|
1. |
Plasmapheresis in the treatment of acute relapsing inflammatory demyelinating polyradiculoneuropathy associated with human immunodeficiency virus infection: A case report |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 149-151
David Wuest,
Dennis Goldflnger,
Preview
|
PDF (300KB)
|
|
摘要:
AbstractNeurologic complications, including both the acute and chronic forms of inflammatory demyelinating polyradku‐loneuropathy (IDP) are becoming more prevalent among patients with the acquired immunodeficiency syndrome (AIDS) and AIDS‐related‐complex (ARC). Although the etiology of the above radicuioneuropathies is not known, an autoimmune process has been postulated. Plasmapheresis has been reported to be of benefit in both the acute and chronic forms of these neuropathies. In this report we describe the use of plasmapberesis in the treatnient of a patient with ARC and the acute relapsing form of IDP. The treatment consisted of an intensive canne of plasmapheresis following his initial presentation and after an acute relapse which occurred several weeks after his initial presentation. Both the initial presentation and relapse involved respiratory compromise necessitatig intubation and mechanical ventilation. In both instances marked clinical improvement was achieved after initiation of plasmapheresis. Thus, plasmapheresis may have a rote in the management of acute relxpsing IDP associated with human immunodeficiency virus infe
ISSN:0733-2459
DOI:10.1002/jca.2920040402
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
2. |
Plateletpheresis concentrates produced in 30 minutes along with plasma and packed red cells: Preliminary results |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 152-154
Mauro Valbonesi,
Roberto Frisoni,
Carlo Capra,
Giuseppe Lercari,
Mauro Fella,
Pierantonio Pittaluga,
Preview
|
PDF (283KB)
|
|
摘要:
AbstractCentrifugal devices for donor plasmapheresis that collect platelets as a by‐product have recently been introduced. The platelet yield ranges from 1.2 to 2 × 1011per collection, and the collection time exceeds 50 minutes. An attempt to increase yields and to reduce the procedure time was carried out at our center, taking advantage of the Dideco Eccentriplate (Dideco spa. Mirandola, Italy). Within 30 minutes, 510 ml of plasma were collected along with 3.3 × 1011platelets. The shift of donors from whole blood to plasma and platelet donation generated a progressive decrease in red‐cell availability. In order to maintain plasma and platelet production without affecting the erythrocyte production, a technique was developed that allows the collection of 3.68 × 1011platelets, 250 ml of plasma, and 225 ml of packed red blood cells with a hematocrit of 66.5%. The mean procedure time was 31.6 minutes; 2,671 ml of blood were processed at flow rates of 85–100 ml/minute. The cellular cross contamination of the platelet concentrates was 1.76 × 108(leukocytes) and 2.23 × 108(erythrocytes). Although me procedure was carried out in a selected group of donors, the technical experience has strongly modified our procedure for platelet and plasma
ISSN:0733-2459
DOI:10.1002/jca.2920040403
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
3. |
Staphyiococcal carriage and infection in myasthenia gravis patients receiving therapeutic apheresis |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 155-157
Richard B. Johnson,
Robert R. Muder,
Spyros O. Kominos,
Thomas J. Nasca,
Preview
|
PDF (313KB)
|
|
摘要:
AbstractPopulations exposed to repetitive needle puncture (such as hemodialysis patients, insulin‐dependent diabetics, and parenteral drug abusers) are at increased risk for nasal carriage ofStophylococcus aurais. These groups appear to have increased susceptibility to serious staphylococcal infection as well. We performed a microbiologie survey on a group of patients receiving regular, long‐term therapeutic apheresis for my asthenia gravis (MG), and compared the rate of nasal staphylococcal carriage with that found in control groups of MG patients not receiving apheresis and ambulatory general medical patients without known risk factors for staphylococcal carriage. Medical records were reviewed for episodes of significant staphyiococcal infection occurring since commencement of apheresis. NasalS. auraiscarriage was found in 9/29 (31%) apheresis patients, 8/30 (27%) MG controls, and 8/30 (27%) general medical controls. No significant difference in frequency of apheresis was noted between carriers and noncarriers. A single episode ofS. aureusbacteremia occurred in 95 patient‐years of apheresis therapy. We conclude that therapeutic apberesis for MG does not increase the risk of staphylococcal carriage, and mat serious infection is infre
ISSN:0733-2459
DOI:10.1002/jca.2920040404
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
4. |
Uncontrolled trial of cryofiltration in rheumatoid arthritis |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 158-165
Paul S. Matehesky,
James W. Smith,
Anna Koo,
John Clough,
Christine Skibinski,
Gerald J. Beck,
Yukihiko Nose,
Preview
|
PDF (674KB)
|
|
摘要:
AbstractIn an open trial of cryofiltration in rheumatoid arthritis at our institution, 19 patients received 464 treatments; the intensive schedule of ten treatments in 5 weeks was completed in 14 of the 19, and excellent to good clinical response was achieved in ten of these. The combined results demonstrated significant reductions in Ritchie index, morning stiffness, and 50‐foot walk time in the intensive treatment period, as well as significant increases in hand grip strengths. In the maintenance treatment period treatment frequency was individually selected and at less frequent intervals. Changes in clinical parameters were notably less. Although significant correlations were observed between the percent change in clinical parameters and the percent change in biochemical and hematolog‐ical parameters, no consistent pattern was found. The favorable results of this trial and other uncontrolled trials has led to a two‐center double‐blind controlled trial of cryofiltration in rheumatoid arthritis that is now in p
ISSN:0733-2459
DOI:10.1002/jca.2920040405
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
5. |
New application of the autotrans: Autologous support of the organ donor and salvage of the donor's red blood cells for the transfusion support of organ recipients |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 166-168
Mauro Valbonesi,
Mauro Ferrari,
Susanna Zia,
Carlo Piri,
Mauro Fella,
Pierantonlo Pittaluga,
Carla Zat,
Alessandro Concaro,
Iris Fontana,
Francesco Destefano,
Gian Franco Ciappina,
Marcello Canale,
Preview
|
PDF (286KB)
|
|
摘要:
AbstractOrgan donation is usually limited to solid tissues; paradoxically, organ donors undergoing expiant are often transfused in preparation for or during surgery. This practice increases the requirement for blood and adds immunological and infectious risks for both recipients and donors of grafts. We have investigated the possibility of supporting an expiant with intraoperative blood salvage and, in the case of a cadaver donor, at the end of the operation, salvaging blood for potential use in the graft recipient. This preliminary report describes the technique and the results obtained in two procedures. The volume of red cells with a hematocrit of 55% obtained from the two donors was 2,090 and 1.180 ml, respectively. These components were employed for the transfusion support of the organ recipients.
ISSN:0733-2459
DOI:10.1002/jca.2920040406
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
6. |
Preface |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 170-170
Joanna M. Heal,
Preview
|
PDF (108KB)
|
|
ISSN:0733-2459
DOI:10.1002/jca.2920040407
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
7. |
The IBM blood cell separator and blood cell processor: A personal perspective |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 171-182
Alan L. Jones,
Preview
|
PDF (2860KB)
|
|
ISSN:0733-2459
DOI:10.1002/jca.2920040408
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
8. |
Kinetics modeling of plasma exchange: Intra‐ and post‐plasma exchange |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 183-187
Robert M. Kellogg,
Jeane P. Hester,
Preview
|
PDF (340KB)
|
|
ISSN:0733-2459
DOI:10.1002/jca.2920040409
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
9. |
Modeling of platelet concentrate yield in continuous‐flow cell separation devices |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 188-193
Jeane P. Hester,
Gerard J. Ventura,
Preview
|
PDF (469KB)
|
|
ISSN:0733-2459
DOI:10.1002/jca.2920040410
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
10. |
A new approach to neocyte transfusion: Preliminary report |
|
Journal of Clinical Apheresis,
Volume 4,
Issue 4,
1988,
Page 194-197
Sherwin V. Kevy,
May S. Jacobson,
Martin Fosburg,
Melanie Renaud,
Anne Scanlon,
Raleigh Carmen,
Edward Nelson,
Preview
|
PDF (291KB)
|
|
摘要:
AbstractA method has been developed using phthalate oils to quality control units of young red cells (neocytes). Neocytes prepared by the NEOCEL system have a mean young red cell enrichment of 90% with only 3.4% less than 80%. Neocytes prepared in a Wood cell processor have an average enrichment of 81 % with 27% less than 75%. Based on a 12 month period, the patients as a group have received an average of 14% fewer transfusions and an 18% decrease in red cells per kg/yr as compared to frozen red cells.
ISSN:0733-2459
DOI:10.1002/jca.2920040411
出版商:John Wiley&Sons, Inc.
年代:1988
数据来源: WILEY
|
|