|
11. |
Cystic Basal Cell Carcinoma of the Orbit and Eyelids |
|
Ophthalmic Plastic and Reconstructive Surgery,
Volume 14,
Issue 2,
1998,
Page 134-140
Zeynel Karcioglu,
Hailah Al-Hussain,
A. Svedberg,
Preview
|
PDF (579KB)
|
|
摘要:
When basal cell carcinoma develops cystic change, its clinical and radiological features vary, leading to confusion in differential diagnosis. We report four cases with cystic formation of 62 patients with orbital and adnexal basal cell carcinoma encountered during the last 12 years. The salient clinical, radiological, and histopathological features of these cases are presented and differential diagnosis of large cystic lesions in the orbit is discussed. When the basal cell carcinoma develops cystic changes it mimics other orbital cysts, including inclusion cysts due to penetrating injury, mucoceles, and necrotic metastatic tumors.
ISSN:0740-9303
出版商:OVID
年代:1998
数据来源: OVID
|
12. |
Rounding of the Inferior Rectus MuscleA Helpful Radiologic Finding in the Management of Orbital Floor Fractures |
|
Ophthalmic Plastic and Reconstructive Surgery,
Volume 14,
Issue 2,
1998,
Page 141-143
Lawrence Levine,
Bryan Sires,
Lindell Gentry,
Richard Dortzbach,
Preview
|
PDF (214KB)
|
|
摘要:
The authors describe a patient with an orbital floor fracture that did not demonstrate a distinct fracture on computed tomography (CT) imaging. The key radiologic finding was rounding of the inferior rectus muscle.
ISSN:0740-9303
出版商:OVID
年代:1998
数据来源: OVID
|
13. |
Standardized Range of Conformers and Symblepharon Rings |
|
Ophthalmic Plastic and Reconstructive Surgery,
Volume 14,
Issue 2,
1998,
Page 144-145
Bhupendra Patel,
Nigel Sapp,
Richard Collin,
Preview
|
PDF (123KB)
|
|
摘要:
Conformers and symblepharon rings are routinely used to keep fornices formed after socket surgery or in the presence of conjunctival cicatricial disease. However, there is no accepted standard size or shape of conformers or symblepharon rings. We measured the ideal conformer and symblepharon sizes in patients undergoing socket surgery and designed six conformer and symblepharon sizes. The full set of six conformers and symblepharon rings is available to the surgeon at the end of surgery. We have successfully used these conformers and symblepharon rings in over 600 cases during the last 7 years. These standardized sizes allow more accurate fitting of conformers and symblepharon rings.
ISSN:0740-9303
出版商:OVID
年代:1998
数据来源: OVID
|
14. |
Incision Site Tissue Necrosis After Dacryocystorhinostomy |
|
Ophthalmic Plastic and Reconstructive Surgery,
Volume 14,
Issue 2,
1998,
Page 146-149
Hossein Salour,
Nafiseh Montazerin,
Preview
|
PDF (165KB)
|
|
摘要:
Incision site tissue necrosis (ISTN) after surgical procedures of the facial area is rare. In this article, two patients who have suffered from ISTN after dacryocystorhinostomy (DCR) are reported. No known causes have been found for this complication; however, over-cauterization could be considered a contributing factor in at least one of our cases.
ISSN:0740-9303
出版商:OVID
年代:1998
数据来源: OVID
|
15. |
LETTER TO THE EDITOR |
|
Ophthalmic Plastic and Reconstructive Surgery,
Volume 14,
Issue 2,
1998,
Page 150-150
Preview
|
PDF (24KB)
|
|
ISSN:0740-9303
出版商:OVID
年代:1998
数据来源: OVID
|
|