mo in steel (93/1114 93/11 15). In a similar vein the same group reported that hexamine urea and glycine were effective in eliminating inter-element effects in the determi- nation of Mo in steel (93/2670). An automatic sample treatment system for introduction of hydride forming and non-hydride forming elements has been described which uses on-line acidification and hydride generation (93/C3067). This approach allowed both types of elements to be introduced into the ICP via a nebulizer.The use of combined methods including ion chromato- graphy and various forms of microcolumn preconcentration continue to be reported as these approaches offer the benefits of matrix separation and signal enhancement. The determination of Co in steel has been carried out successfully using such a method (93/2726). Cobalt was preconcentrated on an ammonium tetraphenyl borate ion-pair column supported on naphthalene using 2-( 5 bromopryridazol-5- diethylamino phenol) chelation and was then eluted with DMF. The linear range was reported to be 1 - 10 pg of Co in 5 ml of eluate and typical precision for the method was of the order of 1 Yo relative. A chromatographic separation was employed for the determination of S in high-purity iron by ICP-AES (93/ 10 12).Sulfate was separated from the matrix elements on alumina microcolumns and S was determined at 180.73 nm with a detection limit of 0.3 ppm. A method has been reported for the determination of B in high-purity iron (92/44 17). The sample was dissolved in hydrofluoric acid and hydrogen peroxide and the residue fused with sodium and passed through an anion-exchange chromatography column. The adsorbed B was eluted with 2 mol dm-3 nitric acid and then evaporated to further preconcentrate the sample prior to analysis. Sequential ICP-AES instruments take a finite time to move between analyte wavelengths and this can be inconvenient when monitoring transient chroma- tographic peaks. This problem was overcome for the application of ion chromatography to nitric acid digests of iron and steel samples by adjusting the elution flow rate to match the ICP-AES spectrometer scanning rate (93/434).The search for more rapid methods of analysis for use in the quality control of steel production continues. The time taken for sampling and conveying samples to the laboratory is now becoming a significant proportion of the overall analysis time. It is possible to determine elements in steel by sampling dust particles above the molten metal (93/783). A sub-10 pm particulate fraction was separated from the bulk dust above molten steel with a cyclone system immediately prior to direct introduction into a flame atomic absorption spectrometer. The Mn content of this fraction was found to correlate well with the bulk Mn content of the steel.There has been particular interest shown in the period under review in the application of spark-based techniques for the direct analysis of solid steel samples. The relative merits of spark ablation ICP-MS and GDMS for the characterization of 20 elements in an NIST steel sample have been compared (93K1330). It was reported that GDMS was preferred on the basis of superior sensitivity. I-fowever in another study of the analysis of steels spark ablation ICP-MS was compared with GDMS using a similar IviS detector in both systems (92/4605). It was reported in this case that the relative sensitivity for elements and precision (approximately 3% relative) for the spark ablation system were similar to those obtained with the GDMS instrument.In addition spark ablation ICP-MS exhibited relatively few spectral interferences from polyatomic spe- cies presumably as a result of more efficient atomization. The determination of V in ferrovanadium by spark ablation ICP-AES has also been reported (92/4627). Samples were re-melted and diluted with iron to avoid fracturing prob- lems and it was reported that under these conditions spark ablation at a high repetition rate yielded a precision for V of 0.3% relative. In another application of spark ablation ICP- AES the analysis of steels was investigated (93/1254). It was noted that the spark discharge generated ultra-fine dust particles and by careful control of plasma parameters results could be obtained which were in good agreement with conventional methods.The analysis cycle time was reduced to 90 s using this approach. Laser ablation is now receiving significant attention as a means of introducing solid steel samples for ICP-MS. A comparison of laser and spark ablation procedures has been rnade (93K1325). It was observed that the laser-based procedure offered a larger linear dynamic range because of the ability to ablate a smaller amount of sample than the spark device. The use of the laser in Q-switched mode was found to prevent the spread of sample from the ablation crater. Laser ablation ICP-MS can also be used for depth profiling of solid steel samples (93/23 10). An investigation was made of the effect of laser power pulse repetition rate and optical focusing parameters on the resolution of depth profiles obtained using the technique.It was observed that the best resolution was achieved when the laser was cle-focussed by 10 mm. It was found that ablation rates differed for low and high boiling-point elements. Laser ablation ICP-MS has been applied to the determination of a range of elements in steels (93/2402). A Q-switched Nd:YAG laser was employed for this work and it was found that this device generated particles of the order of 0.02 pm in diameter. It was noted that selective vaporization of 1 olatiles was possible but at a relatively low sensitivity. IJsing an integration time of 0.18 s detection limits were in the range 0.01 ppm (Nd) to 5.5 ppm (Ni). Laser sampling can also be used in AES by direct observation of character- istic radiation emitted from the plasma plume generated by iinteraction between the beam and the sample (93/3 153).In tlhis study time-resolved spectra obtained in a nitrogen atmosphere were acquired for the determination of C in steel. Analytical precision for the determination was 1.6% relative and an LOD of 65 ppm was reported. Glow discharge sources are increasingly being used for the direct analysis of steels. The effect of GD anode geometry on sampling for AES has been the subject of investigation (93/1019). It was found that the electric field distribution was influenced by anode geometry and that the flatness of the crater bottom was related to the diameter of the anode. Operation under optimized conditions with a ceramic slpacer was reported to yield a flat crater profile. The system was applied to the determination of Mn in steel.In an interesting application of GD-AES a neural network wasJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 339R Element Matrix Ag Super alloy Ag High-purity copper Table 1 SUMMARY OF THE ANALYSES OF METALS Technique; atomization; analyte form* AE;ICP;L AA;F;L Al Iron and Steel Al Steel Al Aluminium targets As Nickel-based alloy As Nickel As Nickel Alloy Au Gold silver copper alloys B High-purity iron B Steel slag B Steel B Steels Bi Iron and Steel C Steel C Steel AA;ETA;L MS;LA;S X-ray emission; -;S AA;F;G AA;ETA;L AA;F;G XRF-;S AE;ICP;L AE;ICP;L AA;F;L MS;ICP;L MS;ICP;L AE;LA;S MS;GD;S 9312590 9312799 9214638 Sample treatmentlcomments Reference 931735 9313 135 Adsorption onto sulfhydryl cotton; detection limit of 0.I pg g-I Ag reported Sample was dissolved in nitric acid preconcentrated on a mercapto-acetoxy cellulose column and eluted with ammonium thiocyanate; recoveries were reported in the range 95-105% with RSD of 1.95% (n= 11) Sample was dissolved in aqua regia filtered and Al determined as acid solublelinsoluble fractions; detection limits were 0.33 ppm for acid soluble A1 and 0.1 ppm for acid insoluble Al and RSDs were 3.25% at 12.5 ppm and 2.8% at 13.3 ppm respectively Analysis of NIST SRMs 126 1A and 1263A; detection limits reported in the low ppm range Samples irradiated with intense femtosecond optical pulses were found to emit strong K-alpha lines with similar lifetimes in nitric and hydrofluoric acids; a strongly acid cation-exchange microcolumn was used to provide continuous-flow matrix isolation Sample was dissolved in 0.2 mol dm-’ nitric acid; Zeeman ETAAS gave RSDs for BYG 801-20 and BYG 805-20 of 4.42 and 8.98% respectively hydrofluoric acids; BCS CRM 346 IN nickel alloy analysis gave LOD 0.5 ppm As (ie.250 pg absolute) with RSD 3.5% for a 10 ppb ASV solution (n = 6). Flat and oblate samples were prepared polished and sectioned for enegry dispersive analysis; mixtures of gold (80-95%) silver (4-1 5%) and copper ( 1 - I 5%) were used as standards Dissolution with hydrofluoric acid and hydrogen peroxide and sodium fusion of the residue followed by anion-exchange chromatography and elution with nitric acid; RSDs of 1.9 and 8.5% were reported for the determination of B in iron disilicide and high-purity iron respectively with detection limits of 0.01 to 0.05 ppm Disaggregation in the solid state followed by aqueous extraction and alkaline extraction with sodium carbonate and zinc oxide; minimum determination level was 5 ppm Peroxide and phosphoric-sulfuric acid digest with nitrobenzene extraction; recoveries better than 96% were reported with RSD of 3% Rapid (25 min) high-pressure microwave digestion; Accuracy and precision for 1-10 ppm B in steel was satisfactory Pyrolytic graphite coated graphite tubes were used for ETV sample introduction of acid digests; the appearance time for Bi in nitric acid was later than for hydrochloric acid and nickel was found to increase the Bi signals in nitric acid; detection limits were typically 50 times better than those for conventional nebulization onto the sample and time resolved spectra were measured in nitrogen atmospheres; the RSD was 1.6% and a detection limit of 65 ppm was reported sensitivity factors with determinations below 20 PPm 9214438 Samples were digested in a sealed microwave vessel Microwave assisted digestion in nitric and Plasma was formed by focusing an Nd:YAG laser Neon as working gas gave improved relative 93lCI 333 931733 9311 638 92/44 13 92/44 1 7 931 I247 9312236 9312287 931786 9313153340R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 Table 1 SUMMARY OF THE ANALYSES OF METALS-continued Cr Steel Cr Steel AA;FL XRF-;S Mn Mo Mo N Ni 0 P P Steel Tungsten Steel Steel Titanium metal Steel Nickel alloys Super-alloys AA;FL AA;F;L AA,F;L MS;GD;S AA;F;L MS;GD;S AFETA;L AE;ICP;L c u Aluminium alloy c u Lead and zinc metal cu Copper nickel alloy c u Titanium metal Fe Lead and zinc metal Fe Tin-plate In Zinc metal Mg Aluminium alloys Mn Molten steel Mn Steel AA;-;L AE;ICP;S MS;-:S AA;FL AE;ICP;S MS;SI;S AA;F;L AE;ICP;L AA;FL AE;GD;S Technique; atomization; Element Matrix analyte form* Sample treatmentlcomments c o Steel and alloy AA;FL Preconcentration of Co on an ammonium tetraphenylborate ion-pair column supported on naphthalene using 245 bromopyridazol-5- diethylamino phenol) chelation elution with DMF; linear range 1-10 pg in 5 ml DMF RSD 1 Oh S,ample was dissolved in hydrochloric acid containing guanidine and formamide as interference inhibitors Accuracy of XRF measurement was found to depend on the relationship between the alpha coefficient and composition; an evaluation was made of 456 alpha-computing algorithms for the determination of Cr Oa-line electrolytic dissolution of solid metal with FI transfer of sample to AAS for direct analysis Direct insertion of sample in a graphite cup; detection of copper at ppb level with minimized interferences and RSDs of 5-20?40 sputtering; initial copper content was 75-85% at 870 K using 3 kV Xe+ bombardment but after 100 nm was removed this dropped to 6O-7O0h and then remained constant down to 1000 nm Extraction of Cu as APDC complex in diisobutyl ketone in hydrochloric acid containing tetrafluorohydroboric acid; interference from iron was minimized Surface aggregation of copper was measured with As for Cu; detection of iron at ppm level Corrosion of tin-plate was correlated with microscopic distribution of iron near the outer surface and oxygen was measured to a depth of 1-2 pm with this technique Sample was dissolved in nitric acid evaporated to dryness adjusted to pH 3.5 and extracted with 1- phenyl-3-methyl-4-benzoyl-5-pyrazolone IBMK the limit of detection was 0.07 ppm with an RSD of 2.0% ( n = 5 ) for 0.6 ppm In Alcid dissolution; RSD 1-3% Fine particles were separated from the bulk dust above molten steel with a cyclone prior to direct introduction into the flame; the sub-10 pm fraction correlated well with the Mn content of the steel distribution and the larger diameter of the anode the flatter the crater bottom.The use of a ceramic spacer and optimized discharge parameters were also shown to result in a flat crater profile A!; for Cr Saimple was mixed with 50% emulsifying agent Ainode geometry was found to affect electric field calcium carbonate and phosphoric acid; linear range 0-40 ppm Mo Salmple was dissolved in hydrochloric acid containing hexammine urea and glycine as interference inhibitors Aii for C A!i for CU A!i for C Diissolution in nitric acid; laser excited atomic fluorescence gave a linear range from 0.1 pg to 8 pg with analytical precision of 18% added to form the molybdophosphoric heteropoly acid which was extracted into butyl actetate prior to back extraction into ammonia 0.5 ppm with recoveries of 96-99% Sample was dissolved in nitric acid and molybdate Diissolution of sample in nitric acid; linear range to AA;F;L Pb Lead brass Reference 9312726 9311 114 9312 7 79 92/43 13 931805 9312628 9313093 931805 931863 931550 921435 1 931783 931 10 1 9 9311 115 931665 9312670 93x1 333 93/3093 93lC1333 9312074 9313078 931662JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 341R Table 1 SUMMARY OF THE ANALYSES OF METALS-continued Technique; atomization; analyte form* Sample treatmentlcomments AE;ICP;L Sample was dissolved in a mixture of nitric and hydrochloric acids evaporated to dryness and re- dissolved in water; a detection limit of 5 ppm and standard deviations of 0.00 1-0.004% for the 220.35 nm line were reported Dissolution of sample in hydrochloric acid boiled for 15 min and re-dissolved in aqueous nitric- hydrochloric acid mixture; linear calibration to 500 ppb reported with Pb recovery of 10 1 % Solid copper chips were analysed directly at reduced pressures revealing three distinct types of lead i.e.surface grain and homogenous matrix lead Optimization of a modified Babington nebulizer and a cyclone-type condensation chamber for detection of Re line selection for S; detection limits were 0.92 1.13 and 3.19 pg ml-' of S at 180.73 182.04 and 182.63 nm respectively Separation of sulfate from iron and other matrix elements was achieved using a selection of alumina microcolumns; measurement of S at 180.73 nm gave a detection limit of 0.3 ppm As for Fe As for Pb; linear calibration to 500 ppb for Sn with Sample was mixed with 5% hydrochloric acid Closely matrix-matched standards used in study of recovery of 10 1 Oh containing nitric acid to destroy carbides and aluminium was added to enhance sensitivity in nitrous oxide flame; Ti was determined in the range 10- 100 ppm Element Matrix Pb Steel Reference 9311 176 Pb Copper wire AA;F;L 9312 147 93x920 Pb Copper Re Metals S Steel AA;ETA;S AE;ICP;L AE;ICP;L 931467 9214295 S High-purity iron AE;ICP;L 931101 2 Sn Tin-plate Sn Copper wire MS;SI;S AA;F;L 931863 9312 147 Ti Steel AA;F;L 9214730 Th High-purity tungsten MS;ICP;L 9312230 Sample was dissolved in hydrofluoric and nitric acids evaporated to dryness and redissolved in 1% nitric acid; recoveries were better than 90% and the limit of detection was (0.1 ppb; the RSD at 10 ppb Th was less than 5Oh As for Th Samples were re-melted and diluted with iron to avoid fracturing problems; spark ablation at a high repetition rate followed by ICP excitation gave RSD for V of 0.3% Solvent extraction of vanadium from the iron matrix with N-benzoyl-N-phenylhydroxylamine and the organic phase was transferred into perchloric acid; the standard deviation and detection limit were 0.03 and 0.1 pm respectively Elements separated as their fluoride precipitates and recoveries improved for trace element ranges; precision and accuracy were 2 and ~O/O respectively Cr and Mo also determined for Ca Fe Th and U respectively Artificial saliva; corrosion of Ni was most significant; Limits of detection were 10 20 0.05 and 0.05 ppb Direct sputtering of sample Influence of metallographic structure on the 155.7 nm C line intensity was reduced if the sample was heated to between 400 and 500 "C; RSDs in the range 1-5% Spark ablation with relatively small interference from polyatomic species was described; detection limits of less than 100 ppb were reported; RSDs = 3% Metals were ground by the bottle and bead method into slurries; recoveries for Ir Pd Rh were 80- 100% U High-purity tungsten V Ferrovanadium MS;ICP;L AE;ICP;L 9312230 9214627 V Steel AE;ICP;L 931756 REEs Steel AE;ICP;L 9311 130 Various (3) Dental alloys AE;ICP;L 92143 I9 Various (5) Refractory metals MS;ID;L 9214473 Various Alloys Various Steels AA;-;S MS;GD;S 9214526 9214572 Various Steels MS;ICP;S 9214605 Various Precious group metals MS;ICP;S 93lC86342R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 Table 1 Element Various Various Various Various Various Various Various Various Various Various SUMMARY OF THE ANALYSES OF METALS-continued Technique; atomization; analyte form* AA;ETA;S Matrix Alloys Sample treatmentlcomments Salmple was sputtered directly onto a L'vov platform and analyte behaviour was normalized by adding nitric acid which converted all of the material to a single form Sample was digested in nitric acid introduced into an ion chromatograph coupled to a sequential ICP instrument RSD in the range 1.6-3.9% were reported Calibration data obtained from a GD diode-array spectrometer were used with step-wise multiple linear regression to train a neural network to correctly discriminate between the alloy classes Arid digestion of sample.Furnace-flame atomizer evaluated for analysis of impurities with RSDs of less than 0.14% Sample dissolved in nitric and hydrochloric acids for between 4 and 8 h; RSDs in the range 1.7-4.6% Metal coating thicknesses of 10-500 nm were measured with an accuracy of 0.5-2% Electrodeposition separated 90% of the matrix copper from the impurities in a warmed nitric and hydrochloric acid medium; isotope dilution was used to analyse NIST SRMs 394 and 395 Closed vessel microwave dissolution in aqua regia at 860 kPa was used to minimize contamination problems arc and liquid squeezed onto a copper mould. Pre-spark discharges of 20 s duration were applied at 550 V and 100 Hz and for the measurement cycle 350 V were applied detection was 0.5 ppm for trace elements in 99.99% pure silver Generation of ultra-fine dust particles with a spark discharge; the effect of plasma operating conditions were investigated and the analysis cycle time reduced to 90 s 0.5 ppb for Th and U and 0.01 ppb for Na and K respectively sensitivity.Cluster ions were the main source of interference but the method compared well with SSMS Careful control of nebulizer gas flow rate was used to minimize matrix ion effects Comparison of laser and spark ablation for solid sampling Spark ablation ICP-MS was compared with GDMS for conducting solids such as a 20 element NIST steel. The GDMS system was found to be the more sensitive of the two techniques Depth profiling of Al 0 and Si of samples exposed to different mineral acids Single set of relative sensitivity factors was used for all matrices with 30-50% accuracy covering ranges from 96 to ppb Sample preparation methods involving melting in an induction furnace pelletizing by direct powder compaction and preparation of beads from pre-oxidized materials were compared Spark ablation achieved with a thyratron triggered variable wave form source.The sample was then introduced to the ICP via a modified Meinhard nebulizer Dependence of background intensity upon chemical (composition was modelled for trace constituents 0.7 g of steel wire was melted for 20 s in a welding Sample was dissolved in nitric acid. The limit of Ion-exchange separation; detection limits were 2 and Dissolution procedure. RSDs of 15-2Oo/o at high Reference 93lC113 Iron and steel AE;ICP;L 93/434 Platinum Steels AE;ICP;L AE;GD;S 931682 931723 Copper zinc and nickel metals and alloys Aluminium alloys Metal coatings Pure copper AA;ETA;FL 931c9 5 3 AE;ICP;L XRF;-;S MS;ICP;L 9 3lC962 93/c977 931 1009 Platinum AA;ETA;L 931 1039 Steel AE;spark;S 9311087 Various High-purity silver Various Steel AE;ICP;L AE; I CP; L 9311 166 9311254 Various (4) High-purity tantalum Various High temperature alloys AE;ICP;L MS;ICP;L 9311256 93x1 3 13 MSiICPi- MS;ICP;S MS;ICP;S Various Steels Various Steels Various Steels 93/C 1323 93/C1325 931C 1330 MS;GD;S MS;GD;S 93lC1349 93/C15 18 Various (3) Steels Various Platinum XRF-;S 9311786 Various Ferro alloys MS;ICP;S Various Copper metal 931 1946 Various Nickel-based alloys XRF;-;S 9312034JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 343R Table 1 SUMMARY OF THE ANALYSES OF METALS-continued Element Matrix Various (3) Titanium alloys Various Titanium Various Steel Various Aluminium Various Copper and indium Various Aluminium and its alloys Various Steels Various (3) Steels Various Steels Various Low alloy steels Various Copper Various High-purity molybdenum Various (3) Tungsten alloys Various Steel Various (5) Steel and alloys Various High-purity copper Technique; atomization; analyte form* AE1aser;S MS;-;L MSGD;S AE;ICP;L MS;ICP;S MS;GD;S MS;ICPS MS;GD;S MS;GD;S MS;GD;S SIMS AE;ICP;L XRF;-;L Coprecipitation with indium hydroxide and masking of the titatnium with hydrogen peroxide; detection limits were 8.1 ppm for Fe 0.8 ppm for Cu and 1.4 ppm for Ni Sample machined and double etched with hydrogen peroxide containing etching.Preparation time was reduced from 3 h to 20 min and the pre- sputtering time from 1 h to 20 min Laser-induced emission spectral analysis applied to industrial and process quality control offered relative detection limits in the range 10-100 ppm Detection limits for Ag Cay Cd Fey Th TI U and Zn reported in the range 0.02-86 ppb; Precision for alpha emitters better than 0.4-10% (U) and Round robin study with an interlaboratory RSD of less than 17% Heated with 50% sulfuric acid on a sand-bath mixed with hydrogen peroxide and evaporated at 230 "C for 2-4 hours in a pressurized PTFE vessel; applicable to alloys with less than 0.5% Si Laser ablation instumental parameters optimized with respect to depth profiling; best resolution was achieved with 10 mm de-focusing.Ablation rates differed for low and high boiling-point elements removed from the surface. For N determination the ion chamber requires a 20 min evacuation to reduce the background. Before 0 is determined the argon must be purified with a zirconium oxide catalyst; LODs less than 20 ppm switched Nd:YAG laser; LODs were reported in the range 0.01 ppm (Nd) to 5.5 ppm (Ni) for an integration time of 0.18 s. The error was 5-10% for elements with an isotope content of 10-20 ppm Use of iron as basis for normalization of the relative ion yields for each analysed matrix. Relative ion yields ranged from 0.1 to 5 in argon and 0.2 to 2.5 for neon filler gases When the GD source was operated at 4 mA 1000 V with a jet type ion source a sample loss rate of 0.23 mg min-' was obtained for a gas flow of 0-1 1 min-'.with relative ion yields of 0.57 for Fe and 3.5 for Cr Washed rod-shaped sample was sputtered for 30 min for determination of metals and for up to 2 h when determining C 0 and C1 at ppb levels. RSDs of less than 3% were achieved structures and impurity composition for Al 0 and Si Automatic sample treatment system for introduction of hydride forming and non-hydride forming elements which used on-line acidification and hydride generation. Interference was insignificant for Ca up to 40 ppm 1 g of sample was digested in a mixture of nitric and hydrofluoric acids for 2 h; NIST SRM 898 was analysed using both palladium-magnesium nitrate and phosphate-magnesium nitrate matrix modifiers; RSDs were reported in the range 2.6-14.9% for Bi Pb Se Te and TI Nitric acid dissolution of sample; Zeeman ETA detection limits were 0.6 ppb for Cd and 160 ppb for Sb MSGD;S 0.5-5% (Th) For C determination contaminants need to be Application of LA for direct solid sampling using Q- Sections of alloys revealed a relation between AA;ETA;L AA;ETA;L Sample treatmentlcomments Reference 9 31203 8 9312065 9312075 9312 100 9312 193 9312 194 93/23 10 931240 1 9312402 9312904 9312908 931292 1 931297 1 9 3lC3067 9313079 9313 192344R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 employed for classification of steels and alloys based on multi-element analysis data (93/723). A GD diode-array spectrometer was used to generate calibration data and stepwise multiple linear regression was utilized to train the neural network to discriminate between classes of alloy.The manufacture of high silicon steel is characterized by the formation of a resistant surface scale (93/C 1349). Analysis for Al 0 and Si in steels was carried out by GDMS after the steel sample had been exposed for varying periods to different mineral acids. Depth profle analysis carried out after different pickling treatments revealed that there was a part of the surf-ace area that was rich in silicon and aluminium oxides which resisted acid removal and con- ferred brittleness on the steel. Steel samples have been analysed by GDMS following the application of different heat treatments including annealing hardening and tem- pering (92/4572). It was reported that the influence of metallographic structure on the 155.7 nm C line intensity was reduced if the sample was heated to between 400 and 500 "C.Low alloy steels have been analysed by GDMS using either argon or neon as the working gas (93/2904). Relative ion yields for analyte elements were normalized to the matrix response for iron. The variation in relative ion yield ranged from 0.1 to 5 in argon and from 0.2 to 2.5 when neon was used as the filler gas. Methods of sample preparation for the analysis of ferro- alloys by XRF have been evaluated (93/1786). These included re-melting in an induction furnace pelletizing by direct powder compaction and preparation of beads from preoxidized materials. Standards which had been previ- ously analysed by wet chemical methods were used for calibration purposes.The accuracy of XRF methods for the analysis of steels has also been examined from a fundamen- tal point of view (93/2779). It was found that the accuracy of the determination of Cr depended on the relationship between the alpha coefficient and sample composition. This was evaluated for 456 alpha-computing algorithms and it was found that those which employed constant influence factors could provide acceptable accuracy. 1.2. Non-ferrous Metals and Alloys The majority of abstracts received were concerned with the analysis of copper and to a lesser extent aluminium and associated alloys. Applications are summarized in Table 1 and selected developments are described in this section. Copper is a metal which is readily available in a high- purity form and sensitive techniques are required for the determination of impurities.Consequently plasma source MS is increasingly being applied in this field. The analysis of pure copper by spark ablation ICP-MS has been described (93/ 1946). A thyratron triggered variable waveform spark source was used to directly introduce ablated copper into the plasma but this resulted in instability of the discharge. However the addition of a modified Meinhard nebulizer in the sample introduction system allowed the detection of trace elements down to 1 ppm with RSDs in the range 1 - 10%. Pure copper has also been analysed using ID-ICP- MS (93/ 1009). Electrodeposition was used to separate about 90% of the matrix copper from impurities in a warmed nitric and hydrochloric acid medium.The ID technique was used to analyse NIST SRMs 394 and 395 (Unalloyed Copper). Glow discharge MS is particularly useful for samples that are conducting and can be easily shaped to fit the discharge cell. Thus GDMS has been applied to the determination of Cr and Fe in copper (9312908). A jet-type ion source was operated at 4 mA and 1000 V and a sample erosion rate of 0.23 mg min-' was achieved for a gas flow rate of 0-1 1 min-I. Relative ion yields for Cr and Fe were 3.5 and 0.57 respectively. A round robin study of the analysis of copper and indium metals by GDMS may also be of interest (93/2193). An interlaboratory RSD of less than 17% was reported. The distribution of Cu in a copper-nickel alloy was investigated using sputtered neutral mass spectrometry (93/2628).The surface aggregation of copper was measured directly by sample sputtering. The initial copper content was found to be 75-80% at 870 K using 3 kV xenon ion bombardment but after 100 nm had been removed this dropped to 60-70% and then remained constant to a depth of 1000 nm. Further work has been reported on the direct analysis of solid copper chips for Pb by ETAAS (93/C920). Operation at reduced pressures revealed the presence of three distinct types of Pb namely surface grain and homogenous matrix lead. Flame AAS is also useful for the analysis of high- purity copper if applied in conjunction with a preconcentra- tion procedure (93/3135). The sample was dissolved in nitric acid evaporated to dryness and was re-dissolved prior to preconcentration by passage through a mercapto- acetoxy-cellulose column.Analytes were eluted with am- monium thiocyanate. Recoveries were reported to be in the range 95-105% and the RSD for 11 replicate determina- tions was 1.95%. The application of a furnace-flame atomizer to the detection of impurities in copper nickel and zinc metals by AAS may also be of interest (93/C953). One of the more interesting methods applied to the analysis of aluminium alloys involved on-line electrolytic dissolution of the metal (92143 1 3). The sample preparation s,ystem was interfaced to a flame AAS instrument using flow injection sample transfer for the direct determination of Cu. It has been observed that irradiation of aluminium targets with intense femtosecond optical pulses produced X-ray emissions with similar lifetimes (93/2779).The strong K alpha line was employed for the measurement of A1 content. High-purity aluminium has been analysed by IDMS (93/2100). It was reported that the precisions obtained for the determination of alpha emitters such as Th and U were 0.5-5% and 0.4-10% respectively using this technique. Few abstracts were received concerning the analysis of precious metals in the year under review. A procedure has been described for the analysis of precious metals using ICP-MS with slurry sampling (93lC86). The metals were ground by the bottle and bead method and a suspension of the material was introduced directly into the ICP mass spectrometer for analysis. Recoveries for Ir Pd and Rh were reported to be in the range 80- 100%. A closed pressure rnicrowave dissolution procedure has been described for the preparation of platinum samples for analysis by ETAAS (9311039).The sample was dissolved in aqua regia at 860 k.Pa in a microwave bomb. It was claimed that this procedure minimized contamination problems. Microwave digestion was also employed for the determi- nation by AAS of As in nickel alloys (93/1638). The digestion involved the use of nitric and hydrofluoric acids in combination and was applied to the analysis of BCS CRM 346. The limit of detection for As was reported as 0.5 ppm (250 pg absolute) and the RSD for a 10 ppb AsV solution was 3.5% (n= 6). An atomic fluorescence method was described for the determination of P in nickel alloys (93/2074). Laser excitation was employed in conjunction with electrothermal atomization of the nitric acid digest of the sample.The linear range of the method was 0.1-8 pg. Finally high-purity molybdenum metal has been charac- terized using GDMS (93/2921). The sample shaped as a rod was washed in aqua regia rinsed with de-ionized water and dried. The rod was sputtered for 30 min for the determination of metals and for up to 2 h for the detection olf C C1 and 0 at ppb levels. Relative standard deviations of less than 3% were reported. It was noted that the determina- tion of Ti was difficult as a result of spectral overlap from molybdenum doubly charged species.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 2. CHEMICALS 345R 2.1. Petroleum and Petroleum Products Atomic spectrometry has been used for elemental analysis within the petroleum industry for almost as long as the techniques have been in existence.If anything the impor- tance of trace element analysis of petroleum and petroleum products is increasing owing to environmental pressures and the realization that trace elements in crude oil can some- times provide useful source rock indicators. This area therefore continues to provide a rich source of research topics for workers in the field of atomic spectrometry and progress is summarized in Table 2. In addition Marshall (93/629) has published a review (68 refs.) of applications of AAS which although superseded to some extent by tech- niques such as ICP-AES continues to be widely used throughout the petroleum industry. 2.1.1 Crude oil and fractions Until recently only nickel and vanadium porphyrins were used to any extent for characterization of crude oils and to provide additional correlations to be used alongside the traditional biomarkers such as steranes and triterpanes.However the increasing availability of very sensitive multi- element techniques such as ICP-MS has opened up the possibility of utilizing other trace elements which could not previously be readily measured on a routine basis. Olsen et al. (93/C973,93/C1317) have determined up to 35 elements in crude oils and shown that of these Br Co Cu Fe Mn Mo Nd Sb Se and Sr can provide useful data on petroleum migration and source rock. Although ICP-MS has the sensitivity to detect many of these elements directly following simple solvent dilution of the crude oil sample some elements particularly the lighter ones suffer from severe polyatomic interferences arising from the organic matrix and solvent.Techniques such as FAAS and ICP- AES generally do not have sufficient sensitivity to allow direct analysis after solvent dilution. The most common sample preparation approach for these techniques involves wet ashing of the sample (92/4293). Thus Ca Cu Fe Mg Ni and Zn have been determined using FAAS by heating the sample with sulfuric acid ashing the residue at less than 500 "C digesting the residue in hydrochloric acid and diluting finally with water. Knapp (93/C984) has described two systems for pressure controlled high-temperature microwave decomposition. These were operated at pres- sures of 1200 psi using a microwave oven and at 600 psi using a focused microwave approach (in collaboration with Anton Parr KG and Prolabo respectively).It was reported that these systems could be used to decompose all organic materials including oils and plastics in a single-step proce- dure. The alternative approach of extraction of metals into IBMK is viable and has been reported for the determina- tion of Ni and Pb by ICP-MS (93/2902) and V using FAAS (93/C 1623). Whereas solution-based techniques such as those described above are well suited to the analysis of crude oils the characterization of oil shale kerogens requires information not only on bulk trace element concentrations but also on their distribution between the kerogen and minerals or bitumen. Mercer et al. (92/4465) have used a combination of NAA XRD and electron microprobe tech- niques to study the organic-inorganic associations of trace elements in shale kerogen.Several elements (As Co Mo Mn Ni Sb Se and Zn) were found to have some association with the residual mineral-kerogen phases (i. e. insoluble in toluene-methanol or hydrochloric-hydroflu- oric acid). Only Mn was found to have no significant contribution in the organic fraction which was separated by density. The remaining elements plus V might therefore prove useful for source rock correlations. An alternative method for the characterization of kerogens was described by Uden et al. (9312068). The method which required a minimum of sample pre-treatment involved pyrolysis GC coupled with MIP-AES. The technique allowed the charac- terization of compounds containing As C N 0 P S and Se opening up the possibility of utilizing compounds containing these elements as biomarkers.In some cases on- line alkylation was carried out to improve chromatographic behaviour by adding reagents to the pyrolysis probe or sample or by packing them into the injection port. For direct determination of trace elements in petroleum products the most convenient approach from the point of view of sample preparation involves dilution of the sample with an organic solvent. In the case of ICP based tech- niques the introduction of such solutions can give rise to plasma instability reduced sensitivity and increased inter- ference from spectral bands or molecular ions. An elegant solution to this problem involves the introduction of sample in the form of an emulsion (see also J.Anal. At. Spectrom. 1992 7 349R). This approach was applied to the determination of Al Cr Cu Ni Pb and S in oil products in the range 100-300 pg g-l (93/3123). Organic solutions can also cause problems in ETAAS as a result of sample spreading and penetration of the surface of the graphite atomizer tube. Curtius et al. (93/C95) have addressed this problem by adding 1 1-1 7 ml of propan-1-01 to homogenize and stabilize a two-phase mixture of 2 ml of water and 5 ml of kerosene (sample). This allowed the determination of Pb using ETAAS. The measurement of volatile metal species presents something of a challenge to analytical chemists in the petroleum industry. One such example is the determination of trace metals in liquified petroleum gas (LPG).The corrosion of aluminium heat exchangers by mercury in petroleum gas streams is a well known problem but other trace metal impurities can also cause problems by poisoning downstream catalysts. Mercury in natural gas has been measured on-line using an automated system comprising a gold-impregnated sand trap to preconcentrate gaseous mercury and atomic fluorescence spectrometry for detection (93lC69). However if the determination of other elements is also required the application of an on-line approach becomes less practical. Homeier et al. (92/4464) have described a method for the determination of As Cu Hg Pb and Sb in LPG. Elements were adsorbed onto Amberlyst- 1 5 a commercially available cation-exchange resin.Mer- cury was then extracted with 20% aqua regia and the resin was then dissolved in a sulfuric and nitric acid mixture prior to the determination of the other elements using ICP- MS and ETAAS. For techniques which require sample nebulization (e.g. FAAS ICP-AES ICP-MS) difficulites can be experienced with volatile analytes due to selective volatilization in the spray chamber. A direct injection nebulizer has been used in ICP-AES to overcome this problem (931C1453). Selective enhancement of analyte signals was avoided since the sample was nebulized wholly into the plasma. Bagdi et al. (93/1030) have studied the sample introduction and atomi- zation of volatile alkyllead compounds in FAAS and shown that whereas at high sample uptake rates the composition of the vapour approaches that of the liquid-vapour equilib- rium at low uptake rates the sample completely evapo- rates giving an equivalent response for all alkyllead compounds.Thus FAAS was used for the determination of lead in gasoline containing an unknown mixture of alkyl- lead compounds by maintaining a low sample uptake rate. The workers also showed by measurement at two different uptake rates that it it was possible to obtain a measure of346R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Table 2 SUMMARY OF ANALYSES OF CHEMICALS Technique; atomization; Element Matrix analyte form* PETROLEUM AND PETROLEUM PRODUCTS- Ba Lubricating oil AA;F;L Ca Lubricating oil c1 Transformer oil CI Waste lubricating oil HI3 Natural gas MI3 Lubricating oil Mo Lubricating oil Ni Crude oil Pb Alkyllead Pb Alkyllead Pb Kerosene Pb Light hydrocarbons Pb Gasoline Pb Gasoline Pb Crude oil V Crude oil Zn Lubricating oil Various (8) Crude oil Various ( 5 ) Liquid petroleum gas Various (8) Oil shale kerogens Various Lubricating oils (wear metals) AA,F;L MS;ICP;L XRF-;L AF;CV;G AA;F;L AA or AE;F or 1CP;L MS;ICP;L MS;ICP;L MS;ICP;L AA;ETA;L AA;FL AA,F,L MSICP;L MS;ICP;L AA;F;L AA;FL AA;F;L Sample treatmenttcomments Sodium dodecanesulfonate and benzyltrimethylammoniumchloride added to samples to enhance atomization efficiency of air-acetylene flame Comparison of results obtained using direct solvent dilution (80:20 to1uene:methanol) with those obtained using sulfuric and nitric acid digestion in an autoclave ETV-ICP-MS used to screen waste oils for possible contamination by polychlorinated biphenyls; temperature programming used to differentiate organic and inorganic chlorine XRF used to validate results obtained using novel apparatus for determination of organic chlorine Automated system for on-line analysis utilizing gold impregnated sand traps to preconcentrate gaseous mercury down to 10 pg Hg As for Ca Use of matrix matching to remove interference on Mo determination by oil additives including calcium petroleum sulfonate and zinc dialkyldithiophosphate IBMK-nitric acid extraction procedure Speciation using ion-pair reversed-phase HPLC-ICP- MS; detection limits reported for inorganic Pb triethyllead chloride triphenyllead chloride and tetraethyllead of 0.37 0.14 0.17 and 3.9 ng respectively Speciation of alkyllead compounds using reversed- phase HPLC-ICP-MS; membrane drier used to desolvate mobile phase component solution with water and kerosene in order to improve stability and sensitivity with respect to pure organic solution Accurate determination of Pb in mixtures containing tetramethyl- and tetraethyl-lead was achieved by controlling volatilization during nebulization by adjusting uptake rate Propan- 1-01 added to form a homogenous three- Speciation and determination of alkyllead compounds by GC-AAS; detection limits reported for tetramethyllead and tetraethyllead were 0.1 and 0.25 ng respectively compounds with a limit of detection of 0.7 pg s-l and better than 5% RSD Ciipillary GC-ICP-MS used to speciate alkyllead As for Ni Extraction of V complex into IBMK with a limit of detection of 0.019 pg m1-I; interference from molybdenum reported AS for Ca Sample (20 g) heated with concentated sulfuric acid and the residue was ashed in a muflle furnace; the ash was digested with dilute hydrochloric acid and the solution reduced in volume and diluted prior to determination of Ca Cu Fe K Mg Na Ni and Zn Determination of As Cu Hg Pb and Sb at ppb levels by adsorption onto cation-exchange resin removal with acid eluent and detection with ICP-MS or ETAAS Determination of organic and inorganic associations of As Co Mo Mn Ni Sb Se and Zn Cobalt was used as an internal standard to reduce interference effects caused by lubricating oil additives and viscosity improvers MS or AA;ICP or ETA;L NAA or EPMA; -;S AEICP;L Reference 9315 142 93J1175 93tC3674 931 1 700 93lC69 9311 175 9214492 93129029 9214573 93lC57 93lC95 931 1030 9311933 93t2092 9312902 93lC1623 9311 175 9214293 92t4464 9214465 92t4606JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 347R Table 2 SUMMARY OF ANALYSES OF CHEMICALS-canfinued Element Matrix Various (10) Lubricating oil SRMs Various (4) Marine lubricating oils Various Lubricating oil (wear metals) Various Petroleum products Various (10) Crude oil Various Lubricating oil (wear metals) Various Volatile hydrocarbons Various Ash deposits Various Lubricating oil (wear metals) Various (7) Kerogen Various (8) Waste oil Various Lubricating oils (wear metals) Various Lubricating oil (wear metals) Various (6) Oil products Various ( 1 3) Lubricating oil Technique; atomization; analyte form* MS;ICP;L AA;F;L AE;S;L AA;F and ETA;L MS;ICP;L AE;spark;S AE;ICP;L XRF;-;S XRF;-;S AE;MIP;S MS;ICP;L AE;spark;S XRF-;S AE;ICP;L AE;ICP;L ORGANIC CHEMICALS AND SOLVENTS- A1 Organic reagents AA;F;L A1 Pharmaceuticals AA;ETA;L Br Halogenated hydrocarbons MS; M I P;L C Alcohols CI Explosive AE;ICP;L M S; I C P; L Sample treatmentlcomments Isotope dilution analysis for wear metals (Ag Cr Cu Fe Mg Mo Ni Pb Sn and Ti in SRM 1084a and 1085a Treatment of sample with mineral acid to dissolve metal particles and use of IBMK and non-ionic surfactant and a solvent in the determination of Cr Cu Fe and Pb Analysis time reduced in emission spectrography by ashing the next sample using the heat released by the discharge during the current spectral acquisition petroleum industry; includes example methodology Study of trace elements (Br Co Cu Fe Mn Mo Nd Sb Se and Sr) as source indicators Sample introduction system and operating conditions modified to improve detection of wear particles larger than 1-3 pm Direct injection nebulizer used to eliminate bias caused by selective volatilization of analytes Determination of composition of ash deposits on the heated surface of an oil-fired boiler Samples were filtered through a membrane which was then analysed using EDXRF with a cadmium-I09 source; detection limits were in the ng g-' range Pyrolysis GC-MIP-AES used to characterize samples using biomarkers containing As C N 0 P S and Se Determination of Ag As Ba Cd Cr Hg Pb and Se by direct aspiration of sample after dilution; detection limits were in the range 5-50 pg m-3 for high mass elements (>80 u) Detection of metal particles (>45 pm) by placing sample on the flat surface of a rotating disk electrode and ashing in a furnace at 400 "C for 30 s Wear metals separated from oil and presented to the spectrometer as a layer of intermediate thickness between thin and saturated; matrix effects calculated using fundamental parameters nebulization of aqueous emulsions; errors reported of less than 5% for a concentration range 100-500 pg g-I in the oil with high degree of accuracy from ICP-AES data for 13 elements Review with 68 refs.of applications of AAS in the Determination of Al Cr Cu Ni Pb and S in oils by Sulfated ash content (e.g. ASTM D874) estimated Study of enhancement effects of organic reagents and surfactants in FAAS; sensitivity enhanced 1 O-fold using binary system with sodium dodecylsulfate Procedures for cleaning labware and for sample and reagent preparation for determination of A1 at ppb levels SFC-MIP-MS was used to determine halogenated hydrocarbons at trace levels; detection limit reported in the low pg range with calibration linear over 3 orders of magnitude; 5% RSD Tabulation of emission lines in the IR for methanol ethanol and propanol in an ICP source Negative ion detection mode used in the determination of trace levels of C1 in 1,3,5- triamino-2,4,6,-trinitrobenzene Reference 931C390 9 3/40 7 931475 931629 93fC9 73 9311 185 931C I 45 3 9311656 9311 888 9312068 931 2334 9 312 6 8 6 9 312 7 8 8 9313 123 9313344 92146 14 9313 156 9312070 931322 1 93fC325348R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Table 2 SUMMARY OF ANALYSES OF CHEMICALS-continued Element Matrix c1 Chlorinated hydrocarbons c1 Halogenated hydrocarbons Cr Organic reagents c u Copper organo-complexes c u Solvents Fe Refined fats and oils Fe Pharmaceutical tablets Mn Terephthalic acid 0 Alcohols Pt Anti-cancer drug S Encapsulated drugs S Essential oil Si Siloxanes Sn Organotin compounds Sn Organotin compounds Sn Organotin compounds Sn Organotin compounds Sn Organic solvents and acids T1 Radio-pharmaceutical Yb Organic reagents Zn Anaesthetics Various (8) Solvents Various Pesticide residues drugs Various (I 1) Dicyclopentadienyl- magnesium Technique; atomization; analyte form* AA;ETA;L AE;ICP;L AE;ICP;S AE;ICP;L AA;ETA;L XRF-;S AE;MIP;L AA;F;L AE;ICP;L AA;ETA;L MS;ICP;L MS;ICP;L MS;ICP;L Interface described for GC or conventional nebulization sample introduction; GC-ICP-MS used to determine chlorinated hydrocarbons As as for Al; sensitivity enhanced 7-fold for Cr Injection of Cu pyrrolidin- 1 -yldithioformate into MS;MIP;L As for Br AA;F:L AA;FL supercritical carbon dioxide camer gas for 1.2- fold improvement in sensitivity compared with water Flow injection on-line extraction from water using bromoxine xylene or 1 :4 to1uene:xylene with membrane phase separator; enhancement factors of 10 and 16 respectively reported atomization at 2600 "C for detection of Fe in the range 5-100 ng g-I for 50°h oil-solvent mixture Determination of amount of iron oxide transferred from ink to tablet during manufacture; ink dissolved in nitric-hydrofluoric acids and Fe detected at 1-3 ppm level Direct analysis of powder using graphite rod sample insertion As for C Measurement of free cisplatin in samples by ETAAS Energy dispersive instrument used to monitor thickness of non-S-containing encapsulation coating on S-containing drugs Determination of acetylenic thiophenes by GC-MIP- AES; structure eludication in combination with GC-MS and GC-FTIR Determination of Si (siloxane in sulfuric acid process solution) using a nitrous oxide flame with standards prepared from octamethylcyclotetrasiloxane in sulfuric acid compounds collected on air monitoring cassettes using HPLC-ICP-AES organopalladium compounds; factors up to 19.1 were achieved HPLC-ICP-MS; limits of detection reported in the pg range Determination of tri- and tetra-organotin compounds using supercritical carbon dioxide as a camer for SFC-ICP-MS; detection limits were reported as 0.2-0.8 pg with RSDs of 1.3 and 3.4% respectively induced fluorescence signals using air-hydrogen flame isopropylether; detection limit was reported as 0.5 pg ml-I AA;F;L Use of L'vov platform with ashing at 1200 "C and Separation and determination of organotin Study of sensitvity enhancement using Speciation of organotin compounds using Study of effect of organic solvents and acids on laser TI.was extracted from aqueous solution using A s for Al; sensitivity enhancement 50-fold for Yb Indirect method for determination of lidocaine dicaine or procaine by formation of ion pair with zinc thiocyanide and extraction into 1,2 dichloroethane Preconcentration with rotary evaporator followed by detection of Cd Co Cu Fe Mn Ni Pb and Zn at ppb levels detector for GC magnesium oxide; PTFE was used as a Review of use of MIP-AES as element specific Salmple was oxidized in air at 100-500 "C to form AFFL AA;F;L AA;FL AA;FL AA;F;L AE;MIP;L AE;arc;S Sample treatmentlcomments Reference 9312066 9312070 92/46 14 931439 9 3x3059 931453 93lC 1439 93lC8 1 931322 1 93lC 1 92 9312822 9313309 93lC 1452 93lC340 931582 93lC 1 627 9312067 93/33 17 9311 155 92/46 14 9315 12 9214322 9214527 9214701 sublimating agent to improve detection limitsJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 349R Table 2 SUMMARY OF ANALYSES OF CHEMICALS-continued Technique; atomization; analyte form* MS;ICP;L Element Matrix Various Alkyllead compounds and halogenated hydrocarbons Sample treatmentlcomments Capillary GC-ICP-MS using modified torch and heated interface for the identification of compounds with boiling-points up to 320 "C; detection limits in ng g-I range Study of variation in magnitude of polyatomic interferences with instrumental operating conditions for xylene and propan-2-01 solutions Capillary GC-ICP-MS used to speciate alkyllead and alkyltin compounds and ferrocene and nickel diethyldithiocarbamate; absolute responses were in the low pg s-I range.pesticides using SFC-MIP-AES AES. Organochloride recoveries were 9 1 - 109% and organophosphate > 73%; carbamate recoveries were inconsistent New direct serial coupled r.f.generator claimed to be more efficient and stable for analysis of organic solvents Air-argon plasma used on commerical equipment for analysis of organic solutions (IBMK); Content of 50% air in the cooling gas gave a large reduction in carbon band and line emission and acceptable cyanide band emission levels nebulizer; matrix matched standards were prepared by adding EDTA chelates under buffered conditions after sonification to prevent precipitation; detection limits in the ng g-I range New MIP torch shown to overcome some limitations of capillary discharge tubes; splitless injection up to 1 pl possible; applications to compounds of Se Si and Sn described Review of optical systems for use with GC-MIP-AES; results presented for compounds containing Br C C1 F H and S; detection limits reported in the range 140-350 pg reagents in FAAS and ETAAS for sensitivity enhancement and matrix effect suppression Study of effects of 16 solvents on fluorescence intensity of Ca Cd Cu Fe Mg Mn Sr and Zn; solvents with moderate viscosity and volatility effectively increased intensity Study of effect of ten surfactants on sensitivity of various metals in AAS using an air-acetylene flame carbon dioxide argon or helium) via a hole in the lower electrode; the method was applied to Br C1 and I as well as to detection of metals Use of organic soluble platinum or palladium modifiers to increase maximum pyrolysis temperature for determination of As Bi Cd Pb Sb Se Te and Sn as dithiocarbamate extracts in IBMK Discussion of sample preparation procedures and chemical modification to eliminate interferences Novel gas sampling GD source for determination of C halogens and S compounds in gases; pg s-' mass flow levels SFC-MIP-AES with Cchelle spectrometer used for the separation and identification of metal porphyrins Supercritical fluid extraction of organometallics using carbon dioxide with or without methanol as co- solvent Separation and determination of halogenated Determination of pesticide residues using GC-MIP- Solutions (1 5% mlv) introduced via a V-groove Review (99 refs.) of uses of organic analytical Liquid nebulized into the plasma (air nitrogen Reference 93lC 1 3 93lC60 93lC85 93lC 1 79 93lC 199 93lC2 8 8 931508 Various Solvents MS;ICP;L Various Organometallic compounds MS;ICP;L Various Pesticide mixtures AE;MIP;L AE;MIP;L Various Pesticide residues Various Solvents Various Solvents AE;ICP;L AE;ICP:L Various (1 1) Penicillin G AE;ICP:L 931530 Various (3) Organometallic compounds AE;MI P; L 931604 Various (6) Various Various Various Various ( 1 1) Various (8) Various Various Volatile halogenated and sulfur compounds AE;MIP;L 931605 Organic reagents AA;F or ETA;L AF;ICP;L 931640 931689 Solvents Surfactants Organic solutions AA;F;L AE;spark;L 931790 93lC958 Solvents AA;ETA;L 931 1076 Metallothionein preparations Gases AA;F or ETA;L AE;GD;G 931 1 196 93lC1475 (non-metals) Various Porphyrins Various Organometallics AE;MIP;L MS;ICP;L 93lC 1488 93lC15333 50R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 Table 2 SUMMARY OF ANALYSES OF CHEMICALS-confinued Element Matrix Various Solvents Various Diethyl ether Various Organic compounds Technique; atomization; analyte form* AE;MIP;L Various Potassium hydrogen phthalate MS;ICP;L Various Organometallic compounds MS;spark;S Various (4) Nickel naphthenate AE;ICP;L Various Organic solutions AE;ICP;L CATALYSTS- C c o c s Ga H Mo 0 Pt Pt Re Rh Activated carbon catalyst supports H ydrodesul furization catalysts Alumina based silver catalyst Zeolites Activated carbon catalyst supports H ydrodesul furizat ion catalysts Activated carbon catalyst supports Catalysts Automotive catalyst emissions Alumina catalysts Alumina catalysts Sample treatmentlcomments Reference AA;FL Study showed that the intensity of elements could be varied by up to a factor of 6 in FAAS by varying position of impact bead in the spray chamber; could be used to obviate dilution MS;ICP;L Small volumes of sample injected into flowing stream 9312056 (1-4 ml min-') of dilute nitric acid (2%); Detection limits reported in the ng ml-I range but could be improved using a membrane desolvator Series of heterocyclic aromatic and aliphatic compounds were used to test compound dependence of elemental response factors for C C1 F N and 0 in GC-MIP-AES; the maximum variation found was 6% RSD Eight trace elements were separated from the matrix using Chelex- 100 resin prior to analysis using ETV-ICP-MS; limits of detection were 1 - 10 S,amples hydrolysed with organic solvent-mineral 9311956 ng g-' acid system and then incorporated into graphite electrode or pyrolysed first Determination of Ca Fe Mg and Ni using an air-argon-cooled ICP in IBMK solvent Air-argon-cooled ICP used to determine trace elements in organic solutions; advantages claimed included reduction in carbon molecular bands and thus better detection limits and no carbon deposition on injector .SIMS or XPS;-;S SIMS SIMS AA;F;L SIMS or XPS SIMS SIMS or XPS AE;ICP;L AA;ETA; L AE;ICP:L XPS SIMS or RBS 931207 1 9312320 9 3/23 64 9313 129 9313 163 Surface C:O ratios and surface functional groups measured after different chemical treatments using XPS and SIMS S1,atic SIMS used to study surface concentrations and depth profiles of Co and Mo on titanium dioxide alumina catalysts; results correlated with catalyst activity Dynamic SIMS used to study disposition of Cs on the surface of the catalyst before and after heat treatment; No migration from the surface observed Treatment with hydrofluoric acid provided total Ga concentration; controlled digestion with hydrochloric acid allowed measurement of only non-framework Ga species A,s for C 931242 1 9312603 9312452 9313338 931242 1 As for Co 9312603 A 5 for C PI extracted into xylene using potassium butylxanthate from aqueous solution at pH 5.2-6.2; interference from nickel noted Piirticle samples were collected directly from an exhaust pipe and digested in 30% nitric acid; volatile fraction also collected using a series of impingers and absorption tubes butylxanthate from sulfuric acid solution alumina on electrically conducting aluminium support; Rh was deposited from solution as normal and information on Rh coverage thickness and chemical form was obtained Re extracted into solvent with potassium Model catalysts prepared consisting of film of 931242 1 9311 156 9313 177 9314305 931245 1JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 351R Table 2 Element Sn Various W E ) Various Various SUMMARY OF ANALYSES OF CHEMICALS-CO~Z~~U~ Technique; atomization; Matrix analyte form* Catalysts AA or AE;F or 1CP:L Zeolites XRF;-;S Catalysts SIMS Hydrogenation catalysts SNMS or XPS INORGANIC CHEMICALS AND ACIDS- Au B Ba Be Bi Ca Ca cw) Cr c u Silver nitrate Salts of tetrafluroboric acid Stronium nitrate Beryl samples Silver nitrate Sodium chloride Calcium fluoride-carbon black dispersion High purity strontium preparations Zinc tungstate crystals Pure soudium chloride c u Sodium chloride Ga Coal and coal fly ash Pb Silver nitrate Pb Sodium chloride Pd Copper anode slime AA;ETA;S AA;FL AA;F;L AE; 1CP;L AA;ETA;L AA;F;L AA;F;L AA;F,air-CzHz;L AE;-;S AE;ETA;L AA;F;L AA;ETA;SI AA;ETA;L AA;FL AA;-;L Sample treatmentlcomments Reference 9312 146 Sample was mixed with 3 ml hydrofluoric acid evaporated to dryness then heated in a pressure bottle at 180 "C for 3 h with 6 ml aqua regia; range 0.8-250 ppm Sn Wavelength dispersive istrument used to determine REE at 0.1-1% mlm level by calibration with standards prepared using zeolite matrix and pure oxides; inter-element effects were corrected for by using mass absorption coefficients Review (75 refs.) of applications of SIMS to the examination of heterogeneous catalysts Combination of techniques used to study in situ activation of amorphous alloys of Au Cu Ni Pd and Zr to form dispersed metal-zirconium dioxide catalysts 9214386 9312646 9312993 Trace Au was separated from the matrix using 2 mol 1-' HCI. After filtration the Ag was extracted using 6 ml of 55% tri-butylphosphate-chloroform solution.Recoveries were 95- 105% No matrix effects observed using a nitrous oxide-acetylene flame Study of interference effects in air-acetylene and nitrous oxide-acetylene flames. Experiments performed on the basis of a factorial design Sample was fused with NaF treated with HzS04 and heated to remove fluoride. The cooled residue was dissolved in concentrated HCI and diluted with 3% HCl prior to analysis Ammonium chloride was employed for the separation of Bi by precipitation from the matrix in the presence of EDTA Coprecipitation with Mg(N03)z dissolution of the precipitate with HCI addition of NH4Cl and NaOH solutions and extraction with diethyldithiocarbamate-butyl acetate the presence of the carbon black from DDDC and tetramethlenedithiocarbamates (TMeDc) with IBMK 1 .9-fold enhancement in the signal reported due to Extraction of CrV1 using in the form of compounds Buffer employed was C:BaO:La203 (90:5:5) Tungsten spiral electrothermal atomizer was used to introduce samples directly into a d.c.-arc plasma.Optimization of operational parameters was described. Results obtained showed good agreement with ICP-AES 4 g sample dissolved in 100 ml HzO boiled for 1.5 min and the precipitate washed with hot H20.The filtrate is then dissolved in 100 ml of H20 and 50 ml of the resulting solution mixed with 1 drop of concentrated HN03 and 0.2 g of xanthate cotton. The cotton is mixed with 1 ml of concentrated HCl and 0.5 ml of 1:1 HN03 and boiled for 5 min to desorb Cu Slurry sample introduction using nickel as chemical modifier. Calibration against aqueous standards possible. RSDs of 2.1-5.7% were reported for Ga at the pg g-' level As for Bi As for Cu Extraction procedure for Pd from matrix outlined 9311 143 931470 92/41 72 9313 155 921434 1 9214 5 38 9311 179 921429 1 931499 931307 9312 150 9311028 921434 I 931654 93/57 1352R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 Table 2 SUMMARY OF ANALYSES OF CHEMICALS-continued Technique; atomization; analyte form* AA;ETA;L Reference 92146 17 Element s c Se Si Zn Zn Various (6) Various Various Various ( 1 1) Various (9) Various (8) Various (9) Various (4) Various (4) Various (10) Various ( 5 ) Various (5) Various (8) Matrix Waste water Sample treatmentlcomments :Sample was diluted 20-fold and an aliquot evaporated to dryness to remove sulfuric acid; the residue was dissolved in 10% HCl shaken with cupferron and extracted with chloroform; Sc was determined in the aqueous phase Mercury-palladium chemical modifier was employed. ,O. 1 g of sample was decomposed in a silver crucible by fusing with 1 g of NaOH + NaClO and the resulting melt was dissolved in HCl 0.1 g of sample was dissolved by heating in I ml of HCl followed by 3 ml of HN03.The residue was dissolved in 5 mol I-' HCl solution. A burner rotation of 30 degrees was employed Sample preparation procedure employing ultrasound is described which was claimed to decompose oragno-zinc compounds Various systems were examined for the extraction of trace impurities Investigation of the preliminary partial or entire precipitation of the macro-components as ZnS Review ( 1 2 Refs.) Modified sllica-gel packed in column. Solution containing metals passed through column and eluted with perchloric acid Methods developed are suitable for determination of metal impurities in high-purity salts for crystal growth for scintillation and acoustic applications Sample dissolved in glycerol or ethylone glycol Samples were buffered to pH 5.7 using sodium acetate and metals were extracted in the organic phase of DDDC-IBMK Platinum or palladium chemical modifier required Coal fly ash Pure boron AA;FL AA;FL 9312 I34 93lC877 Zinc concentrates AA;F;L 9313 13 1 Brine and common salt AA;F;L 9313296 Aluminium salts AA;F;L AA;F;L MS;ICP;L AA;FL 9214323 High purity zinc compounds 9214324 Ultrapure reagents Alkali and alkaline earth salts 9214367 921459 1 Alkali metal halides AA;F;L 931469 Chromium(iI1) chloride Brine waters AA;F;L AA;FL 931474 931658 Sodium and potassium chloride potassium iodide High purity chemicals AA;ETA;L 9316 17 AA;ETA;L AA;F;L Metals extracted by APDC-MIBK.Detection limits in the ng g-' range for all elements 931652 Lithium salts and various inorganic salts Metals extracted with 1 -phenyl-3-methyl-4- Elements precipitated with ammonium bromide and Direct analysis of solution; magnesium nitrate benzoylpyrazolone-5 in IBMK.chelated with EDTA employed as chemical modifier; Zeeman-effect background correction 931684 931690 9317 16 Silver nitrate AA;ETA;L AA;ETA;L Silver nitrate Phosphate samples AE;ICP;L Acid digestion with HF-HNO,-HCI in PTFE closed vessel followed by the same procedure using perchloric acid (rare earths) 931757 Various (20) Various (12) Various Various Various Various Various ( I 3) Monogermane and monosilane Red phosphorus High purity phosphorus Strontium preparations High-purity bismuth AE;-:S AE;d.c.-arc;G AE;ICP;G AA;FL AA;ETA; L 931782 931796 931997 9311 119 9311 131 Impurities preconcentrated by distillation of matrix at Electrothermal atomizer used for preconcentration Influence of the matrix on the response for Ca Mg Trace impurities were extracted from the matrix 550 "C into an Ar flow and sample introduction into the ICP and Na was studied using methyltrioctylarnmonium chloride-chloroform production of high-purity acids bases and solvents separation and preconcentration of a variety of elements were examined Review of use of ICP-MS for monitoring the Various extraction systems for the selective High-purity process chemicals MS;ICP;L 93J2486 High-purity copper salts AA and AE;F and 1CP:L 93J2123JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 353R Table 2 SUMMARY OF ANALYSES OF CHEMICALS-continued Technique; atomization; analyte form* AE;ICP;L Reference 9312724 Element Matrix Various (9) High-purity potassium nitrate Sample treatmenticomments (precipitation of the matrix solvent extraction and ion exchange) were optimized and evaluated on the basis of elemental spike recoveries and reproducibility Feasibility of various X-ray methods were examined for bulk analysis or individual particles Optimization of standard and sample preparation procedures for rapid and routine analysis Examination of the potential of the GDMS technique for the complete chemical characterization of fly ash to ppb levels Different methods for the preconcentration Phosphoric acid employed as a chemical modifier Investigation of effects of contaminant elements Samples were ashed (500-600 "C) and the ash was present in cyanide solutions calcined (1000 "C) and fused with CaC0,-NH4Cl at 1100 "C and dissolved in water - AE;XRFS AE; X R F; S MS;GD;S 9312746 93128 I9 9312933 Various Fly ash Various Fly Ash Various Coal fly ash Various (4) Zinc sulfate Various (4) Au metal plating solutions AA;ETA;L AA;F;L AA:F;L 9313272 9313 14 1 Various (2) Coke 9214405 Various (7) Fly ash AE;ICP;L 9314462 NUCLEAR MATERIALS- B Primary coolant B Uranium-zirconium alloy NP Enriched uranium solutions Pu Plutonium S Graphite Boric acid was determined by using the molecular band spectra of B,O type oxides Sample dissolved in H2S04-(NH4)2S04 Extraction procedure for 237Np was discussed Procedures described for the determination of Pu Reproducible and reliable sample preparation isotope ratios technique (high-pressure asher) was employed to simulate the operating conditions observed in the graphite packing of a nuclear power station Discussion of analytical figures of merit for the determination of 99Tc by ICP-MS Sample was decomposed in a PTFE pressure vessel with HCI and H202.Th was seperated by cation exchange using 1.5 mol 1 - I HCI Simple XRF method was developed for the determination of Th in aqueous solutions. The sample was introduced directly into the spectrometer in polythene bottles As for Th As for Pu Sample was decomposed in a PTFE pressure vessel with HCI and H202. Uranium was separated by ion exchange using 9 moll-' HCl preconcentrated U was fixed to the Re filament of the MS On-line separation of U from a variety of matrices using chelating ion exchange Optimization of plasma operating conditions for the determination of U in three organic solvents (xylene kerosine and benzene) was described. On-line solvent extraction employed to remove the matrix Performance of a hybrid K-edge-XRF analyser was discussed with reference to screening of nuclear materials.Details pertaining to matrix effects precision accuracy and detection limits were discussed Uranium matrix extracted using tributyl phosphate One step procedure for separation of Al Ti and Fe Laser ablation was employed for the direct Single bead of anion-exchange resin containing described semiquantitative determination of trace impurities in a uranium oxide reference material 9214390 AE;F;L IDMS MS;ICP;L TIMS;-;S 9311 153 9312060 92147 17 931333 1 AE;ICP:L - Tc Th High-purity titanium MS;ICP;L MS;ICP;L 9312244 9313 127 Th Aqueous solutions XRF;-;L 92/45 5 6 U Aqueous solution U Uranium U High-purity titanium XRF;-;L TIMS;-;S MS;ICP;L 9214556 92147 17 9313 127 9214556 U Spent nuclear fuels IDMS;-;S MS;ICP;L AE;ICP;L 931292 931834 U Sea-water U Organic solvents 9214 5 7 5 9311 827 Various (28) Uranium oxide Various Process liquors MS;ICP;L AE;XRF;L Various Uranium and sodium MS;ICP;L 931226 1 931580 9318 16 Various Purified uranium Various (3) Uranium AE;ICP;L AE;ICP;L Various Uranium oxides MS;ICP;L 931 1003354R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 Table 2 SUMMARY OF ANALYSES OF CHEMICALS-continued Element Various Various (8) Various (3) Various ( 13) Various (3) matrices Various (25) Matrix Industrial waste water Uranium oxide matrices Uranium oxide Nuclear grade uranium compounds Uranium-aluminium Uranium oxide Technique; atomization; analyte form* MS;ICP;L MS;IDSS;L MS;ID;- XRF;-;S AA:ETA;L AE;ICP;L Reference 93/29 15 9312606 9312605 Sample treatmentlcomments Comparison of ultrasonic and pneumatic nebulization for determination of actinides Technique employed for the certification of a uranium oxide reference material 13ulk of the matrix was removed by ion exchange and a further extraction step was required to isolate the elements of interest !samples were prepared in the form of double layer pellets with starch as a binding agent.Standards were prepared in a uranium oxide matrix Method for direct determination of Be Cu and Zn.Optimization studies and matrix effects described the uranium separated by chomatography. Trace level impurities were determined using a horizontally viewed ICP 9312737 9313089 9313337 !$ample dissolved in HN03 or HN03-HC104-HF and the relative proportions of tetraethyllead and tetramethyl- lead in the gasoline samples. A more conventional approach for the determination of individual alkyllead species in a gasoline sample is to use some form of chromatographic separation prior to measure- ment of lead using atomic spectrometry. This can be readily achieved by interfacing a packed column GC to a FAAS instrument through a heated transfer line (93/1933). In the latter paper absolute LODs were reported in the range 0.1-0.25 ng with precision of typically 2-6% relative.However sub-pg LODs have been achieved by coupling a capillary GC to an ICP-MS instrument (9312092). In both cases the interfaces could be easily removed allowing independent operation of the instruments. There is growing concern about the adverse effect on health arising from organically bound lead compounds in the environment. Potentially the largest contribution of these species may be derived from alkyllead compounds used in gasoline additives. Although the GC techniques described above can be used for speciation of alkyllead compounds in environmental samples (e.g. water soil) lengthy complexation and alkylation procedures are re- quired to increase the volatility of the trialkyl and dialkyl degradation products of the tetra-alkyl compounds.An alternative approach involving coupled HPLC-ICP-MS has been described (92/4573). It was reported that the determi- nation of inorganic Pb triethyllead chloride triphenyllead chloride and tetraethyllead could be achieved in a single run without the need for time-consuming pre-treatment and/or preconcentration procedures. Limits of detection were quoted as 0.37 0.14 0.17 and 3.9 ng of Pb for the compounds mentioned above respectively. 2.1.2. Lubricating oils The period under review has to a large extent been one of consolidation as far as developments in the detection of trace elements in lubricating oils are concerned with much of the work previously discussed in conference presenta- tions reaching publication. For example a method for the determination of Ba in lubricating oils by AAS using a dinitrogen oxide flame has now been published (9315 14 see also J.Anal. At. Spectrom. 1992,7 349R). The procedure which utilizes sodium dodecane sulfonate and benzyltrime- thylammonium chloride as enhancing agents gave good agreement with standard methods using dinitrogen oxide- acetylene flames (e.g. IP308) and might be particularly useful for smaller blending plants perhaps in remote locations. Similarly Jansen et al. (9214606) have now published their work on matrix eflects in the analysis of lubricating oils using ICP-AES. It was demonstrated that oil additives particularly viscosity index improvers can have a large effect on nebulizer efficiency and hence analytical results. However it was shown that these effects could largely be eliminated by diluting the sample sufficiently and by utilizing an internal standard.It is to be hoped that growing recognition of the importance of these effects will lead to a tightening of standard methods for analysis of lubricating oils by ICP-AES (e.g. ASTM D5 185-9 1 ) which currently do not specify some of the key analytical para- meters. It was also shown that ICP-AES could tolerate wear particles up to 10 pm in diameter. While most wear processes generate particles that are well within this range more unusual cases involving severe wear can generate particles significantly larger than can be efficiently intro- duced to and atomized in an ICP or flame. A rapid method has been described for the determination of wear metals in marine lubricating oils (93/407).These oils are especially prone to particulate precipitation during sample prepara- tion. The procedure involved the use of mineral acid to dissolve the metal particles and a mixture of IBMK and non-ionic surfactant to form stable solutions with the oil samples. Spark emission spectrometry is generally more capable of detecting larger wear particles than ICP-AES or AAS but requires careful optimization of electrode geomet- ries and ashing of the sample on the electrode prior to analysis (see for example 9311 185). Kauffrnan (9312686) demonstrated the detection of metal particles greater than 45 pm in diameter using a rotating disk electrode emission spectrometer. Samples were ashed on the electrode for 30 s at 400 "C prior to insertion into the spectrometer.The analysis of waste lubricating oils for recycling or disposal is an area of growing importance. Since waste oils can become contaminated with environmentally hazardous compounds arising from almost any conceivable source rapid screening techniques are required that cover as many of these potential contaminants as possible. In view of its inherent high sensitivity and rapid multi-element capabil- ity ICP-MS lends itself well to rapid screening of waste oils for heavy metals. Williams (93/2334) has described the use of this technique for the determination of Ag Ba Cd Cr Hg Pb and Se in waste lubricating oils after dilution with organic solvent. Limits of detection for high mass (>80 u)JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 355R elements were between 5 and 50 pg m-3 but those for lighter elements were degraded by isobaric or polyatomic interferences. Some of the most likely hazardous contami- nants in used oils are polychlorinated biphenyls (PCBs) originating from transformer oils. Usually these com- pounds if present are determined using GC with either ECD or MS. However sample preparation techniques for these methods are very time-consuming and so they are not well suited to the rapid screening of very large numbers of samples. A technique has been described which utilizes ETV-ICP-MS for rapid screening of oils for potential PCB contamination (931C367). In this approach temperature programming of the ETV allowed distinction between ‘organic’ and ‘inorganic’ C1. Only those samples which showed ‘organic’ C1 above a specified threshold were then submitted for full GC-ECD or GC-MS analysis.2.2 Organic Chemicals and Solvents This section of the review covers the analysis of organic chemicals reagents and solvents and the format is essen- tially the same as that of previous years (see J. Anal. At. Spectrom. 1992 7 349R). A summary of work concerned with the analysis of organic compounds and solvents carried out during the period under review is provided in Table 2. A comprehensive review (279 refs.) covering the applications of AAS for quality control in the chemicals industry has been published by Ebdon and Fisher (931633). The paper covered a wide variety of industrial applications and placed special emphasis on methods for sample decomposition and reduction of matrix effects.2.2.1 Chemicals As noted in last year’s ASU by far the most active area of research in the analysis of organic compounds at the present time is concerned with elemental speciation. Most of the applications reported involved the coupling of chromato- graphy with atomic spectrometric techniques. A review (68 refs.) has been published covering the use of GC and HPLC with AAS AFS AES and ICP-MS (9214590). Capillary GC is the most commonly applied chromatographic technique largely as the result of the increasing availability of commercial dedicated GC-MIP-AES instrumentation. Ap- plications of the technique in pesticide residue studies environmental surveying drug development and flavour research have been reviewed by Sullivan (9214527).There is however a growing realization that although very powerful the technique has limited scope in application to the elucidation of structural information. The technique can be used to provide element specific and empirical formula data to aid the interpretation of spectra produced by GC-MS and GC-IR systems (931C1489 931C3029 9313309). The application of GC-MIP-AES in this way for the identification of unknown compounds requires that elemental response factors (ERFs) are independent of chemical structure. Work carried out on the variability of response factors with chemical structure previously re- ported in a conference presentation has now been published (931207 1 see also J. Anal. At. Spectrom. 1992 7 349R). A series of halogenated and oxygenated heterocyclic aromatic and aliphatic compounds were studied and it was found that the variation in ERFs for C C1 F N and 0 were less than 3 6 5 6 and 5% RSD respectively for all of the compounds tested.Use of compound independent calibra- tions is thus possible if this level of error can be tolerated. However recoveries as low as 73% for organophosphorus determinations have been reported (931C199). Many of the problems encountered in GC-MIP-AES have been attributed to the capillary discharge tube em- ployed in commercial systems (e.g. wall reactions). Uden and co-workers (931604) have described an alternative concentric dual flow torch which may overcome some of these difficulties. Features of the device included the ability to provide splitless injection of up to 1 pl of sample without extinguishing the plasma a wide range of plasma operating conditions simplified background spectra and improved spatial stability.Another alternative that has been suggested is the use of a novel gas sampling GD source with GC-AES (931C1475). The source was used for the determination of C C1 F and S at pg s-* levels and might well prove useful for stand alone analysis of gases or ambient air in addition to providing element specific detection for GC. Develop- ments in optical systems for plasma emission detection for capillary GC have been reviewed by Camman et al. (931605). Improvements in the design of a monochromator for selective detection were discussed. A system was also described based on oscillating interference filters . Detec- tion limits were reported to be between 140 and 350 pg and dynamic ranges covered four orders of magnitude for Br C C1 and H.Although exhibiting many advantages over traditional ‘selective’ GC detectors MIP-AES lacks adequate sensitiv- ity for many applications and can be limited by reactions with discharge tube walls which necessitate the addition of different reagent gases. Sensitivity can be improved by as much as two orders of magnitude (typically sub-pg s-l LODs) by coupling capillary GC to ICP-MS (931C13 931C85 9312092). This approach has been applied to the determination of organometallic compounds and alkylhal- ides having Kovat’s retention index of up to 3422 (931C85). A system has been described which allows operation of an ICP-MS instrument with either packed column GC or solution nebulization by switching a T-valve and introduc- ing sheathing gas to the torch injector (9312066).The instrument was applied to separation and determination of dichloromethane 1 1,l -trichloroethane and trichloroethy- lene and gave detection limits of 2.6 2.2 and 2.6 ng respectively. Some degradation of solution LODs was noted however. Elemental speciation is particularly important for envi- ronmental contaminants such as organotin compounds where toxicity has been shown to vary greatly depending on chemical form. These compounds are generally insuffici- ently volatile for direct analysis using GC techniques and time consuming derivatization procedures have to be employed. Alternatively HPLC can be used in conjunction with ICP-AES or ICP-MS detection (931C340 931C 1627).However problems can arise if volatile solvents are employed. For example elemental response is affected by the change in solvent composition during gradient elution and LODs can be limited by blank levels and low or variable transport efficiency in the sample introduction system. Vela and Caruso (9312067) have demonstrated the advantages of combining ICP-MS with capillary SFC rather than HPLC for the determination of tri- and tetra-organotin Sn compounds which are amongst the most toxic forms. Detection limits were reported for tetrabutyltin tributyltin chloride triphenyltin chloride and tetraphenyltin of 0.26 0.80 0.57 and 0.20 pg respectively. Relative standard deviations were in the range 1.3-3.4% for five replicate 50 pl injections containing 0.5 ng of Sn.Supercritical fluid chromatography was also combined with a helium MIP-MS instrument and applied to the determination of halogenated compounds including pesticide mixtures (9312070). Abso- lute LODs were obtained for C1 and Br of 15 and 0.75 pg respectively. The linear dynamic range of the technique was established as about 3 orders of magnitude (up to about 50 ng). As mentioned in last year’s ASU (J. Anal. At. Spectrom. 1992 7 349R) SFC has also been used with MIP-AES but selectivity and hence LOD was found to be limited by spectral band interference particularly in356R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 the UV-VIS region (931C1488). An attempt has been made to overcome this problem by use of a high-resolution Cchelle spectrometer for detection of AE from the helium MIP.In addition to their use in chromatography supercritical fluids are increasingly being utilized in sample extraction procedures. The combination of supercritical fluid extrac- tion with ICP-MS has been shown to provide a highly sensitive and selective method for the determination of organometallics (931C1533). It was found possible to make use of the multi-element capability of ICP-MS to derive information about several metal-containing species simul- taneously co-extracted. However as with all extraction procedures the efficiency of partition must be established for quantitative work. The use of supercritical carbon dioxide as a carrier for sample introduction in AAS has also been demonstrated (931439).The study of sensitivity enhancement effects in AAS caused by organic reagents has been an active area of research in recent years (see J. Anal. At. Spectrom. 1992,7 368R). However only two primary papers concerning this topic have been published during the current review period (921582 92/46 14). A comprehensive review (99 refs.) has been published detailing the beneficial effects of organic reagents for sensitivity enhancement and reduction of matrix interferences in both FAAS and ETAAS (931640). The role of trace elements in pharmaceutical formulations is now at last being recognized by the industry and methods for their direct determination have been reported (931530 931 1 155). The use of atomic spectrometry for monitoring the activity of drugs in patients has also been discussed (93/C192).A paper providing advice on the determination of A1 in pharmaceuticals at ultra-trace levels may be of more general interest (9313156). It has been widely recog- nized that this type of determination is plagued by contamination problems. However the role of alumimium in Alzheimer’s disease is presently a topic of controversy within the pharmaceutical industry and a realistic assess- ment of the analytical problems involved in these measure- ments is to be welcomed. An indirect method for the determination of trace levels of the anaesthetics lidocaine dicaine and procaine has been published (93/512). The method involved the formation of a complex with zinc thiocyanide which was then extracted into dichloroethane. Zinc was determined in the organic phase by AAS and the concentration was related to the content of anaesthetic complexed.Applications of atomic spectrometry to the analysis of pharmaceutical packaging materials were also reported. Energy dispersive XRF was used to control the wall thickness of microcapsules for surfur containing drugs (93/2822). An ICP-AES method for the determination of the amount of an iron oxide based ink transferred to a pharmaceutical tablet during the manufacturing process was also discussed (93K1439). 2.2.2 Solvents Several papers have been published during the period under review concerning the effect of organic solvents on atomic spectrometric techniques including AAS AES AFS and MS. For techniques utilizing an ICP source the effect is generally detrimental particularly in ICP-MS where mole- cular ion interferences originating from the solvent can be significant.It has been shown that optimization of instru- mental parameters can result in some reduction in these matrix effects (931C60). However it is usually better to reduce the amount of solvent actually reaching the plasma. Hill et al. (9312056) have described a novel approach for the analysis of volatile solvents using ICP-MS in which small volumes of sample were injected into a carrier stream of dilute nitric acid (2%) using an FI valve. The plasma remained stable throughout if sample injection volumes were minimized allowing LODs in the ppb range to be achieved. However when a membrane drier tube was incorporated into the system to improve desolvation LODs were further reduced to sub-ppb levels.A membranephase separator was also used to separate organic and aqueous phases for FI on-line solvent extraction in FAAS (931C3059). In this approach Cu in water samples was determined with enhancement factors of 10 and 16 and sampling frequencies of 80 and 180 per hour by extraction into bromoxine and 1 4 toluene xylene respectively. Organic solvents can also have a detrimental effect on the performance of ICP-AES owing to such problems as thermal quenching of the plasma build-up of carbon on the torch and spectral band interference from molecules such as C2 and CN. A new direct serial coupled r.f. generator has been developed which was found to reduce quenching effects thus allowing improved stability when introducing volatile solvents (931C288).However molecular band interferences could still be present. Tang et al. (931508 9313163) described the use of a cooling gas consisting of 50% air and argon running on a commercially available 40.68 MHz ICP. Compared with the pure argon ICP the air-argon plasma offered several advantages for the analy- sis of organic solvents by AES. These included the avoid- ance of carbon build-up on the torch injector the reduction or elimination of molecular band interferences and for many analytical lines lower LODs. Unlike AES the introduction of organic solvents can have a beneficial effect when the ICP is used for AF measurements (931689). It was shown that organic solvents with moderate volatility and viscosity could effectively increase the fluorescence intensity of many elements.A similar effect is observed when organic gases such as propane are introduced into the plasma. Long and Bolton (93/2083) have carried out a series of experiments using AES and AAS to try to elucidate the mechanism. For AAS refractory elements were found to exhibit enhancements due to the role of elemental carbon (originating from the propane or the solvent) in assisting the dissociation of metal oxides in the plasma. However in AES this phenomenon was compromised by the reduction in the effective plasma power which accompanied introduction of the propane or solvent leading to a reduction in sensitivity for elements with high transition energies. For AFS measurement in flames the situation can be more complex with some solvents producing enhancement effects and others suppres- sions.Anwar et al. (93/3317) have studied the effect of organic solvents and acids on the laser-induced AF of Sn in air-hydrogen flames and concluded that analyte atomiza- tion was a direct function of the concentration of free hydrogen atoms present. 2.2.3. Catalysts There are many analytical methods available in the litera- ture for bulk elemental analysis of most common catalysts and support materials used in industrial chemical pro- cesses and these have been summarized in previous ASU reviews (see also Table 2). However in order to understand catalyst activity it is necessary to know not only the bulk elemental concentrations but also how the active compo- nents are distributed at the surface of the catalyst.Secon- dary ion mass spectrometry is perhaps one of the most powerful approaches available for this type of analysis. The application of SIMS to the characterization of heterogene- ous catalysts has been described in a comprehensive review (9312646). Specific investigations reported during the per- iod under review have included the characterization of the surface structure of supported catalysts using static and dynamic SIMS. In the former application the concentra- tion of the active component (molybdenum trioxide) on theJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 357R surface of the novel catalyst (molybdenum trioxide-cobalt oxidehitanium dioxide-alumina) was measured using SIMS and found to be correlated with the hydrodesulfuriza- tion reactivity of thiophene at atmospheric pressure (93/2603).In the latter study SIMS was used to check for potential migration of Cs from the surface of an alumina- based silver catalyst during high-temperature treatment (9312452). A combination of SIMS and X-ray Photon Spectroscopy (XPS) has been used to study the surface chemistry of commercially available activated carbons commonly used as catalyst supports (931242 1 ). Surface impurities were monitored after different chemical pre-treatments and were found to provide information which led to a better understanding of factors influencing precious metal disper- sion and catalyst activity in powder and shell type catalysts. These techniques have also been combined with sputtered neutral mass spectrometry (SNMS) to study the transforma- tion of amorphous glassy metal-zirconium alloys into carbon dioxide hydrogenation (dispersed metal on zirconia) catalysts (9312993).It was reported that studies with model substrates with defined layer structures indicated that the interpretation of depth profiles (e.g. ZrOJZr interfaces) was most straightforward using the SNMS data. It was found that not all metals were equally activated under pre- treatment conditions. Borg et al. (93/245 1) have studied the surface chemistry during preparation of an Rh-alumina catalyst. The model catalyst consisted of a flat electrically conducting support comprising a thin film of alumina on an aluminium foil onto which Rh was deposited from a solution of rhodium trichloride.The flat conducting nature of the support allowed the study of the catalyst surface using SIMS high resolution and angle dependent XPS and Rutherford backscattering. Information was thus obtained about the effective layer thickness of Rh and the extent to which the support was covered. Although in many cases the application of surface analysis techniques is necessary in order to elucidate the form of active metals on catalyst supports it is possible to obtain such information by careful application of classical chemical techniques. Monque et al. (93/3338) have used this type of approach in the determination of intra- and extra-framework Ga species in zeolite structures. The method employed relied on the fact that whereas treatment with hydrofluoric acid dissolved all of the gallium in the sample a controlled digestion with hydrochloric acid allowed the determination of only non-framework species.The zeolite structure was left intact by the latter procedure. Over the years extensive work has been carried out on the measurement of combustion product emissions from auto- mobiles and this has lead to the increasingly widespread utilization of exhaust catalysts in order to reduce these emissions. It is therefore interesting to note the appearance in the literature of methods for the determination of platinum emissions from catalyst equipped gasoline engines (9313 177). Particle samples were collected from the exhaust pipe of an automobile engine equipped with a 3-way cata- lytic converter and digested in 30% nitric acid for analysis by ETAAS.Volatile samples were collected in a series of impingers and absorption tubes. The emission concentra- tions of Pt under different loads ranged from 3 to 40 ng m-3. 2.3 Inorganic Chemicals and Acids Despite the growth in ICP-AES and more recently ICP-MS usage for the analysis of inorganic chemicals flame atomic absorption Spectrometry still accounts for a significant proportion of the abstracts received in this category. Although this perhaps reflects the economics of the situa- tion rather than the merits of the techniques in question it also demonstrates that with inventive front-end chemistry for separation and preconcentration FAAS can be employed for trace level analysis in a variety of complex matrices. Thus FAAS was used for the determination of trace levels of Pb (pg g-l) in salt and water samples after a preconcen- tration procedure on xanthate cotton (931654).In a related report Cu was also determined in the same matrix (93/654). Other applications involving FAAS included a description of extraction systems for the determination of A1 and A1 salts (92/4323); the indirect determination of nitro compounds (931685); and the detection of trace elements in strontium preparations (93/1111). The determination of trace elements in solutions contain- ing high amounts of dissolved salts is a recurring theme in this section of the review and reflects the considerable amount of effort expended on this difficult area of analysis. Difficulties with sample introduction and chemical physi- cal and spectral interferences are commonly encountered in such applications.It is not surprising therefore that in the majority of the applications reported some form of sample separation/preconcentration procedure was employed. A simultaneous solvent extraction procedure was reported for the determination of a suite of elements in brine water by FAAS (931658). The samples were buffered by NaOAc to pH 5.7. The metals were extracted into an organic phase consisting of DDDC-IBMK. The ratio of sample to organic was 1O:l and 100% recoveries were obtained for all elements studied. Cadmium has been determined in a sodium chloride matrix by FAAS using a coprecipitation method (92/4538). The metal was coprecipitated with magnesium hydroxide and dissolved in hydrochloric acid.Ammonium chloride and sodium hydroxide were added and Cd was extracted with sodium diethyldithiocarbamate (92/4538). Ultrasonic sample pre-treatment was used in the analysis of brine and common salt for Zn by FAAS (93/3296). This was claimed to result in the decomposition of Zn-organic compounds increasing sensitivity speed and reproducibility of the analysis. A method for the determination of total iodide in brines and sea-water by atmospheric pressure helium microwave plasma AES may also be of interest (93/2122). Work continues to be reported on the application of a high-pressure nebulizer system to the analysis of solutions containing high levels of dissolved solids (92x42 16 93/1082). In this system the liquid sample was forced through a special nozzle at high pressures (5-40 MPa).The liquid impacted upon a platinum-iridium plate with an orifice of 10-30 pm and the resulting constant flow (1-5 ml min-') of liquid through the orifice produced a fine mist. This system was compared with conventional pneumatic nebulization for the analysis of a variety of sample types of varying viscosity. As a result of the improved aerosol yield the high pressure nebulizer system provided an improve- ment in sensitivity of 2-3-fold on the basis of peak height and 6-8-fold on the basis of peak area measurements. Highly concentrated and viscous solutions which proved problematic or impossible with conventional nebulization could be introduced into the flame without difficulty with the high pressure system. Flow injection has been coupled with ICP-AES for the simultaneous multi-element analysis of sodium chloride (931496).Sample dispersion was mini- mized by the use of a mini-cyclone spray chamber. Matrix effects on the determination of 11 trace elements were discussed. Results obtained indicated that the use of FI reduced analytical signal drift and provided better signal reproducibility. A tungsten spiral electrothermal atomizer has been em- ployed for sample introduction into a d.c. arc for the determination of trace levels of Cu in pure sodium chloride (931703). Factors such as carrier gas flow rate current intensity vaporization temperature and the concentration of sodium chloride were studied. The technique was used358R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 for the determination of Cu in sodium chloride reagent and results obtained gave good agreement with those obtained using ICP-AES. Inductively coupled plasma atomic emission spectrometry continues to be heavily utilized for the analysis of inorganic chemicals. A method for the determination of REEs in phosphate samples has been reported (93/757). In this method complete dissolution of the sample was achieved using a multi-part acid digestion (a) dissolution with hydrofluoric-nitric-hydrochloric acids in a PTFE closed beaker and subsequent treatment with perchloric acid; (b) treatment with the same procedure as described in ( a ) but with fuming hydrochloric acid replacing perchloric acid; (c) application of nitric acid and fuming hydrochloric acid in a quartz vessel; and ( d ) final treatment with a hydrofluoric- perchloric-nitric acid mixture.High-purity phosphorous trichloride was analysed by ICP-AES combined with the use of an electrothermal atomizer for analyte preconcentration and sample introduction (931779). Details of other applica- tions involving ICP-AES are given in the tables. The increased requirements for the strict quality control of high-purity chemicals and reagents place considerable demands on the performance required by modern instru- mental analytical techniques. In semiconductor fabrication current acceptable levels for certain metal and non-metal contaminants are in the pg g-* range and by 1997 high- purity acids required for the manufacture of semiconductor devices with 0.25 pm geometries are expected to require impurity levels not exceeding 0.1 ppb. A comparison of direct analysis dilution and preconcentration sample pre- paration for ICP-AES ICP-MS and ETAAS for the ultra- trace analysis of high-purity acids has recently been presented (93/C2 15).Data on spectral interferences sample handling procedures and instrument parameters were dis- cussed. The performance of ICP-MS for the analysis of semicon- ductor-grade reagents has been reviewed (93122 1 7). The performance and limitations of quadrupole based instru- ments were explained and alternative sample introduction techniques including a novel nebulization system were highlighted. The advantages of magnetic sector based ICP- MS systems were outlined and a review of current and future levels of performance expected from a commercially available high resolution ICP-MS instrument discussed.A review on the quality control of high purity process chemicals using ICP-MS has also been reported (93/2486). A review (13 refs.) comparing ICP-AES and ICP-MS has also been published (93/2988). The main features and limitations of each technique are highlighted. The analysis of small volumes of hydrofluoric acid samples by direct injection nebulization ICP-AES has been reported (93/C 1420). A direct injection nebulizer constructed from materials resistant to hydrofluoric acid allowed multi- element determinations to be performed using less than 100 pl of sample. Steady-state signals were achieved with less than 20 pl of solution. Detection limits precision data and the effect of the concentration of hydrofluoric acid were discussed.Finally the application of tunable diode lasers to the control of high-purity material technologies has been described (9314475). The spectrometer employed a heated evacuated system for gas inputs and the use of the system for the analysis of water content of oxygen argon and germanium hydride was reported. Electrothermal AAS has been employed in a number of applications relating to the analysis of silver nitrate used in the photographic industry (921434 1 931690 93/7 16 9311143). Other applications reported for the analysis of inorganic chemicals by ETAAS included the determination of nanogram amounts of heavy metals in highly pure barium nitrate (931652); the determination of Mn Pb and Cd in zinc sulfate (9313272); and trace impurities in high- purity bismuth oxide and zinc oxide (9311 13 1).Electrother- mal AAS has also been applied to the analysis of environ- mental samples. The use of an alternative mercury-palla- dium chemical modifier for the determination of Se in coal fly ash has been reported (9312134). The modifier which contained equal amounts of mercury and palladium was added to the sample at a concentration of up to 0.1%. After digestion Se was determined either by the method of standard additions or by reference to aqueous standards containing the modifier. Good agreement was obtained with a certified coal ash reference material using this procedure. A slurry sample introduction procedure for the determination of elements of varying volatilities in coal coke ash and sludge samples by ETAAS has been described (93lC1366).The slurries were prepared by ultrasonic homogenization of the powdered sample in a solution containing 5% HN03 and 0.1% Triton X-100. Standard furnace programmes were employed and the results ob- tained showed good agreement with those obtained using conventional dissolution techniques. The precision ob- tained between slurries containing differing masses of sample were typically 10% and compared favourably with those shown between various sample decomposition proce- dures. Direct solids analysis using a low pressure electrother- mal atomizer for the determination of Ag and Cd in fly ash samples has been described (931C374). The analytical sensitivity could be controlled by varying the pressure of nitrogen in the atomizer.This could be used to analyse relatively high sample masses (3 mg). The precision of the determination was claimed to be of the order of 10% . The atomic profiles generated were used to study the form and location of the trace elements in the fly ash samples. Results obtained suggested that Ag and Cd were located on the surface of the fly ash and were not incorporated in the aluminium silicate matrix. It was suggested that in addition to providing quantitative results with high sensitivities and a large dynamic range this approach might be useful in determining the location of the analyte elements without the need to resort to more expensive and time-consuming traditional surface techniques X-ray fluorescence spectrometry continues to enjoy wide- spread use in the analysis of inorganic chemicals and related products.High-density brines are used to control high pressures during oil and gas well operations. These dense brines are solutions prepared from salts such as calcium chloride calcium bromide zinc bromide and/or combinations of these. During stages of completion exces- sive losses of these expensive brines to the production zone can occur. Before the brine can be re-used the composition of the brine needs to be re-formulated. A determination of the composition of the brine must therefore be undertaken so that the correct amount of salt is added to the depleted stock. The Compton scatter ratio method has been em- ployed for the correction of matrix interferences in the analysis of high-density brines (93/2008). This technique is advantageous in samples having a low atomic number in which the scattered intensity is high.A procedure using this technique for the determination of Ca C1 and Zn in brines was described. A method for the rapid characterization of coal fly ash has been outlined (93128 19). The optimization of the sample preparation technique has been described in detail. The data obtained compared well with wet chemical analysis. In a similar application the feasibility of different X-ray techniques have been examined for the analysis of fly ash samples as bulk or as individual particles (9312746). The measurement of low atomic number elements by TXRF in sodium bicarbonate has been reported (93/1879). The advantage of employing the total reflectance technique was that good SBRs and LODs could be achieved (ng g-') by virtue of the significant reduction of background scatter.An XRF system has been described for the study of theJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993. VOL. 8 359R composition of protective coatings (93/4462). This system was designed for the non-destructive analysis of thin multicomponent layers on substrates of large dimensions. The instrument was based on an energy dispersive spectro- meter and could be used for the simultaneous determina- tion of elements ranging from atomic number 20-92. The system was applied to the determination of the composition of protective layers on the surface of Ti anodes used for the production of chlorine. 2.4.Nuclear Materials Inductively coupled plasma mass spectrometry has now achieved almost universal acceptance as a powerful tech- nique for the analysis of nuclear and related materials. The high sensitivity multi-element capability speed of analysis and the ability to provide isotopic as well as elemental information combine to make this technique almost indis- pensable to the nuclear industry. The rapid growth of this technique in recent years has been reflected in the increas- ing number of abstracts received describing applications of ICP-MS in this field. The use of ICP-MS in an impurity assay of reprocessing uranyl nitrate has been reported (93/C 13 10). The benefit derived from the use of ICP-MS is that direct analysis is possible without the need for time- consuming solvent extraction steps normally required for analysis using either AAS or ICP-AES.The determination of trace metals in uranium oxide using ICP-MS with an on- line solvent extraction procedure has been described (92/4575). An aqueous solution containing uranium (2% m/v in 1 mol 1-' nitric acid) and triocylphosphine oxide in cyclohexane were pumped alternately through a PTFE tube where they were allowed to mix thoroughly. The organic phase containing the uranium was removed on-line by allowing the solution to pass through a microporous PTFE tube which owing to its hydrophobic nature allowed the organic phase to selectively permeate through its walls. This technique allowed determination of trace elements in uranium in the range 1-45 ppb. A procedure for the determination of traces of 237Np in isotopically enriched solutions of uranium has been outlined (93/2060).Neptu- nium-237 was extracted from 1 moll-' nitric acid using 0.5 mol 1-I thenoyltrifluoroacetone leaving 99% of the ura- nium matrix in the aqueous phase. The Np was re-extracted in 10 mol 1-I nitric acid and the resulting solution was heated to remove the acid. The instrumental parameters were optimized to suppress the spectral overlap between 237Np and uranium-238 from the matrix. The suppression of the analyte signal arising from high concentrations of uranium was corrected by the use of an internal standard. The analytical performance achieved was comparable to that obtained using alpha spectrometry. However the latter requires a tedious pre-treatment and measurement process.The ICP-MS technique has also been applied to the determination of Tc (93/2244). Spectral features and analytical figures of merit were described. A specially designed glove box containing ICP-MS instrument was used. A commercially available ion chromatography system incorporating an iminodiacetate functionalized chelating resin has been used for preconcentrating U prior to determination by ICP-MS (93/C292). The U was concen- trated on the resin using 1 moll-' ammonium acetate at pH 5.5 while the majority of the sample matrix not retained on the resin was passed to waste. Uranium was subsequently eluted from the resin by the addition of 1.25 mol 1-I nitric acid. Use of this matrix elimination procedure is claimed to allow determination of U in complex matrices at the ppt level.The optimization of the separation system was described and its application to a number of complex matrices outlined. The LODs linear range accuracy and precision were assessed using both a standard Meinhard concentric nebulizer and a CETAC ultrasonic nebulizer. The detection of actinides at the sub-ng 1-* level in industrial waste waters by ICP-MS has been described (93129 15). Conventional pneumatic nebulization and ultra- sonic nebulisation were compared. The direct analysis of solid samples by ICP-MS using LA sample introduction has also received attention. The semiquantitative determination of 23 impurity elements in a uranium oxide CRM has been reported (93/1003). Matrix-matched single point calibration was achieved by using another CRM from the same series of standards.Reproducibility was poorer when no internal standard was employed or when replicate ablations of the same area of the target were performed. The analysis of spent nuclear fuel is carried out normally after dissolution in 7 mol 1 - I nitric acid which precludes the analysis of fission gases (Kr Xe I) which are lost. Other fission products form insoluble residues which makes the complete characterization of the spent fuel difficult. In addition all spatial information is lost when dissolving the sample. Solid sampling techniques currently applied to spent fuels include mainly EPMA and gamma spectroscopy. This approach is limited as EPMA does not provide isotopic information and gamma spectroscopy may be limited to only a few isotopes.Laser ablation ICP-MS has been applied to the direct analysis of spent solid nuclear fuels (93/C13 11). The fuel samples were cut embedded in araldite and polished. The whole pellet including the cladding was analysed by LA-ICP-MS. This technique has also been applied to the direct determination of the isotopic abundance of U (93/C 1326). Samples were deposited onto cellulose filters as either solid or liquid samples. Results were presented for the analysis of a number of SRMs. Other applications of atomic spectrometric techniques to the analysis of nuclear materials are summarized in Table 2. 2.5. Process Analysis and Automation The number of abstracts received on process analysis and automation do not truly reflect the amount of activity in this field as the vast majority of applications are imple- mented in industrial settings and are not reported in the literature.Thus this section of the review cannot hope to give a comprehensive overview of activity in this important area but can only give a flavour of the sort of problems that are currently being addressed. Despite advances in instrumentation which have revolu- tionized the way analysis is carried out in the modem laboratory the expertise and acquired knowledge of the analytical chemist still remains outside of the instrument cabinet. As more and more of this knowledge is lost in rapidly changing labour markets there is a clear need to develop analytical instrumentation that will provide some degree of informed decision making capability.This may range from technique advisors providing some diagnostics on data or methodology to self-optimizing instruments or to the use of chemometric techniques to provide more sophisticated treatment of results. In the past few years applications of artijicial intelligence techniques to atomic spectrometry have begun to appear in the literature. The impact of this type of approach may change radically the way instrumental analytical chemistry is perceived. An intelligent system for the automation of quality assurance and control procedures in ETAAS has been reported (93/C1576).The system was developed to automate the US EPA contract laboratory programme for the analysis of waste waters. A control system for use with a high- resolution ICP has also been developed to comply with this programme (931C289).Application of the system was demonstrated for the determination of target elements in360R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 waste waters. An expert system for the interpretation of semiquantitative ICP-MS data has also been reported (93/C1596) as has an expert system for diagnosis of problem AAS data (931806). The combination of XRF with multivariate pattern recognition has been employed for metals screening and pre-processing decisions in respect of hazardous waste operations (93K257). X-ray intensities rather than quanti- tative data were used to generate patterns of specific generators based on quantitative spectral features. The performance of neural network models for calibration data in XRF spectrometry have been studied.Two training models were evaluated namely backward error propaga- tion and a genetic algorithm (92/47 10). An overview on the general usefulness and the theory of fuzzy sets for solving problems in the field of data analysis and analytical reasoning as well as for using neural networks for knowl- edge processing in analytical chemistry has been published (93/18 17). Recent progress in the development of intelli- gent systems for automated qualitative analysis in XRF and in ICP-AES were discussed. A review (32 refs) of on-line particle composition determi- nation has been published (9311 864). An article describing automated element analysis for control of the cement manufacturing process has been also been published (9311844).Finally a robotic system for the automated preparation of environmental samples for analysis by ICP- AES has been described (9313327). The system was de- signed for the preparation of several types of sample of increasing relevance to industrial plant operations rivers and well waters; surface waters and effluents; and soils sludges and sediments. 3. ADVANCED Developments in technique and methodology for the analysis of advanced materials are outlined in this section of the review. Key areas in which progress has been reported in the past year are highlighted in the text. A summary of reported analytical methods of relevance to the analysis of advanced materials is provided in Table 3. 3.1. Polymeric Materials and Composites X-ray fluorescence spectrometry is widely used in the plastics industry because the technique is able to provide a means of rapid non-destructive analysis with a minimum of sample preparation.Warren (93/284 1) has compared XRF with other non-destructive techniques such as neutron absorption and scattering gamma ray absorption and ultrasonic methods for the determination of fibre and mineral content in engineering plastics and composites. The applications described concerned the estimation of major components in materials formulations and com- ments were made regarding the feasibility of use for operation in a production environment. On-line applica- tions of XRF in polymer blending have been briefly described in a wider review of the subject (93/1803). A method has been described for the direct determination of S in co-polymer powders by energy dispersive XRF (92/4459).As with any technique for the direct analysis of solids the provision of appropriate calibration standards is required to achieve optimal accuracy. Strategies for the use of calibration standards in XRF have been outlined for a range of materials including synthetic plastics (93/ 1732). However it is not always possible to obtain an adequate range of plastic materials suitable for calibration purposes. The organizations which produce certified standards do not offer polymers as major matrix components. It is possible to use samples previously analysed (e.g. by ICP-AES) as standards for XRF calibration but the concentration range obtainable is normally restricted to production formula- tions.However XRF can still be used directly in conjunc- tion with a chemical sample preparation step. Thus a method has been proposed for the simultaneous determina- tion of heavy metals in plastics using fusion of the sample with sodium hydroxide in the presence of sodium nitrate as an auxiliary oxidant (93/1802). Sodium diethyldithiocar- bamate and sodium rhodizonate were used to precipitate As Ba Cd Cr Hg Pb and Sb which were then detected by XRF. This method was shown to be rapid and to give results that were comparable to those obtained for the recommended decomposition procedures for individual elements. MATERIALS Sample preparation was also the main area of attention in the application of AAS to the analysis of plastics in the year under review. The presence of heavy metals residues in plastics is subject to legal restrictions in many countries.The emission of particulates containing toxic metals is an important consideration in the operation of waste incinera- tion plants (92K4212). A study of the volatility of such metals in plastic wastes under conditions of combustion was carried out using cup-in-flame AAS. Samples of paints plastics and plastic additives were placed in a graphite cup and introduced into the flame. The temperature of the cup was increased by the flame by up to 1 100-1200 "C as measured by a thermocouple or pyrometrically . The volatil- ity of the selected metal was recorded as a function of temperature by AAS. The technique was applied to Cd Cu Pb Sn and Zn. A comparison of dissolution procedures based on microwave digestion and oxygen flask combustion has been reported for the determination of Cd and Pb in a range of materials including poIy(viny1 chloride) poly(pro- pylene) polyethylene polystyrene poly(ethy1ene terephtha- late) and polyamide (93/3245).It was found that both methods gave acceptable agreement with a conventional wet ashing procedure and were considered to be time- saving and cost effective pre-treatments for FAAS. The determination of A1 and Ti in poly(propy1ene) by FAAS and ICP-AES has been reported (93/1233). The sample was fused with potassium hydrogensulfate and the melt dis- solved in sulfuric acid prior to analysis. Precision was reported to be of the order of 8% relative for each element using this method. Germanium is widely used as a catalyst in the production of polyesters (93K879).It was reported that both dry and wet ashing using mineral acids offered suitable means of sample preparation for the detection of Ge in polyester by ICP-AES. It was noted that dilute hydrochloric acid (unlike sulfuric or nitric acids) was found to enhance the emission signal for Ge and this was attributed to improved sample transport efficiency arising from the formation of volatile chloride species. An interesting new technique has been proposed for the direct examination of waxes and other low melting-point solids by ICP-AES (93K972). The samples were melted and nebulized in the molten state at elevated temperature. The technique was used to monitor the metal content of waxes during the manufacturing process. Palla- dium has been determined in a polymer matrix by ICP-MS (93lC1348). The sample was decomposed using a sulfuric acid-hydrogen peroxide regime and rhodium added as an internal standard.A detection limit of 5 ng kg-l of Pd in the polymer was reported. Mass spectrometry has also beenJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 361R Table 3 SUMMARY OF ANALYSES OF ADVANCED MATERIALS Technique; atomization; Element Matrix analyte form* POLYMERIC MATERIALS AND COMPOSITES- Al Polypropylene AA;F;L Sample treatmentlcornments Fusion with potassium hydrogen sulfate and dissolution of melt in dilute sulfuric acid; A1 detected in the range 2- 125 pg g-' Cd Paper and pulp AA;-;L Cd Plastics AA;L;F Cr Butadiene rubber AA;F;L Fe Leather Mn EPDM rubber Pb Paint Pb Poly(viny1 chloride) Pb Paint Pb Poly(viny1 chloride) Pb Plastics Pd Polymer S Copolymer powders Sn Poly(viny1 chloride) Ti Polypropylene Ti Paints Various (5) Paints and plastic waste Various (7) Polycarbonate Various (3) Paper Various (5) Paper and insulating- Various (7) Plastics grade pulp AA;FL XRF;-;S 1CP;AF;L AA;ETA;S Laser;AE;S AA; ETA$ AA;L;F M S;ICP;L XRF-$3 AA; ETA;L AA;F;L XRF;-;S AA;F;S AA;ETA;S SIMS AA;F;L XRF-;S SEMICONDUCTORS- Ag Cadmium and zinc selenides AA;ETA;L Ag Germanium selenide films SIMS A1 Gallium arsenide-aluminium SIMS gallium arsenide Pressurized digestion of 1 g of sample with concentrated nitric acid in a PTFE crucible; detection limit 10 pg kg-' Comparison of microwave digestion and oxygen flask sample preparation methods with wet ashing for a range of polymers 5 g of sample was heated in a muffle furnace at 600 "C for 1.5 h treated with nitric acid and ashing was completed; the residue was dissolved in 2 ml aqua regia and diluted to 25 ml with water of Fe leached was 0.45 p g ml-I applicable to detection of manganese dioxide additive Dried paint samples were ashed at 475 "C and the residue dissolved in nitric acid; detection limit of the method was 10 ng ml-' and precision was 4% relative Direct sampling using 2-5 mg of solid; detection of Pb in the range 0.2-1% rnlm; linear range 0-40 mg Pb Direct sampling of paint layers in situ; system was miniaturized for field sampling; measurement at 220.35 nm with a detection limit of I % rnlm Pb Direct solid sampling for detection of Pb in the range 0.1-1.0% rnlm; RSDs between 5 and 10% As for Cd.Sample was decomposed using sulfuric acid and hydrogen peroxide; rhodium was used as an internal standard; detection limit of 5 pg kg-I Direct determination by energy dispersive instrument based on intensity of S fluorescence Sample was decomposed with a mixture of sulfuric acid and hydrogen peroxide or dissolved in THF; detection limit of 0.4 pg g-I Sn was reported As for Al; Ti detected in the range 2-25 pg g-I Sample was dried calcined and the ash fused with a borate flux at 1000-1 600 "C for 5-30 min Sample was introduced to the flame in a solid sampling cup for the direct determination of Cd Cu Pb Sn and Zn Direct determination of Cr Co Cu Fe Mn Na and Ni by solid sampling Imaging of distribution of AI Ca and Na on surface of paper Samples were calcined at (600 "C; detection of Cu Fe Mn K and Na Detection of As Ba Cd CrIIl Hg Pb and Sb after destruction of the polymer with sodium hydroxide and sodium nitrate as auxilary oxidant; preconcentration with NaDDC Analysis of aqueous extracts; maximum concentration Sample was ashed and analysed by EDXRF; Treatment with hydrochloric acid at pH 1.2; detection limit for Ag reported as 0.01 pg I-' Depth profiling of isotopic Ag dissolution in vitreous thin films of germanium selenide on silicon Quantitative analysis and characterization of depth distribution in heterojunction Reference 9311233 92/44 5 2 9313245 9312645 9214273 931 1693 9214542 93lC 138 931C1558 9312080 9313245 93lC I348 9214459 931842 9311 233 9312850 9 2 x 4 2 12 931574 931 I207 9311282 931 1802 9 3lC9 3 2 9312366 9311 278362R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 Table 3 Element As As Au B B Be C Cr c u c u Fe Fe Fe Ge Ge H In In In In Mg 0 Sb Si Si Sn Sn SUMMARY OF ANALYSES OF ADVANCED MATERIALS-continued Technique; atomization; analyte form* XRF-;S Sample treatmentlcomments under As pressure at 470 "C by total reflection detection; sensitivity for As La line was < 1 monolayer Quantification of As in silicon-silicon dioxide interfaces; As was reported to be enriched by a factor of 4000 at the interface deposits on silicon substrates; accuracy and precision of AAS was better for Au determinations; memory effects observed using Investigation of the surface of indiumphosphide Comparison of techniques for detection of alloy ICP-AES Sample was digested and B extracted as tetrafluoroborate ion associated with Ethyl Violet into toluene after adjustment of solution to pH 5; detection limit of 1 ng ml-l B Qunatitative determination of B below I ppm using sample rotation method Determination of dopant Be using sputtered neutrals for quantification Study of effects of latering ion beam parameters on SIMS quantification in single crystals Laser evaporation resonance ionization time-of-flight MS instrument; detection limit of below 1 x lo9 atoms cm-2 claimed and vapour phase decomposition methods for detection of dopant Cu Quantification of Cu segregation under oxygen ion bombardment Comparison of dry ashing and FAAS detection with a solid sampling ETAAS procedure using oxygen ashing Removal of metal contamination on the surface of silicon wafers was studied by TXRF As for Cu Measurement of film thickness on Polikor substrate Determination of Ge content and distribution interface characterization and film thickness measurements were discussed Use of caesium ion bombardment and detection of HCs+ ions for quantification of H content in hydrogenated silicon thin films Layer by layer determination of In by etching of film on gallium arsenide substrate with bromine in hydrobromic acid; detection limit of 1.3 x loi8 atoms ~ m - ~ using Zeeman effect background correct ion Comparison of TXRF backscattering spectroscopy Emission spectographic study of crystal growth Sample was sputtered onto a graphite platform which was then introduced to the ETA; determination of dopant content at about 500 ppm level Direct determination of In in single crystals using K alpha line (Quantitative determination of Mg dopant by detection of caesium cluster ion detection A s for C ,4s for In; detection limit of 1.2 x loi7 atoms ~ 1 1 7 ~ ~ ,4s for In ,4s for Ge ,4s for Au; precision and accuracy for Sn determination similar for both techniques Comparison of methods; ETAAS procedure employed platform atomization with orthophosphoric acid and magnesium nitrate as chemical modifiers; detection limit of 3.4 p g g-l; ICP-MS method limit was 0.5 ng g-l reported Matrix Indium phosphide Reference 931201 2 9 312 5 77 931C 143 5 9214722 9312 5 7 4 93/2465 9312972 931222 1 9312451 9312 52 3 931569 9311752 9312457 93/2033 93125 13 9312525 9214507 921455 1 931 1640 931 272 5 93/22 16 9312912 9214507 921455 1 9312033 93/C 1 43 5 931C 1598 Silicon-silicon dioxide SIMS Silicon AA and AE;F and 1CP:L Silicon and silica Aluminium film on silicon SIMS RIMS SIMS RIMS Gallium arsenide-aluminium Silicon gallium arsenide Silicon wafers Surface analysis Silicon SIMS Silicon Photoresists AA;ETA and F;S and L Silicon wafers XRF;-;S and L Silicon Silicon-germanium films Silicon-germanium structures Surface analysis SIMS XRF-;S Amorphous silicon films SIMS Cadmium telluride films AA;ETA;L Gallium arsenide Cadmium telluride AE;-;- AA;ETA;S Bismuth indium selenide Aluminium gallium arsenide Silicon Cadmium telluride films Gallium arsenide Silicon-germanium films Silicon Indium phosphide XRF;-:S SIMS SIMS AA;ETA;L AE;-;- XRF-;S AA and AE;F and 1CP;L AA or MS;ETA or 1CP:LJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 363R Table 3 SUMMARY OF ANALYSES OF ADVANCED MATERIALS-continued Element Matrix Zn Photoresists Various ( 4 ) Semiconductors Various Semiconductors Various ( 3 ) Silicon wafers Various ( I 5 ) High-purity gallium and indium Various (5) Photoresist Various ( 10) Molybdenum disilicide Various Semiconductors Technique; atomization; analyte form* AA;ETA and F;S and L SIMS SIMS MS;GD;S AE;-;S MS;ETV-ICP;L AE;ICP;L AE;HCL;S Various ( 3 ) Tungsten-titanium materials MS;GD;S Various ( 4 ) Silicon wafers Various (10) Silane XRF-:S AE;ICP;G Various ( 8 ) Arsine AE;ICP;G Various ( 9 ) Indium phosphide SIMS Various (27) Semiconductors SIMS Various Silicon Various (70) High-purity gallium AA or XRF; vapour phase decomposition;- MS;GD;S Various ( 3 ) Cadmium mercury telluride AA;ETA;L GLASSES- A1 Glass containers As Glass B Borophosphosilicate glass ETAAS SIMS and XPS AA;H y;G XRF;-;S Sample treatmentlcomments As for Fe Review of quantitative applications of the technique including to the determination of C H 0 and N Capabilities of SIMS instrument operated in secondary neutral analysis mode for more reliable quantification samples; applied to detection of C 0 and P at sub-ppm levels extaction and concentration of analytes on graphite powder collector Sample was diluted 10-fold in ethoxy ethyl acetate and evaporated into the ICP; standard additions were used for the detection of Cu Fe Mn Na and Ni; results were in good agreement with ETAAS Qunatitative coprecipitation of Co Cr Cu Fe Mn Ni Ti V Zn and Zr using lanthanum hydroxide Description of applications of hot hollow cathode discharge to materials including silicon and germanium; detection of impurity elements reported at ppm levels free sample preparation for the determination of Li K and Na at ppb levels surface contaminants including Cu Fe Ni and Zn for determination of Al C Cu Fe Ge Mg Na Sn Ti and Zr for determination of C Fe Ge Mg Mo Ni Sn and V Caesium ion bombardment for detection of negative molecular ions of Al Cu Ge Mg Pb Sb Sn Ti and Zn Fast xenon atom source bombardment for detection of impurities in gallium arsenide germanium and silicon at limits between 1Olo and loL3 atoms cm-$ surface distribution of B and S on silicon wafers also investigated measurement techniques for the determination of trace metals Procedure described for cryocooling liquid gallium to avoid impurity segregation Sample (0.5 g) was dissolved in hdyrochloric-nitric acid mixture and diluted to 25 ml; Ag and Cu were determined using platform atomization; In was determnied using tube wall atomization Direct analysis using sample cell accomodating flat Separation of base material from impurities by Investigation of methods of achieving contamination- Use of total reflection XRF for quantification of Use of sealed plasma for safe containment of sample Use of sealed plasma for safe containment of sample Study of the use of vapour phase decomposition Extracts from glass containers obtained during autoclave treatment were examined by ETAAS; the inner surfaces of the glass were examined post-extraction by SIMS and XPS Sample was digested in hydrofluoric and sulfuric acids and As was separated by solvent extraction with PhMe and back-extracted into water; the detection limit for As as oxide was 0.05 pg g-l the detection of B using multilayer crystal Application of wavelength dispersive instrument to Reference 931569 921446 1 9214522 931C342 931472 931568 931579 9 3 x 9 1 5 931C 15 19 9311981 9312046 9312041 9312520 93/26 12 9 312 7 4 5 9312893 9313 107 9214353 931768 9311989364R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 Table 3 SUMMARY OF ANALYSES OF ADVANCED MATERIALS-continued Element Matrix Fe Aluminium fluoride 0 Hafnium and zirconium fluorides P Borophosphosilicate glass films Si Silicate glasses Various (7) Fluorophosphate glasses Various ( 12) Glasses and ceramics Various (4) Glasses Various (4) Aluminium fluoride Various (9) Quartz Various Glass Various (1 6) Alkali silicates Various Optical glasses Technique; atomization; analyte form* MS;laser-ETV;S XRF:-:S XRF;-;S SIMS AE or MS;ICP and 1aser;L or S AA*-*- 3 MS;ICP and laser$ AA;ETA;S MS;ICP;L MS;ICP and laser$ AAS ICP-AES and XRF AA;ETA;L CERAMICS AND REFRACTORIES- A1 Lithium aluminate ceramics AE;ICP;S B Boron carbide MS;-;S B Boron carbide MS;-;S Ca Cement XRF;-;S Cr Aluminium nitride AA;ETA;L Fe Silicon nitride AE;ICP;S Fe Aluminium nitride AA;ETA;L Sample treatmentlcomments High-purity sample was atomized in a graphite cell under vacuum and the concentration of Fe determnied by three-step resonance photoionization using dye laser irradiation; detection limit reported as 4 x Use of a rhodium or chromium X-ray excitation source; a standard additions method was employed Method simultaneously measured both P and Si spectral intensities and corected for peak shift peak height changes due to chemical bonding effects g and Determination of surface silanol groups by detection Comparison of LA sampling and wet chemical of SOH+ cluster ion analysis procedures used in combination with ICP-AES and ICP-MS ]Review of AAS methods for the determniation of Al Ba Ca Cd Fe K Li Mg Na Pb Sr and Zn Laser ablation for semiquantitative determination of varous elements including Ca Mn Sr and Y in NBT SRM 6 12 glass !slurry of 50% suspended solids introduced directly into the atomizer for detection of Co Cu Fe and Ni; detection limits < 10 ng g-l suppression of boron volatilization from hydrofluoric acid solution; the method was applied to the detection of Li B Mg,Cr Mn Ni Co Cu and Zr Laser ablation of NIST SRM 6 I2 glass; detection of elements in the range 10-80 pg g-' Matrix was evaporated as SiF and trace metals were preconcentrated from water glasses by collector precipitation with hexamethyleneammonium hexamethylenedithiocarbamate and indium as the collector element Samples were fused and powdered and evaporated in a platinum crucible with hydrofluoric acid to remove silica and precipitated with sulfuric acid to remove lead; trace metals were preconcentrated as carbamates or dithiozonates and extracted with IBMK Study of the effect of mannitol dulcitol or sorbitol on Reference 9312601 931 199 1 931843 9312650 9214628 931630 931Cl 324 93/C1368 9312403 9312097 9312787 93f3108 Direct analysis of powder by introduction of ceramic ground to < 10 pm suspended in an aqueous slurry; recoveries > 95% Thermal ionization of the dicaesium metaborate cation for rapid and high precision measurement of isotope ratio for B Eloron was converted into sodium borate by fusion with sodium hydroxide or sodium carbonate directly on a rhenium filamen; B isotope ratios were measured directly on a rhenium filament Determination of calcium oxide in cement mix based on coal waste; samples were fused 1:5 with flux prior to analysis Sample (0.5 g) was decomposed with 6 ml sulfuric acid and 2 ml of nitric acid in a PTFE pressure veesl heated at 160 "C for 5 h Sample (0.05-0.5 g) was put into a 100 ml flask and diluted to volume with 0.5% (NaPO,) solution; the slurry was introduced into the ICP via a concentric nebulizer 93lC300 1 92143 15 9312994 9312 8 52 9311255 931 565 As for Cr 9311 255JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 365R Table 3 SUMMARY OF ANALYSES OF ADVANCED MATER1ALS-continu~d Technique; atomization; analyte form* AE;FL Element Matrix La Rare earth concentrates Sample treatmentlcomments Selection of flame type and spectral conditions for As for Al Electrothermal vaporization of single spherical Samples were heated with a hydrofluoric determination; La measured as oxide at 441.8 nm particle (< I mg) into the ICP acid-hydrochloric acid mixture; subsequent addition of sulfuric acid and volatilization of fluorides allowed total dissolution hydrofluoric acid selection spectral interferences pressure vessels; different kinds of zirconia could be distinguished by REE composition Optimization of instrument parameters to minimize matrix effects and sectral interferences Sample (50 mg) was ignited at 850 "C dissolved in 50% hydrochloric acid and evaporated to dryness; the residue was mixed with 5 ml ethanol and diluted to 10 ml with 5% aqueous hydrochloric acid Comparison of three sample preparation methods dissolution with hydrofluoric-sulfuric acid under pressure; decomposition with ammonium sulfate and sulfuric acid in an open vessel; and fusion with lithium borate in a graphite crucible Sample was dissolved in nitric acid and the liquid was evaporated in the presence of graphite powder Description of a method for preparing standards for the determination of Co Cr Fe Mn and Ni impurities in tantalum niobium and vanadium carbides borides and nitrides Samples were introduced into the atomizer directly in the form of a 2.5% mlv slurry; detection limits were reported at the sub-pg g-' level for Cd Cr Cu Fe Mn Ni and Zn Examination of Al C N 0 Si and Zr in ICP exhaust gases generated by atomization of slurries Use of special graphite electodes and sodium chloride as a thermochemical reagent to improve evaporation Use of r.f.sputtering of alumina zirconia and lead lanthanum zirconate titanate as thin films prior to acid dissolution and determination of major components Appllication of derivative spectroscopy to minimize spectral interferences in the determination of Al Ce Cu La Pb and Sm atmosphere; recoveries for REEs were in the range 94- 1 12% Optimization of electrode shape and evaporation aid; sodium chloride was found to be most sutaible for determination of transition metals Comparision of slurry and wet chemical preparation methods for detection of impurity elements Comparison of techniques; sample was decomposed in hydrochloric-nitric-sulfuric acid mixture in an autoclave with a PTFE liner for ICP-AES analysis Y-Ba-Cu-0 type superconductors as a method of phase analysis Sample was digested without loss of Zr using Investigation of matrix effects and wavelength Application of high-resolution ICP-MS to removal of Samples were decomposed with sulfuric acid in PTFE Sample excitation using oxygen-argon controlled Apparatus described for the selective dissolution of Reference 93/27 28 93lC3001 93lC3003 931830 931566 931 128 1 93/C 1305 9312408 9 3lC3072 9313 175 Li Lithium aluminate ceramics Li Lithium aluminate ceramics AE;ICP;S AE;ICP and ETV;S Y Silicon nitride AA or AE;F or 1CP;L Zr Zirconium nitride film REEs Gadolinium oxide REEs Gadolinium oxide REEs Zirconium dioxide AE;ICP;L AE;ICP;L MS;ICP;L MS;ICP;L REEs Europium oxide REEs Erbium oxide AE;ICP;L AE;ICP;L Various (6) Lead zirconate-titanate AE;ICP;L 92/44 16 Various Superconductors Various (5) Non-oxide ceramics AE;a.c.arc$ XRF;-;S 92/45 19 9214540 Various ( I I ) Silicon carbide AA;ETA;S 9214 568 Various (6) Ceramic powders Various (5) Alumina EPMA AE;d.c.arc;S 931529 931532 Various (5) Oxide ceramics 931564 AE;ICP;L Various (6) Yttrium oxide Ae;ICP;L 931589 9316 16 Various (14) Holmium oxide AE;d.c.arc;S Various ( 13) Holmium oxide AE;d.c.arc;S 931659 Various ( 1 3) Silicon carbide Various (66) Silicon carbide AA or AE; ETA or AE;ICP;L 1CP;L and S and NAA 931758 931759 931766 Various (5) Superconductors AE;ICP;L366R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Table 3 SUMMARY OF ANALYSES OF ADVANCED MATERIALS-continued Element Matrix Various (8) Superconductors Various ( 10) Zirconia powder Various (9) Superconductor Various (4) Superconductor Various (5) Superconductor Various (4) Superconductors Various (9) Silicon nitride Various (1 5 ) Titanium dioxide Various Zeolite process soluitons Various Titanate ceramics Various ( 17) Lead zirconate-titanate Various ( 12) Portland cement Various ( 14) Titanium dioxide Technique; atomization; analyte form* AE;ICP;L AE;ICP;L and S AE;arc;S AA;F;L AE;ICP;L AF;ICP;- A E; I CP; L XRF or AE;ICP;L XRF;-;L AE;ICP;L AE;ICP;L AES;ICP;L AE;ICP;L Various ( 10) Sintered alumina and zirconia AE;ICP;L Various (4) Yttrium oxide Various Perovskite ceramics Various Enamel frits Various (1 2) Silicon carbide MS;spark;S AE;ICP;L XRF;-;S AE;ICP and ETV;S Sample treatmentlcomments Dissolution method for determination of Fe Gd K La Mg Na Sn and Tm and major components with precision of <2% Four independent sample preparation procedures (fusion with ammonium hydrogen sulfate extraction separation by precipitation and slurry sampling) for the determination of Al Ca Cu Fe Mg Mn Na Ti V and Y IJse of double jet plasmatron for detection of Cr Co Mn Ni Al Si Fe V and Ti in Y-Ba-Cu-0 type material superconductor material using Y as an internal standard; minimum sample size 10 mg Detection of Bi Ca Cu and Si in bismuth-containing superconductor thin films !Sample was fused with sodium carbonate flux or other alkali fusion for determination of Al Ca Cr Cu Mg Fe Mn Ni and Zn trace elements including Cr Fe Hg Mg Mn Nb Ni P Pb Si Sn V Zn and Zr Detection of A1 and Na in aluminate solutions and Si and Na in silicate solutions used in zeolite preparation decomposition with ammonium sulfate and sulfuric acid and fusion with either lithium borate or sodium carbonate and sodium borate as sample preparation procedures for determination of macro-constituents hdethods for the determination of seven metal impurities and six dopants involving acid decomposition and fusion procedures Sample was fused with lithium borate in a graphite crucible for determination of Al Ca Cr Fe K Mg Mn Na Si Sr Ti and Zn; S was determined after fusion wuth sodium carbonate and potassium nitrate and extraction with water Sample (0.5 g) was heated with 10 g ammonium sulfate and 20 ml of concentrated sulfuric acid to dissolution; interferences were eliminated by matrix matching; detection limits were in the range 0.76-20 ng for Mg and Cu respectively sulfuric acid or 10 ml of a hydrofluoric-sulfuric (1 19) acid mixture in a PTFE vessel at 230 "C; alumina was decomposed in sulfuric acid alone; applied to detection of Al B Ca Cr Cu Fe Hf Mg Mn and Na Determination of Ce Cu Dy and Pb as oxides using isotope dilution approach Comparison of five sample preparation procedures including acid dissolution and fusion for determination of major and minor constituents Inter-element effects were compensated for using calibrations appropriate to Ca-rich and Ti-rich frits; results compare with those from wet chemical analysis Electrothermal vaporization of a slurried sample at 2 100 "C into the ICP in the presence of carbon tetrachloride as an evaporation aid Determination of Ag Al Pb and V in bismuth type Detection of major components (Ca Cu Pb Sr TI) Comparison of techniques for the determination of Comparison of acid pressure digestion Zirconia (0.3 g) was decomposed with 10 ml of Reference 931767 931774 931800 9311 243 9311 245 9311251 9311270 93lC1631 9311881 9312052 9312053 9312 142 9312 166 9312 192 9312626 9312668 931285 1 93/3 124JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 367R Table 3 SUMMARY OF ANALYSES OF ADVANCED MATERIALS-continued Element Matrix Various (4) Lanthanum oxide Technique; atomization; analyte form* Sample treatmentlcomments Sample (0.lg) was dissolved in 5 ml of 50% hydrochloric acid evaporated almost to dryness and the residue dissolved in I mol I-' hydrochloric acid and diluted to 10 ml with water; recoveries of Ce Nd Pr and Sm were in the range 93- 109Oh Various (28) Silicon nitride AE or MS;ICP;L Comparison of techniques; samples were passed and NAA through anion- and cation-exchange columns and W u was extracted by dithizone-chloroform prior to detection by gamma spectrometry were introduced into the ICP as aqueous slurries Various Silicon carbide AE;ICP;S Samples (4 g fine podwer with 3 pm particle size) Reference 931 3 1 30 9313 144 931335 I used in conjunction with the laser microprobe for the examination of polystyrene films (93/2372).Graphite furnace AAS rivals ICP-MS in its ability to provide a means of detecting ultra-trace levels of metals in polymer matrices. Polycarbonate is used as an optical material and it is important to determine the level of transition metals at ppb levels (931574). A graphite furnace AAS method was developed for the determination of Co Cr Cu Fe Mn Na and Ni using a solid sampling approach.The accuracy of the method was confirmed by comparative analysis. Applications to the analysis of optical fibres and polycarbonate disks were reported. Solid sampling has also been applied to the determination of Pb which is incorpor- ated as a stabilizer in poly(viny1 chloride) formulations (93/C138 93/2080). Approximately 3 mg of the solid plastic were introduced directly into the pyrolytic graphite coated ETAAS tube and atomized directly. No background correction was required and calibration was achieved using aqueous Pb calibration standards. A less sensitive analytical line was used for the determination of Pb in the range 0.1- 1 O/o m/m.Relative standard deviations in the range 5- 1 0% were reported for this met hod. Sample preparation methods for the determination of Sn in poly(viny1 chloride) by ETAAS have been described and compared (93/842). Procedures based on the decomposi- tion of the plasticized polymer in sulfuric acid and hydrogen peroxide or by dissolution in THF yielded detection limits for Sn of 0.4 and 2.7 pg g-l respectively. The THF method was reported to be simpler and less time consuming. Extraction procedures using nitric acid and diethyl ether were not found to be suitable for quantitative work. The application of glow discharge AAS to the examination of solid plastics including poly(viny1 chloride) by compaction with copper powder may also be of some interest (93/C1626).In a more extensive investigation GD- AES has been applied to the study of acrylic and polyester coatings and paint and lacquer layers on steel sheets used in the automotive industry (93K1497). It was claimed that the technique was applicable to both conductors and non- conductors alike although no details were given in the abstract concerning the construction of the atom cell. Continuous depth projiling of these materials was achieved for a number of elements simultaneously from surface dimensions (a few nanometre) up to a range of several hundred micrometres. Polymeric materials continue to be employed indirectly in the development of methodologies for the determination of trace elements.The use of polymeric substrates for the preconcentration of trace metals has continued with poly- urethane foam being the most popular choice (92/4418 92/4672 93/797 93/ 1 160). Macroporous poly(viny1thio- propionamide) chelating resin was reported to provide enrichment of trace noble metals with recoveries greater than 92% even after multiple re-usage (93/3252). In a related study a microporous poly(viny1phosphoramidic acid) resin was found to selectively adsorb Dy Er Ho and Yb ions from solution at pH 4-5. Poly(tetrafluoroethy1ene) has been used in slurry form as a volatilization agent for the determination of refractory elements by ETV-ICP-AES. Analytes such as B Cr Mo Ti and V (93/C3068) and Nb Ta U and Zr (93/C3073) were converted into volatile fluorides in the presence of the polymer and were easily vaporized into the plasma thus circumventing the prob- lems of carbide formation.The analysis of paints and coatings continues to be a subject of interest and a review of the application of ICP- AES in this area has been published (93/1250). The determination of Pb in paints in the field is becoming increasingly important for reasons associated with safety health and the environment. Portable XRF analysers are particularly suitable in this type of application (93/ 1842). An XRF detector was evaluated for the measurement of Pb in paint on military structures in West Germany (93/1772). It was found that a standardization approach could be used to compensate for the effect of the substrate on intensities. The unit was able to detect Pb base paint hidden by layers of Pb free paint.In an alternative approach to the problem laser induced breakdown spectroscopy (LIBS) was used for in situ detection of Pb in paint layers (93X1558). Laser pulses were focused on the painted surface to produce a micro- plasma which vaporized material and stimulated Pb atomic emission at 220.35 nm. It was observed that it was possible to generate depth profiles for paint layers by repetitive sampling at a fixed location. The components of the LIBS instrument were miniaturized in order to fit into a suitcase for portability. An LOD of 1% m/m was reported for Pb in paint using this instrument with a calibration range of up to 11% m/m. The direct analysis of paint chips for Pb using slurry sample introduction for ETAAS has also been reported (93/C1589).Several abstracts were received in the year under review concerning applications of atomic spectrometry in the paper industry. Wavelength dispersive XRF has been used in the detection of ring formation and failure of lime kilns and in the determination of pigment distribution in alkaline papers (93/1820). The chemistry of paper surfaces has been studied by SIMS imaging (93/1207). The sensitivity of the technique for elements such as Al Ca and Na allowed mapping at concentrations below those detectable by SEM-energy dispersive X-ray methods. It was reported that A1 was distributed less evenly over the fibre surface than the other elements. Laser ablation ICP-MS has been applied to368R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 the direct analysis of wood andcellulose materials (931C349).It was noted that the method could be used to rapidly analyse wood core samples according to date of growth. Solution nebulization of digested samples into the ICP-MS was reported to provide a satisfactory alternative approach. Sample preparation methods for the determination of Ca Cu Fe K Mn and Na (9311282) and Cd (9214452) by FAAS in pulp and paper have also been reported. 3.2. Semiconductor Materials 3.2.1. Silicon-based materials Non-destructive techniques play an important role in the characterization of silicon wafers. Perhaps the most signifi- cant advance in this field in recent years has been the advent of total reflection X-ray fluorescence spectrometry.Several reviews of the principles and applications of the technique concerning the surface analysis of semiconduc- tors have been published indicating the increasing popular- ity of the approach (9214632 9311892 9311990). A patent describing an instrument to be used for the detection of metal impurity on the surface of a single-crystal semicon- ductor may be of interest (9311910). The technique can be applied to the quantitative determination of surface con- taminants on silicon wafers (9311931). Calibration of response for Cu Fe Ni and Zn was achieved by use of a microdrop contamination of the wafer. Metal impurities in the wafers were shown to be condensed in a very small region near the centre of the dropped area. A relationship was derived between the intensity of the X-rays from the impurities in the condensed area and that from impurities distributed uniformly over the wafer surface in order to estimate analyte concentrations.Monochromatic excitation was used for grazing incidence XRF in order to improve penetration depth definition in depth profiling in modified silicon wafers (93/1983). A study was made of thin Cu and Ti metallization layers on silicon and of As dopant concentration profiles in wafers. It was reported that this technique could be used to investigate the effect of annealing non-destructively. Other applications of TXRF described include the detection of heavy metals in im- planted silicon (9311733) and the detection of the most important impurity elements (Cu Fe and Ni) in silicon ultra-large scale integration devices (931201 7).A study has been made of the removal of metal contamination on silicon wafers using dilute acidic solutions (93/1752). Wafers were cleaned using hydrochloric hydrofluoric nitric and acetic acids and residual Fe contamination was monitored by TXRF. It was found that hydrofluoric acid cleaning left a higher concentration of Fe on the wafers compared with the other acids. The study of the sources of contamination in semiconduc- tor materials and point-of-use high-purity chemicals re- quires the application of a variety of techniques. A recent paper cited the use of ICP-MS AAS TXRF and vapour phase decomposition in the investigation of cleaning and etching processes (93K1308). Both TXRF and ETAAS have been used in combination with the vapour-phase decomposition (VPD) preparation procedure as laboratory methods and for in-line monitoring (931C1306).The VPD procedure was also combined with ICP-MS to allow the measurement of more than 30 elements on wafer surfaces with LODs of the order of 1 x lo7 atoms cm-2. Metal impurities in silicon-on-insulator material were character- ized by TXRF (9311 192). The results obtained were compared with data obtained by AAS and SIMS. A comparison of the performance of TXRF and VPD-AAS for the detection of metallic impurities in silicon has also been reported (9312745). In the latter case TXRF was also used for VPD detection. There have been relatively few reports of the application of plasma emission spectrometry to the analysis ofsemicon- ductors in the period under review.Relevant methods are summarized in Table 3. The use of ICP-MS is beginning to predominate in such applications owing to the inherent sensitivity advantage over the emission technique and as a result of its speed in performing multi-element determina- tions (93x1 306). Extremely high sensitivity can be ob- tained by ICP-MS if electrothermal atomization is used instead of the more conventional nebulization approach for sample introduction (9312989). Both modes were employed for monitoring impurity levels in silicon and chemical cleaning baths used in large scale integration manufacturing processes. Another application of ETV-ICP-MS reported involved the analysis of photoresist used for very large scale integrated circuits (931568). Samples were diluted 10-fold with ethoxy ethyl acetate and a standard additions ap- proach was employed for the detection of Cu Fe Mn Na and Ni in photoresist.Detection limits for Fe and Na were reported as 0.06 ppb and 0.2 ppb respectively. Flow injection ICP-MS has also been applied to the determina- tion of trace metals on the surface of silicon wafers (931C371). The sample was prepared by treatment with hydrofluoric acid solution and vapour in order to etch the silicon oxide layer and collect the sample in a small volume. The FI system was used to inject samples of 20-500 pl into a carrier stream introduced into the ICP-MS instrument which then performed multi-element analysis. However for some elements unspecified in the abstract the FI-ICP-MS sensitivity was insufficient and measurement was achieved using ETAAS.A method involving cool plasma ashing for the determination of Th and U in electronic-grade chemi- cals by ICP-MS has also been described (93/C1307). An LOD of 25 ng kg-' was guaranteed for these elements using this approach which was also found to be suitable for 16 other elements of major interest. The results were verified by NAA analysis and Zeeman-effect ETAAS. Glow discharge mass spectrometry continues to be used for the analysis of semiconductors. Descriptions of a new discharge cell that can accommodate flat samples such as silicon wafers have now been published (93/C342,93/2 101 93/2226). It was claimed that this new design improved sensitivity as a result of increased silicon ion yield and detection limits as low as a few parts per trillion have been reported.The application of surface analysis techniques to the characterization of materials for the electronics industry has been the subject of various reviews. These include SIMS (92/4382 9214453 921446 1 92/4550) ion beam spectros- copies (921447 1) and electron and atomic force microscopy (93/2306). Several articles were published which summar- ize the development of sputtered neutral mass spectrometry and allied techniques (93/92/4478 9214522 9312464 93/229 1). However the majority of papers published on the analysis of silicon-based materials involve the use of secondary ion mass spectrometry. The accuracy of SIMS remains a subject of concern owing to the reliance on relative sensitivity factors. The basic requirements for quantitative SIMS analysis using caesium ion bombard- ment have been proposed (9312521). It was suggested that matrix effects observed arose from material dependent differences in sputtering yield and the diffusional transport of caesium to the bombardment surface.Close agreement was achieved in the Sics+ ion yields observed for silicon and silicon dioxide under conditions which minimized the build-up of caesium concentration at the sample surface. At an impact angle of greater than 60 degrees matrix depen- dent caesium coverage and the associated SIMS matrix effect were found to be small. Elemental sensitivities for 16 elements were obtained and in a comparison of the extreme case (in terms of high and low yield MCs+ ions) of A1 or ZnJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL.8 369R and As the difference in MCs+ yield ratio was about 30- fold. Factors affecting the quantification of C and 0 in silicon by SIMS have been studied (93/2972). The influence of primary ion beam current and primary ion beam sweep area on the determination of these analytes in silicon single crystals were investigated. It was found that a high primary ion beam current density was suitable for detection of 0 but medium density was recommended for the quantitative measurement of C in order to avoid high background intensities. The quantification of impurities or dopant species in the near surface region of semiconductor material by SIMS can be complicated by surface yield transients (93/2461). Such ion yield transients arise mainly from the implantation of the ion yield enhancing primary ion beam and can influence not only accuracy but also distort the shape of dopant profiles.The use of polyencapsulation oxygen flooding and low energy ion bombardment were evaluated as methods for the reduction of surface ion yield transients. It was reported that the use of low primary ion beam energies offered the additional benefit of reduced profile broadening as a result of cascade mixing. The internal indicator method was used to overcome matrix effects in the determination of As in silicon and silicon oxide interfaces (93/2577). Whilst such effects were further complicated by ion- and electron-enhanced segregation the proposed method was demonstrated to be a feasible if not comprehensive solution to the problem.Arsenic was found to be enhanced in the silicon phase by a factor of 4000. The determination of H in amorphous thin film silicon speci- mens using SIMS has been described (9312525). It was found that intensities from HCs+ ions produced under caesium primary ion bombardment correlated with H content in the hydrogenated thin films allowing the development of a quantitative method. A depth resolution of about 10 nm was obtained and using a focused beam lateral resolution of about 5 pm was achievable. A detection limit of 1019 H atoms cm-* was reported for a sputter erosion rate of about 1 nm s-l. The shape of secondary ion mass spectrometry depth profiles of B Ge and Sb in silicon have been studied (93/2460). These impurities were present in epitaxial layers grown by molecular beam epitaxy.The use of the data for the assessment of depth resolution and the implications for profile deconvolution were discussed. The depth distribu- tion of ion beam implanted gallium in crystalline silicon has been measured using SIMS (93/2459). The fabricated materials were examined using a 2 keV caesium ion bombardment at 60 degrees to normal with positive ion monitoring. It was established that implant ranges mea- sured correlated well with data derived from calculations but were shallower by 20-25 A. The segregation of Cu in silicon under oxygen ion beam bombardment has been studied by SIMS (93/2523). Changes in the decay length of the Cu signal were measured as a function of primary beam energy and angle of incidence.A strong dependence on incident angle was found and this was interpreted in terms of the nature of the altered layer formed under bombard- ment. Oxygen defects in Czochralski silicon have been examined by 3-dimensional SIMS using a camera-based imaging system (93/2382). Different manufacturing pro- cesses which gave rise to variations in the size and distribution of oxygen precipitates were monitored by the imaging procedure as well as by conventional depth profiling. Emphasis was laid on the characterization of the behaviour of the precipitate in the context of different annealing processes. Other applications of SIMS to the study of implantation processes and depth projling which may be of specific interest are the investigation of axial channelling of B in silicon (93/2383) diffusion of F in silicon and polysilicon (93/854) and concentration profiles of N in silicon implanted during thermocycling (92/4460).Silicon-germanium structures are of interest to the electronics industry because of potential for increased speed bandgap engineering rapid oxide growth and low processing temperatures for device applications (9312573). Epitaxial silicon-germanium thin films have been devel- oped using molecular beam epitaxy and chemical vapour deposition reactor systems (93/2363 93/25 13 93/2573). Rutherford backscattering spectrometry Auger electron spectrometry SIMS and transmission electron microscopy were used to study the As-deposited and oxidized films. The measurements detailed in the abstract included the deter- mination of Ge content and distribution and dopant concentrations within the film; the build-up of Ge at oxide interfaces and of oxygen at interlayer interfaces; and film thickness.It was noted that excellent agreement could be obtained using the various analytical techniques when appropriate calibration standards were used to determine Auger and SIMS sensitivity factors and sputter rates (93/2363). A silicon-germanium multilayer structure has been studied using a high-resolution depth profiling tech- nique (93/2456). Molecular oxygen ion beam etching was used in combination with imaging X-ray photo-electron spectrometry in order to examine the surface chemistry of the material under the conditions obtaining in SIMS characterization. The advantages and disadvantages of this approach were explored in the study of Si/Si(0.75)Ge(0.25) structures.The process of depositing a metal as a sputtered film on a semiconductor material is often referred to as metalization. Depth profiling of aluminium metalization of silicon by Auger or SIMS is impeded by severe sputter-induced roughening which causes a serious loss in depth resolution (9312570). A study was made of the effect of optimization of bombardment angle sample rotation during sputtering and the use of heavy or reactive ions. It was found that by using molecular oxygen ions instead of argon and employ- ing sample rotation sample depth resolution was improved by a factor of 10 compared with that obtained using routine operational parameters. In a separate SIMS investigation it was found that in addition to improving depth resolution sample rotation prevented bombardment-induced topogra- phical formation (93/2574).Rotation of the sample did not significantly affect the implant shape but did result in better characterization of the interface layer. Using molecu- lar oxygen ion bombardment silicon sputtered at twice the rate of aluminium under the conditions used. The use of sample rotation allowed the correct sputtering rate to be applied to the layer and substrate and thereby provide a much more accurate depth scale than could be established without rotation. Thus B was detected below 1 ppm using sample rotation and B at the aluminium/silicon interface was clearly defined. Depth projling of A1 thin j l m s on silicon substrates was also carried out using SIMS (93/2499).In the latter case profiling was performed using oxygen in the ion beam source or in the analytical chamber. The experimental results were compared with data ob- tained by dynamic Monte Carlo simulation. 3.2.2. Gallium arsenide-based materials As in the case of silicon-base semiconductor materials the application of SIMS continues to dominate the characteri- zation of gallium arsenide and related materials. A detailed compilation of SIMS ion yields of electronically important impurities in gallium arsenide and associated materials has been published (92/4439). The ionization efficiencies for 16 elements in gallium arsenide were measured. Highly doped crystals analysed by wet chemical methods and ion im- planted samples were examined as reference materials.The ion yields were used to study matrix effects in order to provide corrections to allow quantiJication by SIMS. The370R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 problem of achieving accurate quantification of impurities in the SIMS analysis of gallium arsenide has been examined at a fundamental level (93/1279). The influence of the operating parameters of a quadrupole SIMS instrument including secondary ion optics electron multiplier and target potential on performance were studied. The effect of oxygen flooding on secondary ion yield and SIN were also investigated. A fast xenon atom bombardment source and a photographic detection MS (resolution 5000) were em- ployed to obtain secondary ion mass spectra of a range of materials including gallium arsenide (93/26 12).Detection limits for the technique which was applied quantitatively for 27 elements ranged between 1010-1013 atoms cm-2. Surface contaminations on gallium arsenide wafers were analysed by time-of-flight SIMS and temperature depen- dent and angle resolved X-ray photoelectron spectrometry (93/2962). The dependence of the composition chemical state and diffusion behaviour of the passivating thermal oxide on different annealing temperatures was studied. No metal impurities were found within the sensitivity of the time-of-flight SIMS method at ambient or elevated temper- atures. A quantitative SIMS method for the determination of the composition of aluminium gallium arsenide and dopant Mg concentration has been published (93/22 16).Caesium cluster ions formed by collision with the matrix atoms were measured in positive ion mode. The ratio of AlCs+ ion intensity to that of an AsCs+ ion increased linearly and the relative sensitivity factor of a MgCs+ ion to an AsCs+ ion showed a constant value in relation to a reciprocal change in A1 and Ga content in the structure. The method was proven to be accurate for Al As Ga and dopant Mg in an unknown sample. The incorporation of Be in gallium arsenide-aluminium gallium arsenide heterostructures has been examined by SIMS (93/2961). Depth profiling of layers grown by molecular beam epitaxy indicated that the gallium arsenide material was doped with Be at a level of 2 x 1019 atoms cm-2 and that negligible Be diffusion occurred under the growth conditions used.Resonance ionization mass spectrometry has also been used for quantitative depth profiling of Be-doped gallium arsenide- aluminium gallium arsenide heterojunction bipolar transis- tors (93/2465). It was claimed that the technique allowed the elucidation of dopant migration as a result of freedom from matrix effects commonly found in SIMS. The magni- tude of dopant (Be) and matrix (Al) signals were related in proportion to concentration and quantification was pos- sible without extensive use of standards. Only a few abstracts were received concerning the use of AAS or AES for the analysis of gallium arsenide and related materials. An atomic absorption method was developed for layer by layer detection of impurities such as In and Sb in films of cadmium telluride on a gallium arsenide substrate (9214507).Layers were removed by etching with 2.5% bromine in hydrobromic acid. Impurities were detected by ETAAS with Zeeman-effect background correction. Detec- tion limits for In and Sb were reported to be 1.3 x 1 01* and 1.2 x lo1’ atoms ~ m - ~ respectively when the thickness of the layer removed was 0.3 pm. The electrical properties of gallium arsenide are to some extent dependent on the quality of the arsine used in the chemical vapour deposition process. The direct analysis of arsine requires specialized handling techniques for reasons of toxicity and safety and is hindered by a lack of suitable gaseous standards (93/2047). A static plasma was developed for handling toxic and reactive gases in which the plasma gas and sample were enclosed inside a quartz container.An additive gas was added to the argon discharge and after stabilization the sample was added. The container was then sealed to isolate the discharge. The selection of additive gas flow rate discharge container geometry and instrumental parameters were discussed. The qualitative determination of C Fe Ge Mg Mo Sn and V in arsine was reported. The analysis of high-purity gallium by high-resolution EDMS has been described (9312893). A special technique for the prepara- tion of gallium samples involved cryocooling of the liquid metal. The surface of the solid gallium sample prepared in this way was found to be essentially free of surface contamination. It was reported that the determination of over 70 impurity elements in gallium was possible in a single analytical measurement.Detection limits were nomi- nally better than a few ppb on a mass basis with accuracies within 40%. It was noted that detection limits for C Cl H 0 N and Ta were at the ppm level and were limited by contamination. 3.2.3. Cadmium mercury telluride and indium phosphide based materials A variety of techniques have been used to examine thin films and epitaxial layers of cadmium mercury telluride. A method was developed for the determination of the composition of cadmium mercury telluride epilayers using negative ion SIMS (93/2327 93/2467). A caesium primary ion beam was employed and it was reported that the Te secondary ion yield correlated linearly with the Cd mole fraction.Consequently it was possible to achieve quantifi- cation based on variations of the matrix-induced ion yield for Te. The method was applied to the characterization of chemical vapour deposition grown heterostructures. In another study of this type of process EDXRF was used to determine stoichiometry and thickness of epitaxial layers of cadmium mercury telluride being developed for infrared optoelectronic devices (9311 687). It was noted that whilst PIXE could be used to determine stoichiometry over a wafer the cost of accelerator time and beam damage made it unsuitable as a technique for production control. Conse- quently an EDXRF using americium as the excitation source was developed. It was reported that after correction for secondary fluorescence effects the EDXRF technique gave results indistinguishable from those obtained using PIXE.Electron microprobe microanalysis has been used to study the chemical states of atoms in cadmium mercury telluride via X-ray emission spectroscopy (92/4583). A chemometric approach was used to reveal the effects of weak chemical interactions. Depth profiling of In doping of epitaxial layers of cadmium mercury telluride was carried out in another study using SIMS and at higher concentra- tions photon induced X-ray emission spectrometry (93/3 107). The quantification of bulk impurity levels in the material was carried out by ETAAS. The sample (0.5 g) was dissolved in a hydrochloric-nitric acid mixture and diluted 25-fold. L‘vov platform atomization was used for the detection of Ag and Cu at 328.1 and 324.8 nm respectively.Indium was determined separately using tube wall atomiza- tion. Details of a new sampling technique for ETAAS based on sputtering have now been published (93/1640 see also J. Anal. At. Spectrom. 1992 7 381R). The technique was applied to the determination of In in cadmium telluride monocrystals. The material was sputtered onto a L’vov platform which was then introduced into the graphite furnace tube where the sample was atomized without further thermal pre-treatment. The content of In dopant was reported as 573 ppm for the sputter method compared with 400 ppm as determined by a dissolution pre-treatment followed by flame AAS. It was noted that whilst the method could be applied to other materials calibration of response remained the main problem.Finally laser enhanced ioniza- tion has been applied to the determination of In in cadmium mercury telluride and Cu in germanium (92/4623). A rod-in-flame atomizer was used to examine solid samples of the material directly. It was observedJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY. DECEMBER 1993 VOL. 8 371R that this approach resulted in a decrease in the matrix background signal of more than two orders of magnitude enabling detection limits in the sub-ppb range to be achieved. An XRF method has been proposed for the determination of indium in thermoelectronic material (93/2725). A small area on the natural cleavage face of a layered single crystal of bismuth indium selenide was examined non-destruc- tively using a wavelength dispersive instrument. A screen- ing mask of phosphor bronze was used to define a 2 x 12 mm region of the crystal which was fixed to the rear of the mask with adhesive tape.Net X-ray intensities were used for calibration and validated by extraction-photometric analysis of crystals after exposure. The concentration and distribution of impurity species in bismuth tellurium selenide thermoelectric semiconductors has been studied by SIMS (93/2367). Bromine-doped samples were made by hot pressing and it was found that alkali and oxide impurities were located preferentially in regions between grains or along grain boundaries. In a further related study SIMS was employed to examine Br and 0 ion intensities as a function of parameters used in the hot press preparation (93/2368).A strong correlation between hot press condi- tions and Br ion concentration was identified. The application of SIMS to the analysis of indium phosphide and related semiconductor materials was the subject of a recent review (9312500). An increase in the sensitivity of SIMS analysis of indium phosphide was reported for a method involving the detection of cluster molecular ions under caesium bombardment. It was found that with a low mass resolving power virtually all elements studied (Al Cu Ge Pb Sb Sn Ti and Zn) could be detected with detection limits of the order of atoms cm-* or better. The exceptions to this were Mg and S which were subject to interference by residual vacuum contaminants. Spatially resolved SIMS was used to study striations in doped indium phosphide wafers (93/2475).Line profiles of Fe Ga and Sb present in the material as dopants were found to be related to striation patterns. A paper concerning the surface concentrations of In 0 and P in indium phosphide single crystals after exposure to Gamble solution may also be of interest (93/2890). 3.3. Glasses Ceramics and Refractories 3.3.1. Glasses Relatively few novel methods were reported in the year under review concerning the analysis ofglasses. A review of AAS methodology by workers from Corning may be of interest (93/630). The main development in terms of technique was the use of direct laser sampling of solid glasses. Moenke-Blankenburg et al. (92/4628) published a paper on the quantitative analysis of glass using two laser sampling devices in conjunction with ICP-AES and ICP- MS.Analytical results for three fluorophosphate glasses obtained by five methods including conventional dissolu- tion procedures were compared. It was concluded that the laser based solid sampling offered the means of obtaining rapid quantitative multi-element analysis. The use of LA- ICP-MS for semiquantitative analysis of glasses has been described (931C1324). In this work NIST glass SRM 612 Glass Trace Elements was analysed quantitatively by dissolution followed by ICP-AES and by direct solid sampling using LA-ICP-MS. It was reported that the semiquantitative results obtained by LA-ICP-MS were found to be in good agreement with the certified data. The advantages of using a Q-switched Nd:YAG laserprobe for ICP-MS for the analysis of glasses has been discussed (93/C3014). It was observed that LODs of 30 ppb could be achieved using material from sample crater sites of the order of 30 pm in diameter.High magnification video viewing was claimed to allow the identification of samples as small as 1 pm for analysis. In a separate study LA-ICP-MS was applied to the semiquantitative bulk analysis of NIST SRM 612 Glass Trace Elements (93/2097). Analytes were detected in the sample in the range 10-80 ,ug g-l. The performance of LA-ICP-MS has been compared with GDMS for the analysis of glasses (93K1335). In order to sustain the d.c. GD during the sputtering of insulating material such as glass a conducting cathode made of tantalum was placed close to the sample. The metal from the cathode sputtered onto the glass causing re-sputtering of the sample into the argon discharge.It was observed that both the LA and GD techniques were able to determine elements at ppm levels with better than 5% relative precision. The surface chemistry of glasses is important in many industrial applications. A time-of-flight SIMS study of the incorporation of aluminium into the silane coating on E- glass fibres has been published (93/2271). It was confirmed that A1 from the glass surface was integrated with the silane coating of the coupling agent. The determination of surface silanol groups on silicate glasses has been carried out using static SIMS (9312650). This was achieved using detection of SOH+ cluster fragment ions. Absolute detection was achieved using calibration reference standards of quartz.The technique developed was applied to the analysis of soda-lime glass and silica films. A summary of other applications involving the analysis of glasses is provided in Table 3. 3.3.2. Ceramics and refractories Industrial interest in the properties and applications of advanced ceramic materials has led to a requirement for suitable analytical techniques for analysis and characteriza- tion. Specific reviews of the applications of LMMS (93/2290) and SIMS (92/4501) in this field have been published as has a more general overview of a range of analytical techniques (93/ 1670). The development of methods for the analysis of non- oxide ceramics such as refractory carbides and nitrides has continued in the past year. Non-oxide materials are difficult to dissolve and a number of wet chemical sample prepara- tion regimes for the analysis of silicon carbide (93/758 93/759) boron carbide (93/2994) silicon nitride (93/830 93/1280) aluminium nitride (93/1255) and zirconium ni- tride (93/566) have been published (see also Table 3).Most dissolution procedures are time consuming and progress continues to be made in the application of more direct methods such as slurry sampling (see also J. Anal. At. Spectrom. 1992 7 384R). This approach remains most popular when used in combination with direct nebulization of the slurry into an ICP and seems to be successful in application to the analysis of silicon nitride (921C4225 93/565) and silicon carbide (93/C376 93/529 93/758 931335 1). However viable methods based on the introduc- tion of silicon carbide slurries into an electrothermal atomizer prior to direct analysis by AAS have also been published (92/4568 93/758). Difficulty in the atomization of refractory materials remains a problem for the determi- nation of some elements particularly if present at high concentration. In a number of instances NAA has been used as a comparative technique for validation purposes or to extend the range of elements analysed (9214568 93/759 931830 93/3 144).Slurry sample introduction was combined with ETV for the introduction of silicon carbide samples into an ICP for AE detection (93/3124). In order to avoid difficulties associated with incomplete atomization from the graphite furnace used vaporization was carried out at 2100 "C in a stream of argon containing carbon tetrachlo- ride.The ratios of peak intensities for 12 elements in the presence and absence of carbon tetrachloride were in the372R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 range 1 - 1 500. Background equivalent concentrations were improved by a factor of 2-20 for these elements in comparison with a conventional dissolution approach. Complete vaporization of all components was achieved for a 1 mg sample but it was noted that minor components could be completely evaporated from samples up to 10 mg in mass. A similar approach was adopted for the determina- tion of trace elements in aluminium nitride by direct sample insertion (93/3 197). Solid samples were introduced into the ICP in a graphite cup and for refractory or carbide forming elements in-plasma halogenation was effected by passing carrier gas through freon 113.Detection limits at the ppm level were reported. The application of glow discharge techniques to the analysis of ceramics continues to be the subject of discus- sion. Analysis of ceramic materials has been achieved using microwave-boosted GD-AES (93/C 1480) and r.f. GDMS (93/1480). The use of auxiliary boosting of the discharge avoids the requirement for the sample to be conducting and opens up the possibility of achieving depth p r o j h g . Thus an r.f. GD source was utilized in the analysis of silicon nitride alumina and zirconia by AES and MS (93/59 1). X- ray fluorescence can be used to examine non-conducting samples directly and applications to the characterization of silicon nitride (93/ 1723) and refractory carbides borides and nitrides (92/4540) may also be of interest.Lead zirconate-titanate electroceramics are advanced materials with a perovskite-type structure. The stoichiome- try of these materials at the macroconstituent level affects a wide range of their functional properties. Transition metals are used as dopants in such materials to achieve suitable ferroelectric or piezoelectric properties. Several analytical methods have been developed and compared for the determination of dopant and impurity concentrations in lead zirconate-titanate by sample decomposition and ICP- AES (92/4416 9312053 93/2668). These involved acid decompositions under pressure; decomposition with am- monium sulfate and sulfuric acid; fusion with lithium borate; and fusion with sodium borate and sodium carbo- nate. It was noted that the presence of decomposition reagents in the sample presented to the ICP resulted in a significant decrease in analyte intensity.Matrix-matched standard solutions were used for calibration. Good agree- ment between dissolution and fusion methods was re- ported. These sample preparation methods were also found to be suitable for the determination of macroconstituents in lead zirconate-titanate including gadolinium- and lan- thanum-modified forms and other advanced ceramic ma- terials including barium titanate- and calcia-stablized zir- conia (931'2052). The determination of trace impurity elements in zircon- ium dioxide is problematic because of the resistance of the material to chemical attack.Four independent procedures for the determination of up to ten metals by ICP-AES have been described (93/744). These included fusion with am- monium hydrogensulfate; separation of zirconium by ex- traction from nitric acid with 2-thenoyltrifluoroacetone in xylene; matrix separation by precipitation as zirconium oxychloride from a hydrochloric acid-acetone medium; and slurry sample introduction utilizing ultrasonic disper- sion of the powder in hydrochloric acid. It was reported that matrix matching was not required in any case and calibra- tion was achieved by use of the standard additions procedure. The results obtained for all procedures were found to agree for Al Ca Fe Mg Na Ti and Y. Good agreement was also obtained for the separation methods for Cu Mn and V but the concentrations of these metals obtained by the method without matrix separation were considerably higher.The application of ICP-MS to the determination of REEs in zirconium oxide has been reported (93/2408). Samples were pressure digested in PTFE vessels with sulfuric acid. It was reported that three types of zirconium dioxide powder could be identified from the impurity contents of REEs at 200 ppm and those present at less than 10 ppm. An XRF method has been described for the determination of zirconium dioxide in mineral raw material and processing products (93/1765). Samples were fused in a mixture (1 :4 1) of lithium tetrabo- rate lithium metaborate and silica in a glassy carbon crucible. It was noted that the accuracy and productivity of the procedure could be improved if the fusion was per- formed at 850-880 "C with the application of ultrasound for 2-4 min.Methods for the analysis of mineral zircon by solution and LA-ICP-MS may also be of interest (93/1004 93/ 1054). A pressure acid decomposition procedure has been developed for the determination of trace impurities in sintered zirconia and alumina by ICP-AES (93/2 192). There were few abstracts of interest received pertaining to the analysis of alumina perhaps indicating that adequate methodology is now established in such applications. The analysis of lithium aluminate ceramics has received some attention. A slurry method has been developed for the determination of A1 and Li in such materials (93/C3001).The sample was ground to a particle size of less than 10 pm and introduced into the ICP in an aqueous suspension. Recoveries of the analytes were greater than 95% and the method could be carried out in less than 30 min. In a related study the direct analysis of discrete spherical particles of lithium aluminate weighing less than 1 mg each was achieved using ETV into the flame of an AAS instrument or into an ICP (93lC3003). The particles were analysed individually by sealing them in a small cavity between two porous graphite rods which were then heated rapidly to 3000 "C. The vaporized sample was swept in an argon carrier stream to the detector. Quantification was achieved for Li and trace elements using standard solutions or other reference materials. Abstracts continue to be received concerning the prob- lems of determining rare earth elements in their oxide matrices by ICP-AES.A summary of such methods is provided in Table 3 (see also J. Anal. At. Spectrorn. 1992,7 382R). Methods based on mass spectrometry offer a greater degree of spectral selectivity in addition to providing high sensitivity for REEs (93/2362). The capabilities of a range of techniques including ICP-MS SSMS SIMS laser de- sorption MS and TIMS for the study of REE compounds was reviewed. It was noted that several of the techniques were able to provide localized structural information in addition to surface and bulk quantification. This was illustrated in a publication concerning the application of laser ablation ICP-MS to the analysis of cerium oxide ceramics (93lC2225).The instrument was used to provide both bulk and feature analysis of the sample including discrete analysis of inclusions less than 50 pm in diameter. The performance of the system for the determination of oxygen was also discussed. The interference of rare earth oxides on the determination of trace impurities by ICP-MS can cause difficulties in quantification (93/C13 12). The use of electrothermal vaporization as a means of sample introduction for ICP-MS was shown to provide reductions in the level of spectral interferences observed in the determination of 14 REEs in a gadolinium oxide matrix. This was attributed to the prevention of oxide formation arising from solvent molecule interactions. Detection limits for 12 REEs using this procedure were one order of magnitude better than the equivalent data for conventional nebulization.The ETV-ICP-MS approach enabled the determination of Lu and Yb at the level of 100 ppb in solid samples although it was noted that a residual oxide interference remained. This problem was overcome by theJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 373R use of a high-resolution ICP-MS system (93lC1305). Trace element impurities in yttrium oxide and gadolinium oxide were determined using a mass resolution of 400. The specific spectral interferences caused by gadolinium oxide hydride and hydroxide ions on Lu Tb Tm and Yb were avoided by optimizing the instrument for the detection of doubly-charged ions. Detection limits obtained in this mode were in the range 0.05-3 ng 1-l.If singly-charged ions were used for measurement LODs in solution were reported to be in the range 5-30 pg 1-I. Finally the characterization of novel superconducting ceramics remains a subject of interest. Relatively routine methods for bulk analysis involving wet digestion and ICP- AES continue to be published and a summary of these is provided in Table 3. The determination of the component composition of Y-Ba-Cu-0 superconductors has been carried out by SIMS using an argon ion beam source (92/4683). The technique was also used for component profiling of single crystals and thin films. The morphology and lateral homogeneity of superconducting Y-Ba-Cu-0 films was the subject of another SIMS study (93/2516). High-resolution glow discharge mass spectrometry has been applied to the analysis of high-temperature superconductors (9312360).Pin samples of Y-Ba-Cu-0 material were examined while being maintained at temperatures near liquid nitrogen levels by cell cryocooling. It was claimed that the matrix independence of the technique obviated the need for reference standard materials. Applications of AES for the study by LA of superconducting materials may also be of interest (9311 948 9313285). LOCATION OF REFERENCES The full list of references cited in this Update have been published as follows 9214074-9214734 J. Anal. At. Spectrom. 1992 7(8) 389R-4 1 1 R. 93lCl-93lC997 J. Anal. At. Spectrom. 1993 8( I) 45R-78R. 931998-93lCl354 J. Anal. At. Spectrom. 1993 8(3) 137R-149R. 93lC1355-9312093 J. Anal. At. Spectrom.1993 8(4) 169R-194R. 9312094-92127 10 J. Anal. At. Spectrom. 1993 8(5) 239R-262R. 931271 1-93/3353 J. Anal. At. Spectrom. 1993 8(7) 313R-336R. Abbreviated forms of the literature references quoted (excluding those to Conference Proceedings) are given on the following pages for the convenience of the readers. The full references names and addresses of the authors and details of the Conference presentations can be found in the appropriate issues of JAAS cited above. Abbreviated List of References Cited in Update 9214293. Bull. Chem. SOC. Ethiop 1990 4 13. 9214313. Chin. Chem. Lett. 1990 1 235. 9214323. Dokl. Bolg. Akad. Nauk. 1990 43(10) 57. 9214341. Ganguang Kexue Yu Kuang Huaxue 1991 9 71. 9214382. Int. Wiss. Kolloq. Tech. Hochsch. Ilmenau 1990 35 144. 9214416.Mater. Sci. Monogr. 1991 66C 1919. 9214417. Mater. Trans. JIM 199 1 32 480. 9214418. Mendeleev Commun. 199 1 75. 9214439. NTT R&D 1991 40 373. 9214452. Papier (Darmstadt) 199 1 45 285. 9214453. Period. Polytech. Chem. Eng. 1990 34 81. 9214459. Polym. Test. 1991 10 3 1. 9214460. Poverkhnost 199 1 6 1 5 1. 9214461. Pover- khnost 1991 8 5. 9214464. Prepr.-Am. Chem. SOC. Div. Pet. Chem. 1991,36 31 1.9214465. Prepr. Pap. Am. Chem. SOC. Div. Fuel Chem. 1991 36 1180. 9214471. Proc. Electrochem. SOC. 1991 91 342. 9214478. Prog. Surf Sci. 1991 36 35. 9214501. Seramikkusu 1991 26 520. 9214507. Sib. Khim. Zh. 1991 2 51. 9214522. Thin Solid Films 199 1 200,293.9214527. Trends Anal. Chem. 199 1 10,23.9214538. Vopr. Khim. Khim. Tekhnol. 1989,90,34. 9214540. X-sen Bunseki no Shinpo 199 1 22 1 13.9214550.Wiss. Beitr. Martin-Luther-Univ. Halle- Wittenberg 1990 22 11 1. 9214568. J. Anal. At. Spectrom. 1992 7 521. 9214572. J. Anal. At. Spectrom. 1992 7 545. 9214573. J. Anal. At. Spectrom. 1992 7 551. 9214575. J. Anal. At. Spectrom. 1992 7 565. 9214583. Analyst 1992 117 803. 9214590. Analyst 1992 117 571. 9214605. J. Anal. At. Spectrom. 1992 7 121. 9214606. J. Anal. At. Spectrom. 1992 7 127. 9214614. J. Anal. At. Spectrom. 1992,7 175. 9214623. J. Anal. At. Spectrom. 1992 7 225. 9214627. J. Anal. At. Spectrom. 1992 7 247. 9214628. J. Anal. At. Spectrom. 1992 7 251. 9214632. J. Anal. At. Spectrom. 1992,7,273.9214672. Lihua Jianyan Huaxue Fence 199 1 27 220. 9214683. Zavod. Lab. 1990 56(8) 52. 9214710. Anal. Chim. Acta 199 1,247 97.931407.Analyst 1992,117 963. 931434. Anal. Chim. Acta 1991 254 109. 931439. Anal. Chim. Acta 1992 258 55. 931496. Guangpuxue Yu Guangpu Fenxi 1991 11(5) 32. 931508. Guangpuxue Yu Guangpu Fenxi 199 1 11(6) 27. 931512. Guangpuxue Yu Guangpu Fenxi 1991 11(6) 57. 931514. Guangpuxue Yu Guangpu Fenxi 199 1 11(6) 65.931529. Spectrochim. Acta Part B 1992 47 155. 931530. Spectrochim. Acta Part B 1992 47 173. 931565. Anal. Sci. 1991 7 1249. 931566. Anal. Sci. 1991 7 1251. 931568. Anal. Sci. 1991 7 1263. 931574. Anal. Sci. 1991 7 1645. 931591. Anal. Sci. 1991 7 537. 931604. ACS Symp. Ser. 1992 479 (Elem. Spec$c Chromatogr. Detect. At. Emiss. Spectrosc.) 90.931605. ACS Symp. Ser. 1992 479 (Elem. SpeciJic Chromatogr. Detect. At. Emiss. Spectrosc.) 105. 931629. Anal. Spectrosc.Libr. 1991 5 (At. Absorpt. Spectrom.) 321. 931630. Anal. Spec- trosc. Libr. 1991 5 (At. Absorpt. Spectrom.) 341. 931633. Anal. Spectrosc. Libr. 199 1 5 (At. Absorpt. Spectrom.) 463. 931640. Pure Appl. Chem. 1992,64,2 13.931652. Yankuang Ceshi 1991 10 287. 931658. Lihua Jianyan Huaxue Fence 1991 27 273. 931685. Fenxi Hauxue 1991 19 1276.931689. Fenxi Huaxue 199 1,19 1333.931690. Fenxi Huaxue 199 1 19 1352. 931703. Fenxi Huaxue 1992 20 348.931716. Fenxi Ceshi Tongbao 199 1 10(4) 46.931723. Appl. Spectrosc. 1991 45 1706. 931744. Biomed. Res. Trace Elem. 199 1 2,85.931757. Fresenius’J. Anal. Chem. 1992 342 107. 931758. Fresenius’ J. Anal. Chem. 1992 342 1 13. 931759. Fresenius’J. Anal. Chem. 1992,342 1 18. 931779. Vysokochist. Veshchestva 199 1 6 186. 931783. Tetsu to Hagane 199 1 77 1868.931797. Zh. Anal. Khim. 1991 46 2325. 931806. Anal. Chem. 1992 64 283A.374R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 931830. J. Mater. Sci. 1992 27 123 1. 931842. Acta Chim. Hung. 199 1 128 869.931854. Microbeam Anal. 199 1,26 48 1.9311003. J. Anal. At. Spectrom. 1992 7 605.9311004. J. Anal. At. Spectrom. 1992 7 61 1. 9311009. J. Anal. At. Spectrom. 1992 7 641. 9311012. J. Anal. At. Spectrom. 1992 7 661. 9311019. J. Anal. At. Spectrom. 1992 7 707. 9311030. J. Anal. At. Spectrom. 1992 7 769. 9311039. Analyst 1992 117 1473. 9311054. Anal. Proc. 1992 29 287. 9311082. Spectrochim. Acta Part B 1992 47 993. 9311111. Biul. Lubel. Tow. Nauk. Mat.-Fiz.-Chem. 1985 27 15. 9311114. Bol. SOC. Quim. Peru 1991 57 81. 9311115.Bol. SOC. Quim. Peru 1991 57,93.9311131. Dokl Bulg. Akad. Nauk. 199 1,44,45.9311143. Ganguang Kexue Yu Kuang Huaxue 1991 9 233. 9311155. Hejishu 1991 14 490. 9311160. Huanjing Wuran Yu Fangzhi 1991 13(6) 34. 9311185. Lubr. Eng. 1992 48 227. 9311192. Mater. Sci. Eng. B 1992 B12 195. 9311207. Nord Pulp Pap. Res. J. 1991,6 47.9311233. Ropa Uhlie 1991,33,73. 9311250. Polym. Paint Colour J. 199 1 181 248. 9311254. Tetsu to Hagane 199 1,77 188 1.9311255. Tetsu to Hagane 199 1,77 1922. 9311279. Zhenkong Kexue Yu Jishu 199 1 11 12 1.9311280. Zhongguo Haiyang Yaowu 199 1 10 1 1. 9311282. Zhongguo Zaozhi 199 1 10(3) 52. 9311638. Spectrochim. Acta Part B 1992 47 1065. 9311640. Spectrochim. Acta Part B 1992 47 1097. 9311670. Bunseki 1992 4 295. 9311687. Nucl. Instrum. Methods Phys.Res. Sect. B 1992 69 361. 9311723. Springer Ser. Opt. Sci. 1992 67(X-Ray Microsc. 111) 341. 9311732. Comm. Eur. Communities [Rep.] EUR 1992 EUR 141 13 Prog. Anal. Chem. Iron Steel Ind. 561. 9311733. Proc. Electrochem. SOC. 1992 92 (Proc. Symp. Diagn. Tech. Semicond. Mater. Devices 199 I) 132. 9311752. J. Electro- chem. SOC. 1992 139 175 1. 9311765. USSR SU 1,696,942 (Cl. GOlN1/28) 07 Dec 1991 Appl. 4,809,990 12 Feb 1990. Otkrytiya Izobret. 199 1 45 1 7 1. 9311772. Report 199 1 CER1-TR-M-9 1/ 16; Order No. AD-A232 229 Gov. Rep. Announce. Index (US) 1991 91(15) Abstr. No. 140,707. 9311786. Report 1990 ETN-9 1-98484 Avail. NTIS. From Sci. Tech. Aerosp. Rep. 1991 29 Abstr. No. N91-16338. 9311802. Fresenius’J. Anal. Chem. 1992 342 586. 9311803. Anal. Div. 1991 25 (Edmonton Spring Symp. 1991) 263. 9311817. Pure Appl. Chem. 1992 64 497. 9311820. Adv. X-Ray Anal. 1991 34 313. 9311842. Proc. Annu. Meet. Air Waste Manag. Assoc. 1991 84 Paper 91/134.5. 9311844. Cimento Bul. 1991 28(293) 1. 9311864. Powder Technol. 1992,69,93.9311879. Fresenius’ J. Anal. Chem. 1992 342 191. 9311892. Hyomen Gijutsu 1991 42 1240. 9311910. Eur. Pat. Appl. EP 464,671 (Cl. GOlN23/223) 08 Jan 1992 JP Appl. 90/170,687 28 Jun 1990. 9311933. At. Spectrosc. 1992 13 123. 9311946. Appl. Spectrosc. 1992 46 894. 9311948. Appl. Spectrosc. 1992 46 1025. 9311981. Jpn. J. Appl. Phys. Part 2 1992,31 L1 1. 9311988. Adv. X-Ray Anal. 1991 34 71. 9311990. Oyo Butsuri 1991 60 1141. 9312008. Adv. X-Ray Anal. 1991 34 285. 9312017. Diffus. Defect Data Pt. B 1991 19 (Gettering Defect Eng. Semicond. Technol.) 109. 9312047. J. Anal. At. Spectrom. 1992 7 839. 9312053. J. Anal. At. Spectrom. 1992 7 877. 9312056. J. Anal. At. Spectrom. 1992 7 895. 9312060. J. Anal. At. Spectrom. 1992 7 923. 9312066. J. Anal. At. Spectrom. 1992 7 965. 9312067. J. Anal. At. Spectrom. 1992 7 971. 9312068. J. Anal. At. Spectrom. 1992 7 979. 9312070. J. Anal. At. Spectrom. 1992 7 993. 9312071. J. Anal. At. Spectrom. 1992,7 999. 9312074. J. Anal. At. Spectrom. 1992 7 1019. 9312080. J. Anal. At. Spectrom. 1992 7 1075. 9312083. J. Anal. At. Spectrom. 1992 7 1091. 9312092. J. Anal. At. Spectrom. 1992 7 1147. 9312097. Fresenius’ J. Anal. Chem. 1992 342 917. 9312100. Fresenius’ J. Anal. Chem. 1992 343 741. 9312101. Fresenius’ J. Anal. Chem. 1992 343 773. 9312122. Appl. Spectrosc. 199 1 45 156 1. 9312134. Anal. Chim. Acta 1992 259 295. 9312192. Bunseki Kagaku 1991,40 T183.9312193. Bunseki Kagaku 1991,40 T209. 9312216. Anal. Sci. 1991,7 447. 9312217. Anal. Sci. 1991 7 467. 9312226. Anal. Sci. 1991 7 1243. 9312244. Appl. Spectrosc. 1992 46 547. 9312271. Catal. Today 1992 12 375. 9312290. Ber. Forschungszent. Juelich 1992 Juel- 2628 42. 9312291. Biol. Cell 1992 74 43. 9312294. Biol. Cell 1992 74 127. 93/2306. Bunseki 1992 7 517. 9312310. Bunseki Kagaku 1991 40 875. 9312327. Appl. Phys. Lett. 1992 60 222. 9312334. ASTM Spec. Tech. Publ. 1991 1109 96. 9312360. Mater. Chem. Phys. 1992 31 23. 9312362. Mater. Chem. Phys. 1992 31 127. 9312363. Mater. Dev. Microelectron. Packag. Perform. Reliab. Proc. Electron. Mater. Process. Congr. 4th 199 1 127. 9312367. Mern. Natl. Def Acad. Math. Phys. Chem. Eng. 1990 30 51.9312368. Mern. Natl. Def Acad. Math. Phys. Chem. Eng. 1990 30 43. 9312372. Microbeam Anal. 1991 26 31. 9312382. Mikrochim. Acta 1992 107 149. 9312383. Mikrochim. Acta 1992 107 16 1. 9312402 Tetsu to Hagane 1991 77 1851. 9312408. JFCC Rev. 1991 3 3. 9312421. J. Catal. 1992 133 467. 9312451. J. Vac. Sci. Technol. A 1992 10 2737. 9312456. J. Vac. Sci. Technol. A 1992 10 2897. 9312459. J. Vac. Sci. Technol. B 1992 10,333.9312460. J. Vac. Sci. Technol. B 1992,10 336. 9312461. J. Vac. Sci. Technol. B 1992 10 342. 9312464. J. Vac. Sci. Technol. B 1992 10 380.9312465. J. Vac. Sci. Technol. B 1992 10 385. 9312467. J. Vac. Sci. Technol. B 1992 10 1633. 9312475. Semicond. Sci. Technol. 1992 7 150. 9312486. Spectroscopy (Eugene Oreg.) 1992 7(4) 44. 9312499. Sur- Sci. 1992 271 641. 9312500. Indium Phosphide Relat. Mater. Process. Tech- nol. Devices 1992 45. 93/2513. ISTFA ’91 Proc. Int. Symp. Test. Failure Anal. 1991 17 17. 9312516. Nucl. Instrum. Methods Phys. Res. Sect. B 1992 64 193. 9312521. Nucl. Instrum. Methods Phys. Res. Sect. B 1992 64 621. 9312523. Nucl. Instrum. Methods Phys. Res. Sect. B 1992 64 632. 9312525. Nucl. Instrum. Methods Phys. Res. Sect. B 1992 64 646. 9312570. Surf Interface Anal. 1992 18 52. 9312573. SUI$ Interface Anal. 1992 18 129. 9312574. Surf Interface Anal. 1992 18 147.9312577. Surf Interface Anal. 1992 18 539. 9312603. Wuli Huaxue Xuebao 1992 8 148. 9312612. Zh. Anal. Khim. 1991 46 981. 9312628. Rep. Res. Cent. Ion Beam Technol. Hosei Univ. Suppl. 1992 10,67.9312646. NATO ASI Ser. Ser. B 199 1 265 357. 9312650. Nippon Seramikkusu Kyokai Gakujutsu Ronbunshi 1992,100,1038.93l2668. Appl. Surf Sci. 199 1,50,202.9312670. Bol. SOC. Quim. Peru 199 1,57 150. 9312686. J. Lubr. Eng. 1990 46 173. 9312725. Analyst 1993 118 79. 9312726. Analyst 1993 118 85. 9312745. Fresenius’ J. Anal. Chem. 1992 343 765. 9312746. Conf Proc. Ital. Phys. SOC. 1990 25 875. 9312779. X-Ray Spectrom. 1992 21 149. 9312819. Resi- dues Effluents Process. Environ. Consid. Proc. Int. Symp. 1992 149. 9312822. Pharm. Ind. 1992 54 293. 9312841. Nondestr. Charact. Mater. IV (Proc. Int. Symp.) 4th 1990 (Pub. 1991) 307. 9312890. Anal. Chem. 1992 64 2929. 9312893. Anal. Chem. 1992,64 2958. 9312902. Anal. Lett. 1992 25 2 157. 9312904. Anal. Sci. Technol. 1990 3 2 15. 9312908. Anal. Sci. Technol. 1992 5 169. 9312915. Appl. Spectrosc. 1992,46 1498. 9312921. Bunseki Kagaku 1992 41 425. 9312961. J. Vac. Sci. Technol. A 1992 10 2843. 9312962. J. Vac. Sci. Technol. B 1992 10 1291. 9312972. Nippon Kinzoku Gakkaishi 1992 56 1 174. 9312988. Spectroscopy (Eugene Oreg.) 1992 7(7) 12 14 18. 9312989. Spectroscopy (Eugene Oreg.) 1992 7(9) 36. 9312993. Sutf Sci. A 1992 269 520. 9313107. Fresenius’J. Anal. Chem. 1992 343 756. 9313123. Mikrochim. Acta 1992 108 157. 9313124. Mikrochim. Acta 1992 107 345. 9313135. Lihua Jianyan Huaxue Fence 1992 28 280. 9313144. Anal. Chim. Acta 1992 264 345. 9313153. Appl. Spectrosc. 1992,46 1382.9313156. At. Spectrosc. 1992 13 208. 9313163. Spectrochim. Acta Part B 1992 47B 1353.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 375R 9313177. Atmos. Environ. Part A 1992 26 741. 93/3197. Bunseki Kagaku 1992 41,609.9313245. Fresenius’J. Anal. Chem. 1992 344 269. 9313252. Anal. Chim. Acta 1992 268 323. 9313272. Chem. Anal. (Warsaw) 1992 37 93. 9313285. Guangpuxue Yu Guangpu Fenxi 1992 12 57. 9313296. Khim. Tekhnol. Vody 1992 14 109. 9313309. J. Chromatogr. 1992 609 305. 9313317. Mikrochim. Acta 1992,108,285.9313327. Proc. Int. Symp. Lab. Autom. Rob. 1991 (Pub. 1992) 402. 9313338. Zeolites 1992 12 806. 9313351. Sprechsaal 1992 125 508.
ISSN:0267-9477
DOI:10.1039/JA993080337R
出版商:RSC
年代:1993
数据来源: RSC
|
9. |
Glossary of abbreviations |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 376-376
Preview
|
PDF (105KB)
|
|
摘要:
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 376R Glossary of Abbreviations Whenever suitable elements may be referred to by their chemical symbols and compounds by their formulae. The following abbreviations are used extensively in the Atomic Spectrometry Updates. a.c. AA AAS AE AES AF AFS AOAC APDC ASV BCR CCP CMP CRM cv cw d.c. DCP DDC DMF DNA ECD EDL EDTA EDXRF EIE EPMA ETA ETAAS ETV EXAFS FAAS FAB FAES FAFS FI FPD Fr FTMS GC GD GDL GDMS Ge( Li) HCL h.f. HG HPGe HPLC IAEA IBMK ICP ICP-MS ID alternating current atomic absorption atomic absorption spectrometry atomic emission atomic emission spectrometry atomic fluorescence atomic fluorescence spectrometry Association of Official Analytical Chemists ammonium pyrrolidinedithiocarbamate anodic-stripping voltammetry Community Bureau of Reference capacitively coupled plasma capacitively coupled microwave plasma certified reference material cold vapour continuous wave direct current d.c.plasma diethyldithiocarbamate N N-dimethylformamide deoxyribonucleic acid electron capture detection electrodeless discharge lamp ethylenediaminetetraacetic acid energy dispersive X-ray fluorescence easily ionizable element electron probe microanalysis electrothermal atomization electrothermal atomic absorption electrothermal vaporization extended X-ray absorption fine structure flame AAS fast atom bombardment flame AES flame AFS flow injection flame photometric detector Fourier transform Fourier transform mass spectrometry gas chromatography glow discharge glow discharge lamp glow discharge mass spectrometry lithium-drifted germanium hollow cathode lamp high frequency hydride generation high-purity germanium high-performance liquid chromatography International Atomic Energy Agency isobutyl methyl ketone (4-methylopentan-2- inductively coupled plasma inductively coupled plasma mass spectrometry isotope dilution (ammonium pyrrolidin-1-yl dithioformate) spectrometry spectroscopy one) IR IUPAC LA LC LEAFS LEI LMMS LOD LTE MECA MIP MS NAA NaDDC NIES NIST NTA OES PIGE PIXE PMT PPb PPm PTFE QC r.f.REE(s) RIMS RM RSD SIB SEC SEM SFC Si( Li) SIMAAC SIMS SIN SR SRM SSMS STPF TCA TIMS TLC TMAH TOP0 TXRF u.h.f. uv VDU vuv WDXRF XRF infrared International Union of Pure and Applied Chemistry Laser ablation liquid chromatography laser-excited atomic fluorescence laser-enhanced ionization laser-microprobe mass spectrometry limit of detection local thermal equilibrium molecular emission cavity analysis microwave-induced plasma mass spectrometry neutron activation analysis sodium diethyldithiocarbamate National Institute for Environmental National Institute of Standards and nitrilotriacetic acid optical emission spectrometry particle-induced gamma-ray emission particle-induced X-ray emission photomultiplier tube parts per billion parts per million polytetrafluoroethylene quality control radiofrequency rare earth element(s) resonance ionization mass spectrometry reference material relative standard deviation signal to background ratio size-exclusion chromatography scanning electron microscopy supercritical fluid chromatography lithium-drifted silicon simultaneous multi-element analysis with a continuum source secondary ion mass spectrometry signal to noise ratio synchrotron radiation Standard Reference Material spark source mass spectrometry stabilized temperature platform furnace trichloroacetic acid thermal ionization mass spectrometry thin-layer chromatography tetra methlammonium hydroxide trioctylphosphine oxide total reflection X-ray fluorescence ultra-high frequency ultraviolet visual display unit vacuum ultraviolet wavelength dispersive X-ray fluorescence X-ray fluorescence spectrometry Studies Technology
ISSN:0267-9477
DOI:10.1039/JA993080376R
出版商:RSC
年代:1993
数据来源: RSC
|
10. |
Atomic Spectrometry Update References |
|
Journal of Analytical Atomic Spectrometry,
Volume 8,
Issue 8,
1993,
Page 377-404
Preview
|
PDF (4423KB)
|
|
摘要:
377R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 ATOMIC SPECTROMETRY UPDATE REFERENCES The address given in a reference is that of the first named author and is not necessarily the same for any co-author. 9313354. 931 3 3 5 5. 9313356. 9313 3 5 7. 931 3 3 5 8. 931 3 3 5 9. 9313 360. 931336 1. 931 3362. 9313363. 9313364. 9313365. 9313366. 931 3 367. Clarke C. G. Adams M. J. Atomic emission analysis using a spatial interferometer Analyst 1993 118 229. (Sch. Appl. Sci. Univ. Wolverhampton Wulfruna St. Wolverhampton UK WVl 1 LY). Tsai S.-j. J. Bae-Y.4 Determination of trace concen- trations of arsenic in nickel-base alloys by electrother- mal atomic absorption spectrometry Analyst 1993 118 297. (Dept. Appl. Chem. Providence Univ. Taichung Hsien Taiwan). Tsai S.-j.J. Bae-Y.-l. Flame atomic absorption spec- trometric determination of magnesium in nickel-base alloys Analyst 1993 118 301. (Dept. Appl. Chem. Providence Univ. Taichung Hsien Taiwan). Wagatsuma K. Hirokawa K. Characterization of argon-helium mixed gas inductively coupled plasma based on spectroscopic analyses of the argon and zinc emission lines Anal. Sci. 1993,9 83. (Inst. Mater. Res. Tohoku Univ. Sendai Japan 980). Harada Y. Kurata N. Furuno G. Simultaneous determination of major constituents and impurities in high-purity mullite using pressure acid decomposition Anal. Sci. 1993 9 99. (Mech. Electron. Res. Inst. Fukuoka Ind. Technol. Cent. Kitakyushu Japan 807). Okamoto Y. Kakigi H. Kumamaru T. Determination of cadmium and lead by inductively coupled plasma atomic emission spectrometry with tungsten boat fur- nace vaporizer Anal.Sci. 1993 9 105. (Fac. Sci. Hiroshima Univ. Hagashi-Hiroshima Japan 732). Shibata Y. Yoshinaga J. Morita M. Micro-laser ablation system combined with inductively coupled plasma mass spectrometry for the determination of elemental composition in the micron range Anal. Sci. 1993 9 129. (Environ. Chem. Div. Natl. Inst. Environ. Stud. Tsukuba Japan 305). Pak Y. N. Tanaka T. Kawaguchi H. Crater shapes in glow discharge mass spectrometry with a Grimm-type ion source Anal. Sci. 1993 9 137. (Dept. Mater. Sci. Eng. Nagoya Univ. Nagoya Japan 464-01). Reimer R. A. Miyazaki A. Determination of nickel and vanadium in commercial gasolines and crude oil reference materials by inductively coupled plasma mass spectrometry with microemulsion sample introduction Anal.Sci. 1993 9 157. (Natl. Inst. Resour. Environ. Tsukuba Japan 305). Frigge C. Jackwerth E. Spectral interferences in the determination of traces of palladium in the presence of lead by atomic absorption spectroscopy Spectrochim. Acta Part B 1992 47 787. (Dept. Chem. Anal. Chem. Ruhr Univ. D-4630 Bochum 1 Germany). Tanner S. D. Space charge in ICP-MS calculation and implications Spectrochim. Acta Part B 1992 47 809. (SCIEX Thornhill Ontario Canada L3T 1 P2). Burton L. L. Horlick G. MS Interview an elemental mass spectrometry spectral interference data base Spec- trochim. Acta Part B 1992 47 E1621. (Dept. Chem. Univ. Alberta Edmonton Alberta Canada T6G 2G2). Liang Z.-w. hnardo R. F. Michel R. G. Determina- tion of tellurium and antimony in nickel alloys by laser excited atomic fluorescence spectrometry in a graphite furnace Spectrochim.Acta Part B 1993 48 7. (Dept. Chem. Univ. Connecticut Storrs CT 06269-3060 USA). Nickel H. Zadgorska Z. Wolff G. Optimization of electrothermal vaporization of impurity elements in ceramic powders using inductively coupled plasma 9313368. 9313369. 9313370. 931 337 1. 9313372. 931 33 7 3. 931 3374. 931337 5. 9 313 3 76. 9313377. 931 3 3 7 8. 931 3 3 7 9. atomic emission spectroscopy Spectrochim. Acta Part B 1993 48 25. (Inst. Reactor Mater. Res. Cent. Juelich 5 170 Juelich Germany). Milton D. M. P. Hutton R. C. Investigations into the suitability of using a secondary cathode to analyse glass using glow discharge mass spectrometry Spectrochim.Acta Part B 1993 48 39. (VG Elemental Winsford Cheshire UK CW7 3BX). Galban J. Marcos E. Lamana J. Castillo J. R. Evaluation of a method for arsenic(1rr) and antimony- (111) determination by vapour phase molecular absorp- tion spectrometry using graphite furnace volatilization Spectrochim. Acta Part B 1993,48 53. (Fac. Sci. Univ. Zaragoza Zaragoza 50009 Spain). Ulgen A. Dogan M. Gokmen A. Yalcin S. Back- ground suppression of argon lines in glow discharge atomic emission spectrometry by a lock-in amplifier and Kalman filter deconvolution Spectrochim. Acta Part B 1993 48 65. (Dept. Chem. Erciyes Univ. Kayseri 38039 Turkey). Fonseca R. W. McNally J. Holcombe J. A. Mecha- nisms of vaporization for silver and gold using electroth- ermal atomization Spectrochim.Acta Part B 1993 48 79. (Dept. Chem. Biochem. Univ. Texas Austin TX 787 12 USA). Azeredo L. C. Sturgeon R. E. Curtius A. J. Determi- nation of trace metals in sea-water by graphite furnace atomic absorption following on-line separation and preconcentration Spectrochim. Acta Part B 1993 48 91. (Inst. Environ. Chem. Natl. Res. Counc. Canada Ottawa Ontario Canada KIA OR9). Toelg G. Klockenkaemper R. Role of total reflection X-ray fluorescence in atomic spectroscopy Spectrochim. Acta Part B 1993,48 1 1 1. (Inst. Spektrochem. Angew. Spektrosk. W-4600 Dortmund I Germany). Sinner T. Hoffmann P. Ortner H. M. Determination of iron(r1) and iron(II1) in small samples by microbore ion chromatography and photometric atomic absorp- tion spectrometry and total-reflection X-ray fluores- cence detection Spectrochim. Acta Part B 1993 48 255.(Fachgeb. Chem. Anal. TH Darmstadt W-6 100 Darmstadt Germany). Goguel R. Group separation by solvent extraction from silicate rock matrix of niobium molybdenum tantalum and tungsten at low levels for ICP-MS Fresenius’ J. Anal. Chem. 1992,344 326. (Ind. Res. Lower Hutt N. Z.). Herion J. Does analytics produce facts? An interdisci- plinary approach Fresenius’ J. Anal. Chem. 1992 344 3 5 3. (Inst. Schicht-und Ionentech. Forschungszen t. Juelich GmbH. W-5 170 Juelich Germany). Bauer-Wolf E. Wegscheider W. Posch S. Knapp G. Kolmer H. Panholzer F. Determination of traces of rare earth elements in geological samples Tulantu 1993 40 9. (Inst. Anal. Chem. Micro-Radiochem. Graz Univ. Technol. A-8010 Graz Austria).Falcon M. Guitteras J. Izquierdo A. Prat M. D. Spectrofluorimetric determination of zinc in foods with 8-@-toluenesulfonamido)quinoline in micellar medium Talanta 1993 40 17. (Dept. Quim. Anal. Univ. Barcelona Barcelona 08028 Spain). Nyman J. Ivaska A Potentiometric and spectropho- tometric determination of calcium in the wet end of paper machines by flow injection analysis Talanta 1993 40 95. (Lab. Anal. Chem. Abo Akad. Univ. SF- 20500 Turku-Abo Finland).378R 9313380. 931338 1. 9313382. 9313383. 9313384. 9313385. 9313 3 86. 9313387. 9313388. 9313389. 9313390. 931339 1. 9313392. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Martinez-Avila R. Carbonell V. Salvador A. De la Guardia M. Direct FIA-AS determination of potassium and magnesium in cement samples by use of the slurries approach Talanta 1993 40 107.(Dept. Anal. Chem. Univ. Valencia Burjassot 46 100 Spain). Hayashibe Y. Takeya M. Sayama Y. Spectrophoto- metric determination of cobalt in high-salt concentra- tion solutions by flow injection method Bunseki Ka- gaku 1992 41 633. (Cent. Res. Inst. Mitsubishi Mater. Co. Omiya 330 Japan). Uwamino Y. Morikawa H. Tsuge A. Nakane K. Iida Y. Ishizuka T. Determination of trace impurities in sintered silicon carbide and silicon nitride by pres- sure acid decomposition-inductively coupled plasma atomic emission spectroscopy (ICP-AES) Bunseki Ka- guku 1992 41 T151. (Gov. Ind. Res. Inst. Nagoya Nagoya 462 Japan). Matsusaki K. Yamamoto T. Oishi T. Effect of metal nitrates as a matrix modifier for the determiation of tellurium by graphite furnace AAS Bunseki Kagaku 1993 42 1.(Fac. Eng. Yamaguchi Univ. Ube 755 Japan). Saito M. Analysis of trace elements by glow discharge mass spectrometry using a doped-electrode technique Bunseki Kagaku 1993 42 21. (Natl. Res. Inst. Met. Tokyo 153 Japan). Hill S. J. Ford M. J. Ebdon L. Investigations into the application of methane addition to the nebulizer gas in inductively coupled plasma mass spectrometry for the removal of polyatomic interferences J. Anal. At. Spec- from. 1992 7 1157. (Dept. Environ. Sci. Univ. Plymouth Plymouth Devon UK PL4 BAA). Goossens J. Dams R. Anion exchange for the elimina- tion of spectral interferences caused by chlorine and sulfur in inductively coupled plasma mass spectrometry J. Anal.At. Spectrom. 1992 7 1167. (Inst. Nucl. Sci. Univ. Gent B-9000 Ghent Belgium). Haraldsson C. Pollak M. Oehman P. Simultaneous determination of antimony arsenic and selenium in natural waters by means of hydride generation coupled to plasma source mass spectrometry J. Anal. At. Spectrom. 1992 7 1183. (Dept. Anal. Mar. Chem. Univ. Goeteborg S-4 12 96 Goeteborg Sweden). Anderson S. T. G. Robert R. V. D. Farrer Humphrey N. Determination of trace impurities in tantalum oxide and niobium oxide by laser ablation inductively coupled plasma mass spectrometry J. Anal. At. Spectrom. 1992 7 1 195. (Anal. Sci. Div. Mintek Randburg 2125 South Africa). Stroh A. Voellkopf U. Denoyer E. R. Analysis of samples containing large amounts of dissolved solids using microsampling flow injection inductively coupled plasma mass spectrometry J.Anal. At. Spectrom. 1992 1201. (Bodenseewerk Perkin-Elmer GmbH W-7770 Uberlingen Germany). Pan C.-k. Zhu G.-x. Browner R. F. Role of auxiliary gas flow in organic sample introduction with inductively coupled plasma atomic emission spectrometry J. Anal. At. Spectrom. 1992 7 1231. (Sch. Chem. Biochem. Georgia Inst. Technol. Atlanta GA 30332-0400 USA). Karanassios V. Usypchuck L. Moss P. Salin E. D. Flame sample introduction system for inductively coup- led plasma atomic emission spectrometry J. Anal. At. Spectrom. 1992 7 1243. (Dept. Chem. McGill Univ. Montreal Quebec Canada H3A 2K6). Wu M.-g. Carnahan J. W. Direct determination of aqueous carbon phosphorus and sulfur using a kilo- watt-plus helium microwave-induced plasma system with ultrasonic nebulization J.Anal. At. Spectrom. 1992 7 1249. (Dept. Chem. North. Illinois Univ. DeKalb IL 601 15 USA). 9313393. 9313394. 9313395. 9313396. 9313 397. 9313398. 9313399. 9313400. 931340 1. 9313402. 9313403. 9313404. Alvarado J. Wu M.-g. Carnahan J. W. Electrother- mal vaporization and ultrasonic nebulization for the determination of aqueous sulfur using a kilowatt-plus helium microwave-induced plasma J. Anal. At. Spec- from. 1992 7 1253. (Dept. Chem. North. Illinois Univ. DeKalb IL 601 15 USA). Welz B. Schlemmer G. Mudakavi J. R. Palladium nitrate-magnesium nitrate modifier for electrothermal atomic absorption spectrometry. Part 5. Performance for the determination of 21 elements J. Anal. At. Spectrom. 1992 7 1257. (Dept. Appl.Res. Boden- seewerk Perkin-Elmer GmbH W-7770 Uberlingen Germany). Benzo Z. Cecarelli C. Carrion N. Alvarez M. A Rojas C. ROSSO M. Analytical characteristics in electrothermal atomization studies of cadmium copper germanium molybdenum lead and vanadium from pyrolytic and tungsten-coated L'vov platforms by atomic absorption spectrometry J. Anal. At. Spectrom. 1992 7 1273. (Cent. Quim. Inst. Venez. Invest. Cient. Caracas 1020-A Venezuela). Almeida A. A. Bastos M. L. Cardoso M. I. Ferreira M. A. Lima J. L. F. C. Soares M. E. Determination of lead and aluminium in port wine by electrothermal atomization atomic absorption spectrometry J. Anal. At. Spectrom. 1992 7 1281. (Fac. Pharm. Univ. Porto Oporto 4000 Portugal). Lopez Garcia I. Arroyo Cortez J. Hernandez Cordoba M.On-line dilution system for extending the calibra- tion range of flame atomic absorption spectrometry J. Anal. At. Spectrom. 1992 7 1291. (Fac. Chem. Univ. Murcia Murcia 3007 1 Spain). Eisman M. Gallego M. Valcarcel M. Coupling of a continuous liquid-liquid extractor to a flame atomic absorption spectrometer for the determination of alka- loids J. Anal. At. Spectrom. 1992 7 1295. (Fac. Sci. Univ. Cordoba Cordoba 14004 Spain). Shuttler I. L. Feuerstein M. Schlemmer G. Long- term stability of a mixed palladium-iridium trapping reagent for in situ hydride trapping within a graphite electrochemical atomizer J. Anal. At. Spectrom. 1992 7 1299. (Bodenseewerk Perkin-Elmer GmbH W-7770 Uberlingen Germany). Marshall J. Carroll J. Crighton J. S. Barnard C. L. R. Atomic spectrometry update-industrial ana- lysis metals chemicals and advanced materials J.Anal. At. Spectrom. 1992 7 349R. (Wilton Res. Cent. ICI PLC Middlesbrough Cleveland UK TS6 8JE). Evans E. H. Giglio J. J. Interferences in inductively coupled plasma mass spectrometry. A review J. Anal. At. Spectrom. 1993 8 1. (Dept. Environ. Sci. Univ. Plymouth Plymouth UK PL4 8AA). Walder A. J. Platzner I. Freedman P. A. Isotope ratio measurement of lead neodymium and neodymium- samarium mixtures hafnium and hafnium-lutetium mixtures with a double focusing multiple collector inductively coupled plasma mass spectrometer J. Anal. At. Spectrom. 1993 8 19. (Fisons Instrum. Winsford Cheshire UK CW7 3BX). Williams J. G. Jarvis K. E. Preliminary assessment of laser ablation inductively coupled plasma mass spectro- metry for quantitative multi-element determination in silicates J.Anal. At. Spectrom. 1993 8 25. (Dept. Geol. R. Holloway Univ. London Egham Surrey UK TW20 OEX). Stroh A. Vollkopf U. Optimization and use of flow injection vapour generation inductively coupled plasma mass spectrometry for the determination of arsenic antimony and mercury in water and sea-water at ultratrace levels J. Anal. At. Spectrom. 1993.,. 8 35. (Bodenseewerk Perkin-Elmer GmbH W-7770 Uberlin- gen Germany).JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993. VOL. 8 379R 9313405. 9313406. 9313407. 9 31 3408. 9313409. 93/34 10. 93/34 1 1. 93/34 12. 93/34 13. 931341 4. 93/34 15. 931341 6. 9313417. Ohlsson K. E. Sturgeon R. E. Willie S. N. Van Luong T.Figures of merit for two-step furnace atomi- zation plasma emission spectrometry J. Anal. At. Spectrom. 1993 8 41. (Dept. Anal. Chem. Univ Umea S-901 87 Umea Sweden). Botto R. I. Applications of ultrasonic nebulization in the analysis of petroleum and petrochemicals by induc- tively coupled plasma atomic emission spectrometry J. Anal. At. Spectrom. 1993 8 51. (Exxon Res. Eng. Co. Baytown TX 77522-4255 USA). Ren J. M. Salin E. D. Evaluation of a modified electrothermal vaporization sample introduction system for the analysis of liquids by inductively coupled plasma atomic emission spectrometry J. Anal. At. Spectrom. 1993 8 59. (Dept. Chem. McGill Univ. Montreal Quebec Canada H3A 2K6). Corns W. T. Stockwell P. B. Ebdon L. Hill S. J. Development of an atomic fluorescence spectrometer for the hydride-forming elements J.Anal. At. Spec- from. 1993 8 71. (PS Anal. Ltd. Kent UK TN 15 6QY). Pakkanen T. A. Hillamo R. E. Maenhaut W. Simple nitric acid dissolution method for electrothermal atomic absorption spectrometric analysis of atmospheric aero- sol samples collected by a Berner-type low-pressure impactor J. Anal. At. Spectrom. 1993 8 79. (Air Qual. Dept. Finn. Meteorol. Inst. SF-008 10 Helsinki Fin- land). Tserovsky E. Arpadjan S. Karadjova I. Behaviour of cadmium cobalt and lead in chlorine-containing organic solvents in electrothermal atomic absorption spectrometry J. Anal. At. Spectrom. 1993 8 85. (Fac. Chem. Univ. Sofia 1126 Sofia Bulgaria). Sentimenti E. Mazzetto G. Milella E. Determination of impurities in germanium tetrachloride germanium dioxide and high-purity germanium by Zeeman-effect electrothermal atomic absorption spectrometry J.Anal. At. Spectrom. 1993 8 89. (Cent. Ric. Venezia Temav SPA 30175 Venezia Port0 Marghera Italy). Sen Gupta J. G. Determination of scandium yttrium and eight rare-earth elements in silicate rocks and six new geological reference materials by simultaneous multi-element electrothermal atomic absorption spec- trometry with Zeeman-effect background correction J. Anal. At. Spectrom. 1993 8 93. (Geol. Sum. Canada Ottawa Ontario Canada KIA OE8). Lopez Garcia I. Arroyo Cortez J. Hernandez Cordoba M. Rapid furnace programs for the slurry-electrother- ma1 atomic absorption spectrometric determination of chromium lead and copper in diatomaceous earth J. Anal.At. Spectrom. 1993 8 103. (Fac. Chem. Univ. Murcia Murcia 3007 1 Spain). Ruiz A. I. Canals A. Hernandis V. Effect of surfac- tants in flame atomic absorption spectrometry with pneumatic nebulization influence of hydrophobic chain length J. Anal. At. Spectrom. 1993,8 109. (Dept. Anal. Chem. Univ. Alicante Alicante 0307 1 Spain). Kojima I. Kondo S. Sensitive ‘one drop’ flame atomic absorptiometric determination of cadmium in botanical samples using direct nebulization of chloroform extract J. Anal. At. Spectrom. I993,8 1 15. (Dept. Appl. Chem. Nagoya Inst. Technol. Nagoya 466 Japan). Kumar S. J. Gangadharan S. Accurate determination of selenium in the presence of iron by deuterium arc electrothermal atomic absorption spectrometry J. Anal. At. Spectrom. 1993 8 127.(Anal. Chem. Div. Bhabha At. Res. Cent. Bombay 400085 India). Cresser M. S. Armstrong J. Cook J. Dean J. R. Watkins P. Cave M. Atomic spectrometry up- date-environmental analysis J. Anal. At. Spectrom. 1993,8 1R. (Dept. Plant Soil Sci. Aberdeen Univ. Old Aberdeen UK AB9 2UE). 931341 8. 93/34 19. 9313420. 931342 I . 9313422. 9313423. 9313424. 9313425. 9313426. 9313427. 931342 8. 9313429. 9313430. 931343 1. Yudelevich I. G. Zaksas B. I. Shaburova V. P. Cherevko A. S. Analysis of high-temperature supercon- ducting materials by atomic absorption and atomic emission methods At. Spectrosc. 1992 13 108. (Inst. Inorg. Chem. Novosibirsk 630090 Russia). Chartier A. Fox C. G. Georges J. Evaluation of thermal lens detection in flow injection with high background absorbance Analyst 1993 118 157.(Lab. Sci. Anal. Univ. Claude-Bernard-Lyon I F69622 Vil- leurbanne France). Nerin C. Zufiaurre R. Cacho J. Critical study of several procedures for digestion of fly ash for analysis of arsenic iron and manganese Analusis 1992 20 597. (CPSI Univ. Zaragoza Zaragoza 5001 5 Spain). McCaig L. Shi Z. Woodrum T. H. Brewer S. Sacks R. Sampling excitation and ionization characteristics of a planar magnetron glow discharge device Appl. Spectrosc. 1992 46 1762. (Dept. Chem. Univ. Michi- gan Ann Arbor MI USA). Yang J.-f. Piao Z.-x. Zeng X.-j. Evaluation of the effect of wavelength positioning errors on Kalman filtering results in inductively coupled plasma atomic emission spectrometry Appl. Spectrosc. 1992,46 18 16. (Changchun Inst. Appl. Chem. Chin. Acad.Sci. Changchun 130022 China). Zilliacus R. Likonen J. Aluminium determination using resonance ionization spectrometry Appl. Spec- trosc. 1992 46 1828. (Reactor Lab. Tech. Res. Cent. Finland SF-02 15 1 Espoo Finland). Wu M. Hieftje G. M. New spray chamber for inductively coupled plasma spectrometry Appl. Spec- trosc. 1992 46 1912. (Dept. Chem. Indiana Univ. Bloomington IN 47405 USA). Turner D. E. Fannin H. B. Simplex optimization program for the determination of temperatures in reduced-pressure ICPS Appl. Spectrosc. 1992,46 1929. (Dept. Chem. Murray State Univ. Murray KY 42071 USA). Fucsko J. Tan S. H. La H. Balazs M. Fluoride interference in the determination of boron by induc- tively coupled plasma emission spectroscopy Appl. Spectrosc. 1993 47 150. (Balazs Anal. Lab.Sunnyvale CA 94089 USA). Duckworth D. C. Barshick C. M. Bostick D. A. Smith D. H. Direct measurement of uranium isotopic ratios in soils by glow discharge mass spectrometry Appl. Spectrosc. 1993 47 243. (Anal. Chem. Div. Oak Ridge Natl. Lab. Oak Ridge TN 37831-6375 USA). Frigge Ch. Jackwerth E. Systematic investigation of multi-element preconcentration from copper alloys by carbamate precipitation before atomic absorption spec- trometric analysis Anal. Chim. Acta 1993 271 299. (Anal. Chem. Dept. Chem. Ruhr Univ. Bochum P.O. Box 102 148 D(W)-4630 Bochum Germany). Milella E. Sentimenti E. Mazzetto G. Meregalli L. Battagliarin M. Direct determination of trace elements in indium phosphide by atomic absorption spectro- metry Anal. Chim. Acta 1993,272,99.(CNRSM Cent. Naz. Ric. e Sviluppo Mater. via G. Marconi 147 72023 Mesagne Brindisi Italy). Lee M. L. Tolg G. Beinrohr E. Tschiipel P. Preconcentration of palladium platinum and rhodium by on-line sorbent extraction for graphite furnace atomic absorption spectrometry and inductively coup- led plasma atomic emission spectrometry Anal. Chim. Acta 1993 272 193. (Inst. Pektrochem. und Angew. Spektrosk. (ISAS) Dortmund Germany). Adriaens A. G. Kelly W. R. Adams F. C. Propagation of uncertainties in isotope dilution mass spectrometry using pulse counting detection Anal. Chem. 1993 65 660. (Dept. Chem. Univ. Antwerp B-2610 Wilrijk Belgium).380R 9313432. 9313433. 93/3434. 9 31343 5. 9313436. 9313437. 9313438. 9313439. 9313440. 931344 1. 9313442. 9313443. 9313444. 9313445.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Chakrabarti C. L. Gilmutdinov A. K. Hutton J. C. Digital imaging of atomization processes in electrother- mal atomizers for atomic absorption spectrometry Anal. Chem. 1993 65 716. (Cent. Anal. Environ. Chem. Carleton Univ. Ottawa Ontario Canada KIS 5B6). King F. L. Pan C. Temporal signal profiles of analytical species in modulated glow discharge plasmas Anal. Chem. 1993 65 735. (Dept. Chem. West Virginia Univ. Morgantown WV 26506-6045 USA). Guell 0. A. Holcombe J. A. Rademeyer C. J. Effect on electrothermal atomization signals of contoured tube shapes and isothermality Anal. Chem. 1993 65 748. (Dept. Chem. Biochem. Univ. Texas Austin TX 78712 USA). Takatera K. Watanabe T. Speciation of iodo amino acids by high-performance liquid chromatography with inductively coupled plasma mass spectrometric detec- tion Anal.Chem. 1993 65 759. (Inst. Ind. Sci. Univ. Tokyo Tokyo 106 Japan). Fischer R. Rapsomanikis S. Andreae M. O. Determi- nation of methylmercury in fish samples using GC-AA and sodium tetraethylborate derivatization Anal. Chem. 1993,65 763. (Biogeochem. Dept. Max Planck Inst. Chem. 6500 Mainz Germany). Chambers D. M. McLuckey S . A Glish G. L. Role of gas dynamics in negative ion formation in an atmos- pheric sampling glow discharge ionization source Anal. Chem. 1993 65 778. (Anal. Chem. Div. Oak Ridge Natl. Lab. Oak Ridge TN 37831-6365 USA). Kasthurikrishnan N. Koropchak J. A. Flow injection Donnan dialysis preconcentration of trace metal cations for inductively coupled plasma atomic emission spec- trometry Anal.Chem. 1993 65 857. (Dept. Chem. Biochem. South. Illinois Univ. Carbondale IL 6290 1- 4409 USA). Tian C.-s. Stingeder G. Bubert H. Reduction of secondary-ion mass spectrometry matrix effect for high dose chromium and cobalt implanted silicon Anal. Chem. 1993 65 1035. (Inst. Anal. Chem. Tech. Univ. Wien A- 1060 Vienna Austria). Benzo Z. Araujo P. Sierraalta A. Ruette F. Experi- mental and theoretical studies of the factors that influence the determination of molybdenum by elec- trothermal atomic absorption spectroscopy Anal. Chem. 1993 65 1107. (Cent. Quim. IVIC Caracas 1020-A Venezuela). Riciputi L. R. Christie W. H. Cole D. R. Rosseel T. M. Analysis for rare earth elements in silicates by ion microprobe using doubly-charged ions Anal.Chem. 1993 65 1 186. (Oak Ridge Natl. Lab. Oak Ridge TN Colodner D. C. Boyle E. A. Edmond J. M. Determi- nation of rhenium and platinum in natural waters and sediments and iridium in sediments by flow injection isotope dilution inductively coupled plasma mass spec- trometry Anal. Chem. 1993 65 1419. (Dept. Earth Atmos. Planet. Sci. Massachusetts Inst. Technol. Cam- bridge MA 02 139 USA). Wunderlich R. K. Wasserburg G. J. Hutcheon I. D. Blake G. A. Laser-induced isotopic effects in titanium resonance ionization Anal. Chem. 1993 65 141 1. (Div. Geol. Planet. Sci. California Inst. Technol. Pasadena CA 9 1 125 USA). Beary E. S. Paulsen P. J. Selective application of chemical separations t o isotope dilution inductively coupled plasma mass spectrometric analyses of standard reference materials Anal.Chem. 1993,65 1602. (Natl. Inst. Stand. Technol. Gaithersburg MD 20899 USA). Saito M. Influence of operating parameters on ion intensity in glow discharge mass spectrometry Anal. 37831-6365 USA). 9313446. 9313447. 9313448. 9313449. 9313450. 931345 1. 9 313452. 9313453. 9313454. 931345 5. 9 31345 6. 9 31345 7. 9313458. 9313459. Chim. Acta 1993 274 327. (National Research Inst. Metals Tokyo Japan). Bloxham M. J. Hill S. J. Worsfold P. J. Analysis for trace metals in sea-water by inductively coupled plasma mass spectrometry and related techniques Anal. Proc. 1993 30 159. (Dept. Environ. Sci. Univ. Plymouth Plymouth Devon UK PL4 8AA). Lamberty A. De Bievre P. Gotz A. International measurement evaluation programme IMEP-2 cadmium in polyethylene Fresenius’ J.Anal. Chem. 1993 345 310. (Cent. Bur. Nucl. Meas. Comm. Eur. Communi- ties B-2440 Geel Belgium). Lamberty A. De Bievre P. CBNM-determination of lithium in BCR reference materials RM 303 and RM 304 lyophilized serum by isotope dilution mass spectro- metry (IDMS) Fresenius’ J. Anal. Chem. 1993 345 330. (Cent. Bur. Nucl. Meas. Comm. Eur. Communi- ties B-2440 Geel Belgium). Klinkenberg H. Beeren T. Van Borm W. Mevissen B. Van Dongen C. Instrumental improvement of the XYZ-translation system for a Perkin-Elmer Sciex Elan 500 ICP-MS Spectrochim. Acta Part B 1993 48 475. (Dept. FA-AE DSM Res. 6160 MD Geleen The Netherlands). Cheatham M. M. Sangrey W. F. White W. M. Sources of error in external calibration ICP-MS analysis of geological samples and an improved non-linear drift correction procedure Spectrochim.Acta Part B 1993 48 E487. (Dept. Geol. Sci. Cornell Univ. Ithaca NY Walder A. J. Abell I. D. Platzner I. Freedman P. A. Lead isotope ratio measurement of NIST 610 Glass by laser ablation inductively coupled plasma mass spectro- metry Spectrochim. Acta Part B 1993,48 397. (Fisons Instrum. VG Elem. Winsford Cheshire UK CW7 3BX). Lal K. Characterization of single crystal materials Adv. Crystallogr. Cryst. Growth Proc. Indo-Sov. Symp. Cryst. Growth 1989 125. (Cent. Charact. Mater. Electron. Natl. Phys. Lab. New Delhi 110 012 India). Dulski T. R. Residual-element analysis measuring the miniscule Adv. Mater. Processes 1992 141 20. (Car- penter Technol. Corp. Reading PA USA).Asher S. E. Kalejs J. P. Bathey B. SIMS analysis of chromium gettering in crystalline silicon AIP Conf Proc. 1992 268 409. (Natl. Renewable Energy Lab. Golden CO 8040 1 USA). Steffes G. Luck J. Bloedorn W. Analysis of biological standard reference materials with the spectroflame ICP Alimenta 1993 32 8. (Hahn-Meitner Inst. Berlin GmbH D-1000 Berlin 39 Germany). Nutting D. F. Tolley E. A. Toth L. A. Ballard S. D. Brown M. A. Serum amylase activity and calcium and magnesium concentrations in young cattle grazing fes- cue and Bermuda grass pastures Am. J. Vet. Rex 1992 53 834. (Coll. Med. Univ. Tennessee Memphis TN 38163 USA). Merrer R. J. Berthrong P. Academic LIMS auto- mated data acquisition Am. Lab. (Shelton Conn.) 1992 24 17. (West. Connecticut State Univ. Danbury CT USA).Ghaffari S. Ingle J. D. Jr. Computer-controlled multi- hollow cathode lamp pulsing circuitry system Am. Lab. (Shelton Conn.) 1992 24 50 52. (Chem. Dept. Mount Marty Coll. Yankton SD USA). Merrer R. J. Berthrong P. Claffey K. Academic LIMS Automated determination of calcium in human serum by AA Am. Lab. (Shelton Conn.) 1992 24 15 18. (West. Connecticut State Univ. Danbury CT USA). 14853- 1504 USA).JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY. DECEMBER 1993 VOL. 8 381R 9313460. 931346 I. 9313462. 93i3463. 9313464. 9 31346 5. 9313466. 9 31 346 7. 9313468. 9313469. 9313470. 931347 1. 9313472. 9313473. 9313474. Murphy D. Increased sample throughput using an echelle ICP-AES spectrometer Am. Lab. (Shelton Conn.) 1992 24 205 20L. (ICP Leeman Labs. Inc.Lowell MA USA). Zehr B. D. Development of inorganic microwave dissolutions Am. Lab. (Shelton Conn.) 1992 24 24 26. (Sylvania ChemicalslMetals GTE Prod. Corp. Towanda PA USA). Rarnaley L. Guy R. D. Stephens R. Simple atomic spectrometer for use in the undergraduate laboratory Anal. Instrum. (N. Y.) 1992 20 171. (Trace Anal. Res. Cent. Dalhousie Univ. Halifax Nova Scotia Canada B3H 453). Al-Swaidan H. M. Determination of vanadium and nickel in oil products from Saudi Arabia by inductively coupled plasma mass spectrometry (ICP-MS) Anal. Lett. 1993 26 141. (Coll. Sci. King Saud Univ. Riyadh 1 145 1 Saudi Arabia). Bhattacharyya S. S. Dan S. R. Das A. K. Determina- tion of vanadium in coal fly ash by electrothermal atomic absorption spectrometry Anal. Lett. 1993 26 295.(Dept. Chem. Univ. Burdwan Burdwan 713 104 India). Fukushi K. Willie S. N. Sturgeon R. E. Sub- nanogram determination of inorganic and organic mercury by helium-microwave induced plasma- atomic emission spectrometry Anal. Lett. 1993 26 325. (Res. Inst. Mar. Cargo Transp. Kobe Univ. Merc. Mar. Kobe 658 Japan). Bhattacharyya S. S. Chakraborty R. Das A. K. Determination of titanium in coal fly ash by ETAAS Anal. Lett. 1993 26 341. (Dept. Chem. Univ. Burdwan Burdwan 7 1 3 104 India). Sang H. Y. Hyon P. S. Chon C. H. Pyung M. J. Seog C. J. Gun K. S. SIMS (secondary-ion mass spectrometry) analysis of the behaviour of boron im- planted into single silicon during the titanium-silicide formation Anal. Sci. Technol. 1992 5 199. (Dept. Mater. Eng. Hanyang Univ. Seoul 133-79 1 South Korea). Park Y.J. Yoo H. S. Characterization of atomic emission detector for gas chromatography using cylin- drical microwave cavity Anal. Sci. Technol. 1992 5 263. (Dept. Chem. Chungbuk Natl. Univ. Cheongju 360-763 South Korea). Cho M. S. Lim H.-b. Kim Y . S. Lee K. W. Some effects of acid concentrations in inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry Anal. Sci. Technol. 1992 5 277. (Dept. Chem. Korea Univ. Choongnam 339-700 South Korea). Noack-Fueller G. De Beer C. Seibert H. Cadmium lead selenium and zinc in semen of occupationally unexposed men Andrologia 1993 25 7. (Inst. Toxicol. Univ. Gel D-2300 Kiel Germany). Barney B. Viloria G. Lopata E. Application of optical emission diagnostics and control related to deposition processing Annu.Tech. Conf Proc. -Soc. Vac. Coaters 1992 (35) 319. (ITC Antioch CA USA). Ledingharn K. W. D. Singhal R. P. Laser mass spectrometry Appl. Laser Spectrosc. 1992 365. (Dept. Phys. Astron. Univ. Glasgow UK G12 8QQ). Morohashi S. Kataoka Y. Imamura T. Hasuo S. Secondary-ion mass spectrometry study for Josephson junction with niobiumlaluminum oxide-aluminum1 niobium NbIAI0,-AIlNb structure Appl. Phys. Lett. 1993 62 1164. (Fujitsu Lab. Ltd. Atsugi Japan). Hultqsist G. Seo M. Lu Q. Chuah G. K. Tan K. L. Surface reactions at 300-750 K in the iron-oxy- gen-water system studied by SIMS Appl. Surf Sci. 1992 59 135. (Dept. Phys. Chem. R. Inst. Technol. S- 100 44 Stockholm Sweden). 931347 5. 9313476. 931347 7. 9313478. 9313479.9313480. 931348 1. 9313482. 9313483. 9313484. 93/34 8 5. 9313486. 9313487. 9313488. 9313489. Prudon G. Some examples of depth resolution in SIMS analysis Appl. Surf. Sci. 1993 63 62. (Inst. Natl. des Sci. Appl. de Lyon Lab. Phys. de la Matiere Assoc. au CNRS (URA 358) 20 Bd Albert Einstein 69621 Villeurbanne France). Johann L. Stuck R. Kern Ph. Sipp B. Siffert P. Sputter induced resonant ionization spectroscopy for trace analysis in silicon Appl. Surf Sci. 1993 63 75. (Cent. Rech. Nucl. (CRN)-Lab. PHASE (UPR du CNRS n 292) B.P. 20 67037 Strasbourg 2 France). Tarlov M. J. Evans J. F. Newrnan J. G. Static SIMS and XPS study of water plasma exposed tin oxide films Appl. Surf Sci. 1993 64 115. (Dept. Chem. Univ. Minnesota Minneapolis MN 55455 USA). Das B. C. Determination of gold and silver in activated carbon by atomic absorption spectrometry AuslMM Proc.1992 297 25. (Kalgoorlie Metall. Lab. Dept. Mines Australia). Qi D.-q. Yang Y. Li Y. Li D.-f. Cao LA. Zhao C.-y. Chernoffs face-multivariate display methodology in the analysis of trace elements in sea-water Beijing Daxue Xuebaa Ziran Kexueban 1992 28 134. (Dept. Chem. Peking Univ. Beijing China). Nordstrom E. G. Karlsson K. H. Chemical characteri- zation of a potassium hydroxyapatite prepared by soaking in potassium chloride and carbonate solutions Bio-Med. Mater. Eng. 1992 2 185. (Dept. Chem. Eng. Abo Akad. Univ. SF-20500 Turku Finland). Nguyen T. Brownell G. L. Holden S. A. Teicher B. A. Intracellular distribution of various boron com- pounds for use in boron neutron capture therapy Biochem.Pharmacol. 1993,45 147. (Nucl. Eng. Dept. Massachusetts Inst. Technol. Cambridge MA 02 139 USA). Recklidge G. J. Milne G. McGaw B. A. Milne E. Robins S. P. Turnover rates of different collagen types measured by isotope ratio mass spectrometry Biochirn. Biophys. Acta 1992 1156 57. (The Rowett Res. Inst. Greenburn Road Bucksburn Aberdeen UK). Gruny G. Determination of lead in wine and alcoholic media by using an autoprobe system Bios (Nancy) 1991 22 47. (UNICAM France 93003 Bobigny France). Belloni N. Malla M. Alvarez M. ROSO E. Determi- nation of vanadium by atomic absorption spectrometry. I. Study of interference and effect of the flame Bol. SOC. Quim. Peru 1992 58 173. (Dept. Quim. Ing. Quim. Univ. Nac. Sur. 8000 Bahia Blanca Argentina).Malla M. Alvarez M. Belloni N. ROSO E. Determi- nation of vanadium by atomic absorption spectrometry. 11. Analysis in steels Bol. SOC. Quirn. Peru 1992 58 181. (Dept. Quim. Ing. Quim. Univ. Nac. Sur. 8000 Bahia Blanca Argentina). Mantelli F. Falugi G. Bucci P. Masini M. Heavy metals in recent snow in Bassa Valdelsa rural district sampling methods and analyses Boll. Chim. Ig.. Parte Sci. 1992 43 177. (Unita Oper. Chim. Ambientale I SMP Florence Italy). Wing A. M. Effects of whole wheat wheat bran and zinc in the diet on the absorption and accumulation of cadmium in rats Br. J. Nutr. 1993 69 199. (Dept. Nutr. Res. Univ. Umea S-901 87 Umea Sweden). Woo J. C. Kim H. J. Lim H. B. Moon D. W. Lee K. W. Study of the optimization and the depth profile using a flat-type ion source in glow-discharge mass spectrometry Bull.Korean Chem. SOC. 1992 13 620. (Inorg. Anal. Chem. Lab. Korea Res. Inst. Stand. Sci. Taejon 305-606 South Korea). Custo G. C. De Leyt D. V. Guido 0. O. Analysis of micronutrients in soybean by X-ray fluorescence. Deter- mination of zinc copper iron and manganese Can. J.382R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 9313490. 931349 1. 9313492. 9313493. 9313494. 9313495. 9313496. 9313497. 9313498. 9313499. 9313500. 931350 1. 9313 502. 9313503. Appl. Spectrosc. 1992 37 176. (Comision Nac. Energ. At. 1429 Buenos Aires Argentina). Rambal C. Pachiaudi C. Normand S. Riou J. P. Louisot P. Martin A. Use of compunds naturally labelled with stable isotopes for the study of the metabolism of glycoprotein neutral sugars by gas- liquid chromatography-isotope ratio mass spectro- metry.Technical validation in the rat Carbohydr. Res. 1992 236 29. (Dept. Gen. Med. Biochem. Fac. Med. Lyon-Sud F-6992 1 Oullins France). Kalavska D. Optimization and unification of water analysis Chem. Anal. (Warsaw) 1992 37 501. (Dept. Ecosozol. Physiotact. Comenius Univ. Bratislava Czechoslovakia). Nakahara T. Wasa T. Atomic emission spectrometry of mercury by atmospheric-pressure argon microwave- induced plasma with continuous-flow cold vapour gen- eration Chem. Express 1993 8 13. (Dept. Appl. Chem. Univ. Osaka Prefect. Sakai 593 Japan). Valley J. W. Graham C. M. Oxygen isotope measure- ment of magnetites Chem. Geol. 1992,101 173. (Dept. Geol. Geophys. Univ. Wisconsin Madison WI 53706 USA).Hall G. E. M. Vaive J. E Determination of fold in geological samples by anodic stripping voltammetry at field locations Chem. Geol. 1992 102 41. (Geol. Surv. Canada Ottawa Ontario Canada K 1 A OE8). Vennemann T. W. O’Neil J. R. A simple and inexpensive method of hydrogen isotope and water analyses of minerals and rocks based on zinc reagent Chem. Geol. 1993 103 227. (Dept. Geol. Sci. Univ. Mich. Ann Arbor MI 48109 USA). McDermott F. Elliott T. R. van Calsteren P. Hawkes- worth C. J. Measurement of 230Th:232Th ratios in young volcanic rocks by single-sector thermal ionization mass spectrometry Chem. Geol. 1993,103,283. (Dept. Earth Sci. The Open Univ. Walton Hall Milton Keynes UK MK7 6AA). Paukert T. Determination of noble metals in rocks waters and plants by inductively coupled plasma mass spectrometry Chem.Listy 1993 87 8. (Cesky Geol. Ustav 1 18 2 1 Prague Czechoslovakia). Hedges R. How old is Pharaoh’s coffin? Chem. Rev. (Deddington U. K.) I 99 1 1 2. (Radiocarbon Accel. Unit Oxford Univ. UK). Shan X.-q. Chen B. Jin L.-z. Zheng Y. Hou X.-p. Mou S.-f. Determination of sulfur fractions in soils by sequential extraction inductively coupled plasma opti- cal emission spectroscopy and ion chromatography Chem. Speciation Bioavailability 1992 4 97. (Res. Cent. Eco-Environ. Sci. Acad. Sin. Beijing 100085 China). Matsumoto T. Nishiguchi K. Suzuki K. Ishiwata Y. Ebihara N. Elements contained in natural gas brine Chiba-ken Kogyo Shikejo Kenkyu Hokoku 1 99 1 5 10. (Ind. Res. Inst. Chiba Prefect. Chiba 280 Japan). Han Y.Approach to analysis of stable isotopes in microsamples Chin. J. Geochem. 1991 10 372. (Yichang Inst. Geol. Miner. Resour. CAGS Yichang 443003 China). Zhang Q.-l. Chen G. Xiao Y.-k. Qi H.-p. Calibrated mass-spectrometric measurement of the atomic weight of lithium Chin. Sci. Bull. 1992,37,915. (Dept. Chem. Peking Univ. Beijing 10087 I China). Uden P. C. Zeng Y. Study of diastereoisomerism of oxovanadium Schiff base chelates by gas chromatogra- phy-atomic emission spectroscopy and high perform- ance liquid chromatography Chromatographia 1992 34 269. (Dept. Chem. Univ. Massachusetts Amherst MA 01003 USA). 9313504. 9313505. 9313506. 9313507. 9313508. 9313509. 93/35 10. 93/35 1 I . 93/35 12. 93/35 13. 93/35 14. 93/35 15. 93/35 16. Golloch A. Haveresch-Kock M. Fischer W.G. Electrothermal evaporation-a sample introduction system for solids in the inductively coupled plasma (ICP) CLB Chem. Labor Biotech. 1993 44 75 79. (Fachbereich 6lInstrum. Anal. Univ.-Gesamthochsch. Duisburg Duisburg Germany). Schneider R. J. Von Reden K. F. Purser K. H. Triple- isotope injector for accelerator mass spectrometry Con$ Rec. IEEE Part. Accel. Con$ 14th 1991 2 878. (Woods Hole Oceanogr. Inst. Woods Hole MA 02543 USA). Hitzman C. J. SIMS determination of oxygen and nitrogen in metal alloys using CsO+ and CsN+ molecu- lar ions Clean Steels Technol. Proc. Robert I. Jafsee Meml. Symp. Clean Mater. Technol. 1992 I 1 1. (Charles Evans and Associates Redwood City CA USA). Reidenberg M. M. Gu Z. P. Lorenzo B. Coutinho E. Athayde C. Frick J. Alvarez F.Brache V. Emu- veyan E. E. Differences in serum potassium concentra- tions in normal men in different geographic locations Clin. Chem. (Washington D. C.) 1993 39 72. (Med. Coll. Cornell Univ. New York NY 10021 USA). Beverly R. B. Peters J. B. Njie S. Schulte E. E. Application of soil testing in the Gambia Commun. Soil Sci. Plant Anal. 1992 23 2339. (Georgia Exp. Stn. Griffin GA USA). Brown P. H. Picchioni G. Jenkin M. Mu H. Use of ICP-MS and boron-10 to trace the movement of boron in plants and soil Commun. Soil Sci. Plant Anal. 1992 23 2781. (Dept. Pomol. Univ. California Davis CA 95616 USA). Vaughan B. Miller R. Howe J. Peristaltic pump application for automated dilution during atomic ab- sorption spectroscopy analysis Commun. Soil Sci. Plant Anal. 1993 24 125.(Harris Lab. Inc. Lincoln NE 68502 USA). Brooks A. W. White K. N. Bailey S. E. R. Accumula- tion and excretion of aluminium and iron by the terrestrial snail Helix aspersa Comp. Biochem. Physiol. C Comp. Pharmacol. Toxicol. 1992 103 577. (Dept. Environ. Biol. Univ. Manchester Manchester UK M13 9PL). Alexander M. R. Jones F. R. Use of time-of-flight secondary-ion mass spectrometry (TOF SIMS) and epoxide molecular probes to study the interface in carbon fibre-epoxy composites Compos. Proc. Znt. ConJ Compos. Mater. 8th 1991 1 11G. (Sch. Mater. Univ. Sheffield Sheffield UK S10 2TZ). Soni K. K. Williams D. B. Newbury D. E. Chi P. Downing R. G. Lamaza G. Depth distribution of lithium in oxidized binary aluminium-lithium alloys determined by secondary-ion mass spectrometry and neutron depth profiling Corrosion (Houston) 1993,49 31.(Enrico Fermi Inst. Univ. Chicago Chicago IL 60637 USA). Majidi V. Joseph M. R. Spectroscopic applications of laser-induced plasmas Crit. Rev. Anal. Chem. 1992,23 143. (Dept. Chem. Univ. Kentucky Lexington KY 40506 USA). Brenner I. B. Taylor H. E. Critical review of induc- tively coupled plasma mass spectrometry for geo- analysis geochemistry and hydrology. Part I. Analytical performance Crit. Rev. Anal. Chem. 1992 23 355. (Geol. Surv. Israel 95501 Jerusalem Israel). Zhou S.-t. Liu Y.-k. Secondary-ion mass spectro- metry study of the fingerprint characteristics of min- erals-with special reference to minerals from the Jinningian granites in the Yunnan sector of the Xikang-Yunnan axis Dizhi Xuebao 199 1 65( l) 27.(Inst. Geochem. Acad. Sin. Guiyang Guizhou China).JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 383R 93/35 17. 93/35 18. 93/35 19. 9313520. 931352 1. 9313522. 9313523 9313524. 9313525. 9313526. 9313527. 9313528. 9313529. 9313 5 30. 931353 1. 9313532. Lukin A. Garipov O. Mercury belt of the mid-latitude Ob River region in western Siberia Dokl. Akad. Nauk 1992 325 1 198. (Inst. Geol. Nauk Kiev Ukraine). Sokolowska Z. Sobolewski A. Optic system of secon- dary ions in SIMS spectrometer Elektronika 1992,33 19. (OBREP Warsaw Poland). Xhoffer C. Wouters L. Artaxo P. Van Put A Van Grieken R. Characterization of individual environ- mental particles by beam techniques Environ. Part. 1992 1 107. (Dept. Chem. Univ. Antwerp Antwerp Belgium).Abbas M. Z. M. Bruns R. E. Scarminio I. S. Ferreira J. R. Multivariate statistical analysis of the compo- sition of rainwater near Cubatao SP Brazil Environ. Pollut. 1993 79 225. ( 13.400 Piracicaba Brazil). Sharma V. K. Patil R. S. Chemical composition and source identification of Bombay aerosol Environ. Tech- nol. 1992 13 1043. (Indira Gandhi Inst. Dev. Res. Bombay 400076 India). Mihaylov B. Hendrix J. Continuous precipitation and separation of copper cadmium mercury and arsenic EPD Congr. 1992 Proc. Symp. TMSAnnu. Meet. 1992 81. (Mackay Sch. Mines Univ. Nevada Reno NV 89557 USA). Weinbruch S. Specht S. Palme H. Determination of iron manganese nickel and scandium in olivine by secondary-ion mass spectrometry Eur. J. Mineral. 1993 5 37. (Max-Planck-Inst. Chem.D-6500 Mainz Germany). Rokita E. Cichocki T. Divoux S. Gonsior B. Hofert M. Jarczyk L. Strzalkowski A. Calcification of the aortic wall in hypercalcemic rabbits Exp. Toxicol. Pathol. 1992 44 31 0. (Inst. Phys. Jagellonian Univ. 30059 Krakow Poland). He H.-k. Xie Y.-s. Application of LPDA technology in graphite furnace atomic absorption spectroscopy. (11). A new method for background correction Fenxi Ceshi Tongbao 1992 11 1. (Chin. Natl. Anal. Cent. Canton 5 10070 China). Wang J.-p. Deng B. Mechanism of atomization on the graphite probe surface in graphite furnace. VIII. Atomi- zation mechanism for tin Fenxi Ceshi Tongbao 1992 11 7. (Dept. Chem. Tsinghua Univ. China). Liang S.-.t Xue Z.-l. Determination of rare earth elements and scandium in geochemical samples with ICP-AES using cupferron as precipitant Fenxi Ceshi Tongbao 1992 11 44.(Anhui Geol. Exp. Inst. China). Jin L.-t. Xu J.-y. Qian J.-r. Tong W. Nafion- modified electrode preconcentration-graphite furnace atomic absorption spectroscopic determination of trace silver Fenxi Ceshi Tongbao 1992 11 56. (Dept. Chem. East China Normal Univ. China). Wang S.-y. Liu J. Chen X.-h. Determination of trace 14 rare earth elements in cerium oxide by inductively coupled plasma atomic emission spectrometry Fenxi Huaxue 1992,20 1273. (Changchun Inst. Appl. Chem. Chin. Acad. Sci. Changchun 130022 China). Ye M.-w. Deng Y.-z. Pulsed laser-induced photo- acoustic determination of chromium in biological materials Fenxi Huaxue 1992 20 1378. (Dept. Anal. Test. Sci. Wuhan Univ. Wuhan 430072 China).Zhang JA. Yao T.-s. Indirect determination of tetradecylpyridinium bromide by flame atomic absorp- tion spectrometry Fenxi Huaxue 1992 20 1479. (Dept. Appl. Chem. Southwest Pet. Coll. Nanchong China). Li Y.-h. Zhu C.-f. Fu M. Rapid determination of trace elements in antimony metal by inductively coupled plasma atomic emission spectrometry Fenxi 9313 5 3 3. 9 313 5 34. 93/35 35. 9313 5 36. 9313 5 3 7. 9313538. 9313539. 9313 540. 931354 1. 9313542. 9313543. 9313 544. 9313545. Huaxue 1992 20 1482. (Hunan Import-Export Insp. Bur. Changsha 4 10007 China). Hu B. Jiang Z.-c. Zeng Y. Direct determination of micro-amount of vanadium and titanium in NIST coal by slurry sampling combined with fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry Fenxi Huaxue 1993,21 6.(Dept. Chem. Wuhan Univ. Wuhan 430072 China). Fu F.-f. Zhang Z.-z. Zheng J.-d. Zhang M.-w. Determination of copper manganese and zinc in wheat flour rice flour and pork liver by atomic absorption spectrometry using nebulization of acid-extracted sus- pensions Fenxi Huaxue 1993 21 123. (Dept. Chem. Fuzhou Univ. Fuzhou 350002 China). Yao J.-y. Song J.-y. Zhou J.-r. Wei Y.-d. Atomic absorption determination of fifteen trace metals in ginsengs Fenxi Shiyanshi 1990 9 16 2 1. (Changchun Inst. Appl. Chem. Acad. Sin. Changchun 130022 China). Shi Q.-z. Zhang Y.-h. Adsorptive voltammetric study of zinc-tetra-(4-methoxy-3-sulfophenyl)porphyrin com- plex Fenxi Shiyanshi 1992 11 3 9. (Dept. Chem. Hangzhou Univ. Hangzhou 3 10028 China).Chen Y.-s. Liu Y.-f. Jia G.-p. Determination of available nickel cobalt copper and sulfur in soil Fenxi Shiyanshi 1992 11 50. (Xi’an Res. Inst. Nonferrous Met. Prospect. Xian 7 10054 China). Zhao X.-f. Direct spectrographic determination of potassium and sodium in uranium oxide (U,O,) with electric spark technique Fenxi Shiyanshi 1992 11 57. (Shijiazhuang Tractor Plant Shijiazhuang 050033 Chin a). Ma G.-y. Dong H. An W.-d. ICP-AES method for determination of copper iron aluminium and zinc in tin solder Fenxi Shiyanshi 1992 11 59. (Chem. Eng. Dept. Tianjin Inst. Technol. Tianjin 3001 91 China). Liu Z.-f. Cai H.-d. Zhao J. Graphite furnace AAS determination of aluminium in tin-based alloys Fenxi Shiyanshi 1992 11 62. (Shenyang Control Inspect.Inst. Product Qual. Shenyang 1 10003 China). Kanunnikova 0. M. Gil’mutdinov F. Z. Kadikova A. Kh. Elsukov E. P. Lad’yanov V. I. Rats Yu. V. Comparative analysis of the surface layer composition of amorphous iron-boron-silicon and iron-phospho- rus-carbon alloys by XPS AES and SIMS Fiz. Met. Metalloved. 1992 7 70. (Fiz.-Tekh. Inst. Izhevsk Russia). Crews H. M. Baxter M. J. Bigwood T. Burrell J. A Owen L. M. Robinson C. Wright C. Massey R. C. Lead in feed incident-multi-element analysis of cattle feed and tissues by inductively coupled plasma mass spectrometry and co-operative quality assurance scheme for lead analysis of milk Food Addit. Contam. 1992 9 365. (Food Sci. Lab. Minist. Agric. Fish. Food Norwich UK NR4 7UQ). Vinas P. Campillo N. Lopez Garcia I. Hernandez Cordoba M.Rapid determination of calcium magne- sium iron and zinc in flours using flow injection flame atomic absorption spectrometry for slurry atomization Food Chem. 1993,46 307. (Fac. Chem. Univ. Murcia Murcia E-3007 1 Spain). Buckley W. T. Ihnat M. Determination of copper molybdenum and selenium in biological reference materials by inductively coupled plasma mass spectro- metry Fresenius’J. Anal. Chem. 1993,345,2 17. (Agric. Canada Res. Stn. British Columbia Canada VOM 1AO). Qui D. Reaction modes of stannane generation Fudan Xuebao Ziran Kexueban 1992 31 23. (Dept. Chem. Fundan Univ. Shanghai China).384R 9313546. 9313547. 931 3548. 9313549. 9313550. 931 355 1. 9313552. 93/35 53. 9 313 5 54. 9313 5 5 5. 9313556. 9313557. 93/35 58. 9313559. 931 3560.9313561. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Blazek J. Sebor G. Formation of asphaltenes and carbenes during thermal conversion of petroleum mal- tenes in the presence of hydrogen Fuel 1993 72 199. (Dept. Pet. Technol. Petrochem. Inst. Chem. Technol. 166 28 Prague Czechoslovakia). Louie P. K. K. Timpe R. C. Hawthorne S. B. Miller D. J. Determination of elemental sulfur in coal by supercritical fluid extraction and gas chromatography with atomic emission detection Fuel 1993 72 225. (Energy Environ. Res. Cent. Univ. North Dakota Grand Forks ND 58202 USA). Pinkston T. L. Multi-element determination of trace contaminants in photoresist materials by inductively coupled plasma mass spectrometry Future Pract. Con- tam. Control Proc. Int. Symp.Contam. Control Ilth 1992 535. (Sematech Inc. USA). Duan Y.-x. Du Z.-h. Hou M.-y. Liu J. Jin Q.-h. Performance comparison between two different absorp- tion cells used in MIP-AAS for determination of nickel Gaodeng Xuexiao Huaxue Xuebao 1992 13 1176. (Dept. Chem. Jilin Univ. Changchun 130023 China). Duan Y.-x. Lu H. Hou M.-y. Zhang H.q. Jin Q.-h. Determination of copper by microwave-induced plasma atomic absorption spectrometry Gaodeng Xuexiao Huaxue Xuebao 1992,13 124 1. (Dept. Chem. Jilin Univ. Changchun 130023 China). Paukert T. Analysis of trace amounts of rare earth elements in rocks Geol. Pruzkum 1992,34,270. (Cesky Geol. Ustav Prague Czechoslovakia). Yurimoto H. Ohtani E. Element partitioning between majorite and liquid a secondary-ion mass spectrometric study Geophys.Res. Lett. 1992 19 17. (Inst. Geosci. Univ. Tsukuba Japan). Hopp W. Quantitative analysis of alkali silicate solu- tions by ICP-AES (inductively coupled plasma atomic emission spectroscopy) Glastech. Ber. 1993 66 1. (Fraunhofer-Inst. Silicatforsch. Wurzburg Germany). Holland R. Blackmore G. W. Review of positive ion sensitivities for the SIMS analysis of CMT (cadmium mercury telluride) Report 199 1 RSRE-9 10 1 5 DRIC- BR-303852; Order AD-A241596 24 pp. (Eng). Avail. NTIS. From Gov. Rep. Announce. Index (US.) 1992 92(3) Abstr. No. 205 865. (R. Signals and Radar Establ. Malvern UK). Chen H. Jiang Z.-c. Zeng Y. Kong L.-y. Study on the effects of matrix and acid in FIA-ICP-AES tech- nique Guangpuxue Yu Guangpu Fenxi 1992,12(3) 49. (Dept. Chem. Wuhan Univ.Wuhan 430072 China). Chen J.-w. Zhou T. Tian S.-j. Determination of rare earth elements in pure terbium oxide by ICP-AES Guangpuxue Yu Guangpu Fenxi 1992,12(3) 53. (Dept. Chem. Peking Univ. Beijing 100871 China). Van Loon J. C. Park. C. J. Paudyn A. B. Wang Z.-x. Li Y.-t. New sample introduction techniques for ICP-MS Guangpuxue Yu Guangpu Fenxi 1992 12(3) 59. (Univ. Toronto Toronto Ontario Canada). Chen H. Jiang Z.-c. Indirect methods in atomic spectrometry Guangpuxue Yu Guangpu Fenxi 1992 12(3) 65. (Dept. Chem. Wuhan Univ. Wuhan 430072 China). Zhang J.-f. Direct current plasma atomic emission spectrometric determination of rare earth impurities in high-purity lathanum oxide and yttrium oxide by using the tchelle grating spectrometer Guangpuxue Yu Guangpu Fenxi 1992,12(3) 7 1.(Northwest Nonferrous Res. Inst. Geol. Xian 710054 China). Wei J.-z. Lin F. Wang X.-s. Study of the sensitivity enhancement effect of some oxidants on lead in flow injection by hydride generation AAS Guangpuxue Yu Guangpu Fenxi 1992 12(3) 7 5 . (Dept. Chem. Nankai Univ. Tainjin 3007 1 China). Wang J.-p. Deng B. Atomization mechanism on the graphite probe surface in graphite furnace. IV. Atomiza- 931 3562. 9313 56 3. 931 3564. 9313 5 6 5. 9313566. 931 3567. 9313568. 9313 5 69. 9313570. 931357 1. 9313572. 931 35 73. 93/35 73a. tion mechanism of vanadium Guangpuxue Yu Guangpu Fenxi 1992 12(3) 83. (Dept. Chem. Tsinghua Univ. Beijing 100084 China). Long S.-h. Li Y.-g. He C. Study on the mechanism of interference with manganese in the determination of trace iron in electrolytic manganese dioxide by flame atomic absorption spectrometry Guangpuxue Yu Guangpu Fenxi 1992,12(3) 89.(Dept. Chem. Xiang- tan Univ. Xiangtan 41 1 105 China). Yao J.-y. Ji Y.-z. Determination of phosphorus with platform graphite furnace atomic absorption spectro -metry Guangpuxue Yu Guangpu Fenxi 1992 12(3) 82. (Changchun Inst. Appl. Chem. Acad. Sin. Changchun 130022 China). Zhoq H.-g. Peng X.-y. Tao R. Slurry technique for the determination of lead in wheat and rice flour by electrothermal atomic absorption spectrometry Guang- puxue Yu Guangpu Fenxi 1992 12(3) 97. (Hyg. Antiepidemic Stn. Chengdu Chengdu 6 1002 1 China). Cai Q.-x. Shen M.-x. Xue C.-f. Determination of intra- and extra-cellular calcium in infantile pneumonia complicated with respiratory failure by AAS method Guangpuxue Yu Guangpu Fenxi 1992 12(3) 105.(Shanghai Inst. Org. Chem. Acad. Sin. Shanghai 200032 China). Liu W.-x. Li J. Wang H.-q. Yin H.-q. Determina- tion of cadmium in stainless steels by platform graphite furnace AAS Guangpuxue Yu Guangpu Fenxi 1992 12(3) 109 116. (52 Res. Inst. Baoto 014000 China). Zhu C.-.f Zhang S.-z. Wang C.-m. Comparative study of determination of boron in silicon crystals by emission spectrometry and electrical measurement Guangpuxue Yu Guangpu Fenxi 1992 12(3) 125. (Electron. Mater. Cent. Ministr. Electr. Mechn. Eng. Tianjin 300 192 China). Deng Z.-g. Mass spectrometric analytical methods for ruthenium isotopes He Huaxue Yu Fangshe Huaxue 1992 14 59. (China Inst. At. Energy Beijing 102413 China). Li S.-l.Hou S.-b. Determination of trace uranium in tea by isotope dilution mass spectrometry He Huaxue Yu Fangshe Huaxue 1992 14 126. (China Inst. At. Energy Beijing 1024 13 China). Shi X.-z. Zhou Y.-m. Li Y.-c. Li X.-f. Fan S.-z. Zhou Z.-w. Analysis of trace elements in Wuziyan- zongwan and its herbal components Hebei Yixueyuan Xuebao 1992 13 137. (Dept. Pharm. Hebei Med. Coll. Shijiazhuang China). Creswell R. G. Radiocarbon dating of iron artefacts using accelerator mass spectrometry Hist. Metall. 1991 25 78. (Univ. Toronto Toronto Ontario Canada). Tanka T. Tanaka N. Kita T. Kasai K. Tanimoto A. Autopsy case of acute arsenic poisoning and determina- tion of arsenic in blood and stomach contents in inductively coupled plasma mass spectrometry (ICP- MS) Hochudoku 1992 10 180.(Dept. Forensic Med. Pathol. Sch. Med. Japan). Takano A. Takahashi T. Tomita K. Sakuta Y. Refining and utilization technology of rare metals. 11. Microanalysis of metal impurities in high-purity nio- bium by inductively coupled plasma atomic emission spectrometry with ion-exchange method Hokkaidoritsu Kogyo Shikenjo Hokoku 1991,290,27. (Hokkaido Ind. Res. Inst. Sapporo 060 Japan). Takano A. Takahashi T. Tomita K. Sakuta Y. Refining and utilization technology of rare metals. 111. Microanalysis of metal impurities in high-purity nio- bium by ion-exchange method Hokkaidoritsu Kogyo Shikenjo Hokoku 1992 291 1. (Hokkaido Ind. Res. Inst. Sapporo 060 Japan).JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 385R 9313574. 9313575. 9313 5 76.9 313 5 7 7. 9313578. 9 313 5 79. 9313580. 931358 1. 9313582. 9313 583. 9313584. 931358 5. 9313586. 931358 7. 9313588. Pan X.-r. Pang R.-f. Luo X. Study on sodium deposition in amorphous sodium iodide-sodium oxide-boron oxide solid electrolyte with AES and work function apparatus Huadong Huagong Xueyuan Xue- bao 1992 18,268. (Dept. Phys. East China Inst. Chem. Technol. Shanghai 200237 China). Xu T.-m. Zhao S.-r. Zhu H. Xu B.-x. Determination of bismuth in drugs by preconcentration as Nafion modified electrode graphite furnace atomic absorption spectrometry Huaxue Shijie 1992 33 220. (Dept. Chem. Huadong Norm. Univ. China). Kamasaki S. Okajima K. Formation of hydrogen absorption titanium-nickel alloy films by r.f. sputtering Hyomen Gijutsu 1992,43 1077. (Fac.Technol. Tokyo Metrop. Univ. Hachioji 192-03 Japan). Tamura H. Process of the development of secondary- ion mass spectrometry (SIMS) Hyomen Kagaku 1992 13 483. (Appl. Technol. Dept. Hitachi Instrum. Eng. Co. Katsuta 312 Japan). Kim Y. S. Choi C. M. Choi H. S. Matrix modifiers for trace heavy metal analysis by graphite furnace AAS Hwahak Sekye 1992 32 1161. (Chem. Dept. Korea Univ. Seoul South Korea). Matsumoto K. Yurimoto H. Kosaka K. Miyata K. Nakamura T. Sueno S. Novel ion imager for secon- dary-ion mass spectrometry IEEE Trans. Electron Devices 1993 40 82. (Semicond. Technol. Cent. Olympus Opt. Co. Tatsuno 399-04 Japan). Reiser H. P. Julian R. K. Jr. Cooks R. G. Versatile method of simulation of the operation of ion trap mass spectrometers Int. J. Mass Spectrom.Ion Processes 1992 121 49. (Dept. Chem. Purdue Univ. West Lafayette IN 47907 USA). Taylor P. D. P. Maeck R. De Bievre P. Determina- tion of the absolute isotopic composition and atomic weight of a reference sample of natural iron Int. J. Mass Spectrom. Ion Processes 1992 121 1 1 1. (Cent. Bur. Nucl. Meas. JRC B-2440 Geel Belgium). England J. G. Zindler A. Reisberg L. C. Rubenstone J. L. Salters V. Marcantonio F. Bourdon B. Brueck- ner H. Turner P. J. Lamont-Doherty Geological Observatory Isolab 54 isotope ratio mass spectrometer Int. J. Mass Spectrom. Ion Processes 1992 121 201. (Lamont-Doherty Geol. Obst. Columbia Univ. Pali- sades NY 10964 USA). Gob A. Lamberty A. De Bievre P. CBNM certifica- tion of cadmium in polyethylene by isotope dilution mass spectrometry Int.J. Mass Spectrom. Ion Processes 1993 123 1. (Cent. Bur. Nucl. Meas. Comm. Eur Commun. B-2440 Geel Belgium). Shima M. Torigoye N. Isotopic composition and atomic weight of titanium Int. J. Mass Spectrom. Ion Processes 1993 123 29. (Natl. Sci. Mus. Tokyo 110 Japan). Chen T. H. Analytical scheme for the identification of unknown military explosive wastes Int. Annu. Conf ICT 1992 23 30. (U. S. Army Armament Res. Dev. Eng. Cent. Picatinny Arsenal NJ 07806-5000 USA). Xiao Y. K. Liu W. G. Qi H. P. Zhang C. G. New method for the high precision isotopic measurement of bromine by thermal ionization mass spectrometry Int. J. Mass Spectrom. Ion Processes 1993 123 117. (Qinghai Inst. Salt Lakes Acad. Sin. Xining 810008 China). De Bievre P. Taylor P. D. P. Table of the isotopic compositions of the elements Int.J. Mass Spectrom. Ion Processes 1993 123 149. (Cent. Bur. Nucl. Meas. JRC B-2440 Geel Belgium). Mitchell D. F. Prescott R. Graham M. J. Doychak J. SIMS studies of oxide growth on P-nickel aluminide Int. SAMPE Tech. Conf.’ 1992 24 M78. (Inst. Micro- 9313 589. 9313 590. 9313591. 9313592. 9313593. 9313594. 9313595. 9313596. 9313597. 9 313 5 98. 9313599. 9313600. 931360 1 struct. Sci. Natl. Res. Counc. Ottawa Ontario Canada Kl A OR6). Smirnov V. K. Simakin S. G. SIMS analysis for a number of elements implanted in silicon during nitro- gen molecular ion bombardment of the surface Izv. Ross. Akad. Nauk Ser. Fiz. 1992 56 101. (Inst. Mikroelekt. Russia). Dorozhkin A. A. Kovarskii A. P. Li-Fatu A. V. Negative hydrogen-containing ions in the mass-spectra of the secondary-ion emissions from niobium and tantalum Izv.Ross. Akad. Nauk Ser. Fiz. 1992 56 106. (St. Petersburg. Tekh. Inst. St. Petersburg Russia). Doner L. Brause A. R. Petrus D. R. cY80 measure- ments in water for detection of sugar beet-derived syrups in frozen concentrated orange juice collabora- tive study J. AOAC Int. 1992,75 1 107. (East. Reg. Res. Cent. U.S. Dept. Agric. Philadelphia PA 191 18 USA). Potter G. E. Knudsen A. K. Tou J. C. Choudhury A. Measurement of the oxygen and impurity distribution in polycrystalline aluminium nitride with secondary-ion mass spectrometry J. Am. Cerarn. Soc. 1992 75 321 5. (Dow Chem. Co. Midland MI 48664 USA). Furner R. L. Alarcon R. D. Irving T. Quadrupole- based mass spectrometric evaluation of isotope ratios of carbon dioxide in expired air from mice and men following the administration of 13C-methyl methionine J.Am. SOC. Mass Spectrom. 1992 3 742. (Dept. Psychiatry Behavioral Neurobiol. Univ. Alabama Birmingham AL USA). Hu K. Clemons P. S. Houk R. S. Inductively coupled plasma mass spectrometry with an enlarged sampling orifice and offset ion lens. I. Ion trajectories and detector performance J. Am. SOC. Mass Spectrom. 1993 4 16. (Dept. Chem. Iowa State Univ. Ames 1A 5001 1 USA). Hu K. Houk R. S. Inductively coupled plasma mass spectrometry with an enlarged sampling orifice and offset ion lens. 11. Polyatomic ion interferences and matrix effects J. Am. SOC. Mass Spectrom. 1993 4 28. (Dept. Chem. Iowa State Univ. Ames IA 5001 1 USA). Barshick C.M. Duckworth D. C. Smith D. H. Analysis of solution residues by glow discharge mass spectrometry J. Am. SOC. Mass Spectrom. 1993 4 47. (Anal. Chem. Div. Oak Ridge Natl. Lab. Oak Ridge Aggarwal S. K. Orth R. G. Wendling J. Kinter M. Herold D. A. Isotope dilution gas chromatography- mass spectrometry for cadmium determination in urine J. Anal. Toxicol. 1993 17 5. (Health Sci. Cent. Univ. Virginia Charlottesville VA 22908 USA). Middleberg R. A. Easterling D. E. Zelonis S. F. Rieders F. Rieders M. F. Estimation of perimortal percent carboxy-haeme in non-standard postmortem specimens using analysis of carbon monoxide by GC-MS and iron by flame atomic absorption spectro- photometry J. Anal. Toxicol. 1993 17 11. (Natl. Med. Serv. Willow Grove PA 19090 USA). Likonen J.Hautala M. Koponen I. Secondary-ion mass spectrometry study of low-energy ion-beam mixing of gold-platinum interfaces J. Appl. Phys. 1992 72 5898. (React. Lab. Tech. Res. Cent. Finland SF-021 50 Espoo Finland). Pas M. F. Magel L. K. Anthony M. Hemming S. Depth profiles of arsenic and antimony angle-implanted trenches measured by secondary-ion mass spectrometry J. Appl. Phys. 1993,73 84. (Dallas MOS IV Wafer Fab Texas Instrum. Dallas TX 75265 USA). De la Cal E. Tafalla D. Tabares F. L. Characteriza- tion of heliumlmethane d.c. glow discharge plasmas by optical emission spectroscopy mass spectrometry and actinometry J. Appl. Phys. 1993 73 948. (Ciemat Madrid 28040 Spain). TN 3783 1-6375 USA).386R 9313602. 9313603. 9313604. 9313605. 9313606. 9313607- 9313608.9313609. 93/36 10. 93/36 1 1. 93/36 12. 93/36 13. 93/36 93/36 JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Hermann J. Boulmer-Leborgne C. Mihailescu 1. N. Dubreuil B. Multistage plasma initiation process by pulsed carbon dioxide laser irradiation of a titanium sample in an ambient gas helium argon and nitrogen J. Appl. Phys. 1993 73 1091. (Orleans Univ. 45067 Orleans France). Gauneau M. Chaplain R. Rupert A. Toudic Y. Callec R. Secondary-ion mass spectrometry generates swelling of gallium antimonide depth resolution and secondary-ion yields J. Appl. Phys. 1993 73 205 1. (Cent. Natl. Etud. Telecomm. France Telecom 22301 Lannion France). Moore J. T. Silversmith R. E. Maley G. F. Maley F. T4-phage deoxycytidylate deaminase in a metallo- protein containing two zinc atoms per subunit J.Biol. Chem. 1993 268 2288. (Sch. Public Health State Univ. New York Albany NY 12201-0509 USA). Ducros V. Favier A. Gas chromatographic-mass spectrometric method for the determination of selenium in biological samples J. Chromatogr. Biomed. Appl. 1992 583 35. (Lab. Biochim. C Hop. A. Michallon 38043 Grenoble France). Jinno K. Inductively coupled plasma atomic emission spectrometric detection in supercritical fluid chromato- graphy J. Chromatogr. Libr. 1992 53 151. (Sch. Mater. Sci. Toyohashi Univ. Technol. Toyohashi 44 1 Japan). Bardwell J. A. Sproule G. I. Graham M. J. Ex situ surface analysis of passive films on iron-chromium alloys. When is it valid? J. Electrochem. SOC. 1993 140( I) 50. (Inst. Microstruct. Sci. Natl. Res.Counc. Ottawa Ontario Canada K1A OR9). Peignon M. C. Cardinaud C. Turban G. Kinetic study of reactive ion etching of tungsten in sulfur hexafluoride-oxygen radiofrequency plasmas J. Elec- trochern. Soc. 1993 140 505. (Inst. Materiaux-CNRS Univ. Nantes 44072 Nantes France). Kim A. Hill S. Ebdon L. Rowland S. Determination of organometallic compounds by capillary gas chroma- tography-inductively coupled plasma mass spectro- metry J. High Resolut. Chromatogr. 1992 15 665. (Dept. Environ. Sci. Univ. Plymouth Plymouth UK PL4 8AA). Zeng Y. Seeley J. A. Dowling T. M. Uden P. C. Khuhawar M. Y. Element-selective atomic emission detection for capillary GC of metal-containing com- pounds J. High Resolut. Chromatogr. 1992 15 669. (Dept. Chem. Univ. Massachusetts Amherst MA 01003 USA). Sundaram K.B. Grogan A. L. Jr. Seshan S. S. Auger electron spectroscopy and secondary-ion mass spectro- scopy study of interdiffusion in gold-bismuth oxide and aluminum-bismuth oxide thin films J. Mater. Sci. Mater. Electron. 1992 3 257. (Univ. Cent. Florida Orlando FL 328 16 USA). Zhang C. S. Flinn B. J. Norton P. R. Segregation of hydrogen on zirconium (0001) studied by SIMS work function Auger electron spectroscopy and nuclear reac- tion analysis J. Nucl. Mater. 1993 199 231. (Dept. Chem. Univ. West. Ontario London Ontario Canada N6A 5B7). Abe K. Watanabe Y. Determination of silicate in sea- water by inductively coupled plasma atomic emission spectrometry J. Oceanogr. 1992 48 283. (Seikai Natl. Fish. Res. Inst. Nagasaki 850 Japan). Anderson D. L.Cunningham W. C. Alvarez G. H. Multi-element analysis of foods by neutron capture prompt pray activation analysis J. Radioanal. Nucl. Chern. 1992 167 139. (Food Drug Adm. Washington DC 20204 USA). Yusof A. M. Wood A. K. H. Environmental assess- ment of coastal sediments by the elemental ratioing 93/36 16. 93/36 17. 931361 8. 93/36 19. 9313620. 931362 1. 9313622. 9313623. 9313624. 9313625. 9313626. 9 313 62 7. 9313628. 9313629. 9313630. technique J. Radioanal. Nucl. Chem. 1993 167 341. (Dept. Chem. Univ. Teknol. Malaysia Johor Bahru 80990 Malaysia). Rouchaud J. C. Boisseau N. Fedoroff M. Multi- element analysis of aluminium by NAA and ICP-AES J. Radioanal. Nucl. Chem. 1993 175 25. (Cent. Etud. Chim. Met. 94407 Vitry-sur-Seine France). Hall E. S. Murphy E. Determination of sources of lead in tap water by inductively coupled plasma mass spectrometry (ICP-MS) J.Radioanal. Nucl. Chem. 1993 175 129. (Dept. Chem. Rutgers State Univ. New Brunswick NJ 088903 USA). Larsen E. Hansen A. B. Kristensen L. V. Solgaard P. Damsgaard E. Heydorn K. ICP-MS INAA and PIXE analysis of airborne dust samples J. Trace Microprobe Tech. 1992 10 43. (Risoe Natl. Lab. Roskilde DK-4000 Denmark). Owens M. D. Majidi V. Laser plasma desorption ionization mass spectrometry for the analysis of solids J. Trace Microprobe Tech. 1992,10 19 1. (Dept. Chem. Univ. Kentucky Lexington KY 40506 USA). Joseph M. R. Majidi V. Laser-induced plasma atomic emission spectrometry of trace metals using an elec- trothermal atomizer J. Trace Microprobe Tech. 1992 10 207. (Dept.Chem. Univ. Kentucky Lexington KY 40506 USA). Gersch H. U. Wittmaack K. Postionization of sput- tered neutrals by a focused electron beam J. Vac. Sci. Technol. A 1993 11 125. (Inst. Strahlenschutz GSF D-2-8042 Neuherberg Germany). Zhang H.-q. Zhang X.-h. Hou M.-y. Yu A.-m. Duan Y.-x. Jin Q.-h. Equilibrium-pulse introduction of samples with the ultrasonic nebulizer for MIP-AES Jilin Daxue Ziran Kexue Xuebao 1992 2 106. (Dept. Chem. Jilin Univ. Changchun China). Higashi Y. Maruo T. Tanaka T. Homma Y. Depth profiling of arsenic in an aluminium arsenide-gallium arsenide multilayer by a new laser-induced sputtered neutral mass spectrometry system Jpn. J. Appl. Phys. Part I 1993 32 982. (NTT Interdiscipl. Res. Lab. Musashino 180 Japan). Schweiker A. Spatially resolved analysis of micro- particles by secondary mass spectrometry Kernfor- schungszent.Karlsruhe [Ber.] K f l 1992 KfK 4981 86. (Inst. Radiochem. Kernforschungszent. Karlsruhe Karlsruhe Germany). Antonovich V. P. Novoselova M. M. Bezlutskaya I. V. Krasyukov V. N. Effect of fulvic and humic acids on flameless atomic absorption determination of organic mercury forms in natural fresh waters Khim. Tekhnol. Vody 1992 14 899. (A. V. Bogatskii Phys.-Chem. Inst. Odessa Ukraine). Kroik A. A. Extraction-atomic absorption method for determination of indium in wastewater Khim. Tekhnol. Vody 1992 14 903. (Res. Inst. Geol. Univ. Dniepro- petrovsk Dniepropetrovsk Ukraine). Morita M. Analysis of heavy metals by inductively coupled plasma mass spectrometry Kinzoku 1992 62(12) 37.(Natl. Inst. Environ. Stud. Tsukuba 305 Japan). Ringdal O. Olsen S. D. ICP-MS a great development for inorganic analysis Kjemi 1991 51(6) 8 11. (Rogalandsforsk. Norway). Takeo H. Nakanaga T. Wakayama N. Spectroscopic measurements on thermal plasma Koon Gakkaishi 1992 18 207. (Natl. Chem. Lab. Ind. Tsukuba 305 Japan). Riva A Costa N. Dellea R. Galliani G. F. Stani G. Gas chromatography-atomic emission detection (GC-AED) and traditional techniques a comparison,JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 387R 931363 1. 9313632. 931363 3. 9313634. 9313635. 9313636. 9313637. 9313 6 3 8. 9313639. 9313640. 9313641. 9313642 9313643. 9313644. Lab. 2000 1991 5(7) 34. (Dipt. Geochim. AGIP S.p.A. S. Donato Milanese Italy). Chang X.-j. Luo X.-y. Zhan G.-y.Su Z.-x. Sun G.-x. ICP analysis of microamount of antimony(Ir1) and -(v) following enrichment and separation with PAN-3 chelate fibre Lanzhou Daxue Xuebao Ziran Kexueban 1990 26 35. (Dept. Chem. Lanzhou Univ. Lanzhou China). Abuodha J. 0. Z. Nyambok I. O. Petrology geo- chemistry and evaluation of heavy mineral deposits coastal Malindi and Ungama Bay Kenya Mar. Min. 1991 10 337. (Sch. Environ. Stud. Moi Univ. Eldoret Kenya). Din Z. B. Use of aluminium to normalize heavy-metal data from estuarine and coastal sediments of Straits of Melaka Mar. Pollut. Bull. 1992 24 484. (Cent. Mar. Coastal Stud. Univ. Sains Malaysia Penang 1 1800 Malaysia). Dowson P. H. Bubb J. M. Lester J. N. Organotin distribution in sediments and waters of selected east coast estuaries in the UK Mar.Pollut. Bull. 1992 24 492. (Dept. Civ. Eng. Imp. Coll. Sci. Technol. Med. London UK SW7 2BU). Koster C. Kahr M. S. Castoro J. A Wilkins C. L. Fourier-transform mass spectrometry Mass Spectrom. Rev. 1992 11 495. (Dept. Chem. Univ. California Riverside CA 9252 1 USA). Ishiwata K. Shiono M. Kubota K. Yoshino K. Hatazawa J. Ido T. Honda C. Ichihashi M. Mish- ima Y. Unique in vivo assessment of 4-[’OB]borono-~- phenylalanine in tumour tissues for boron neutron capture therapy of malignant melanomas using positron emission tomography and 4-borono-2-[1aF]fluoro-~- phenylalanine Melanoma Res. 1992,2 17 1. (Cyclotron Radioisot. Cent. Tohoku Univ. Japan). Solberg R. Metal determination in plating solutions by atomic absorption and emission techniques Met. Fin- ish.1992 90(10) 54. (North Island Nav. Air Stn. San Diego CA USA). Samuelsson E. Mitchell A. Thermochemistry of mag- nesium in nickel-base alloys. Part I. Determination of thermochemical parameters using the atomic absorp- tion technique Metall. Trans. B 1992 23 791. (Phys. Met. Spec. Met. Corp. New Hartford NY 134 13 USA). Marabini M. A. Passariello B. Barbaro M. Induc- tively coupled plasma mass spectrometry capabilities and applications Microchem. J. 1992 46 302. (1st. Tratt. Miner. CNR 00138 Rome Italy). Astruc M. Pinel R. Astruc A. Determination of tributyltin in sediments by hydride genera- tion-GC-QFAAS Mikrochim. Acta 1992 109 73. (Lab. Chim. Anal. Univ. Pau et des Pays de l’Adour F- 64000 Pau France). Harms U. Determination of methylmercury in organic matrices by gas chromatography-atomic absorption spectrometry Mikrochim.Acta 1992 109 13 1. (Labor Radiooekol. Gewaesser Bundesforschungsanst. fur Fisch. W-2000 Hamburg 55 Germany). Dirkx W. M. R. Van Cleuvenbergen R. J. A. Adams F. C. Speciation of alkyllead compounds by GC-AAS A state of affairs Mikrochim. Acta 1992 109 133. (Dept. Chem. Univ. Antwerp B-26 10 Wilrijk Belgium). Kern M. Perman E. Pavli P. Electron probe micro- analysis of glass fibre optics Mikrochim. Acta Suppl. 1992 12 241. (Inst. Elektron. Vak. Teh. Ljubljana 6 1000 Slovenia). Lees D. G. Johnson D. Use of imaging SIMS in a study of an oxidized cobalt-nickel-chromium-alumi- num-yttrium overlay coating Microsc. Oxid. Proc. Int. Conf.’ Ist 1990 252. (Manchester Mater. Sci. Cent. Univ. Manchester Manchester UK MI 7HS).9313645. 9 313 646. 9313647. 9313648. 9313649. 9313650. 931365 1. 9313652. 93/36 5 3. 93/36 54. 931365 5 . 9 313656. 931365 7. 931365 8. 9313659. Subotic K. M. Pavicevic M. K. Design consideration regarding the use of an accelerator mass spectrometer in ion microanalysis Mikrochim. Acta Suppl. 1992 12 187. (Boris Kidrich Inst. Belgrade Yugoslavia). Lin Y. M. Chen J. S. Chemical analysis of lead zirconate titanate by inductively coupled plasma optical emission spectrometry (ICP-OES) MRL Bull. Rex Dev. 1992 6 63. (Mater. Res. Lab. Ind. Technol. Res. Inst. Hsinchu 3 I0 15 Taiwan). Starkovskaya A. I. Methods for preparation of petro- leum and rock samples for isotope analysis of sulfur Neftepererab. Neftekhim. (Kiev) 199 I 41 62. (Inst. Bioorg.Khim. Neftekhim. Kiev Ukraine). Bombach H. Simplified procedure to determine metal- lic iron in non-metallic products Neue Huette 1992 37 34. (Fachbereich Metall. Werkstoffertigungs- technol. Bergakad. Freiberg 0-9200 Freiberg Ger- many). Yasui M. Kihira T. Ota K. Calcium magnesium and aluminium concentrations in Parkinson’s disease Neurotoxicology 1992 13 593. (Div. Neurol. Dis. Wakayama Med. Coll. Wakayama 640 Japan). Iso S. Itoh M. Hoshino A. Takashima K. Tamura K. Tamura S. Toida Y. Watanabe K. Development of certified reference materials Nippon Genshiryoku Kenkyusho [Rep.] JAERI-M 1992 JAERI-M 92- 036,12. (Inst. Environ. Sci. Japan). Barlow R. D. Dowsett M. G. Fox H. S. Kubiak R. A. A Newstead S. M. SIMS response functions for MBE grown delta layers in silicon Nucl.Instrum. Methods Phys. Res. Sect. B 1992 72 442. (Dept. Phys. Univ. Warwick Coventry UK CV4 7AL). Sabioni A. C. S. Freire F. L. Jr. Leite C. V. B. Amami B. A. D o h C. Monty C. Millot F. Study of oxygen self-diffusion in oxides by ion beam techniques comparison between nuclear reaction analysis and SIMS Nucl. Instrum. Methods Phys. Res. Sect. B 1993 73 85. (Dept. Fis. Univ Fed. Ouro Preto 35400 Ouro Preto Brazil). Thomas E. W. Torabi A. SIMS analysis using ejected CsX+ ions Nucl. Instrum. Methods Phys. Rex Sect. B 1993 73 214. (Sch. Phys. Georgia Tech Atlanta GA 30332 USA). Alton G. D. Ion sources for accelerators in materials research Nucl. Instrum. Methods Phys. Res. Sect. B 1993 73 221. (Oak Ridge Natl. Lab. Oak Ridge TN 37831 USA). Beneteau S. B. Quality control for inductively coupled plasma mass spectrometric data in the Geoscience Laboratories Ont. Geol.Surv. Misc. Pap. 1992 160 153. (Geosci. Lab. Sect. Ontario Geol. Surv. Sudbury Ontario Canada). Gavrilov V. E. Emission spectral line intensity in slightly non-ideal neon plasma Opt. Spektrosk. 1992 73 226. (Gos. Opt. Inst. St. Petersburg Russia). Daolio S. Ajo D. Rossetto G. Aschieri C. Armelao L. Secondary ion mass spectrometric study of thallium oxide thin films grown via metal organic chemical vapour deposition Org. Mass Spectrom. 1992 27 I 17 1. (1st. Polarogr. Elettrochim. Prep. CNR 35 100 Padua Italy). Lees D. G. Johnson D. Investigation of a cobalt- nickel-chromium-aluminium-yttrium overlay coating and its oxidation behaviour by means of imaging SIMS Oxid.Met. 1992 38 217. (Manchester Mater. Sci. Cent. Univ. Manchester Manchester UK M 1 7HS). Manfredi J. F. Pasquini C. De Castro A. H. Collins C. H. Collins K. E. Injector for preparation of flame or plasma spectrophotometer samples Braz. Pedido PI BR 91 04,352 (Cl. G01N30/24) 10 Mar 1992 Appl.388R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 9313660. 9313661. 9313662. 9313663. 9313664. 9313665. 9313666. 9313667. 9313668. 9313669. 9313670. 931367 1. 9313672. 9313673. 91/4,352,03 Oct 1991; 6 pp. (McQdo Brasil Industriae Commercio Brazil). Papp L. Electrothermal andlor hollow cathode com- bined spectroscopic atomizer andlor radiation source for qualitative and quantitative elemental microana- lysis Teljes HU 60,542 (Cl. GO 1 N2 1/74) 28 Sep 1992 Appl.8912,336 10 May 1989; 13 pp. (Kossuth Univ. Debrecen Hungary). Richter H. Transport of calcium ions through a membrane model Pharmuzie 1992 47 947. (Inst. Pharm. Chem. Martin-Luther-Univ. Halle-Wittenberg HalleISaale Germany). Gijbels R. Surface and bulk analysis via SIMS SNMS and GDMS Phys. Mug. 1992 14 49. (Dept. Scheikd. Univ. Instelling Antwerpen B-26 10 Wilrijk-Antwerpen The Netherlands). Greenlief C. M. White J. M. Secondary-ion mass spectroscopy Phys. Methods Chem. (2nd Ed.) 1993,9A 32 1. (Dept. Chem. Univ. Missouri Columbia MO USA). Bollen G. Kluge H. J. Koenig M. Otto T. Savard G. Stolzenberg H. Moore R. B. Rouleau G. Audi G. Resolution of nuclear ground and isomeric states by a Penning trap mass spectrometer Phys. Rev. C. Nucl. Phys.1992 46 R2140. (Inst. Phys. Univ. Mainz D- 6500 Mainz Germany). Bollen G. Hartmann H. Kluge H. J. Koenig M. Otto T. Savard G. Stolzenberg H. Towards a ‘perfect’ Penning trap mass spectrometer for unstable isotopes Phys. Scr. 1992 46 581. (Inst. Phys. Univ. Mainz D- 6500 Mainz Germany). Weber W. M. Stapel C. Orientation effects in the K absorption of linearly polarized synchrotron radiation in a gallium single crystal Phys. Scr. 1993 47 124. (Dept. Phys. Rijksuniv. Groningen 9747 AG Gronin- gen The Netherlands). Preston T. Measurement of stable isotope natural abundance variations Plant Cell Environ. 1992 15 1091. (Scott. Univ. Res. React. Cent. Glasgow UK G75 OQU). Kakhnovich Z. N. Lerner L. A. Kargman V. B. Atomic absorption determination of copper lead chromium cadmium nickel and cobalt in natural waters following preconcentration by sorption on weakly-basic anion-exchanger resin Pochvovedenie 1990 12 122.(Pochen. Inst. im. Dokuchaeva Russia). Maslowska J. Ahmadi M. Determination of toxic elements in molasses and defecation mud using emis- sion method Przem. Spozyw. 1991 45 201. (Inst. Podstaw Chem. Zywn. Politech. Lodzka 90-924 Lodz Poland). Kertes A. S. Zangen M. Schmuckler G. Analytical and other applications of the principle of solvent extraction Princ. Pract. Solvent Extr. 1992 5 1 1. (Hebrew Univ. Jerusalem Jerusalem Israel). Wille P. Jede R. Isotopic abundance in natural iron ASTM-EURATOM Symp. React. Dosmin. 7th 1990 (Pub. 1992) 403. (Inst. Mater. Res. Leybold AG Cologne Germany). Bardwell J. A. Sproule G. I.Graham M. J. Ex situ surface analysis of passive films on iron-chromium alloys-when is it valid? Proc. Electrochem. Soc. 1992 92 195. (Inst. Microstruct. Sci. Natl. Res. Counc. Ottawa Ontario Canada K1A OR9). Slodzian G. Boust F. Daigne B. Girard F. Hillion F. Parallel mapping of several elements or isotopes with a new high sensitivity and high spatial resolution scanning ion microscope Proc. Eur. Conf Adv. Mater. Processes 2nd. 1991 (Pub. 1992) 3 334. (Univ. Paris- Sud 91405 Orsay France). 9313674. 9313675. 9 313 6 7 6. 9313677. 931367 8. 9313679. 9313680. 931368 1. 9313682. 9313683. 9313684. 9313685. 9313686. 9313687. Hibbert S. Humphrey P. Johnson D. Application of quadrupole secondary-ion mass spectrometry (SIMS) in materials analysis Proc. Eur. Conf Adv. Mater.Pro- cesses 2nd 1991 (Pub. 1992) 3 366. (Cent. Surf. Mater. Anal. UMIST Manchester UK). Drabloes P. A. Hetland S. Schmidt F. Thomassen Y. Uptake and excretion of aluminium in workers exposed to aluminium fluoride and aluminium oxide Proc. Int. Conf Alum. Health Znd 1992 157. (Hydro Alum. Ltd. Norway). Kraft S. L. Gavin P. R. DeHaan C. E. Leathers C. W. Bauer W. F. Miller D. L. Dorn R. V. 111 Borocaptate sodium a potential boron delivery com- pound for boron neutron capture therapy evaluated in dogs with spontaneous intracranial tumours Proc. Natl. Acad. Sci. U. S. A . 1992 89 11973. (Coll. Vet. Med. Kansas State Univ. Manhattan KS 66506-0 1 12 USA). Popov V. F. Problems of layer analysis in secondary- ion mass spectrometry Rudiotekh. Elektron. (Moscow) 1992 37 1863.(Russia). Lee-Fatou A. V. Dorozhkin A. A. Kovarsky A. P. Analysis for oxygen in materials by secondary-ion mass spectrometry Radiotekh. Elektron. (Moscow) 1992 37 1870. (Russia). Galiev G. B. Ignatiev A. S. Kopylov V. B. Ryabov Yu E. Secondary mass spectrometry study of the &doped layers in quantum-sized gallium arsenide-aluminium gallium arsenide structures Radiotekh. Elektron. (Mos- cow) 1992 37 19 10. (Russia). Testino S. A. Jr. Busch K. L. Investigation of the precision of isotopic abundances determined by secon- dary-ion mass spectrometry Rapid Commun. Muss Spectrom. 1993 7 25 1. (Sch. Chem. Biochem. Georgia Inst. Technol. Atlanta GA 30332-0400 USA). Muller R. A. Bertsche K. J. Accelerator AMS cyclotrons and cyclotrinos Rare Nucl. Processes Proc. Europhys. ConJ Nucl.Phys. 14th 1990 (Pub. 1992) 93. (Lawrence Berkeley Lab. Univ. California Ber- keley CA 94720 USA). Huang Y.-z. Zheng Q.-h. Liang Z.-q. Determination of trace copper lead zinc cadmium iron and man- ganese in sea-water by ion-exchange atomic absorption spectroscopy Redui Haiyang 1992 11 30. (South China Sea Inst. Oceanol. Acad. Sin. Canton 5 10301 China). Enviromental Monitoring Systems Laboratory Methods for the determination of metals in environmental samples Report 199 1 EPN60014-9 1 I0 10; Order No. PB91-231498 305 pp. (Eng). Avail. NTIS. From Gov. Rep. Announce. Index (U. S.) 1991 91 Abstr. No. 162,094. (Chem. Res. Div. Cincinnati OH USA). Thiel R. D. Inductively coupled plasma atomic emis- sion spectroscopy analysis of gold electroplating solu- tons Report 199 1 RFP-4387; Order No.DE92004798 15 pp. (Eng). Avail. NTIS. From Energy Res. Abstr. 1992 17 Abstr. No. 4172. (Rocky Flats Plant EG and G Rocky Flats Inc. Golden CO USA). Luca C. Pleniceanu M. Muresan N. Nickel(I1) ion- selective electrodes with liquid membrane based on simple and mixed complexes Rev. Roum. Chim. 1992 37 5 5 5 . (Fac. Ind. Chem. Polytech. Inst. Bucharest Bucharest Rumania). Katsuragawa H. Kubota M. Minowa T. Simple and efficient pulsed-heating atomic beam source for reso- nance ionization spectroscopy Rev. Sci. Instrum. 1993 64 265. (Fac. Sci. Toho Univ. Funabashi 274 Japan). Maeda H. Ye D. Kawai J. Suzuki A. Takami M. Surface impurity analysis of high purity materials by laser evaporation-resonance ionization mass spectro- metry Reza Kagaku Kenkyu 1992 14 128.(Riken Wako Japan).JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 389R 9313688. 9313689. 9313690. 931369 I. 9313692. 9313693. 9313694. 9313695. 9 313 696. 9313697. 9313698. 9313699. 9313700. 9313701. Menegon F. Boschelle O. Lercker G. Microwave digestion for the determination of the nickel and copper content of margarine by atomic absorption spectropho- tometry Riv. Ital. Sostanze Grasse 1992 69 509. (1st. Tecnol. Aliment. Univ. Udine Italy). Bordin G. McCourt J. Rodriguez A. Trace metals in the marine bivalve Macoma balthica in the Wester- schelde Estuary (The Netherlands). Part I analysis of total copper cadmium zinc and iron concentrations -1ocational and seasonal variations Sci. Total Envi- ron. 1992 127 255.(Jt. Res. Cent. Comm. Eur. Commun. 2440 Geel Belgium). Benemariya H. Robberecht H. Deelstra H. Zinc copper and selenium in milk and organs of cow and goat from Burundi Africa Sci. Total Environ. 1993 128 83. (Dept. Pharm. Sci. Univ. Antwerp B-2610 Wilrijk Belgium). Moya F. Moya E. G. Juve D. Treheux D. Gratte- pain C. Aucouturier M. SIMS study of copper diffu- sion into bulk alumina Scr. Metall. Muter. 1993 28 343. (Lab. Metall. Fac. St. Jerome 13397 Marseille France). Cherepin V. T. Chichkan S. M. Kosyachkov A. A. Direct recoils of hydrogen and secondary-ion emission from niobium surfaces Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 199 1,37. (Inst. Met. Phys. Kiev 252680 Ukraine). Kosyachkov A. A. Hydrogen enhanced secondary-ion emission from metal surfaces Second.Ion Mass Spec- trom. SIMS8 Proc. Int. Con$ 8th 1991,41. (Inst. Met. Phys. Kiev 252680 Ukraine). Cha L.-z. Lin W.-d. Jiang Z.-x. Tong Y.-q. Mo 2.-q. Zou Q.-s. Oxygen effect on positive secondary- ion emission from gallium arsenide under argon( 1 +) bombardment Second. Ion Mass Spectrom. SIMS 8 Proc. Int. ConJ 8th 1991 53. (Dept. Electron. Eng. Tsinghua Univ. Beijing 100084 China). Bennett J. Simons D. Factors influencing quantitative SIMS using a microfocused gallium ion beam and TOF- MS Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con& 8th 1991 123. (Surf. Microanal. Sci. Div. Natl. Inst. Stand. Technol. Gaithersburg MD 20899 USA). Fox H. S. Dowsett M. G. Barlow R. D. Sykes D. E. Chew A. Kilner J. A Bhan M. K. Hill C. Ion implanted standards in silicon influence of the material state Second.Ion Mass Spectrom. SIMS 8 Proc. Int. Conf 8th 1991 131. (Dept. Phys. Univ. Warwick Coventry UK CV4 7AL). Canteri R. Moro L. Anderle M. Matrix effects and quantitative analysis in silicon effects in the presence of localized reactive species Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 135. (Div. Sci. Mater. IRST 38050 Povo Italy). Tanigaki T. Hirano T. Quantitative determination of the ultra-shallow doping impurities in silicon by SIMS Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 139. (Process Technol. Div. Sony Corp. Atsugi 243 Japan). Smith S. P. Landstrass M. I. Wilson R. G. SIMS of CVD diamond films and natural crystal diamonds Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 199 1 159.(Charles Evans Assoc. Redwood City CA 94063 USA). Chia V. K. F. Bleiler R. J. Sams D. B. Odom R. W. Microvolume SIMS quantification of sulfur in ultra- pure hydrochloric acid Second. Ion Mass Spectrom. SIMS 8 Proc. Znt. Con$ 8th 199 1 163. (Charles Evans Assoc. Redwood City CA 94063 USA). Blackmore G. W. Giess J. Astles M. G. Shaw N. Gough J. S. Young M. L. SIMS analysis of sodium in cadmium mercury telluride grown on gallium arsenide Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 9 313 702. 9313703. 9 313 704. 9313705. 9313706. 9313707. 9313708. 9313709. 93/37 10. 93/37 1 1. 93/37 12. 93/37 13. 93/37 14. 93/3715. 93/37 16. 8th 1991 467. (Def. Res. Agency RSRE Malvernl Worcestershire UK WR 14 3PS). Newman J. G. Presson W. W. Static SIMS analysis of rigid magnetic disc contact startlstop tracks Second.Ion Mass Spectrom. SIMS 8 Proc. Int. Con&. 8th 1991 761. (Evans Cent. Minnetonka MN 55345 USA). Biczo I. Josepovits V. K. Strublik S. Giber J. SIMS study of magneto-optical information storage layer Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$. 8th 1991 777. (Dept. At. Phys. Tech. Univ. Budapest Hungary). Homma Y. Yamawaki M. Igo A. Ochiai S. Stability of relative sensitivity factors in secondary-ion mass spectrometry Shitsuryo Bunseki 1992 40 2 17. (Inter- discip. Res. Lab. NTT Musashino 180 Japan). Xia Y.-y. Zhu D. Determination of 11 mineral and trace elements in foods by ICP-AES Shipin Yu Fajiao Gongye 1992 5 63. (Dept. Commodity Sci. People’s Univ. China Beijing China). Zhang Z. Simultaneous determination of sulfur and phosphorus in petroleum and its product by ICP-AES Shiyou Lianzhi 1992 7 44.(Res. Inst. Pet. Process. Beijing China). Ye Y.-q. Huang S.-y. Liu J.-j. Chen Y. Studies on sample pre-treatment and determination of trace ele- ments in antitumour Chinese medicines by atomic emission spectrometry Sichuan Daxue Xuebao Ziran Kexueban 1992,29 259. (Dept. Chem. Sichuan Univ. Chengdu China). Ismail S. S. Grass F. Arifien A. E. Mostafa A. G. Trace and toxic elements profile in roadside dust by INNA ICP-AES and AAS Sohag Pure Appl. Sci. Bull. 1991 7 16. (Dept. Chem. Fac. Sci. Aswan Egypt). Marino F. Ligero A. Dim Cosin D. J. Heavy metals and earthworms on the border of a road next to Santiago (Galicia northwest of Spain). Initial results Soil Biol.Biochem. 1992 24 1705. (Fac. Biol. Univ. Santiago Santiago 15706 Spain). Chater R. J. Carter S. Kilner J. A. Steele B. C. H. Development of a novel SIMS technique for oxygen self- diffusion and surface exchange coefficient measure- ments in oxides of high diffusivity Solid State Ionics 1992,53-56 (Pt. 2) 859. (Imp. Coll. Sci. Technol. Med. London UK SW7 2BP). Lites B. W. Polarization properties of iron Fe II 6 14.9 nm Sol. Phys. 1993 143 229. (High Altitude Obs. Natl. Cent. Atmosph. Res. Boulder CO USA). Cindrella L. Sooriamoorthi C. E. John S. Improved nickel based alloy coating for solar thermal applications Sol. World Congr. Proc. Bienn. Congr. Int. Sol. Energy SOC. 1991 2(Pt. l) 1154. (Sch. Energy Sci. Madurai Kamaraj Univ. Madurai 625 021 India). Moenke-Blankenburg L.Laser-ICP-spectrometry Spectrochim. Actu Rev. 1993 15 I. (Inst. Anal. Chem. Martin-Luther-Univ. 0-4050 Halle Germany). Swift R. P. Campbell J. E. Atomic fluorescence-based method for ultratrace mercury detection in environmen- tal samples Spectroscopy (Eugene Oreg.) 1993 8 38 40 46. (ICF Kaiser Eng. Port Orchard WA 98366 USA). Berdea P. Cuna C. Feurdean V. Buza A. Bot A. Pirtoc N. SMAD-2A mass spectrometer for isotopic analysis of water Stud. Cercet. Fiz. 1992,44,407. (Inst. Tehnol. hot. Mol. R-3400 Cluj-Napoca Rumania). Terhorst M. Miillers R. Niehuis E. Benninghoven A. High-spatial-resolution surface imaging of inorganic and organic structures by multiphoton post-ionization of sputtered neutrals and time-of-flight mass spectrome- try Surx Inteflace Anal.1992 18 824. (Phys. Inst. Univ. Munster D-4400 Miinster Germany).390R 931 37 17. 93/37 18. 93/37 19. 931 3720. 9313721. 9313722. 931 3723. 9313 724. 9313725. 931 3726. 9313727. 9 31 3 728. 9313729. 9313730. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Downey S. W. Emerson A. B. Sputtering effects in silicon silica and the Si-Si02 interface Surf Interface Anal. 1993 20 53. (AT and T Bell Lab. Murray Hill NJ 07974 USA). Houlton M. R. Blackmore G. W. Emeny M. T. Whitehouse C. R. Chew A. Sykes D. E. SIMS depth resolution studies in aluminium gallium arsenide using specially grown MBE samples Surf Interface Anal. 1993 20 69. (DRA Malvern Worcs UK WR 14 3PS). Bourgeois S. Jomard F. Perdereau M. Use of isotopic labelling in a SIMS study of the hydroxylation of titania( 100) surfaces Sur- Sci.1992 279(3) 349. (Lab. Rech. React. Solides Fac. Sci. Mirande B.P. 138 2 1004 Dijon France). van der Heide P. A. W. Metson J. B. Tui D. L. Lau W. M. Production of heavy multiply charged ions in secondary-ion mass spectrometry Surf Sci. 1993,280 208. (Dept. Chem. Res. Cent. Surf. and Mater. Sci. Univ. Auckland Priv. Bag Auckland New Zealand). Soriano L. Abbate M. Fuggle J. C. Jimenez C. Sanz J. M. Galan L. Mythen C. Padmore H. A. Inter- action of nitrogen with titanium studied by soft X-ray absorption spectroscopy adsorption versus implanta- tion Surf Sci. 1993 281 120. (Spectrosc. of Solids and Surf. Univ. Nijmegen Toernooiveld 6525 ED Nijme- gen The Netherlands). Larson S. A. Lauderback L. L. Oxidation kinetics of the top atomic layer of aluminium( 100) from angle resolved SIMS Sur$ Sci.1993 284 I. (Dept. Chem. Eng. Univ. Nebraska Lincoln NE 68588-0126 USA). Soedervall U. Adriaens A. Lodding A. Odelius H. Engstroem E. U. Adams F. SIMS measurements of isotope ratios; influence of instrumental variables Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 81. (Dept. Phys. Chalmers Univ. Techno]. S-4 1296 Goeteborg Sweden). Gnaser H. Oechsner H. Analytical applicability and formation of MCs+ secondary ions Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 95. (Dept. Phys. Univ. Kaiserslautern W-6750 Kaisers- lautern Germany). Bleiler R. J. Huneke J. C. SIMS determination of oxygen and nitrogen in niobium- 1 To zirconium samples using CsO+ and CsN+ secondary ions Second.Ion Mass Spectrom. SIMS 8 Proc. Int. Conj 8th 1991 103. (Charles Evans Assoc. Redwood City CA 94063 USA). Patel S. B. Kilner J. A. Quantification of the oxygen distribution in SIMOX substrates using xenon( +) caesium( +) and dinitrogen( +) primary beams Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf. 8th 199 1 107. (Dept. Mater. Imp. Coll. Sci. Technol. Med. London UK SW7 2BP). Collins R. Dowsett M. G. Allen P. N. Deconvolution of concentration profiles from SIMS data using mea- sured response functions Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 I 1 1. (Dept. Phys. Univ. York Heslington York UK YO1 5DD). Stephan T. Statistical analysis of single-ion counting data and isotopic measurements with TOF-SIMS Sec- ond. Ion Mass Spectrom.SIMS 8 Proc. Int. Conf. 8th 1991 115. (Phys. Inst. Univ. Munster D-4400 Mun- ster Germany). Sharma V. K. M. Ferguson I. T. Kilner J. A. McPhail D. S. SIMS study of silicon doping in indium arsenide Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 143. (Dept. Mater. Imp. Coll. London UK). Littlewood S. D. Biswas S. Calibration of oxygen in silicon a quantitative SIMS method for the high concentration regime up to silica level Second. Ion 9313731. 931 31 32. 931 3733. 9313734. 931 3735. 9313736. 9 31 37 37. 931 3738. 931 3739. 931 3740. 931374 1. 9313742. 931 3743. Mass Spectrom. SIMS 8 Proc. Int. Cont 8th 1991 155. (Brunel Univ. Uxbridge UK). Slodzian G. Daigne B. Girard F. Boust F. Hillion F. High resolution scanning ion microscope with parallel detection of secondary ions Second. Ion Mass Spectrom..SIMS 8 Proc. Int. Con$ 8th 1991 169. (Lab. Phys. Solides Univ. Paris-Sud 9 1405 Orsay France). Chabala J. M. Levi-Setti R. Li J. Parker N. W. Utlaut M. Development of a magnetic sector-based high lateral resolution scanning ion microprobe Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 199 1 179. (Enrico Fermi Inst. Univ. Chicago Chicago IL 60637 USA). Thompson S. P. Dowsett M. G. Wilkes J. L. Fairley N. A. Corlett C. A. Nuttall J. Finbow D. Griffiths B. W. Blenkinsop P. Mullock S. J. New magnetic sector SIMS instrument-the Kratos S 1030 Second. Ion Muss Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 183. (Kratos Anal. Ltd. Manchester UK M3 1 2LD). Migeon H. N. Rasser B. Schuhmacher M. LeGoux J. J. CAMECA IMS 5F an automated SIMS instru- ment with optimized ion microscope and ion micro- probe modes Second.Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 195. (CAMECA 92400 Courbevoie France). Thorne N. A. Degreve F. Beam position control for an IMS 3f ion microscope ion microprobe performance and automatic centring Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conj 8th 1991 203. (Cent. Rech. Pechiney 38340 Voreppe France). Wittmaack K. ATOMIKA SIMS 4000 a new dual- beam ion microprobe for spatially resolved depth profiling Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 21 1. (ATOMIKA Analysetech. GmbH D-8042 Oberschieissheim Germany). Shichi H. Umemura K. Nomura S. Micro-area element analysis using caesium-LMIS incorporating SEMISIMS Second. Ion Mass Spectrom.SIMS 8 Proc. Int. Con$ 8th 1991 259. (Cent. Res. Lab. Hitachi Kokubunji 185 Japan). Phillips B. F. Mitchell D. F. High resolution SIMS imaging for materials analysis problem solving Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 199 I 263. (Philcraft Assoc. Bloomington MN 55437 USA). Jiirgens U. Cramer H. G. Heller T. Niehuis E. Zhang Z.-y. Benninghoven A. Ultra-trace detection of metal contamination on wafer surfaces Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 277. (Phys. Inst. Univ. Munster D-4400 Munster Germany). Schueler B. Odom R. W. Chakel J. A. Surface contamination analysis of semiconductors by time-of- flight SIMS Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 281. (Charles Evans Assoc. Redwood City CA 94063 USA).King B. V. Webb R. P. Sharma V. K. M. Kilner J. A. SIMS measurements of ion beam mixing in silver Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 1991 363. (Dept. Electron. Electr. Eng. Univ. Surrey Guildford UK GU2 5XH). Petravic M. Elliman R. G. Williams J. S. Recoil mixing in SIMS profiling of thin buried layers Second. Ion Mass Spectrom. SIMS 8 Proc. Int. ConJ 8th 199 1 367. (Res. Sch. Phys. Sci. Eng. Aust. Natl. Univ. Canberra 260 1 Australia). Miethe K. Round robin study of the German SIMS users forum part 1 carbon in gallium arsenide Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Con$ 8th 199 1 399. (Res. Inst. Dtsch. Bundespost Telekom W-6 100 Darmstadt Germany).JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 391R 9313744. 9313745.9313746. 9313747. 9313748. 9313749. 9313750. 93/375 1. 9313752. 9 313 7 5 3. 9313754. 9313755. 9313 7 56. 931375 7. Von Criegern R. Round robin study of the German SIMS users forum. Part 11 oxygen in silicon Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf. 8th 199 I 403. (Siemens AG D-8000 Munich 83 Germany). Likonen J. Hautala M. SIMS- and NRA-measure- ments of depth profiles of implanted ions Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 415. (React. Lab. Tech. Res. Cent. Finland SF-02150 Espoo Finland). Miwa S. Ishikawa H. Nomachi I. Maruyama T. Application of encapsulation to assess contamination on indium phosphide wafers Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 427. (Res. Cent. Sony Corp. Yokohama Japan). Wangemann K.Improvements concerning the detec- tion limit of phosphorus in silicon applying a new background subtraction technique Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 447. (Siemens AG D8000 Munich 83 Germany). Novak S. W. Matthews P. Young W. Wilson R. G. SIMS depth profile measurements of hydrogen lithium neodymium and erbium in lithium niobate (LiNb03) and lithium tantalate (LiTa03) Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 471. (Evans East Plainsboro NJ 08536 USA). Wilson R. G. Stevie F. A. Kahora P. M. SIMS depth profiling and relative sensitivity factorslrelative ion yields and systematics for elements from hydrogen to uranium implanted to metal matrices (beryllium alumi- nium titanium nickel tungsten and gold) Second. Ion Mass Spectrom.SIMS 8 Proc. Int. Conf.’ 8th 1991 487. (Hughes Res. Lab. Malibu CA 90265 USA). Gauneau M. Chaplain R. Bayon J. F. Rupert A. Salvi M. Three-dimensional analysis of rare earth doped preforms and optical fibres radial distribution of dopants and quantification Second. Ion Mass Spec- trom. SIMS 8 Proc. Int. Conf 8th 1991 521. (LABIOCM Cent. Natl. Etud. Telecommun. 2230 1 Lannion France). Gara S. Stingeder G. Tian C. Hutter H. Fuehrer H. Grasserbauer M. Characterization of oxygen precipi- tates by imaging SIMS Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf 8th 1991 537. (Inst. Anal. Chem. Tech. Univ. Vienna A-I060 Vienna Austria). Hayashi S. Hashiguchi Y. Quantitative trace analysis by non-resonant laser post-ionization SNMS Second. Ion Mass Spectrom. SIMS 8 Proc.Int. Conf.’ 8th 199 I 575. (Adv. Mater. Technol. Res. Lab. Nippon Steel Corp. Kawasaki 2 1 1 Japan). Brusatin G. Camera A. SIMS-RBS combined use for quantitative complex systems analysis Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 61 3. (Dipt. Fis. G. Galilei 35 13 1 Padua Italy). Van Straaten M. Butaye L. Gijbels R. Depth profil- ing of coated steel wires by GDMS Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 629. (Dept. Chem. Univ. Antwerp B-26 10 Wilrijk Bel- gium). Frost M. R. Gupta P. Davies P. W. Quantitation of impurities near the surface of silicon wafers using SIMS comparison to TXRF and VPD-AAS Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 637. (Intel Corp. Santa Clara CA 9505 1 USA). Briancon C.Jeusset J. Halpern S. Fragu P. SIMS microscopy evaluation of exchangeable and total organi- fied iodine metabolism within thyroid follicle choice of a tracer Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 697. (Equipe Microsc. Ionique Inst. Gustave-Roussy 94800 Villejuif France). Simons D. S. SIMS analysis of fused clay micro- spheres containing plutonium Second. Ion Mass Spec- trom. SIMS 8 Proc. Int. Conf.’. 8th 1991 715. (Surf. 9 313 7 5 8. 9313759. 9313760. 931376 1. 9313762. 9313 763. 9313764. 931376 5. 9313766. 9313767. 9313 7 68. 9313769. 9 313 7 70. Microanal. Sci. Div. Natl. Inst. Stand. Technol. Gaith- ersburg MD 20899 USA). Kataoka Y. Suzuki K. Three-dimensional SIMS study of impurity diffusion in tungsten silicide Second. Ion Mass Spectrom.SIMS 8 Proc. Int. Conf.’ 8th 1991 84 I. (Fujitsu Lab. Atsugi 243-0 1 Japan). Tian C. Gara S. Hobler G. Stingeder G. Mapping of boron-channelling by SIMS Second. Ion Mass Spec- trom. SIMS 8 Proc. Int. Conf.’ 8th 1991 845. (Inst. Anal. Chem. Tech. Univ. Vienna A-1060 Vienna Austria). Cooke G. A. Dowsett M. G. Hill C. Pearson P. High resolution high sensitivity two dimensional profiling of boron and arsenic implants in silicon Second. Ion Mass Spectrom. SIMS 8 Proc. Int. Conf.’ 8th 1991 861. (Adv. SIMS Proj. Univ. Warwick Coventry UK CV4 7AL). Maier M. As D. J. Koehler K. Hiipner A. Composi- tional analysis of MBE pseudomorphic indium gallium arsenide-aluminium gallium arsenide-gallium arsenide structures by determination of film thickness with SIMS Second. Ion Mass Spectrom.SIMS 8 Proc. Int. Conf.’ 8th 1991 873. (Fraunhofer-Inst. Angew. Festko- erperphys. D-7800 Freiburg Germany). Glasper J. L. Robbins D. J. Leong W. Y. Armour D. G. Badheka R. Wadsworth M. In-situ SIMS studies of silicon germanium (Si -xGe,) Second. Ion Mass Spec- trom. SIMS 8 Proc. Int. Conf.’ 8th 1991 893. (Def. Res. Agency RSRE Malvern UK WR I4 3PS). Inamoto I. Chiba K. Determination of magnesium copper zinc silver and lead in pure iron by isotope dilution analysis-inductively coupled plasma mass spectrometry Tetsu to Hagane 1993 79 175. (Adv. Mater. Technol. Res. Lab. Nippon Steel Corp. Kawa- saki 2 1 1 Japan). Kloprogge J. T. Geus J. W. Jansen J. B. H. Seykens D. Thermal stability of basic aluminium sulfate Ther- mochim. Acta 1992 209 265. (Inst.Earth Sci. Univ. Utrecht 3508 TA Utrecht The Netherlands). Cirlin E. H. Auger electron spectroscopy and secon- dary-ion mass spectrometry depth profiling with sample rotation Thin Solid Films 1992 220 197. (Hughes Res. Lab. Malibu CA 90265 USA). Durrant S. F. Mota R. P. De Moraes M. A. B. Fluorinated polymer films from r.f. plasmas containing benzene and sulfur hexafluorine Thin Solid Films 1992 220 295. (Inst. Fis. ‘Gleb Wataghin’ Univ. Estadual Campinas Campinas Brazil). Kriiger D. Kurps R. Osten H. J. Lippert G. Roeser D. Characterization of surfactant introduction into germanium-rich silicon-germanium molecular beam epitaxy layer growth on silicon by means of secondary- ion mass spectrometry and Auger electron spectro- scopy Thin Solid Films 1992 221,6 1. (Inst.Semicond. Phys. 0-1 200 Frankfurt Oder Germany). Deng 2.-g. Measurements of uranium concentrations in irradiated fuels by isotopic dilution mass spectrome- try Tongweisu 1992 5( I) 8. (China Inst. At. Energy Beijing 1024 13 China). Tohnan M. Tabata T. Okada T. Analysis for ultra- trace impurities in zirconium oxide by inductively coupled plasma mass spectrometry Toso Kenkyu Hok- oku 1993 37 27. (Tosoh Corp. Tokyo Japan). Tothill P. Matheson L. M. McKay K. Smyth J. F. Inductively coupled plasma source mass spectrometry for the determination of platinum in animal tissues Trace Elem. Man Anim. 7 Monogr. Proc. Round Tables Discuss. Int. Symp. 7th 1990 (Pub. 199 I) 1612. (Imp. Cancer Res. Found Med. Oncol. Unit West. Gen. Hosp. Edinburgh UK EH4 2XU).392R 931377 1.9313772. 9313773. 9313774. 9313775. 9313776. 9313777. 931377 8. 9313779. 9313780 931378 1. 9313782. 9313783. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Abou-Shakra F. R. Ward N. I. Determination of lithium in blood serum by inductively coupled plasma mass spectrometry Trace Elem. Man Anim. 7 Monogr. Proc. Round Tables Discuss. Int. Symp. 7th 1990 (Pub. 1991) 16/4. (Dept. Chem. Univ. Surrey Guildford Surrey UK GU2 5XH). Winter L. C. Inductively coupled plasma mass spectro- metry-its place in human bone analysis Trace Elem. Man Anim. 7 Monogr. Proc. Round Tables Discuss. Int. Symp.. 7th 1990 (Pub. 1991) 3312. (Dept. Anthro- pol. Univ. Durham UK). Ward N. I. Abou-Shakra F. R. Durrant S. F. Thompson J. Havercroft J. M. Yadegarin L. Induc- tively coupled plasma mass spectrometry (ICP-MS) in biological studies for multi-element analysis and isotope ratios Trace Elem. Man Anim.7 Monogr. Proc. Round Tables Discuss. Int. Symp. 7th 1990 (Pub. 1991) 3315. (Dept. Chem. Univ. Surrey Guildford Surrey UK GU2 5XH). Thompson J. Ward N. I. Gooddy W. Elemental analysis of cerebrospinal fluid (CSF) by inductively coupled plasma mass spectrometry (ICP-MS) Trace Elem. Man Anim. 7 Monogr. Proc. Round Tables Discuss. Int. Symp. 7th 1990 (Pub. 1991) 3317. (Dept. Chem. Univ. Surrey Guildford Surrey UK GU2 5XH). Johansson E. Westermarck T. Liljefors T. Elemental profiles of pharmaceuticals tablets by ICP-MS Trace Elem. Man Anim. 7 Monogr. Proc. Round Tables Discuss. Int. Symp. 7th 1990 (Pub. 1991) 3319. (Div. Phys. Biol.Dept. Radiat. Sci. 751 21 Uppsala Sweden). Soltani-Neshan M. A. Dorner K. Schaub J. Determi- nation of isotope ratios of molybdenum by chelate gas chromatography-mass spectroscopy for bioavailability studies Trace Elem. Man Anim. 7 Monogr. Proc. Round Tables Discuss. Int. Symp. 7th 1990 (Pub. 1991) 33110. (Univ. Child. Hosp. 2300 Gel 1 Ger- many). Alcock N. W. Ramanujam V. M. S. Blood lead determined by inductively coupled plasma mass spec- trometry Trace Elem. Man Anim. 7 Monogr. Proc. Round Tables Discuss. Int. Symp. 7th 1990 (Pub. 199 I) 331 14. (Med. Branch Univ. Texas Galveston TX 77550 USA). Arnaud J. Chappuis P. Zawislak R. Houot O. Comparison of serum zinc determination by colorime- tric and atomic absorption methods in four different laboratories Trace Elem.Med. 1992 9 198. (Lab. Biochim. C CHRUG F-38043 Grenoble France). Thiem T. L. Lee Y. 111 Sneddon J. Recent advances in the field of laser atomic spectroscopy Trends Anal. Chem. 1993 12 18. (Hamscom Air Force Base MA 0 173 1 USA). Agganval S. K. Jain H. C. Plutonium determination by isotope dilution technique with mass and alpha spectrometry Transuranium Elem. Symp. 1990 (Pub. 1992) 126. (Fuel Chem. Div. Bhabha At. Res. Cent. Bombay 400 085 India). Trautmann N. Detection and speciation of trace amounts of neptunium and plutonium Transuranium Elem. Symp. 1990 (Pub. 1992) 159. (Inst. Kernchem. Univ. Mainz D-6500 Mainz Germany). Leisch M. Surface analysis of dielectric films by time- of-flight secondary-ion mass spectrometry Vucuum 1992,43(5-7) 48 1. (Inst. Festkoerperphys.Tech. Univ. Graz A-80 10 Graz Austria). Burba P. Bloedorn W. Off/on-line pre-enrichment of heavy metals by chelating ion exchangers. Parameters and risks Vom Wasser 1992 79 9. (Inst. Spektrochem. Angew. Spektrosk. W-4600 Dortmund 1 Germany). 9313784. 931378 5. 9313786. 9313787. 9313788. 9313789. 9313790. 931379 1. 9313792. 9313793. 9313794. 9313795. 9 313 796. 9313797. 9313798. 9313799. Hintelmann H. Ebinghaus R. Wilken R. D. Accumu- lation of mercury(n) and methylmercury by microbial biofilms Water Res. 1993,27,237. (Inst. Chem. GKSS Res. Cent. W-2054 Geesthacht Germany). Yamasaki S. Tsumura A. Determination of ultra-trace levels of elements in water by high resolution ICP-MS with an ultrasonic nebulizer Water Sci. Technol. 1992 25 205. (Natl. Inst. Agr-Environ.Sci. Tsukuba 305 Japan). Park J. H. Kim H. J. Determination of trace elements in animal feed by inductively coupled plasma mass spectrometry Yakhak Hoechi 1992 36 199. (Coll. Pharm. DongDuck Women’s Univ. Seoul 136-7 14 South Korea). Shao Y.-b. Application of ICP-MS to elemental analy- sis Yankuang Ceshi 1992 11( 1-2) 24. (Inst. Geophys. Geochem. Explor. Hebei 102849 China). Ma W.-y. Li L.-q. Zhao W.-z. Chen D.-y. Measure- ment of autoionization states and highly sensitive analysis for ruthenium Yuanzi Yu Fenzi Wuli Xuebao 1992 9 2346. (Dept. Phys. Tsinghua Univ. Beijing 100084 China). Jiang S. Jiang S.-s. Wang X. Ma T.-j. Gas ionization chamber for identification of isobars in accelerator mass spectrometry Yuanzineng Kexue Jishu 1991 25(3) 40. (China Inst. At.Energy Beijing China). Shuqin G. Deng Z.-g. Che Z.4 Determination of isotopic abundance ratio and content for reactor pins Yuanzineng Kexue Jishu 1991 25(3) 45 61. (China Inst. At. Energy Beijing China). Li S.-I. Hou S.-b. Determination of trace uranium in soil by isotope dilution mass spectrometry Yuanzineng Kexue Jishu 1991 25(3) 68. (China Inst. At. Energy Beijing China). Jiang S.-s. Ma T.-j. Jiang S. Li Y.-h. Yu J.-h. Accelerator mass spectrometer electrostatic deflector Yuanzineng Ke.xue Jishu 199 1 25(4) 29. (China Inst. At. Energy Beijing China). Gu G.-y. She M.-j. Li J.-y. Analysis of simulated waste vitrification glass specimens by ICP-AES Yuanzi- neng Kexue Jishu 1991 25(6) 15. (China Inst. At. Energy Beijing China). Mizobuchi M. Saito K.Application of ultrasonic nebulizer to ICP-AES instead of conventional cross-flow nebulizer Zenkoku Kogaiken Kaishi 1992 17 133. (Nara Prefect. Inst. Public Health Nara Japan). Drobyshev A. I. Analysis of the layer-by-layer distribu- tion of elements in the corrosion damage zone of titanium-aluminium alloy by the atomic emission spectroscopy method with a cooled hollow cathode Zh. Prikl. Spektrosk. 1992 57 438. (St. Petersburg Univ. Russia). Karpov Yu. A. Analysis of high-purity materials Zh. Anal. Khim. 1992 47 1572. (State Sci. Res. Des. Inst. Rare Met. Ind. Moscow Russia). Bavdaz M. Gurker N. Coded imaging X-ray micro- probe X-ray Spectrom. 1993 22 65. (European Space Agency ESTEC SSD SA P.O. Box 299 NL-2200 AG Noordwijk The Netherlands). Eastell J. Willis J.P. Low dilution fusion technique for the analysis of geological samples. 2. Major and minor element analysis and the use of influencelalpha coefficients X-ray Spectrom. 1993 22 7 1. (Geochem. Dept. Univ. Cape Town Private Bag Rondebosch 7700 South Africa). Wegrzynek D. Holynska B. Pilarski T. Fundamental parameter method for energy-dispersive X-ray fluores- cence analysis of intermediate thickness samples with the use of monochromatic excitation X-ray Spectrom.,JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 393R 9313800. 931380 I . 9 313 8 02. 9313803. 9313804. 9313805. 9313806. 9313807. 9313808. 9313809. 93138 10. 93138 I 1. 93138 12. 93/38 13. 1993 22 80. (Inst. Phys. Nucl. Tech. Acad. Mining Metall. Al. Mickiewicza 30 30-059 Krakow Poland).Sanchez H. J. Rubio M. Determination of wT using the tilt of the propagation plane X-ray Spectrom. 1993 22 89. (Fac. Matem. Astron. Fis. Univ. Nacl. Cordoba Laprida 854 CP 5000 Cbrdoba Argentina). Couture R. A. Sample transparency effects in tin determination by X-ray fluorescence X-ray Spectrom. 1993 22 92. (Dept. Earth Planetary Sci. Washington Univ. St. Louis 1 Brookings Dr. Box 1169 St. Louis Missouri 63 130 USA). Jordanov J. Tsanov T. Stefanov R. Yordanov N. Ortner H. Wilhartitz P. Jenul R. Problems of automated qualitative X-ray fluorescence analysis. 3. Element selection X-ray Spectrom. 1993 22 97. (Bulgarian Acad. Sci. Inst. General Inorg. Chem. BG- 1040 Sofia Bulgaria). Verkhovodov P. A. X-ray fluorescence line intensity expressions for the real divergence beam of an X-ray tube X-ray Spectrom.1993 22 103. (Inst. Mater. Sci. Problems Ukrainian Acad. Sci. 3 Krzhizhanovsky St. Kiev 252680 The Ukraine). Longerich H. P. Application of a new treated LiF200 crystal to X-ray fluorescence analysis of geological samples X-ray Spectrom. 1993 22 114. (Dept. Earth Sci. Centre Earth Resources Res. Memorial Univ. Newfoundland St. John’s Newfoundland Canada Al B 3x5). Kerur B. R. Thontadarya S. R. Hanumaiah B. X-ray attenuation coefficients at 6.46 keV and the validity of the mixture rule for compounds X-ray Spectrom. 1993 22 13. (Dept. Phys. Karnatak Univ. Dharwad-580 003 Karnataka State India). Bui C. Milazzo M. Sironi C. Simplified mathema- tical approach to XRF secondary excitation X-ray Spectrom. 1993 22 17. (Sezione Fis.Atom. 1st Fis. Gen. Appl. Univ. Studi Milano Milan Italy). Moore L. V. Characterization of environmental dusts by X-ray fluorescence spectrometry using a microbead presentation X-ray Spectrom. 1993 22 28. (Tech. Serv. Dept. Pretoria Portland Cement P.O. Box 40073 Cleveland 2022 South Africa). de Boer D. K. G. Borstrok J. J. M. Leenaers A. J. G. van Sprang H. A. Brouwer P. N. How accurate is the fundamental parameter approach? XRF analysis of bulk and multilayer samples X-ray Spectrom. 1993 22 33. (Philips Res. Lab. PO Box 80000 5600 JA Eindhoven The Netherlands). Valdri? G. Collimated and windowless X-ray micro- fluorescence analysis in a scanning electron microscope X-ray Spectrom. 1993 22 39. (Dept. Mineralog. Sci. Piazza Porta S. Donato 1 1-40126 Bologna Italy).Giauque R. D. Asaro F. Stross F. H. Hester T. R. High-precision non-destructive X-ray fluorescence method applicable to establishing the provenance of obsidian artifacts X-ray Spectrom. 1993 22 44. (Lawrence Berkeley Lab. Univ. California Berkeley CA 94720 USA). Lankosz M. Holynska B. Pella P. A. Experimental verification of a Monte Carlo method for X-ray mi- crofluorescence analysis of small particles X-ray Spec- trom. 1993,22 54. (Inst. Phys. Nucl. Techniques Acad. Mining Metall. Mickiewicza 30 Krakow Poland). Short M. A Bonner E. J. Stephenson K. J. Fast X- ray counting system X-ray Spectrom. 1993 22 58. (SRS Technol. 17252 Armstrong Ave. Irvine CA 92714 USA). Dos Santos J. M. F. Bento A. C. S. S. Conde C. A. N. Simple inexpensive gas proportional scintillation coun- ter for X-ray fluorescence analysis X-ray Spectrom.93/38 14. 93138 15. 9313816. Presen red 1993 22 000. (Univ. Coimbra P-3000 Coimbra Portugal). dos Santos J. M. F. Conde C. A. N. Bento A. C. S. S. M. Energy linearity of gaseous xenon radiation detec- tors for X-rays with energies between 2 and 60 keV experimental results Nucl. Instrum. Methods Phys. Rex 1993 A324 61 1. (Phys. Dept. Univ. Coimbra P-3000 Coimbra Portugal). Garg R. R. Puri S. Singh S. Mehta D. Shahi J. S. Garg M. L. Nirmal Singh Mangal P. C. Trehan P. N. Measurements of L X-ray fluorescence cross sections and yields for elements in the atomic range 4 1 ~ 2 ~ 5 2 at 5.96 keV Nucl. Instrum. Methods Phys. Rex 1992 B72 147. (Dept. Phys. Dept. Biophys. Panjab Univ. Chandigarh- 1 600 14 India).Dias T. H. V. T. Santos F. P. Stauffer A. D. Conde C. A. N. Distortion effects in soft-X-ray energy spectra for xenon gaseous detectors a Monte Carlo simulation study Phys. Rev. A 1992 46 237. (Dept. Fis. Univ. Coimbra 3000 Coimbra Portugal). at the IEEE- 1 992 Nucl. Science Symposium Orlando (USA) Oct. 27-31 1992. 93lC3817.Conde. C. A. N.. Dos Santos. J. M. F.. Bento. 93138 18. 93138 19. 9 313 820. 931382 1. 9313822. 9313823. 9 313 8 24. 9313825. 9313826. A. C. S. S. M. New concepts for the design of large area gas proportional scintillation counters (Pys. Dept. Univ. Coimbra P-3000 Coirnbra Portugal). Mori H. Haruyama S. Shinozaki Y. Okino H. Iida A. Takanashi R. Sakuma I. Husseini W. K. Payne B. D. Hoffman J. I. E. New non-radioactive micro- spheres and more sensitive X-ray fluorescence to mea- sure regional blood flow Am.J. Physiol. 1992 263(6 Pt. 2) H1946. (Sch. Med. Tokai Univ. Isehara 259-1 Japan). Tariq M. A. Preiss I L. Determination of selenium in animal tissue samples using radioisotope induced X-ray fluorescence J. Radioanal. Nucl. Chem. 1992,163,355. (Dept. Chem. Rensselaer Polytech. Inst. Troy NY 12 180 USA). Frank K. D. Burch J. Denning J. Mineral analysis of corn leaves by X-ray fluorescence on ground versus unground leaf samples Commun. Soil Sci. Plant Anal. 1992 23,241 5 . (Dept. Agron. Univ. Nebraska Lincoln Li H. He C.-f. Yuan X.-s. Determination of trace elements in soil by X-ray fluorescence spectrometry using empirical coefficient method Fenxi Shiyanshi 1992 11(4) 53. (Dept. Chem. Chem. Eng.Henan Univ. Kaifeng 475001 China). Bao S.-x. Shen P. X-ray fluorescence spectrometric determination of 1 7 elements in calcareous shells Fenxi Huuxue 1992 20 688. (Lanzhou Inst. Geol. Chin. Acad. Sci. Lanzhou 730000 China). Raoof S. A. Al-Sahhaf M. Study of particulate pollutants in the air of Riyadh by energy dispersive X-ray fluorescence spectrometry Atmos. Environ. Part B 1992 26 421. (Dept. Phys. Coll. Educ. Girls Riyadh Saudi Arabia). Harangozo M. Tolgyessy J. Dillinger P. Determina- tion of copper nickel zinc and lead contents in soil near the D-6 1 Bratislava-Trnava highway by radio- nuclide X-ray fluorescence analysis J. Radioanal. Nucl. Chem. 1993 175 33. (Fac. Chem. Technol. STU Bratislava Czechoslovakia). Hegedues F. Fast neutron dosimetry of the reactor pressure vessel by means of the scraping sampling method.Measurement of the niobium mass by TXRF spectrometry Proc. ASTM-EURA TOM Symp. React. Dosim. 7th 1990 (Pub. 1992) 86 I . (Paul Scherrer Inst. CH-5232 Villigen Switzerland). Kurakado M. Takahashi T. Matsumura A. Ito S. Katano R. Isozumi Y. X-ray detection with a niobium- NE 68583-09 16 USA).394R 9313827. 9313828. 9313829. 9 313830. 931383 1. 9313832. 9 313 8 33. 9313834. 9313 8 3 5. 9 313 8 3 6. 9313837. 931355 1. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 based junction and investigation of series-junction detectors Proc. SPIE-Int. SOC. Opt. Eng. 1992 1743 351. (Adv. Mater. Technol. Res. Lab. Nippon Steel Corp. Kawasaki 21 1 Japan). Kucukonder A. Sahin Y. Buyukkasap E. Kopya A.Chemical effects on W:Ka X-ray intensity ratios in coordination compounds of some 3d elements J. Phys. B At. Mol. Opt. Phys. 1993 26 101. (Fac. Arts Sci. Yuzuncu Yil Univ. Van 65080 Turkey). Dietz K. L. Ramsey B. D. Weisskopf M. C. Perform- ance of a multistep fluorescence-gated proportional counter for hard X-ray astronomy Proc. SPIE-Int. SOC. Opt. Eng. 1992 1743 236. (Marshall Space Flight Cent. NASA Huntsville AL 358 12 USA). Saulnier G. G. Zacher R. A. Van Vechten D. Boyer C. Lovellette M. N. Fritz G. G. Soulen R. J. Kang J. Blamire M. Optimization of niobium tunnel junctions as X-ray detectors Proc. SPIE-Int. SOC. Opt. Eng. 1992 1743 2. (Nav. Res. Lab. E. 0. Hulburt Cent. Space Res. Washington DC 20375 USA). Rippert E. D. Ketterson J. B. Chen J. Song S. Lomatch S.Maglic S. R. Thomas C. Cheida M. A. Ulmer M. P. Role of engineered materials in supercon- ducting tunnel junction X-ray detectors-suppression of quasiparticle recombination losses via a phononic band gap Proc. SPIE-Int. SOC. Opt. Eng. 1992,1743 12. (Dept. Phys. Astron. Northwestern Univ. Evanston IL 60208 USA). De Korte P. A. J. Van den Berg M. L. Bruijin M. P. Frericks M. Le Grand J. B. Gijsbertsen J. G. Houwman E. P. Flokstra J. Superconductive tunnel junctions for X-ray spectroscopy Proc. SPIE-Int. SOC. Opt. Eng. 1992 1743 24. (Lab. Space Res. 3584 CA Utrecht The Netherlands). McCarthy K. J. Wells A. Measurements and simula- tions of X-ray quantum efficiency and energy resolution of large area CCDs between 0.3 and 10 keV Proc. SPIE- Int. SOC. Opt. Eng.1992 1743 21 1. (Dept. Phys. Astron. Univ. Leicester Leicester UK LE 1 7RH). Viitanen V. P. Nenonen S. Partanen P. Sipila H. Mutikaninen R. X-ray windows for spaceborne detec- tors Proc. SPIE-Int. SOC. Opt. Eng. 1992 1743 245. (Outokumpu Electron. Oy SF-0220 1 Espoo Finland). Barber W. C. Bland R. W. Carpenter J. W. Johnson R. T. Laws K. E. Lockhart J. Lee J. S. Watson R. M. Labov S. E. An X-ray detector using supercon- ducting aluminium tunnel junctions Proc. SPIE-Int. SOC. Opt. Eng. 1992 1743 339. (Phys. Astron. Dept. San Francisco State Univ. San Francisco CA 94132 USA). Juda M. Cui W. McCammon D. Morgenthaler J. Sanders W. T. Zhang J. Kelley R. L. Madejski G. Moseley S. H. Thermal detectors for X-ray astronomy current performance and limitations Proc SPIE-Int.SOC. Opt. Eng. 1992 1743 398. (Dept. Phys. Univ. Wisconsin Madison WI 53706 USA). Benz M. G. Jackson M. R. Zabala R. J. Lou K. A. Tiearney T. C. Jr. High performance metal X-ray tube target having a reactive barrier layer U.S. US 5,159,6 19 16 Sep 199 1; 6 pp. (General Electric USA). Kroninger F. Streckfuss N. Frey L. Falter T. Ryzlewicz C. Pfitzner L. Ryssel H. Application of advanced contamination analysis for qualification of wafer handling systems and chucks Appl. SurJ Sci. 1993 63 93. (Fraunhofer-Arbeitsgruppe fur Integr. Schaltungen Artilleriestrasse 12 D-8520 Erlangen Germany). Paukert T. Analysis for trace amounts of rare earth elements in rocks Geol. Pruzkum 1992,34 270. (Cesky Geol. Ustav Prague Czechoslovakia). (CI. 378-143; HOlJ351OS) 27 OCt 1992 Appl.760,262 9 3/38 3 8. 9313839. 9 313840. 931384 1. 9313842. 9313843. 9313844. 9313845. 9313846. 9313847. 9313848. 9313849. 9313850. 931385 1. 93/38 52. Tao G.-y. Pei L.-w. Ji A. Software for reading and re-writing datafile created by PW 1400 PW 1404 PW 1600 and PW 1606 spectrometers Guangpuxue Yu Guangpu Fenxi 1992 12 12 1. (Shanghai Inst. Ceram. Acad. Sin. Shanghai 200050 China). Ryabushko 0. P. Pilipenko A. T. Batkovskaya L. A. Karmanov V. I. Quinoxalin-2,3-dithiol as a reagent for concentration during X-ray fluorescent determination of nickel and cobalt in ores Ukr. Khim. Zh. (Russ. Ed.) 1992 58 746. (Kiev. Gos. Univ. Kiev Ukraine). Wei C.-l. Li D.-l. Hu J.-s. Fan Q.-m. Liu Y.-w. Measurement of the K value in gold jewelry by XRF method Hejishu 1992 15 531.(Inst. High Energy Phys. Acad. Sin. Beijing 100080 China). Li M. Chen Y.-p. Su H.-x. Determination of trace elements in rocks and soils by extraction preconcen- tration-XRFS (X-ray fluorescence) Guangpuxue Yu Guangpu Fenxi 1992 12 1 1 1. (Beijing Agric. Inst. Beijing 102208 China). Brune D. X-ray fluorescence method for detection of corrosion attack in metal surfaces PCT Int. Appl. WO 92 07,246 (Cl. GOlN17100) 30 Apr 1992 NO Appl. 9014,504 18 Oct 1990; 10 pp. Misra G. Mittal V. K. Sahota H. S. Elemental analysis of chipslfilms of nail polishes by EDXRF Indian J. Forensic Sci. 1992 6 79. (Forensic Sci. Lab. Punjab 160 009 India). Jones T. G. J. Hughes T. L. Tomkins P. G. Analysis of drilling fluids Eur. Pat. Appl. EP 507,405 (CI. GOlN21/55) 07 Oct 1992 GB Appl. 9117,041 04 Apr 199 1 ; 53 pp.(Services Petroliers Schlumberger Cam- bridge UK). Zhou S.-h. Xie T.-z. Ge L.-q. Total content X-ray fluorescence method for copper prospecting Nucl. Sci. Tech. 1992 3 191. (Chenglu Coll. Geol. Chenglu 6 10059 China). Kraus H. Jochum J. Kemmather B. Gutsche M. High resolution X-ray spectroscopy with superconduct- ing tunnel junctions Proc. SPIE Int. SOC. Opt. Eng. 1992 1743 36. (Phys. Dept. E15 Tech. Univ. Muen- chen D-8046 Garching Germany) Garg M. L. Garg R. R. Hennrich F. Heimermann D. Elastic and inelastic scattering of photons in the X-ray energy region Nucl. Instrum. Methods Phys. Res. Sect. B 1993 73 109. (Inst. Strahlen Kernphys. Univ. Bonn D-5300 Bonn 1 Germany). Rao D. V. Cesareo R. Gigante G. E. L X-ray fluorescence cross sections and intensity ratios in some high-Z elements excited by 23.62 and 24.68 keV photons Phys.Rev. A 1993,47 1087. (Dipt. Fis. Univ. Rome ‘La Sapienza’ 00185 Rome Italy). Murthy M. V. K. Rao K. S. Murti V. R. Parthasara- dhi K. Reddy T. S. Babu G. R. Reddy B. S. Studies on K X-ray satellite energy shifts Indian J. Pure Appl. Phys. 1993 31 137. (Cent. Stud. Resour. Eng. Indian Inst. Technol. Bombay 400 076 India). Van den Hoogenhof W. W. De Boer D. K. G. Glancing-incidence X-ray analysis Spectrochim. Acta Part B 1993 48 277. (Philips Anal. 7602 EA Almelo The Netherlands). Stephan K. H. Braeuninger H. Reppin C. Maier H. J. Frischke D. Krumrey M. Mueller P. Radiation entrance windows for CCD-detectors Pruc. SPIE-Int. SOC. Opt. Eng. 1992 1743 192. (Max-Planck-Inst. Extraterr.Phys. W-8046 Garching Germany). Labov S. E. Mears C. A. Morris G. W. Cunningham C. E. Le Gros M. A. Silver E. H. Barfknecht A. T. Madden N. W. Landis D. A. Superconducting tunnel junction X-ray detectors with niobium absorbers and aluminium quasiparticle traps Pruc. SPIE-Int. Suc. Opt.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 395R 931385 3. 9313854. 93/38 5 5. 93/38 56. 9313857. 9313 8 58. 9313859. 9313860. 931386 1. 9313862. 9313863. 9313864. 93/38 65. 9313866. 9313867. Eng. 1992 1743 328. (Lab. Exp. Astrophys. Lawrence Livermore Natl. Lab. Livermore CA 94550 USA). Bonura A. Giarrusso S. Lombardo L. Manzo G. Re S. La Rosa G. Celi F. Di Raffaele R. High pressure gas scintillation proportional counter performance characteristics of the scientific model Proc.SPIE-Int. SOC. Opt. Eng. 1992 1743 523. (1st. Fis. Cosm. Appl. Inf. CNR 90139 Palermo Italy). Tsutsui H. Ohtsuchi T. Ohmori K. Baba S. Mea- surement of X-ray spectrum using a small size cadmium telluride multichannel detector IEEE Trans. Nucl. Sci. 1992 39 2282. (Device Process Technol. Lab. Mat- sushita Electr. Ind. Co. Moriguchi 570 Japan). Tirsell K. G. Bowers M. W. Elsholz A. J. Randolph J. E. Novel moveable multi-anode X-ray source for imaging detector calibrations Proc. SPIE-Int. SOC. Opt. Eng. 1993 1736 106. (Lawrence Livermore Natl. Lab. Livermore CA 94550 USA). Vazquez C. De Leyt D. V. X-ray fluorescence chemi- cal analysis by thin-film technique An. Asoc. Quim. Argent. 1992 80 305. (Dept. Quim. Anal. Com. Nac. Energ. At. Buenos Aires Argentina).Delbrouck-Habaru J. M. Weber G. Aloupogiannis P. Robaye G. Roelandts I. Determination of the best experimental conditions for using the a! parameters method to calculate matrix corrections for infinitely thick targets (TTPIXE) Nucl. Instrum. Methods Phys. Res. Sect. B 1993,73,71. (Inst. Phys. Nucl. Exp. Univ. Liege B-4000 Liege Belgium). Hegedues F. Total reflection X-ray fluorescence (TXRF) spectrometer for measurement of ultratrace elements Chimia 1992 46 477. (Paul Scherrer Inst. CH-5232 Villigen Switzerland). Brady M. A. Price B. J. Rapid analysis of cement to ASTM C-114 World Cem. 1992,23(8) 24. (Ind. Anal. Group Oxford Instrum. 19-20 Nuffied Way Abing- don Oxfordshire UK OX 14 1 TX). Nashashibi T. Pentafet and its applications in high resolution and high rate radiation spectrometers Nucl.Instrum. Methods Phys. Res. Sect. A 1992 322 551. (Link Anal. High Wycombe Buckinghamshire UK HP12 3SE). Zhou C.-x. Fabrication and testing of X-ray optical elements Proc. SPIE-Int. SOC. Opt. Eng. 1992 1720 272. (Changchun Inst. Opt. Fine Mech. Chin. Acad. Sci. Changchun 130022 China). Nigam A. N. Srivastava S. K. Additive property of Slater’s screening constants with reference to X-ray K-emission lines Indian J. Phys. A 1992 66 399. (Phys. Dept. Harcourt Butler Technol. Inst. Kanpur 208 002 India). Balucinska-Church M. McCammon D. Photoelectric absorption cross sections with variable abundances Astrophys. J. 1992 400 699. (Sch. Phys. Space Res. Univ. Birmingham Birmingham UK B 15 2TT). Sartori R. Fernandez J.E. High-order multiple scat- tering contributions in X-ray spectrometry X-Ray Spec- trom. 1992 21 299. (Lab. Ing. Nucl. Montecuccolino Univ. Bologna 40 136 Bologna Italy). Gabutti A. Gray K. E. Self-recovering superconduct- ing strip detectors Low Temp. Detect. Neutrinos Dark Matter IV Proc. Int. Workshop 4th 1991 (Pub. 1992) 333. (Argonne Natl. Lab. Argonne IL 60439 USA). Uchida F. Suzuki Y. Fabrication and testing of grazing incidence mirrors for hard X-rays Proc. SPIE- Int. SOC. Opt. Eng. 1992 1720 264. (Hitachi Cent. Res. Lab. Kokubunji 185 Japan). Smith G. C. Yu B. Fischer J. Radeka V. Harder J. A. High rate high resolution two-dimensional gas proportional detectors for X-ray synchrotron radiation experiments Nucl. Instrum. Methods Phys. Rex. Sect. A 9313868.9313869. 9313 870. 9313871. 9313872. 9313873. 9313874 9313875. 9 313 8 76. 9313877. 9313878. 9313879. 9313880. 931388 1. 9313882. 1992 323 78. (Brookhaven Natl. Lab. Upton NY 11973 USA). Steinmeyer P. A. Multiple wavelength X-ray mono- chromators U.S. US 5,164,975 (CI. 378-85; G2 1 K1/06) I7 Nov. 1992 Appl. 7 14,805 I3 Jun 199 1 ; 9 pp. (United States Dept. Energy). Tamura K. X-ray mirror Jpn. Kokai Tokkyo Koho JP 04,164,297 [92,164,297] (CI. G21K1/06) 09 Jun 1992 Appl. 901291,053 29 Oct 1990; 4 pp. (Seiko Instru- ments Japan). Hsu E. Parks H. G. Craigin R. Tomooka S. Ramberg J. S. Lowry R. K. Deposition characteristics of metal contaminants from hydrogen fluoride-based process solutions onto silicon wafer surfaces J. Electro- chem. Soc. 1992 139 3659. (Dept.Electr. Computer Eng. Univ. Arizona Tucson AZ 85721 USA). Roessiger V. Validity of a simple approximation for enhancement calculations X-Ray Spectrom. 1992 21 245. (Zentralinst. Isot. Strahlenforsch. Leipzig 7060 Leipzig Germany). Baechmann K. Steigrwald K. Klenk H. Development of a method for direct analysis of solids as thin films by energy dispersive X-ray fluorescence analysis Mikro- chim. Acta 1992 108 299. (Fachbereich Chem. Tech. Hochsch. Darmstadt D-W 6 100 Darmstadt Germany). Lavrinenko A. I. Faingol’d M. I. Calculation of a two- layered filter for the X-ray fluorescent analysis for sulfur in hydrocarbons Zh. Prikl. Spektrosk. 1992 57 208. (Inst. Tekh. Teplofiz. Kiev Ukraine). Slatkin D. N. Kalef-Ezra J. A Balbi K. E. Wielopol- ski L. Rosen J. F. L-line X-ray fluorescence of tibia1 lead correction and adjustment of radiation risk to ICRP 60 Radiat.Prot. Dosim. 1992 42 319. (Clin. Res. Cent. Brookhaven Natl. Lab. Upton NY 11973 USA). Cesareo R. Gigante G. E. Iwanczyk J. S. Dabrowski A. Use of a mercuric iodide detector for X-ray fluorescence analysis in archaeometry Nucl. Instrum. Methods Phys. Res. Sect. A 1992 322 583. (Dept. Energ. Univ. Rome ‘La Sapienza’ Rome Italy). Cousins C. S. G. Gerward L. Laundy D. Meads R. E. Olsen J. S. Sheldon B. J. Pile-up phenomena in solid-state detection. Effects due to synchrotron sources Nucl. Instrum. Methods Phys. Res. Sect. A 1993 324 598. (Phys. Dept. Univ. Exeter Exeter UK EX4 4QL). Shaw K. D. Effects of interfacial defects on the performance of grazing-incidence synthetic multilayer reflectors for medium- and low-energy X rays J.Opt. SOC. Am. A Opt. Image Sci. 1992,9,223 1. (Radiat. Sci. Inc. Belmont MA 02 178 USA). He H. Wark J. S. Foerster E. Uschmann I. Renner O. Kopecky M. Blyth W. Double-crystal high-resolu- tion X-ray spectroscopy of laser-produced plasmas Rev. Sci. Instrum. 1993,64 26. (Dept. Phys. Univ. Oxford Oxford UK OX1 3PU). Bhuinya C. R. Padhi H. C. Alloying effect on the Kp:Kar intensity ratios of titanium chromium and nickel J. Phys. B At. Mol. Opt. Phys. 1992 25 5283. (Inst. Phys. Bhubaneswar 75 1005 India). Michalik V. Pernicka F. Backscattering of low-energy photons on dead layers of a germanium detector Jud. Energ. 1992 38 98. (Inst. Radiat. Dosimetry Prague Czechoslovakia). Dudchik Yu. L. Komarov F.F. Lobotsky D. G. Soloviev V. S. Tishkov V. S. Study of transmission of multilayer thin-film X-ray guides Nucl. Instrum. Methods Phys. Res. Sect. A 1993 325 343. (Inst. Appl. Phys. Probl. Minsk Belarus). Yamada A. Adachi N. X-ray reflector plates Jpn. Kokai Tokkyo Koho JP 04,133,000 [92,133,000] (C1.396R 9313883. 9 313 8 84. 9313885. 9313886. 9313 88 7. 9 313 8 8 8. 9313889. 931 3 8 90. 931389 1. 9313892. 9 31389 3. 9313894. 9313895. 9313896. 9313897. 9313898. 9313899. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 G21K1/06) 07 May 1992 Appl. 901256,035 25 Sep 1990; 4 pp. (Adachi Shin Sangyo K. K. Japan). Kondo S. Multilayer film X-ray mirror Jpn. Kokai Tokkyo Koho JP 04,250,400 [92,250,400] (Cl. G21K1/06) 07 Sep 1992 Appl. 911921,09 Jan 1991; 4 pp.(Hitachi Tokyo 185 Japan). Tamura K. X-ray mirrors Jpn. Kokai Tokkyo Koho JP 04,169,899 [92,169,899] (CI. G2 1 K1106) 17 Jun 1992 Appl. 901298,202 02 Nov 1990; 3 pp. (Seiko Instru- ments Japan). Revenko A. G. Improvement of energy-dispersive X-ray fluorescence analysis. Review. Zavod. Lab. 1992 58(6) 12. (Inst. Zemnoi Kory Irkutsk Russia). Tan Y.-j. Li J.-m. Automated system in rare earth element analysis with the X-ray fluorescence spectro- meter Yuanzineng Kexue Jishu 199 1,25(4) 18. (China Inst. At. Energy Beijing China). Bormann R. Schwenke H. Spectroscopic method and device for determining elements at predetermined levels in objects Ger. Offen. DE 4,028,044 (Cl. GOlN23/203) 12 Mar 1992 Appl. 05 Sep 1990; 5 pp. (GKSS- Forschungszentrum Geesthacht GmbH Germany).Hoover B. B. X-ray monochromator U.S. US 5,173,930 (Cl. 378-85; G21K1/06) 22 Dec 1992 Appl. 803,268 22 Nov 1991; 5 pp. (United States National Aeronautics and Space Administration USA). Taylor W. D. Low surface distortion X-ray monochro- mator Eur. Pat. Appl. EP 520,671 (Cl. G02B7/18) 30 Dec 1992 US Appl. 723,081 28 Jun 1991; 13 pp. (Hughes Aircraft Co. USA). Schnug E. Boenke A. Wagstaffe P. J. Lindsey A. S. Characterization of three certified rapeseed reference materials and their utilization in the indirect determina- tion of total glucosinolates in rape seed by X-ray fluorescence (XRF) Fett Wiss. Technol. 1992 94 297. (Inst. Pflanzenernaehr. Bodenkd. Bundesforschung- sanst. Landwirtsch. W-3300 Braunschweig Germany). Moon K. H. Hong K. J. Lee D. H.Cho S. Y. Rapid analysis of ferroalloys by XRF (X-ray fluorescence) spectrometry Yongu Kipo-Sanop Kwahak Kisul Yon- guso 1992 6 70. (Res. Inst. Ind. Sci. Technol. Pohang S. Korea). Malgrange C. X-ray optics for synchrotron radiation Acta Phys. Pol. A 1992 82 13. (Lab. Mineral. Cristal- logr. Univ. Paris 6 75252 Paris France). Usui T. Handy and convenient X-ray chemical analysis method for superconducting thin films ISTEC J. 1992 5(2) 13. (Div. V. SRL Japan). Schwenke H. Knoth J. Weisbrod U. Analysis of particles on surfaces by total reflection X-ray fluores- cence spectrometry Part. Surt 1991 3 131. (Inst. Phys. GKSS-Forschungszent. Geesthacht Germany). Moras K. Partzscht H. New results on the use of multilayer monochromators for X-ray fluorescence ana- lysis for light elements with VRA-35 Tagungs- vortr.Fachtag. ‘Amorphe Nanodispersive Schichtsyst’ 199 1 2 269. (Freiberg Germany). Todd A. C. McNeill F. E. Fowler B. A. In vivo X-ray fluorescence of lead in bone Environ. Res. 1992 59 326. (Univ. Maryland Baltimore MD 21201 USA). Skerfving S. Nilsson U. Assessment of accumulated body burden of metals Toxicol. Lett. 1992 64-65 17. (Dept. Occup. Environ. Med. Univ. Hosp. S-221 85 Sweden). Fabbri B. Raw material analysis according to the latest technology in the ceramics laboratory Keram. Z. 1992 44 744. (Res. Inst. Ceram. Techno. 1-48018 Faenza Italy). Bettinelli M. Baroni U. Pastorelli N. Bizzarri G. 9313900. 9313901. 9313902. 9313903. 9313904. 9313905. 9 313 906. 9313907. 9 313 908. 9313909. 93139 10. 931391 1. 93/39 12. 93/39 13.analysis comparison of different analytical techniques Elem. Anal. Coal Its By-Prod. Int. Con5 Proc. Znd 199 1 (Pub. 1992) 372. (Cent. Lab. ENEL-DCO 29 100 Piacenza Italy). Gerasimov S. A. Recursive filtering of gamma ray spectra Nucl. Instrum. Methods Phys. Res. Sect. B 1992 72 467. (Inst. Phys. Rostov State Univ. Rostov- on-Don Russia 344 104). Luk T. S. McPherson A. Boyer K. Rhodes C. K. Mechanisms of short-wavelength generation Adv. At. Mol. Opt. Phys. 1992 (Suppl. 1 At. Intense Laser Fields) 207. (Lab. At. Mol. Radiat. Phys. Univ. Illinois Chicago IL USA). Orlic I. Tang S. M. Parametrization of photon mass attenuation coefficients in the energy range 0.1- 1000 keV for elements with Z= 1-40 Singapore J. Phys. 1992 9 57. (Dept. Phys. Natl. Univ. Singapore Singapore 05 1 1 Singapore).Als-Nielsen J. Kjaer K. Crystal spectroscopy of X-ray synchrotron source brightness Nucf. Instrum. Methods Phys. Res. Sect. A 1992 323 686. (Risoe Natl. Lab. Roskilde DK-4000 Denmark). Borovoi N. A. Vasil’ev Yu. O. Erniyazov A. S. Surzhko V. F. Shiyanovskii V. I. Group of scandium K+4-satellites under different excitation conditions Ukr. Fiz. Zh. (Russ. Ed.) 1992 37 1563. (Kiev Univ. Kiev 252601 Ukraine). Fraser G. W. Brunton A. N. Lees J. E. Pearson J. F. Feller W. B. X-ray focusing using square-pore micro- channel plates. First observation of cruxiform image structure Nucl. Instrum. Methods Phys. Res. Sect. A 1993 324 404. (Dept. Phys. Astron. Univ. Leicester Leicester UK LE1 7RH). Sasaki S. Miyata K. Takada T. New undulator for generating variably polarized radiation Jpn.J. Appl. Phys. Part 2 1992 31(12B) L1794. (Off. Synchrotron Radiat. Facil. Proj. Japan At. Energy Res. Inst. Tokai 3 19- 1 1 Japan). Nikiforov I. Ya. X-ray monochromator U.S.S.R. SU 1,718,067 (Cl. GOlN23120) 07 Mar 1992 Appl. 4,748,839 08 Aug 1989. Izobreteniya 1992 (9) 160. (Rostov-on-Don Institute of Agricultural Machine Building Russia). Zhang J. Shah K. S. Olschner F. Lund J. C. Moy L. P. Daley K. Cirignano L. Squillante M. R. Improvement in growing large oriented lead iodide single crystals for detector applications Nucl. Instrum. Methods Phys. Res. Sect. A 1992 322 499. (Radiat. Monit. Devices Watertown MA 02 172 USA). Wang Y.-m. Bulk analysis microanalysis and distribu- tion analysis for elements in rocks and minerals Fenxi Huaxue 1992 20 850.(Inst. Rock Miner. Anal. Beijing 100037 China). Rauhvarger A Elementary principles of some analyti- cal methods used in ecological studies Instrum. Metody Anal. Ekol. 1991 1 6. (Latv. Med. Akad. Latvia). Jenkins R. X-ray fluorescence analysis Mater. Sci. Technol. 1992 2A 6 19. (JCPDC-Int. Cent. Diffr. Data Swarthmore PA USA). Markowicz A. Haselberger N. Mulenga P. Accuracy of calibration procedure for energy-dispersive X-ray fluorescence spectrometry X-Ray Spectrom. 1992 21 271. (Agency’s Lab. Int. At. Energy Agency A-2444 Seibersdorf Austria). Finkelshtein A. L. Gunicheva T. N. Kalughin A. G. Afonin V. P. Calculation of X-ray fluorescence and scattered primary radiation intensities in X-ray fluores- cence analysis of powder slurry-like materials X-Ray Spectrom. 1992 21 287.(Inst. Geochem. Irkutsk Taina P. ICP-AES GFAAS XRF and NAA coal fly ash Russia).JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 397R 93/39 14. 93139 15. 93/39 16. 931391 7. 93/39 18. 93139 19. 9313920. 931392 1. 9313922. 9 313923. 9313924. 9313925. 9313926. van den Bogaert B. Morsink J. B. W. Smit H. C. Expert system for the determination of the analytical strategy in a laboratory for elemental analysis. Part 1. Project definition Anal. Chim. Acta 1992 270 107. (Lab. Anal. Chem. Univ. Amsterdam Amsterdam The Netherlands). van den Bogaert B. Morsink J. B. W. Smit H. C. Expert system for the determination of the analytical strategy in a laboratory for elemental analysis. Part 2. Development of an X-ray fluorescence subsystem Anal.Chim. Acta 1992 270 115. (Lab. Anal. Chem. Univ. Amsterdam Amsterdam The Netherlands). Ghazsli A. B. Hoyes G. Use of commercially available PC-interface cards for elemental mapping in small samples using XRF J. Sains Nukl. Malays. 1991 9 12 1. (Unit Tenaga Nukl. Kompleks Puspati Kajang 43000 Malaysia). Muramatsu Y. Oshima M. Shoji T. Kato H. Undulator-radiation-excited X-ray fluorescence analysis system for light elements Rev. Sci. Instrum. 1992 63 5597. (Interdiscip. Res. Lab. NTT Musashino 180 Japan). Zamyshlyaeva L. M. Berngarat V. Kh. Amerkhanov M. A. Development of a method for determination of silicon dioxide phosphorus and total iron in a Lisa- kovsk magnetic-roasted concentrate with sample prepa- ration by fusion Zavod. Lab.1992 587 50. (Russia). Zhu B. Shen W.-s. Determination of silicon and aluminium in rare earth concentrates by X-ray spectro- metric method Fenxi Shiyanshi 1990 9(1) 29 24. (Jiangxi Prov. Anal. Test. Inst. Nanchang 330029 China). Eisman M. Gallego M. Valcarcel M. Automatic continuous-flow method for the determination of co- caine Anal. Chem. 1992 64 1509. (Fac. Sci. Univ. Cordoba Cordoba 14004 Spain). Van Veen E. H. De Loos-Vollebregt M. T. C. Wassink A. P. Kalter H. Determination of trace elements in uranium by inductively coupled plasma atomic emission spectrometry using Kalman filtering Anal. Chem. 1992 64( 1 5) 1643. (Lab. Mater. Sci. Delft Univ. Technol. 2628 AL Delft The Netherlands). Reddi G. S. Ganesh S. Rao C. R. M. Ramanan V. Determination of gold in geological materials by atomic absorption spectrometry after bromine and hydro- chloric acid extraction at room temperature Anal. Chim.Acta 1992 260 131. (Chem. Div. Geol. Surv. India Madras 600 032 India). Tyson J. F. Bysouth S. R. Grzeszczyk E. A Debrah E. Flow injection atomic spectrometry a new analytical technique Anal. Chim. Acta 1992 261 75. (Dept. Chem. Univ. Massachusetts Amherst MA 01003 USA). Welz B. Tsalev D. Sperling M. On-line microwave sample pre-treatment for the determination of mercury in water and urine by flow injection cold vapour atomic absorption spectrometry Anal. Chim. Acta 1992 261 91. (Dept. Appl,. Res. Bodenseewerk Perkin-Elmer GmbH W-7770 Uberlingen Germany). Burguera M. Burguera J. L. Brunetto M. R. De la Guardia M. Salvador A. Flow injection atomic spec- trometric determination of inorganic arsenic(rrr) and arsenic(v) species by use of an aluminium-column arsine generator and cold-trapped arsine collection Anal.Chim. Acta 1992 261 105. (Fac. Sci. Univ. Los Andes Merida 5 1 0 1 -A Venezuela). Sperling M. Koscielniak P. Welz B. Improvement of detection limits for flow injection flame atomic absorp- tion spectrometry by dedicated signal processing Anal. Chim. Acta 1992 261 1 15. (Dept. Appl. Rzs. Boden- seewerk Perkin-Elmer GmbH W-7770 Uberlingen Germany). 9313927. 9313928. 9313929. 9313930. 931393 1. 93/39 32. 931 39 33. 9313934. 9313935. 9313936. 931393 7. 9313938. 9313939. 9313940. 931394 1. Web B. Yin X.-f. Sperling M. Time-based and volume-based sampling for flow injection on-line sor- bent extraction graphite furnace atomic absorption spectrometry Anal. Chim.Acta 1992 261,477. (Dept. Appl. ..Res. Bodenseewerk Perkin-Elmer GmbH W- 7770 Uberlingen Germany). Trojanowicz M. Szostek B. Real-time digital filters for signal processing in flow injection analysis. Part 2. Practical applications Anal. Chim. Acta 1992 261 521. (Dept. Chem. Univ. Warsaw 02-093 Warsaw Poland). Fang Zh.4 Sun L.-j. Xu S.-k. First decade of flow injection analysis in China Anal. Chim. Acta 1992 261 557. (Inst. Appl. Ecol. Acad. Sin. Shenyang 1 1001 5 China). Venkateswarlu P. Determination of fluoride in bone by aluminium monofluoride molecular absorption spectro- metry Anal. Chim. Acta 1992 262 33. (Ind. Chem. Prod. Div. 3M St. Paul MN 55144 USA). Carriilo F. Perez C. Camara C.Sensitive flow injection spectrofluorimetric method to determine a h - minium(r1r) in water Anal. Chim. Acta 1992 262 9 1. (Fac. Quin. Univ. Complutense Madrid 28040 Spain). Kobayashi S. Wakui Y. Kanesato M. Matsunaga H. Suzuki T. M. Chromatographic separation and induc- tively coupled plasma atomic emission spectrometric determination of the rare earth metals contained in terbium Anal. Chim. Acta 1992 262 161. (Miyagi Prefect. Inst. Technol. Sendai 980 Japan). Archer F. A. Street K. W. Jr. Spectrophotometric determination of silicon in bismuth borosilicate glass by flow injection Anal. Chim. Acta 1992 262 243. (Lewis Res. Cent. NASA Cleveland OH 44135 USA). Iwamoto E. Hashimoto H. Kumamaru T. Graphite furnace atomic absorption spectrometry with graphite cloth ribbon and its application to determination of arsenic in mussel Anal.Sci. 1992 8 389. (Fac. Sci. Hiroshima Univ. Higashi-Hiroshima 724 Japan). Hulanicki A. Bulska E. Wrobel K. Calibration and reference samples in trace metals determination in serum by graphite furnace atomic absorption spectro- metry Anal. Sci. 1992 8 405. (Dept. Chem. Univ. Warsaw 02-093 Warsaw Poland). Hirokawa K. Yasuda K. Takada K. Graphite furnace atomic absorption spectrometry and phase diagrams of alloys Anal. Sci. 1992 8 41 1. (Inst. Mater. Res. Tohoku Univ. Sendai 980 Japan). Takiyama K. Ishii Y. Comparison of digestion methods for atomic absorption analysis of food ma- terials Anal. Sci. 1992 8 419. (Dept. Home Sci. Mukogawa Women’s Univ. Nishinomiya 663 Japan). Ohta K. Itoh S. Kaneco S.Mizuno T. Direct determination of manganese in biological materials using electrothermal atomization atomic absorption spectrometry with a molybdenum tube atomizer Anal. Sci. 1992 8 423. (Fac. Eng. Mie Univ. Tsu 514 Japan). Hirano Y. Nomura Y. Yasuda K. Hirokawa K. Direct analysis of whole blood for trace elements by graphite furnace atomic absorption spectrometry Anal. Sci. 1992,8 427. (Instrum. Div. Hitachi Katsuta 312 Japan). Atsuya I. Aryu K. Zhang Q.-b. Direct determination of cobalt and nickel in powdered biological samples by graphite furnace atomic absorption spectrometry Anal. Sci. 1992 8 433. (Kitami Inst. Technol. Kitami 090 Japan). Nishikida K. Hannah R. W. Kramers-Kronig calcula- tion of the grazing angle reflection spectrum of barrier oxide layer on aluminium Appl.Spectrosc. 1992 46 999. (Perkin-Elmer Wilton CT 06897 USA).398R 9313942. 9 31 394 3. 9313944. 9 31 3 945. 931 3946. 9 313947. 9313948. 9313949. 931 3950. 931395 1. 931 3 9 5 2. 9313953. 9313954. 9 3/39 5 5 . JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 Burguera J. L. Burguera M. Matousek de Abel de la Cruz A. Anez N. Alarcon 0. M. Microwave-aided micro-dissolution of biological samples prior to flow injection atomic absorption spectrometry At. Spec- trosc. 1992 13,67. (Fac. Sci. Univ. Los Andes Merida 5 10 I -A Venezuela). Bettinelli M. Spezia S. Bizzarri G. Determination of bismuth in steels and nickel alloys comparison between FI-HGAAS and GFAAS At. Spectrosc. 1992 13 75. (Cent. Lab. ENEL-DCO 29 100 Piacenza Italy).Yuan D.-x. Wang X.-r. Yang P.-y. Huang BA. Preconcentration of zinc in sea-water on carboxymethy- lated plyethylenimine polymethylenepolyphenylene iso- cyanate resin by flow injection analysis and on-line detection using inductively coupled plasma atomic fluorescence spectrometry Fenxi Huaxue 1992 20 162. (Dept. Chem. Xiamen Univ. Xiamen 361005 China). Xuan W.-k. Effect of matrix modifier of palladium and magnesium on the atomization of lead bismuth and germanium in graphite furnace atomic absorption spec- trometry Fenxi Huaxue 1992 20 209. (Shanghai Iron Steel Res. Inst. Shanghai 200940 China). Wu Q.-f. Zhou S.-z. Zhou L.-h. Fu Hui Preparation of graphite tube coated with lanthanum-zirconium and its application in the determination of trace manganese in groundwater Fenxi Huaxue 1992 20 407. (Dept.Appl. Chem. South China Univ. Technol. Guangzhou 5 1064 1 China). Bao C.-l. Cheng XA Liu C.-h. Wei Y.-d. Determi- nation of trace germanium in plants by graphite furnace atomic absorption spectrometry with methyl isobutyl ketone and N,N-dimethylformamide extraction Fenxi Huaxue 1992 20 429. (Dept. Geochem. Rock Surv. Changchun Univ. Earth Sci. Changchun 130026 China). Wang Q. Determination of trace copper iron zinc magnesium and lead in blood by atomic absorption spectrometry Fenxi Huaxue 1992,20,492. (Wurumuqi City Publ. Health. Antiepidemic Stn. Wurumuqi 830002 China). Liu W.-c. Jin J.-g. Wang S.-y. Spectroscopic proper- ties of obliquely crossed and differential thermal lens spectrometry Fenxi Huaxue 1992 20 532. (Changchun Inst.Appl. Chem. Chin. Acad. Sci. Changchun 130022 China). Yu A.-m. Fan F.-l. Jin Q.-h. Determination of trace zinc by microwave plasma torch atomic emission spectrometry Fenxi Huaxue 1992 20 535. (Dept. Chem. Jilin Univ. Changchun I30023 China). Huang Z.-r. Chen X.-k. Liu Y.-m. Correction of spectral interference in the analysis of high-purity dysprosia by inductively coupled plasma spectrography Fenxi Huaxue 1992 20 600. (Dept. Chem. Nankai Univ. Tianjin 30007 1 China). Su Y.-d. Bian Y.-q. Gu S.-c. Ni Y.-m. Determina- tion of cadmium in soy sauce by flame atomic absorp- tion spectrometry after coprecipitation separation Fenxi Huaxue 1992 20 698. (Dept. Chem. Tonfji Univ. Shanghai 200092 China). Fraile R. De Benzo Z. A. Velosa M. Determination of cadmium in urine by platform ETAAS independent of matrix composition.Calibration against aqueous standards Fresenius’ J. Anal. Chem. 1992 243 319. (Cent. Quim. Inst. Venez. Invest. Cient. Caracas 1020-A Venezuela). Demirata B. Preconcentration of chromium(v1) on melamine formaldehyde resin Fresenius’ J. Anal. Chem. 1992 343 357. (Fac. Sci. Lett. Tech. Univ. Istanbul Istanbul Turkey). Penninckx W. Massart D. L. Smeyers-Verbeke J. Effectiveness of palladium as a chemical modifier for 9313956. 9313957. 9313958. 9313959. 9313960. 931396 1. 9313962. 9313963. 9313964. 9 31 396 5. 931 3966. 9313967. 9313968. 9313969. the determination of lead in biological materials and foodstuffs by graphite furnace atomic absorption spec- trometry Fresenius’ J. Anal. Chem. 1992 343 526. (Farm. Inst.Vrije Univ. Brussel B-1090 Brussels Belgium). Nakashima S. Simultaneous separation of tin and bismuth from water and sea-water by flotation with thionalide Fresenius’ J. Anal. Chem. 1992 343 614. (Res. Inst. Bioresour. Okayama Univ. Kurashiki 7 10 Japan). Doidge P. S. Autonizing lines of aluminium their role in spectral interferences and atom number measure- ment of aluminium in a graphite furnace Spectrochim. Acta Part B 1992 47 569. (Varian Opt. Spectrosc. Instrum. Springvale 3 I70 Australia). Franzke J. Veza D. Niemax K. Improved thermionic diode detector for analytical laser spectroscopy Spectro- chim. Acta Part B 1992 47 593. (Inst. Spektrochem. Angew. Spektrosk. W-4600 Dortmund I Germany). Ciocan A. Uebbing J. Niemax K. Analytical applica- tion of the microwave-induced plasma used with laser ablation of solid samples Spectrochim.Acta Part B 1992 47 6 I I. (Inst. Spektrochem. Angew. Spektrosk. W-4600 Dortmund 1 Germany). D’Ulivo A. Lampugnani L. Zamboni R. Interference studies in the hydride generation atomic fluorescence spectrometric determination of selenium using signal shape analysis by a convolution technique Spectrochim. Acta Part B 1992 47 619. (1st. Chim. Anal. Strumen- tale CNR 56126 Pisa Italy). Welz B. Guo T.-z. Formation and interpretation of double peaks in flow injection hydride generation atomic absorption spectrometry Spectrochim. Acta Part B 1992 47 645. (Dept. Appl. Res. Bodenseewerk Perkin-Elmer GmbH D-7770 Uberlingen Germany). Browner R. F. Canals A. Hernandis V. Effect of analyte and solvent transport on signal intensities in inductively coupled plasma atomic emission spectrome- try Spectrochim.Acta Part B 1992 47 659. (Sch. Chem. Biochem. Georgia Inst. Technol. Atlanta GA Chattaraj S. Das A. K. Indirect determination of thiocyanate in biological fluids using atomic absorption spectrometry Spectrochim. Acta Part B 1992 47 675. (Dept. Chem. Univ. Burdwan Burdwan 7 13 104 In- dia). Li Z. McIntosh S. Carnrick G. R. Slavin W. Hydride generation flow injection using graphite furnace detec- tion emphasis on determination of tin Spectrochim. Acta Part B 1992,47,701 (Perkin-Elmer Norwalk CT Wang J.-p. Deng B. Investigation of the atomization mechanism of iron on the graphite probe surface in a graphite furnace Spectrochim. Acta Part B 1992 47 71 1. (Inst.Photogr. Chem. Beijing 100101 China). Hocquellet P. Electrothermal atomic absorption spec- trometry by re-atomization from a second trapping surface Spectrochim. Acta Part B 1992,47 7 19. (Lab. Munic. Inst. Munic. Rech. Aliment. Hum. Anim. 33300 Bordeaux France). Luecke W. Ionization behaviour of the alkaline earth metals in the air-acetylene and nitrous oxide-acetylene flames Spectrochim. Acta Part B 1992 47 741. (Inst. Petrogr. Geochem. Univ. Karlsruhe Germany). L’vov B. V. Polzik L. K. Kocharova N. V. Theoretical analysis of calibration curves for graphite furnace atomic absorption spectrometry Spectrochim. Acta Part B 1992 47 889. (Dept. Anal. Chem. St. Peters- burg Tech. Univ. St. Petersburg 19525 1 Russia). McIntosh S. Li Z. Carnrick G. R. Slavin W. Determination of tin in steel samples by flow injection 30332-0400 USA).06859-0237 USA).JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 399R 9313970. 931397 I. 9313972. 9313973. 9313974. 9313975. 9 313 9 7 6. 9313977. 9313978. 9313979. 9313980. 931398 1. 9 313982. 931398 3. hydride generation atomic absorption spectroscopy Spectrochim. Acta Part B 1992,47,897. (Perkin-Elmer Norwalk CT 06859-0237 USA). Yebra-Biurmn M. C. Garcia-Dopazo M. C. Bermejo- Barrera A. Bermejo-Barrera M. P. Preconcentration of trace amounts of manganese from natural waters by means of a macroreticular poly(dithiocarbamate) resin Talanta 1992 39 67 1. (Chem. Fac. Univ. Santiago de Compostela Santiago de Compostela 1 5706 Spain). Chang X.-j. Luo X.-y. Zhan G.-y. Su Z.-x. Synthesis and characterization of a macroporous poly(viny1- aminoacetone) chelating resin for the preconcentration and separation of traces of gold palladium rhodium and ruthenium Talunta 1992 39 937.(Dept. Chem. Lanzhou Univ. Lanzhou 780000 China). Karyakin A. V. Simonova L. V. Mechanism of matrix effect of major components in atomic emission determi- nation of trace elements Zh. Anal. Khim. 1992 47 312. (V. I. Vernadskii Inst. Geochem. Amal. Chem. Moscow Russia). Kuhnert B. R. Kuhnert P. M. Groh-Wargo S. L. Webster S. Erhard P. Lazebnik N. Smoking alters the relationship between maternal zinc intake and biochemical indices of foetal zinc status Am. J. Clin. Nutr. 1992 55 98 1. (Cleveland MetroHealth Med. Cent. Case West. Reserve Univ. Cleveland OH USA). Morris B.W. Blumsohn A. Mac Neil S. Gray T. A. Trace element chromium-a role in glucose homeosta- sis Am. J. Clin. Nutr. 1992 55 989. (Dept. Clin. Chem. North. Gen. Hosp. Sheffield UK S5 7AU). Kosman J. Petroleum analysis by using GC-AES Am. Lab. (Shelton Conn.) 1992 24(8) 28T 28V 28X-Z. (Warrensville Res. Environ. Sci. Cent. Br. Pet. Cleve- land OH USA). Wang X.-n. Smeyers-Verbeke J. Massart D. L. Linearization of atomic absorption calibration curves Analusis 1992 20 209. (Farm. Inst. Vrije Univ. Brussel B- 1090 Brussels Belgium). Mostafa M. A Characterization and elimination of the interferences of the complexing agents in flame atomic absorption spectrometric determination of gold Analu- sis 1992 20 283. (Fac. Sci. Mansoura Univ. Man- soura Egypt). Potin-Gautier M. Astruc M.Vermeulin P. Clement A. Comparison of methods for determining total selenium in a plant Analusis 1992 20 M73. (Lab. Chim. Anal. Univ. Pau et des Pays Adour 64000 Pau France). Muralitharan M. S. Chandler S. F. Van Steveninck R. F. M. Effects of sodium sulfate potassium sulfate and potassium chloride on growth and ion uptake of callus cultures of Vaccinium corymbosum L. cv. Blue Crop Ann. Bot. (London) 1992 69 459. (Sch. Agric. La Trobe Univ. Bundoora 3083 Australia). Rabaste F. Jeminet G. Dauphin G. Delort A. M. Conditions modulating the ionic selectivity of transport by monensin examined on Enterococcus hirae (Strepto- coccus faecalis) by sodium-23 NMR and potassium atomic absorption Biochim. Biophys. Acta 1992 1108 177. (Lab. Chim. Org. Biol. Univ. Blaise Pascal 63 177 Aubiere France). Beker D.Romic Z. Krsnjavi H. Zima Z. Contribu- tion to the world selenium map Biol. Trace Elem. Res. 1992 33 43. (Dept. Food Qual. Control ‘PL1VA’- Pharm. Clin. Food Cosm. Ind. Zagreb 4 1000 Croatia). Sakamoto T. Water quality control technology. Analyt- ical methods for boiler feed water and boiler water Boira Kenkyu 1992 251 31. (Organ0 Maint. Serv. K. K. Japan). Rizkalla A. S. Jones D. W. Hall G. C. Sutow E. J. Limits to the incorporation of potassium oxide in 9313984. 9 31398 5. 9313986. 9313987. 9313988. 9313989. 9313990. 931399 1. 9313992. 9313993. 9313994. 9313995. 9313976. feldspathic glasses Br. Ceram. Trans. J. 1992 91 41. (Dept. Appl. Oral Sci. Dalhousie Univ. Halifax Nova Scotia Canada B3H 355). Lafreniere G. F. Peredery O.Persinger M. A. Progressive accumulation of large aggregates of calcium- containing polysaccharides and basophilic debris within specific thalamic nuclei after lithiumlpilocarpine- induced seizures Brain Res. Bull. 1992 28 825. (Behav. Neurosci. Lab. Laurentian Univ. Sudbury Ontario Canada P3E 2C6). Yebra-Biurrun M. C. Bermejo-Barrera A. Bermejo- Barrera P. Preconcentration and determination of traces of strontium in natural waters by ion exchange and flame atomic absorption spectrometry Bull. SOC. Chim. Belg. 1992 101 473. (Chem. Fac. Univ Santi- ago de Compostela Santiago de Compostela 15706 Spain). Bloom N. S. On the chemical form of mercury in edible fish and marine invertebrate tissue Can. J. Fish. Aquat. Scz. 1992 49 101 0. (Brooks Rand Seattle WA 98 107 USA).Nguyen T. Byrd E. Lin C.-j. Bentz D. Novel spectroscopic technique for in situ studies of water at the interface between a metal and an opaque polymeric film Cerum. Trans. 1991 19 1051. (Natl. Inst. Stand. Technol. Gaithersburg MD 20899 USA). Chakraborti D. Gas chromatography-atomic absorp- tion spectrometry (GC-AAS) for species specific deter- mination of organolead compounds in the environment Chem. Environ. Res. 1992 1 3. (Sch. Environ. Stud. Jadavpur Univ. Calcutta 700032 India). Stokley M. E. Newland L. Pozzolana-induced reduc- tions in the environmental availability of cadmium from fly and bottom ash Chemosphere 1992 24 59 1. (Environ. Sci. Program Texas Christ. Univ. Ft. Worth TX 76129 USA). Carlhoff C. Kirchhoff S. Direct analysis in steelmak- ing converters using laser-induced emission spectrome- try Comm.Eur. Communities [Rep.] EUR 1992 EUR 14113 Prog. Anal. Chem. Iron Steel Ind 150. (Krupp Forschungsinst. D-4300 Essen 1 Germany). Eisenhut F. Klein S. Thomas W. Josis T. V. Establishment of a balance of heavy metals during the coal coking process Comm. Eur. Communities [Rep.] EUR 1992 EUR 14113 Prog. Anal Chem. Iron Steel Ind. 165. (DMT Essen Germany). Larsson B. Berglund B. Determination of low boiling elements in steel and nickel-base alloys with a high temperature hollow cathode lamp Comm. Eur. Com- munities [Rep.] EUR 1992 EUR 14113 Prog. Anal. Chem. Iron Steel Ind. 210. (Anal. Chem. Lab. AB SANDVIK STEEL Sandviken Sweden). Tomellini R. Improvement of the direct analysis of trace elements in surface layers and bulk materials by optical emission spectrometry with glow discharge and hollow cathode source Comm.Eur. Communities [Rep.] EUR 1992 EUR 14113 Prog. Anal. Chem. Iron Steel Ind. 218. (Cent. Sviluppo Mater. 1-00129 Rome Italy). Lundholm M. Baltzer P. Determination of nitrogen in steel by VUV emission spectrometry Comm. Eur. Communities [Rep.] EUR 1992 EUR 14113 Prog. Anal. Chem. Iron Steel Ind. 228. (Swed. Inst. Met. Res. S-114 28 Stockholm Sweden). Kobayashi T. Ide K. Hasegawa S. Okochi H. Determination of trace elements in high concentration of matrix solutions of iron zirconium and molybdenum by graphite furnace atomic absorption spectrometry Comm. Eur. Communities [Rep./ Eur 1992 EUR 14113 Prog. Anal. Chem. Iron Steel Ind. 234. (Natl. Res. Inst. Met.Tokyo 153 Japan). Baena J. B. Guio M. J. Hidalgo E. Determination of boron in steels at trace level by means of ICP spectrome-400R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 9 3/399 7. 93/3998. 93/3999. 9314000. 93/400 1. 93/4002. 93/4003. 93/4004. 931400 5. 9314006. try in organic medium Comm. Eur. Communities [Rep.j EUR 1992 EUR 14113 Prog. Anal. Chem. Iron Steel Ind. 24 1. (Acerinox S.A. Algeciras 1 1280 Spain). Ambrose A. D. Jowitt R. Collaborative study of ICP analysis Comm. EUR. Communities [Rep.] EUR 1992 EUR 14113 Prog. Anal. Chem. Iron Steel Ind. 377. (Corby Lab. Br. Steel Tech. Corby Northamptonshire UK NN 17 1UA). Wycislik A. Use of secondary spectral lines in the analysis of alloy steels and electrochemically isolated structural constituents by AAS method Comm.Eur. Communities [Rep.] EUR 1992 EUR 14113 Prog. Anal. Chem. Iron Steel Znd. 542. (Inst. Mater. Sci. Eng. Silesian Tech. Univ. 40-0 17 Katowice Poland). Turner M. D. Brooks P. D. Evaluation of the use of sulfuric acid-hydrogen peroxide digestions for the ele- mental analysis of plant tissue by ICP spectrometry Commun. Soil Sci. Plant Anal. 1992 23 559. (Energy Resour. Group Univ. California Berkeley CA 94720 USA). Somasiri L. L. W. Edwards A. C. Ion-exchange resin method for nutrient extraction of agricultural advisory soil samples Commun. Soil Sci. Plant Anal. 1992 23 645. (Plants Div. Macaulay Land Use Res. Inst. Aberdeen UK AB9 245). Bilhorn R. B. Pomeroy R. S. Denton M. B. Computer- ized multichannel atomic emission spectroscopy Com- put.Enhanced Anal. Spectrosc. 1992 3 281. (Anal. Technol. Div. Eastman Kodak Co. Rochester NY Sharif A. K. M. Mannaf A. Mustafa A. I. Trace elements determination in powder milk by atomic absorption spectrophotometry Dhaka Univ. Stud. Part B 1992 40 49. (Inst. Nucl. Sci. Technol. At. Energy Res. Establ. Dhaka Bangladesh). Stephan M. Hagemann U. Huettig W. Stephan I. Bergsch M. Wiesert J. Wetzel L. Determination of the chemical composition of nuclear reactor contain- ment materials with atomic emission spectrometry Energietechnik (Leipzig) 1992 42 48. (Zentralinst. Kernforsch. Rossendorf Germany). Leharne S. Charlesworth D. Chowdhry B. Survey of metal levels in street dusts in an inner London neigh- bourhood Environ. Int. 1992 18 263. (Sch. Environ. Sci.Thames Polytech. London UK SE8 3BU). Liphard K. G. Fact and fiction trace analysis in soils Erdoel Erdgas Kohle 1992 108 1 7 1. (DMT-Ges. Forsch. Pruef. m.b.H. Essen Germany). Wang J.-p. Deng B. Determination of cobalt in soil and coal fly ash by graphite probe atomization Fenxi Ceshi Tongbao 1992 11 40. (Inst. Photogr. Chem. Acad. Sin. Beiiing 1000 12 China). 14652-3708 USA). 93/4007. Du Y.-p. Tang Y.-q. Shao J.-c. Liu C.-j. Zhu M.-h. Atomic emission spectrometric determination of metals in petroleum distillation residues by ICP using air-ar- gon as plasma gas Fenxi Shiyanshi 1992,11,68. (Anal. Test. Cent. Huadong Inst. Chem. Eng. Shanghai 200237 China). 93/4008. Zhang Y.-z. Determination of the spectral bandwidth of a monochromator by double monochromatic line intensity method Guangpuxue Yu Guangpu Fenxi 1992 12 22.(Shanghai Inst. Tes. Technol. Shanghai 200233 China). 93/4009. Xu F.-p. Chen X.-k. Non-spectral interfering mecha- nism of easy-to-ionize and hard-to-ionize elements in ICP-AES Guangpuxue Yu Guangpu Fenxi 1992 12 54. (Dept. Chem. Hankai Univ. Tianjin 300071 China). 9314010. Yang J.-f. Piao Z.-x. Zeng X.-j. Determination of trace lanthanum cerium samarium aluminium lead and copper in high-purity yttrium oxide with ICP-AES 93/40] 1. 93/40 1 2. 93/4013. 93/40 14. 93/40] 5. 93/40 16. 93/40 17. 93/40 1 8. 93/40 19. 93/4020. Guangpuxue Yu Guangpu Fenxi 1992 12 60. (Changchun Inst. Appl. Chem. Acad. Sin. Changchun 130022 China). Wang S.-y. Liu J. Direct determination of fourteen elements in copper alloy with mixed rare earths by ICP- AES Guangpuxue Yu Guangpu Fenxi 1992 12 67.(Changchun Inst. Appl. Chem. Acad. Sin. Changchun 130022 China). Wang J.-f. Wei Y.-j. Ren J.-m. Ding R.-q. Detenni- nation of rare earth elements and scandium in phos- phate rocks by ICP-AES Guangpuxue Yu Guangpu Fenxi 1992 12 72. (Dept. Chem. He Bei Teach. Coll. Shijiazhuang 05009 1 China). Zhou J.-k. Zhang Y. Liu D.-m. Enhancement effect in flame atomic absorption spectrometry Guangpuxue Yu Guangpu Fenxi 1992,12,98. (Dept. Chem. Shanxi Univ. Taiyuan 030006 China). Li S.-z. Zheng S.-y. Liu G.-b. Fan J.-l. Comparison of pre-treatment methods for the determination of lead in serum by graphite furnace atomic absorption spectro- metry Guangpuxue Yu Guangpu Fenxi 1992 12 103. (Dept. Chem. Hebei Norm.Univ. Shijiazhuang 0500 I 6 China). Yang P. Determination of molybdenum in rice by graphite furnace atomic absorption spectrometry using calcium chloride as matrix modifier and vacuum lan- thanum-coated tubes Guangpuxue Yu Guangpu Fenxi 1992 12 116. (Sichuan Res. Monit. Inst. Environ. Prot. Chengdu 6 1004 1 China). Zhai G.-x. Determination of copper lead and cad- mium in river water by concentration with sulfhydryl cotton fibre Guangpuxue Yu Guangpu Fenxi 1992,12 1 19. (Yangtze River Resour. Prot. Bur. Wuhan 43005 1 China). Wang M.-l. Chen G.-p. Atomic absorption determina- tion of lithium in human blood saliva and urine Guangpuxue Yu Guangpu Fenxi 1992 12 123. (Dept. Chem. Huizhou Teach. Coll. Huangshan 24502 1 China). Fan P.-z. Zhang Z.-q. Zhou J.-z. Jin R.-s.Xu Z.-z. Guo X. Stigmatic grazing incidence flat-field grating spectrography and its application in XUV spectroscopic diagnostics of plasmas Guangxue Xuebao 1992 12 118. (Shanghai Inst. Opt. Fine Mech. Acad. Sin. Shanghai 20 1800 China). Hara A. Senarita M. Komeno M. Kusakari J. Metallic elements in the perilymph measured with an inductively coupled plasma atomic emission spectro- meter Hear. Rex 1992 59 117. (Inst. Clin. Med. Univ. Tsukuba Tsukuba 305 Japan). Wu W.-t. Niu Y. Guo J.-t. Zhang Y.-s. Sulfate induced corrosion behaviour of iron aluminide (FeA1) intermetallic compound in oxygen-0.5O/o (sulfur dioxide+ sulfur trioxide) atmosphere at 600-870 "C High Temp. Corros. Adv. Mater. Prot. Coat. Proc. Workshop 1990,301. (Inst. Corros. Protect. Met. Acad. Sin.Shenyang 1 100 15 China). 93/402 1. Qin G.-y. Li S. Moessbauer study of Chinese ancient mineral drugs Hyperfzne Interact. 1992,70( 1-4) 104 1. (Dept. Phys. Zhengzhou Univ. Zhengzhou 450052 China). 9314022. Yoshida D. Ikeda Y. Nakazawa S. Tissue concentra- tions of copper and zinc in human brain tumors Igaku no Ayumi 1992 161 269. (Dept. Neurosurg. Nippon Med. Sch. Tokyo 11 3 Japan). 9314023. Anwari M. A. Tuncel G. Ataman 0. Y. Lead and nickel levels in Black Sea aerosols by ETAAS Int. J. Environ. Anal. Chem. 1992 47 227. (Dept. Chem. Middle East Tech. Univ. Ankara 06531 Turkey). 9314024. Rubio R. Sahuquillo A. Rauret G. Quevauviller P. Determination of chromium in environmental andJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 401R 9314025.9314026. 931402 7. 9314028. 9314029. 9314030. 931403 1. 9314032. 9314033. 9314034. 931403 5. 9314036. 9314037. 9 31403 8. 9314039. biological samples by atomic absorption spectroscopy a review Int. J. Environ. Anal. Chem. 1992 47 99. (Dept. Anal. Chem. Univ. Barcelona Barcelona E-08028 Spain). Rashed M. N. Determination of trace elements in milk of some animals from Aswan (Egypt) Int. J. Environ. Anal. Chem. 1992 48 41. (Dept. Chem. High Dam Lake Dev. Author. Aswan Egypt). Cavallaro S. Freni S. Cannistraci R. Aquino M. Giordano N. Alkali effect on the MCFC-internal reforming catalyst life Int. J. Hydrogen Energy 1992 17 181. (Dipt. Chim. Ind. Univ. Messina 98166 Sant’Agata Italy). MiIler-Ihli N. J. Greene F. E. Graphite furnace atomic absorption method for the determination of chromium in foods and biological materials J.AOAC Int. 1992 75 354. (Nutr. Comp. Lab. U.S. Dept. Agric. Beltsville MD 20705 USA). Krustev S. Ivanov K. Klissurski D. Preparation of manganous(I1) tungstate by a precipitation method J. Alloys Compd. 1992 182 189. (Dept. Chem. Agrar. Univ. Plovdiv Bulgaria). Ewing K. J. Jaganathan J. Peitersen L. Aggarwal I. D. Sommers J. A. Fahey J. V. Radiotracer study of the preparation of high-purity lanthanum fluoride J. Am. Ceram. SOC. 1992 75 1562. (Nav. Res. Lab. Washington DC 20375-5000 USA). Bernacca G. M. Fisher A. C. Wilkinson R. Mackay T. G. Wheatley D. J. Calcification and stress distribu- tion in bovine pericardial heart valves J. Biomed. Mater. Res. 1992 26 959. (Bioeng. Unit Univ. Strathclyde Glasgow UK G40NW).Quest A. F. G. Bloomenthal J. Bardes E. S. G. Bell R. M. Regulatory domain of protein kinase C co- ordinates four atoms of zinc J. Biol. Chem. 1992 267 10193. (Med. Cent. Duke Univ. Durham 27710 USA). Balkose D. Baltacioglu H. Adsorption of heavy metal cations from aqueous solutions by wool fibres J. Chem. Technol. Biotechnol. 1992 54 393. (Fac. Eng. Ege Univ. Izmir Turkey). Liou D.-c. Lou Y.-c. Whang C.-w. Determination of trace butyltin compounds in sea-water by gas chromato- graphy atomic absorption spectrometry J. Chin. Chem. SOC. (Taipei) 1992 39 217. (Dept. Chem. Tunghai Univ. Taichung 40704 Taiwan). Ombaba J. M. Barry E. F. Determination of organo- tin species by capillary gas chromatography with alternating current plasma emission detection J.Chromatogr. 1992 598 97. (Dept. Chem. Univ. Massachusetts Lowell MA 0 1854 USA). Bostic D. Burns G. Harvey S. Qualitative corrosion monitoring by on-line ion chromatography J. Chroma- togr. 1992,602 163. (Surry Power Stn. Virginia Electr. and Power Co. Surry VA 23883 USA). Klemp M. Puig L. Trivedi K. Sacks R. Characteriza- tion of a low-pressure microvolume plasma emission detector for gas chromatography J. Chromatog, Sci. 1992 30 136. (Dept. Chem. Univ. Michigan Ann Arbor MI 48109 USA). Chang S. B. Siew C. Gruninger S. E. Factors affecting blood mercury concentrations in practicing dentists J. Dent. Res. 1992 71 66. (Res. Inst. Am. Dent. Assoc. Chicago IL 606 1 1 USA). Zantopoulos N. Antoniou V. Tsoukali-Papadopoulou H. Lead concentrations in plants and animal tissues J.Environ. Sci. Health Part A 1992 27 1453. (Vet. Inst. Infect. Parasit. Cent. Vet. Inst. Thessaloniki Thessalo- niki 54627 Greece). Grijalva M. I. Valencia M. E. Wyatt C. J. Sodium potassium and calcium intake in adults consuming 9314040. 931404 1. 9314042. 9 314043. 9314044. 9314045. 9314046. 9314047. 9314048. 9314049. 9 3/40 50. 931405 1. 93/40 52. 9 3/40 5 3. normal diets in northern Mexico determined by analyti- cal and calculated methods J. Food Compos. Anal. 1992 5 127. (Cent. Invest. Aliment. Desarrollo Nutr. Div. Hermosillo Mexico). Akinpelu 0. A. Iron and copper uptake during the wet- milling of some Nigerian foods J. Food Sci. Technol. 1992 29 108. (Food Sci. Technol. Unit Polytech. Ibadan Nigeria). Trassy C. Chomet S. Vardelle M. Evaluation of temperature and concentration in vapour cloud of powder in a thermal plasma. Fundamental aspects and signal treatment J.High Temp. Chem. Processes 1992 1 91. (Lab. Phys.-Chim. Ind. INSA 69621 Villeur- banne France). Ackland M. L. Mercer J. F. B. Murine mutation lethal milk results in production of zinc-deficient milk J. Nutr. 1992,122 1214. (Scobie and Claire Mackinnon Trace Elem. Lab. Murdoch Inst. Parkville 3052 Australia). Xu Z.-x. Tang J.-p. Badr M. Melethil S. Kinetics of aluminium in rats. 111 effect of route of administration J. Pharm. Sci. 1992 81 160. (Sch. Pharm. Univ. Missouri Kansas City MO 64108 USA). Fitzgerald E. A. Almeida R. F. Determination of trace metals in positive photoresists J. Electrochem. SOC. 1992 139 14 13. (OCG Microelectron. Mater.Provi- dence RI 02914 USA). Bobulescu R. C. Bratescu M. A. Stanciulescu C. Musa G. On a new method in spectroscopy laser- induced frequency shift of self-excited ion oscillations J. Phys. III 1992 2 1367. (Fac. Phys. Univ. Bucharest BucharestlMagurele Rumania). Sohns E. Kock M. Plasma diagnostics based on self- reversed lines. I. Model calculation and application to argon arc measurements in the near-infrared and vacuum ultraviolet regions J. Quant. Spectrosc. Radiat. Transfer 1992 47 325. (Inst. Plasmaphys. Univ. Hannover D-3000 Hannover 1 Germany). Sohns E. Kock M. Plasma diagnostics based on self- reversed lines. 11. Application to nitrogen carbon and oxygen arc measurements in the vacuum ultraviolet J. Quant. Spectrosc. Radiat. Transfer 1992 47 335. (Inst. Plasmaphys.Univ. Hannover D-3000 Hannover Germany). Dong J. Kearney R. J. Plasma gas velocities in an argon jet at atmospheric pressure J. Quant. Spectrosc. Radiat. Transfer 1992 48 105. (Dept. Phys. Univ. Idaho Moscow ID 83843 USA). Simeonsson J. B. Ng K. C. Winefordner J. D. Fluorescence-dip spectroscopy as a method for measur- ing the quantum efficiency of fluorescence J. Quant. Spectrosc. Radiat. Transfer 1992 48 13 1. (Dept. Chem. Univ. Florida Gainesville FL 326 1 1-2046 USA). Sansonetti J. E. Reader J. Sansonetti C. J. Acquista N. Atlas of the spectrum of a platinumlneon hollow cathode reference lamp in the region 1130-4330 A J. Res. Natl. Inst. Stand. Technol. 1992 97 1. (Natl. Inst. Stand. Technol. Gaithersburg MD 20899 USA). Blaise J. Verges J. Wyart J.F. Engleman R. Jr. Energy levels of neutral platinum J. Res. Natl. Inst. Stand. Technol. 1992 97 213. (Lab. Aime Cotton CNRS F-9 1405 Orsay France). Blaise J. Wyart J. F. Energy levels of singly ionized platinum J. Res. Natl. Inst. Stand. Technol. 1992 97 217. (Lab. Aime Cotton CNRS 11 F-91405 Orsay France). Kamei M. Aoki Y. Usui T. Morishita T. In situ X-ray chemical analysis of yttrium barium copper oxide (YBa2Cu30,-,) films by reflection high-energy electron diffraction total reflection angle X-ray spectroscopy,402R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 9314054. 9 31405 5. 9314056. 93/405 7. 931405 8. 9 31405 9. 9314060. 931406 1. 9314062. 9 31406 3. 9314064. 931406 5. 9314066. 9 31406 7. 9 314068. 9 314069. Jpn. J. Appl. Phys.Part I 1992 31 1326. (Supercond. Res. Lab. ISTEC Tokyo Japan 135). Fujimori H. Matsui T. Ajiro T. Yokose K. Hsueh Y. M. Izumi S. Detection of fine particles in liquids by laser breakdown method Jpn. J. Appl. Phys. Part I 1992 31 1514. (Energy Res. Lab. Hitachi Ltd. Hitachi Japan 3 16). Sohma K. Measurement of the spatial distribution of flame emission intensities Kagaku Kogaku 1992 56 56 1. (Hitachi Seisakusho K. K. Japan). Yasuhara A. Nakasugi O. Analysis of chemical com- ponents in landfill leachate. Part 1 Kankyo Kagaku 1992 2 25. (Natl. Inst. Environ. Stud. Tsukuba 305 Japan). Poluyanov V. P. Extraction of tin from soil by using crown ethers Khim. Sel’sk Khoz. 1992 4 99. (Voen- naya Inzh. Radiotekh. Akad. USSR). Nakamura E. Namiki H. Sakurabayashi N. Determi- nation of cadmium copper and lead in water by graphite furnace atomic absorption spectrophotometry after extraction with DDTC-benzene Kogyo Yosui 1992 404 9.(Fac. Educ. Yokohama Natl. Univ. Yokohama 240 Japan). Umezaki Y. Electrothermal atomic absorption spectro- metry Kogyo Yosui 1992,405,40. (Ind. Pollut. Control Assoc. Japan Tokyo 1 10 Japan). Miyazaki A. Inductively coupled plasma emission spectrometry Kogyo Yosui 1992 405 48. (Natl. Inst. Resour. Environ. Tsukuba 305 Japan). Pohl B. Horstkottke B. Steeg U. Determination of arsenic and selenium by atomic absorption spectroscopy (AAS). Use of high-performance hollow cathode lamps LaborPraxis 1992 16 230. (Varian GmbH W-6 100 Darmstadt 1 1 Germany). Elspass R. Milestone in atomic absorption spectro- scopy SOLAAR-AAS made to measure for the user LaborPraxis 1992 16 328 330.(Unicam Anal. Syst. W-3500 Kassel Germany). Jiao F. Zhang G. AES analysis of aluminium bronzes for major constituents and impurities Lihua Jianyan Huaxue Fence 1992 28( l) 2 1. (Shenyang Nonferrous Met. Process. Plant Shenyang 110102 China). Zou B. Liang J.-b. Ruan Y.-h. Yang X.-g. Flame atomic absorption spectroscopic determination of cop- per iron zinc manganese calcium magnesium nickel and cobalt in Amorphophallus Lihua Jianyan Huaxue Fence 1992,28( l) 30 32. (Shaanxi Prov. Ankang Dist. Public Health Antiepidemic Stn. China). Hu H.-r. Determination of silver in natural silver- containing ores Lihua Jianyan Huaxue Fence 1992 28(1) 54. (Inst. Geol. Liaoning Geol. Explan. Bur. China). Yuan J.-b. Yuan S.-z.Determination of traces of silver by AAS using a quartz boat Lihua Jianyan Huaxue Fence 1992 28(1) 57 59. (Hunan Prov. Bur. Geol. Min. China). Cai S. Treatment of sample solution for colloidal matter before preconcentration of gold on an activated carbon column Lihua Jianyan Huaxue Fence 1992 28(1) 61. (Nanjing Compr. Rock Anal. Cent. Minist. Geol. Min. Nanjing China). Meisinger V. Biochemical analysis of magnesium Magnesium Bull. 1992,14 2. (Univ. Klin. Arbeitsmed. Vienna Austria). Bezur L. Varga J. Pungor E. Evaluation of metal- contaminated waste using the cup flame atomic absorp- tion spectrometry method Microchem. J. 1992,46 82. (Dept. Gen. Anal. Chem. Tech. Univ. Budapest H- 1 52 1 Budapest Hungary). 93/4070. 931407 1. 9314072. 9314073. 9314074. 9314075.9314076. 931407 7. 9 314078. 9314079. 9314080. 931408 1. 9 314082. 9 31408 3. Santarsiero A. Ottaviani M. Heavy metals in residues from hospital solid waste incineration Microchem. J. 1992 46 100. (1st. Super. Sanita 00161 Rome Italy). Hlavay J. Analysis of respirable dust Microchem. J. 1992 46 121. (Dept. Anal. Chem. Univ. Veszprem H-820 1 Veszprem Hungary). Livingstone A. Jackson B. Davidson P. J. Zinc analogue of schulenbergite from Ramsbeck Germany Mineral. Mag. 1992 56 215. (Dept. Geol. R. Mus. Scotland Edinburgh UK EH 1 1 JF). Barbera R. Fang T. Y. Garcia Andion P. Direct determination of lead in cola beverages by electrother- mal atomic absorption spectrophotometry Nahrung 1992 36 202. (Dept. Nutr. Food. Chem. Univ. Valencia Valencia 460 I0 Spain).Vukicevic S. Kracun I. Vukelic Z. Krempien B. Rosner H. Cosovic C. 24R,25-dihydroxyvitamin D3 prevents aluminium-induced alteration of brain ganglio- sides in uremic rats by keeping the metal within perivascular astrocytes of the blood-brain barrier Neu- rochem. Int. 1992 20 391. (Sch. Med. Univ. Zagreb Zagreb Yugoslavia). Muramoto J. Goto I. Ninaki M. Application of inductively coupled plasma atomic emission spectro- metry (ICP-AES) to soil analysis. 6. Rapid analysis of exchangeable cations ad cation-exchange capacity (CEC) of soils by a shaking extraction method Nippon Dojo Hiryogaku Zasshi 1992 63(2) 210. (Fac. Agric. Tokyo Univ. Agric. Tokyo Japan 156). Goto I. Muramoto J. Ninaki M. Analysis of minerals in plant by closed PTFE vessel acid digestion method and ICP-AES Nippon Dojo Hiryogaku Zasshi 1992,63 345.(Tokyo Univ. Agric. Tokyo Japan 156). Sugimoto F. Tsunekage N. Maeda Y. Determination of trace amounts of chromium(v1) in natural water by graphite furnace atomic absorption spectrometry after zinc-diethyldithiocarbamate coprecipitation dissolu- tion in ethyl acetate Nippon Kagaku Kaishi 1992 6 667. (Dept. Appl. Chem. Himeji Inst. Technol. Himeji 67 1-22 Japan). Negishi A Tsurumi C. Determination of titanium in high-alloy steels and iron sand by atomic absorption spectrometry after solvent extraction with benzene solution of Amberlite LA-2 Nippon Kagaku Kaishi 1992 6 683. (Dept. Ind. Chem. Shibaura Inst. Tech- nol. Tokyo 108 Japan). Uesugi K. Suehiro S. Nishioka H. Kumagai T. Nagahiro T. Determination of nickel in sea-water and common salt by atomic absorption spectrophotometric method with 5-nitrosalicylaldehyde-4-phenyl-3-thio- semicarbazone extraction Nippon Kaisui Gakkaishi 1992 46 22.(Fac. Technol. Himeji Inst. Technol. Himeji 67 1-22 Japan). Yang M. H. Lee M. L. Hwang H. L. Precise compositional and trace-elemental analysis by chemical methods in compound semiconductors Non-Stoichiom. Semicond. Proc. Symp. A3 Int. Con$ Adv. Mater. 1991 (Pub. 1992) 15. (Inst. Nucl. Sci. Natl. Tsing Hua Univ. Hsinchu Taiwan). Smirnova E. V. Chikalina V. K. Golovko S. B. Use of double-jet arc plasmatron in atomic emission analysis of geological samples for tantalum and niobium Nov. Metody Anal. Vysokochist. i Tekhn. Mater. AN SSSR. SO. In-t Neorgan. Khimii Novosibirsk 1990 207. (USSR). Anderson R.R. Variations in major minerals of human milk during the first 5 months of lactation Nutr. Rex (N. Y.) 1992 12 701. (Dept. Anim. Sci. Univ. Missouri Columbia MO 652 1 1 USA). Fischer S. Modern instrumental metal analysis methods in comparison atomic absorption spectros- copy (AAS) and inductively coupled plasma atomicJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 403R 9314084. 9314085. 9 31408 6. 9314087. 931408 8. 9314089. 9314090. 931409 1. 9314092. 9314093. 9314094. 9 31409 5. 9314096. 9 31409 7. emission spectroscopy ICP-AES Oesterr. Chem. Z . 1992 93 73. (A-10 10 Vienna Austria). Gavrilov V. E. Diagnostics and continuum of a slightly non-ideal neon plasma radiation Opt. Spektrosk. 1992 72 16. (Gos. Opt. Inst. St. Petersburg Russia). Saida J.Ghafari M. Nakamura Y. Moessbauer study of iron-boron and (iron,cobalt,nickel)-boron ultra-fine amorphous powders prepared by chemical reduction Ordering Disord. Alloys [Proc. Eur. Workshop Ordering Disord.] 1992 462. (Surf. Treat. Dept. Nisshin Steel. Sakai Japan 592). Myashita F. Highly sensitive determination of tin by flameless atomic absorption spectrometry Jpn. Kokai Tokkyo Koho JP 04 95,855 [92 95,8551 (Cl. GOlN21/31) 27 Mar 1992 Appl. 901214,197 10 Aug 1990; 3 pp. (Shimazu Seisakusho K. K. Japan). Kawamura S. Koshu Y. Sekimoto M. Kobayashi Y. Surface analysis of ultra-thin samples with adhesives Jpn. Kokai Tokkyo Koho JP 03,255,939 [91,255,939] (Cl. GOlN21/67) 14 Nov 1991 Appl. 90153,732 07 Mar 1990; 4 pp. (Kawasaki Steel Corp. Japan).Murao K. Shiromizu Y. Removal of boron from air Jpn. Kokai Tokkyo Koho JP 04,14 1,240 [92,14 1,2401 (Cl. BOlL1104) 14 May 1992 Appl. 90/260,418,01 Oct 1990; 2 pp. (Fujitsu Japan). Sado N. Taniguchi M. Analysis of alumina-titanium carbide ceramic for magnetic head slider in recording apparatus Jpn. Kokai Tokkyo Koho JP 04 86,556 [92 86,5561 (Cl. GOlN33/38) 19 Mar 1992 Appl. 90/201,987 30 Jul 1990; 6 pp. (Fuji Denki K. K. Japan). Kosaka M. Taniguchi O. Funato Y. Determination of trace germanium by flameless atomic absorption spectrometry Jpn. Kokai Tokkyo Koho JP 04,134,249 [92,134,249] (Cl. GO 1 N2 113 l) 08 May 1992 Appl. 901260,060 27 Sep 1990; 3 pp. (Shimadzu Corp. Japan). Griem H. R. Plasma spectroscopy in inertial confine- ment fusion and soft X-ray laser research Phys.Fluids B 1992 4 2346. (Lab. Plasma. Res. Univ. Maryland College Park MD 20742 USA). Baier W. R. Kosmus W. Heinrich G. Sodium magnesium potassium and calcium in plant latexes Phyton (Horn Austria) 1992 31 227. (Inst. Pflanzen- physiol. Univ. Graz A-80 10 Graz Austria). Golovitskii A. P. Possibility of creating efficient UV radiation based on a continuous glow discharge in mixtures of inert gases and halogens Pis’ma Zh. Tekh. Fiz. 1992 18(8) 73. (St. Petersburg Tekh. Univ. St. Petersburg Russia). Meiri A. Silk W. K. Lauchli A. Growth and deposition of inorganic nutrient elements in develop- ment leaves of Zea mays L Plant Physiol. 1992 99 972. (Dept. Land Air Water Resour. Univ. California Davis CA 95616 USA). Kalantary M. R. Holbrook K. A. Wells P. B.Effects of agitation on conventional electroless plating implica- tions for production of nickel-phosphorus composite coatings Plat. Surf Finish. 1992 79(8) 55. (Univ. Hull Hull North Humberside UK HU6 7RX). Wong A. S. Robertson J. D. Multi-elemental analysis of Argonne premium coal samples by simultaneous proton-induced gamma-ray-X-ray emission spectrome- try Prepr. Pap.-Am. Chem. SOC. Div. Fuel Chem. 1992 37 11 17. (Cent. Appl. Energy Res. Univ. Ken- tucky Lexington KY 40506-0055 USA). Rathmann D. Fabry L. Determination of inorganic trace contamination on thermoplbstic carrier surface by ion chromatography Proc. Electrochem. SOC. 1992,92 344. (Wacker-Chemitronic GmbH D-8263 Burghausen Germany). 93/4098. 9314099. 9314 100. 9314 10 1. 93/4 102. 9314 103. 9314 104.9314 105. 9314 106. 9314107. 9314 9314 9314 08. 09. 10. 93/41 11. 93/4 I 12. Montaser A. Tetreault C. Linder M. Comparison of copper binding components in dog serum with those in other species Proc. SOC. Exp. Biol. Med. 1992,200,321. (Inst. Mol. Biol. Nutr. California State Univ. Fuller- ton CA 92634 USA). Ooka N. Honjo T. Terada K. Preconcentration and determination of a trace amount of lithium in water as its thenoyltrifluoroacetone complex with tributylphos- phate by means of solvent extraction and flame photo- metry Process Metall. 1992 7A 457. (Fac. Sci. Kanazawa Univ. Kanazawa 920 Japan). Seijas M. V. Gil A. Munoz M. T. Lozano R. Direct determination of selenium by graphite furnace atomic absorption spectrometry with deuterium background correction Recent Dev.Ther. Drug Monit. Clin. Toxi- col. 1992 271. (Hosp. Ramon. Cajal de Madrid Madrid Spain). Dolejskova J. Horak V. Bures R. Determination of mercury content in organs of broiler using Hg-monitor TMA-254 Sb. Vys. Sk. Zemed. Praze Fak. Agron. Rada B 1992 54 11. (Sb. Vys. Sk. Zemed. Prague Czechoslovakia). Dolejskova J. Horak V. Koudela K. Mercury content in feathers of broilers after acute intoxication with inorganically and organically bound mercury Sb. Vys. Sk. Zemed. Praze Fak. Agron. Rada B 1992 54 19. (Vys. Sk. Zemed. Prague Czechoslovakia). Schuhmacher M. Domingo J. L. Llobet J. M. Corbella J. Lead concentration and d-aminolevulinic acid dehydratase activity in the blood of the general population of Tarragona Province Spain Sci. Total. Environ. 1992 116 253.(Sch. Med. Univ. Barcelona Reus 43201 Spain). El Hinshery A. K. Kumar N. S. Lead levels in settled dusts of Tripoli Libya Sci. Total. Environ. 1992 119 51. (Pet. Res. Cent. Tripoli Libya). Minoia C. Pietra R. Sabbioni E. Ronchi A. Gatti A. Cavalleri A. Manzo L. Trace element reference values in tissues from inhabitants of the European Commu- nity. 111. Control of preanalytical factors in the biomoni- toring of trace elements in biological fluids Sci. Total Environ. 1992 120 63. (Lab. Ig. Ind. Fond. Clin. Lavoro 27 100 Pavia Italy). Gil’bert E. N. Shabanova L. N. Modern multi-element methods of analysis of environmental samples Sib. Khim. Zh. 1992 3 5. (Inst. ‘Gidrotsvetmet’ Novo- sibirsk USSR). Chittleborough D. J. Hotchin D. M. Beckett R. Sedimentation field-flow fractionation a new technique for the fractionation of soil colloids Soil Sci.1992,153 341. (Waite Agric. Res. Inst. Univ. Adelaide Australia). Poluyanov V. P. Method of arsenic detection in biological material Sud. Med. Ekspert. 1992 35 31. (Moscow USSR). Broekaert J. A. C. Use of ICP atomic spectrometry for water analysis Tech. Mess. 1992,59 147. (Fachbereich Chem. Univ. Dortmund W-4600 Dortmund 1 Ger- many). Kinoshita M. Takai M. YAG laser induced photo- emission of metals and dyes Technol. Rep. Kansai Univ. 1992 34 39. (Eng. Coll. Kansai Univ. Osaka Japan). Von der Linde D. Ultrafast spectroscopy of plasmas generated by very intense femtosecond dye laser pulses Top. Appl. Phys. 1992 70 225. (Inst. Laser Plasma- phys. Univ. GH Essen Essen Germany). Zu Putlitz G.Beau M. R. Dye laser spectroscopy of isolated atoms and ions in liquid helium Top. Appl. Phys. 1992 70 237. (Phys. Inst. Univ. Heidelberg W-6900 Heidelberg 1 Germany).404R JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY DECEMBER 1993 VOL. 8 9314 1 13. 9314 1 14. 9314 1 15. 93141 16. 9314 1 17. 93141 18. 9314 1 19. 9314 120. 9314 12 1. 9314122. Pineau A. Durand C. Guillard O. Bureau B. Stalder J. F. Role of aluminium in skin reactions after diphtheria-tetanus-pertussis-poliomyelitis vaccina- tion an experimental study in rabbits Toxicology 1992 73 117. (Lab. Toxicol. Hyg. Ind. Fac. Pharm. 44035 Nantes France). Picurelli L. Olcina P. V. Roig M. D. Gunthner S. Ferrer J. Determination and relationship of the iron and magnesium concentrations in normal and patholo- gic prostatic tissue Trace Elem.Med. 1992,9 14. (Coll. Sci. Univ. Valencia Valencia Spain). Kisters K. Spieker C. Bertram H. P. Rahn K. H. Zidek W. Aluminium concentrations in lymphocytes of patients on regular haemodialysis treatment Trace Elem. Med. 1992 9 25. (Med. Univ. Policlin. W-4400 Munster Germany). Vasikaran S. D. Patel S. O’Gorman P. Zinc and copper status of lead workers Trace Elem. Med. 1992 9 103. (Med. Sch. Univ. Sheffield Sheffield UK S 10 2RX). Osojnik A. Drglin T. Trace element determination in steel and vacuum cast superalloys Vacuum 1992 43( 5-7) 7 17. (Inst. Met. Technol. Ljubljana 6 1000 Slovenia). Zolotukhina E. Yu. Tropin I. V. Kononenko R. V. Distribution of heavy metals in thallus of the brown alga Laminaria saccharina (Ag.) Kjellm Vestn. Mosk. Univ. Ser. 16 Biol. 1992 1 72. (USSR).Dobrowolski R. Mierzwa J. Application of activated carbon for the enrichment for some heavy metals and their determination by atomic spectrometry Vestn. Slov. Kem. Drus. 1992 39 55. (Cent. Lab. M. Curie- Sklodowska Univ. 20-03 1 Lublin Poland). May J. C. Rains T. C. Yu L. J. Etz N. M. Aluminium content of source plasma and sodium citrate anticoagulant VOX. Sang. 1992 62 65. (Cent. Biol. Eval. Res. Food and Drug Adm. Bethesda MD USA). Gremm T. J. Frimmel F. H. Determination of organotin compounds in aqueous samples by means of HPGC-AED Water Res. 1992 26 1163. (Engler- Bunte-Inst. Univ. Karlsruhe D-7500 Karlsruhe Germany). Guyette R. P. Cutter B. E. Henderson G. S. Inorganic concentrations in the wood of eastern redcedar grown 9314 123. 9314 124. 9314 125. 9314126. 9314 127. 93141 28.9314129. 93141 30. 9314131. on different sites Wood Fiber Sci. 1992 24 133. (Sch. Nat. Resourc. Univ. Missouri Columbia MO 652 1 1 USA). Chen J.-r. Jin H. Zhou Z.-r. Tang F.-l. Flame atomic absorption spectrophotometric determination of gold in ores after preconcentration with trioctylphos- phine oxide (TOP0)-impregnated resin Yejin Fenxi 1992 12 53. (Dept. Chem. Zhejiang Norm. Univ. Jinhua 32 1004 China). Yang W,. Qian Y.-q. Zheng D.-y. Feeding patterns and zinc and copper nutriture of infants from 1 to 3 months Yingyang Xuebao 1992 14 81. (2nd. Univ. Hosp. West China Univ. Med. Sci. Chengdoou 6 10004 1 China). Vaessen H. A. M. G. Van de Kamp C. G. Szteke B. Aluminium determination in food matrixes. IUPAC collaborative survey of analytical performance 2. Le- bensm.-Unters.Forsch. 1992 194 456. (Lab. Residue Anal. Natl. Inst. Public Health Prot. 3720 BA Biltho- ven The Netherlands). Brodyanskaya N. N. Tarasova E. G. Val’gas I. V. Taking into account the effect of third elements with the Kvantan program Zavod. Lab. 1992 58 58. (Russia). Tarasova E. G. Vel’gas I. V. Senina E. A. Implemen- tation of Bird DV4 quantometers Zavod. Lab. 1992 58 62. (Russia). Meyer J. Geuenich H. H. Robra B. P. Windorfer A. Determinations of lead in umbilical cord blood in 9 189 newborns in the district of Braunschweig Germany Zentralbl. Hyg. Umweltmed. 1992 192 522. (Kreisk- rankenhaus Wittmund Wittmund Germany). Yin L.-f. Jing C.-y. Zhang G.-y. Lin FA. Optogal- vanic spectrum in uranium hollow cathode discharge Zhongguo Jiguang 1992 19 107. (Shanghai Inst. Opt. Fine Mech.Acad. Sin. Shanghai China). Jiao S.-l. Chen S.-s. Fan Y.-c. Li Z.-g. Experimental study of the plasma ejected by pulsed laser from a solid surface Zhongguo Jiguang 1992 19 205. (Natl. Lab. Laser Technol. Huazhong Univ. Sci. Technol. Wuhan China). Cupka P. Effects of age on the change in sodium potassium and calcium levels in the blood serum of calves Zivocisna Vyroba 1992 37 125. (Vys. Sk. Polnohospod. 949 76 Nitra Czechoslovakia).
ISSN:0267-9477
DOI:10.1039/JA993080377R
出版商:RSC
年代:1993
数据来源: RSC
|
|