|
1. |
Application of ion beam sputtering for high‐resolution electron microscopy |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 1-19
Koichi Kanaya,
Norio Baba,
Yoshinori Muranaka,
Koichi Adachi,
Preview
|
PDF (3850KB)
|
|
摘要:
AbstractIon beam sputtering for high‐resolution electron microscopy has basically provided miscellaneous operational features such as atomic shadowing, uncoated observation, and etching of biological specimens coupled with tungsten sputter coating and thinning of solid materials.Based on the power‐potential law of Lindhard for ionic impact phenomena on metal surfaces, the universal yield‐energy relationship has been derived. Thereby the sputtering deposition rate with reference to the sputtering removal rate was obtained as a function of sputtering yield, and the most important angular distribution of sputtering yield could be measured by using the hemicylindrical specimen stage.Evidence is presented to show that ion beam sputtering has become one of the most powerful tools for high‐resolution electron mic
ISSN:0741-0581
DOI:10.1002/jemt.1060040102
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
2. |
Characterization of chemically defined neurons and their cellular relationships by combined immunocytochemistry and radioautographic localization of transmitter uptake sites |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 21-39
Olivier Bosler,
Alain Beaudet,
Virginia M. Pickel,
Preview
|
PDF (6912KB)
|
|
摘要:
AbstractRadioautography and immunocytochemistry may be combined at the light and electron microscopic levels for simultaneously localizing uptake sites for exogenous transmitter molecules [such as (3H)monoamines or (3H)amino acids] and endogenous transmitter‐related antigens (classical transmitters and their synthesizing enzymes as well as neuropeptides) in the central nervous system. Silver grain accumulations indicative of transmitter uptake sites are readily distinguishable from immunocytochemical labels of the peroxidase‐antiperoxidase (PAP), avitin‐biotin, or colloidal gold methods. The combination of uptake radioautography and immunocytochemistry may be applied to the investigation of (1) the chemical identity of (3H) transmitter‐accumulating elements, (2) the coexistence of different neurotransmitters within the same neurons, and (3) the cellular basis of interactions between certain neurotransmitters, in particular monoamines, GABA, and neuropeptides. This article describes and evaluates the method and reviews the available experimental data derived from its appl
ISSN:0741-0581
DOI:10.1002/jemt.1060040103
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
3. |
Wheat germ agglutinin fracture‐label of lymphocyte plasma and intracellular membranes |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 41-46
Maria Rosaria Torrisi,
Antonio Pavan,
Lavinia Vittoria Lotti,
Luigi Frati,
Preview
|
PDF (2036KB)
|
|
摘要:
AbstractConventional lectin cytochemistry or immunocytochemistry can be associated with freeze‐fracture in fracture‐label techniques: The thin section fracture‐label and the critical point drying fracture‐label. In the first method, which is particularly useful for investigating intracellular membranes, cells or tissues are freeze‐fractured, thawed, labeled, and embedded in resin. Wheat germ agglutinin labeling on freeze‐fractured human lymphocytes confirms the existence of two compartments of intracellular membranes, based on the sialoglycocompon
ISSN:0741-0581
DOI:10.1002/jemt.1060040104
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
4. |
The use of scanning electron microscope autoradiography to localize the blueberry shoestring virus in its aphid vector |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 47-54
Karen L. Klomparens,
Maureen A. Petersen,
Donald C. Ramsdell,
William G. Chaney,
Preview
|
PDF (2323KB)
|
|
摘要:
AbstractScanning electron microscopy autoradiography (SEM‐AR) in conjunction with light microscope autoradiography (LM‐AR) was used to follow the movement of125I‐labeled blueberry shoestring virus (BBSSV) through its aphid vectorIllinoia pepperiwith varying acquisition access periods (AAP). At 6 hr AAP, the virus had reached the stomach; at 12 hr AAP, it had reached the anterior of the intestines, and after 48 hr, AAP was present throughout the aphid. SEM‐AR using backscatter electron detection proved very useful because the sample bulk resulted in a shortened exposure time compared to LM sections, correlation of the autoradiograms could be made with fine structure, preparing large numbers of samples was easy, and examining whole longitudinal sections of aphids at low magnification with a clearly visible marker was possible. Limitations were mostly attributed to sample preparation and, in some cases, were easily r
ISSN:0741-0581
DOI:10.1002/jemt.1060040105
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
5. |
Digital image processing for nonperiodic objects and an on‐line image processing system for high resolution electron microscopy |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 55-62
Norio Baba,
Eisaku Oho,
Makio Mukai,
Koichi Kanaya,
Preview
|
PDF (2856KB)
|
|
摘要:
AbstractA digital image processing method for noise removal and image enhancement in nonperiodic structural images is described. The method for noise removal uses a reversible transform between an image and image autocorrelation function. The Laplacian filter is then employed for image enhancement. Furthermore, an on‐line image processing system for highresolution TEM is presente
ISSN:0741-0581
DOI:10.1002/jemt.1060040106
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
6. |
A method for scanning electron microscopic observation of glomerular vascular poles in rat kidneys |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 63-64
Daniel Casellas,
Preview
|
PDF (655KB)
|
|
ISSN:0741-0581
DOI:10.1002/jemt.1060040107
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
7. |
Observations on the effects on tissue dimensions of altering osmium tetroxide molarity with sucrose or sodium chloride |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 65-67
J. Louw,
S. A. Wolfe‐Coote,
R. S. Day,
Preview
|
PDF (282KB)
|
|
ISSN:0741-0581
DOI:10.1002/jemt.1060040108
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
8. |
Retrieval of thick sections from glass for high‐voltage electron microscopy |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 69-71
J. N. Turner,
D. L. Decker,
Preview
|
PDF (658KB)
|
|
ISSN:0741-0581
DOI:10.1002/jemt.1060040109
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
9. |
An improved specimen carrier for large‐scale embedment with lowicryl |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 73-74
Kristine H. Templeman,
Charles R. Wira,
Preview
|
PDF (150KB)
|
|
ISSN:0741-0581
DOI:10.1002/jemt.1060040110
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
10. |
Review: Conference on recent advances in electron and light imaging in biology and medicine held at the new york city sheraton centre hotel, march 18–21, 1986. Sponsored by the new york academy of science, and chaired by Dr. Andrew Somlyo, University of Pennsylvania |
|
Journal of Electron Microscopy Technique,
Volume 4,
Issue 1,
1986,
Page 75-75
George Ruben,
Preview
|
PDF (113KB)
|
|
ISSN:0741-0581
DOI:10.1002/jemt.1060040111
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
|