|
1. |
Determinants of Susceptibility to Experimental Enterococcal Pyelonephritis |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 109-124
E.A. Rutsky,
J.R. Clapp,
R.R. Robinson,
Preview
|
PDF (1928KB)
|
|
摘要:
The incidence of parenchymal renal infection after the hematogenous administration of enterococci was ascertained in the rat during several experimental conditions (spontaneous antidiuresis, water deprivation plus oral loading with acid or alkali, water-loading alone, and water-loading plus oral acid or alkali). Differences in the incidence of infection were related to the presence or absence of volume contraction (or some function thereof), or variations of medullary tonicity and/or ammonia concentration in similarly treated but nonchallenged control rats. The results are summarized below: Experimental rats Control rats
ISSN:1660-8151
DOI:10.1159/000179913
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
2. |
La mesure du débit sanguin rénal par thermodilution locale artérielle |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 125-146
P.P. Lambert,
R.J. Kahn,
P. Gottignies,
J.L. Vanherweghem,
R. Fafchamps,
Preview
|
PDF (2220KB)
|
|
摘要:
Chez le chien, le flux artériel rénal peut être mesuré très correctement par thermodilution locale lorsque le débit est supérieur à 100 ml/min. En dessous de cette valeur l’erreur risque d’etre supérieure à ± 10% dans un tiers des cas. Une détermination correcte exige 5 mesures successives à 1 min d’intervalle. Avec les sondes ci-dessous décrites, l’injection intra-artérielle de soluté froid entraîne une réduction du débit témoignant de la mise en jeu du mécanisme d’autorégulation du débit rénal. Survenant après 10–15 sec, sa durée n’excédant pas 30 sec, ce phénomène n’a pas d’effet sur les mesures en raison de leur rapidité et pour autant qu’elles soient espacées d’une minute au moins. La mesure du flux exige la détermination préalable du facteur de réchauffement de l’injectat. Celle-ci peut se faire dans une expérience préliminaire comportant la mesure simultanée du débit veineux rénal dans une colonne graduée. Ce facteur est caractéristique de la sonde utilisée et de la voie d’accès du vaisseau rénal. Les résultats montrent que dans les conditions de nos expériences, le calcul du débit rénal par thermodilution artérielle nécessite le recours à la correction dit; «veineuse» proposée par Fronek et Ganz [3], pour tenir compte de l’augment
ISSN:1660-8151
DOI:10.1159/000179914
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
3. |
L’estimation de la filtration glomérulaire par l’EDTA51Cr |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 147-155
B. Francois,
N. Pozet,
B. Rattanachane,
J. Traeger,
Preview
|
PDF (940KB)
|
|
摘要:
Des mesures simultanées des clearances urinaires du complexe 51Cr EDTA et du thiosulfate (valeur référentielle de la filtration glomérulaire) ont été effectuées chez 32 sujets atteints de néphropathies diverses. La clearance de l’EDTA est en moyenne de 91% celle du thiosulfate pour des valeurs normales de la filtration, mais de 99% pour des filtrations comprises entre 10 et 90 ml/min. Cette différence de comportement indépendante des variations de débit urinaire, est liée à la qualité des fonctions lénales; une équation est apportée, qui permet de corriger la valeur observée de la clearance de 51Cr EDTA au dessus de 40 ml/min. La variabilité intra-individuelle de chacune des deux clearances chez les sujets à filtration normale et la variabilité inter-individuelle du rapport des clearances chez les sujets normaux et les sujets pathologiques sont identiques. La variabilité intra-individuelle du rapport des clearances est faible et indépendante de la
ISSN:1660-8151
DOI:10.1159/000179915
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
4. |
Renal Transport of Diatrizoate in the Rabbit, Dog, and Rat |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 156-172
G.H. Mudge,
W.O. Berndt,
A. Saunders,
B. Beattie,
Preview
|
PDF (1703KB)
|
|
摘要:
The renal transport of 125I-diatrizoate was examined in three species, dog, rabbit, and rat. In the rabbit this organic acid behaved like many such compounds, i.e. it was secreted by the proximal tubular organic anion process as judged by stop-flow analysis. The proximal tubular peak was abolished by probenecid. In vitro experiments with renal cortex slices gave results entirely consistent with the in vivo studies. Diatrizoate uptake by the slices was an energy-dependent, saturable process that was blocked by several organic acids known to be accumulated by the organic acid transport system. Rat renal cortex slices showed significant diatrizoate uptake, although of a lesser magnitude than noted with rabbit tissue (rat S/M = 1–2; rabbit S/M = 3–5). Except for the failure of acetate to stimulate diatrizoate uptake, accumulation by the rat slices appeared to be by the organic acid transport process. On the other hand, dog slices failed to accumulate diatrizoate. The process was not stimulated by acetate or any other metabolic substrate nor was it blocked by metabolic inhibitors or various organic acid competitors. No evidence of proximal tubular secretion was noted in the dog using stop-flow analysis; diatrizoate-inulin U/P ratios were approximately 0.9. Furthermore in p-amino-hippurate (PAH) clearance experiments in the dog, administration of diatrizoate failed to alter PAH clearance. These data indicate active renal transport of diatrizoate in certain species, but not in oth
ISSN:1660-8151
DOI:10.1159/000179916
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
5. |
Etude du potassium total chez des patients en insuffisance rénale chronique |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 173-190
P.A. Delwaide,
G. Rorive,
Preview
|
PDF (1999KB)
|
|
摘要:
La mesure du potassium total par «compteur corporel total» a été appliquée à 50 patients atteints d’insuffísance rénale chronique. 1. Le capital potassique est, dans l’ensemble, significativement diminué et représente 88,6% de la valeur normale. II n’existe aucune corrélation avec la kaliémie ou le degré d’insuffisance rénale. 2. Un certain nombre de patients présentent toutefois un excès de potassium total, accompagné dans ce cas d’hyperkaliémie. 3. L’effet immédiat de la dialyse est une perte de potassium moyenne de 150 mEq; la diminution constatée est en corrélation statistiquement significative avec le capital potassique initial. 4. A long terme (surveillance poursuivie chez 14 patients pendant 18–24 mois), l’effet de la dialyse peut, en dépit de fluctuations notables, se résumer en une augmentation initiale du potassium total suivie d’une diminution progressive, cependan
ISSN:1660-8151
DOI:10.1159/000179917
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
6. |
An Improved Needle Set for Fistula Hemodialysis |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 191-196
B.D. Nidus,
R. Matalon,
P. Deutsch,
R.P. Eisinger,
Preview
|
PDF (564KB)
|
|
摘要:
An improved No. 16 gauge needle set for fistula dialysis is described. This set enhances successful dialysis by facilitating venepuncture, causing less scarring, and offering lower resistance to blood flow than the No. 14 needle sets commonly used. A technique is presented for connecting a patient’s pull and return needle sets so that dialysis may be interrupte
ISSN:1660-8151
DOI:10.1159/000179918
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
7. |
Summaries – Résumés |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 197-199
Preview
|
PDF (343KB)
|
|
ISSN:1660-8151
DOI:10.1159/000179919
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
8. |
Varia |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 200-201
Preview
|
PDF (208KB)
|
|
ISSN:1660-8151
DOI:10.1159/000179920
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
9. |
Book Reviews-Livres nouveaux |
|
Nephron,
Volume 8,
Issue 2,
1971,
Page 202-204
Preview
|
PDF (313KB)
|
|
ISSN:1660-8151
DOI:10.1159/000179921
出版商:S. Karger AG
年代:1971
数据来源: Karger
|
|