1. |
The Sub- and Super-Equivalence Method of Isotope Dilution Analysis |
|
Isotopenpraxis Isotopes in Environmental and Health Studies,
Volume 14,
Issue 2,
1978,
Page 49-56
J. Klas,
J. Tölgyessy,
J. Lesny,
E. H. Klehr,
Preview
|
PDF (577KB)
|
|
摘要:
The basic concept, application-possibilities and examples of using of the sub- and super-equivalence method of isotope dilution analysis are described.
ISSN:0021-1915
DOI:10.1080/10256017808544144
出版商:Taylor & Francis Group
年代:1978
数据来源: Taylor
|
2. |
Originalarbeiten: Human Serum Albumin Microspheres for Lung Imaging – Preparation and Evaluation |
|
Isotopenpraxis Isotopes in Environmental and Health Studies,
Volume 14,
Issue 2,
1978,
Page 57-61
Aleyamma Raju,
R. Mani,
K. D. Divekar,
D. V. S. Narasimhan,
A. D. Rahalkar,
R. Lal,
Sundararajan,
P. Kotrappa,
R. S. Mani,
Preview
|
PDF (565KB)
|
|
摘要:
Preparation of human serum albumin microspheres of well defined particle size distribution using a spinning disc aerosol generator has been investigated by the authors. A set up is described for bulk preparation of microspheres suitable for lung imaging. A simple procedure for denaturation of the microspheres by direct oven heating has been standardised. Methods for Tc99mlabelling of these microspheres with high radiochemical yield and purity have been studied. Uptake and clearance of the labelled microspheres have been followed in experimental animals. Histopathological examination has been carried out to confirm biodegradability and safety of the microspheres. The microspheres have shown excellent lung uptake and have been found to be very safe for administration.
ISSN:0021-1915
DOI:10.1080/10256017808544145
出版商:Taylor & Francis Group
年代:1978
数据来源: Taylor
|
3. |
Bestimmung der radiochemischen Reinheit von Pertechnetatlösungen aus99mTc-Generatoren |
|
Isotopenpraxis Isotopes in Environmental and Health Studies,
Volume 14,
Issue 2,
1978,
Page 62-65
B. Johannsen,
B. Noll,
Preview
|
PDF (344KB)
|
|
摘要:
Es wurden papier- und dünnschichtchromatographische Methoden zur Bestimmung der radiochemischen Reinheit von99mTC-Generatoreluat unter Benutzung von reduziertem hydrolysiertem Tc und verschiedenen Tc-Komplexen als Modellverunreinigungen methodenkritisch untersucht. Den Ergebnissen zufolge und wegen praktischer Vorzüge wird die Dünnschichtchromatographie auf Kieselgel mit Methylāthylketon als besonders geeignet angesehen.
ISSN:0021-1915
DOI:10.1080/10256017808544146
出版商:Taylor & Francis Group
年代:1978
数据来源: Taylor
|
4. |
Tritium-Protonen-Austausch an frischem und oxydiertem Lecithin |
|
Isotopenpraxis Isotopes in Environmental and Health Studies,
Volume 14,
Issue 2,
1978,
Page 65-67
J. Schreiber,
Preview
|
PDF (245KB)
|
|
摘要:
Es wird eine Methode zur Austauschmarkierung acider Protonen in Lecithin und zu ihrer quantitativen Bestimmung beschrieben. Die Aussagefähigkeit dieser Methode wird an den Beispielen Lecithin-Monohydrat und Autoxydationsprodukte diskutiert.
ISSN:0021-1915
DOI:10.1080/10256017808544147
出版商:Taylor & Francis Group
年代:1978
数据来源: Taylor
|
5. |
Chemistry and Toxicology of Pesticide Chemicals VII: Photodecomposition of Leptophos |
|
Isotopenpraxis Isotopes in Environmental and Health Studies,
Volume 14,
Issue 2,
1978,
Page 68-70
S. M. A. D. Zayed,
M. Farghaly,
A. Hassan,
Preview
|
PDF (295KB)
|
|
摘要:
The exposure of32P-Leptophos on thin layers of silica gel to UV- and sunlight led to the degradation of the insecticide. The oxon, desmethylleptophos, desbromoleptophos, O-methyl phenylthiophosphonic acid and phenylphosphonic acid were identified.
ISSN:0021-1915
DOI:10.1080/10256017808544148
出版商:Taylor & Francis Group
年代:1978
数据来源: Taylor
|
6. |
Radiometrische Flächenmassemeßgeräte mit adaptivem Zeitverhalten |
|
Isotopenpraxis Isotopes in Environmental and Health Studies,
Volume 14,
Issue 2,
1978,
Page 71-73
C. Löber,
Preview
|
PDF (248KB)
|
|
摘要:
Die Anwendung adaptiver Meβprinzipien gewinnt in der Prozeβmeβtechnik zunehmend an Bedeulung. Im folgenden wird ein Prinzip zur Glättung der Schwankungen des stochastischen Meβsignals radiometrischer Flächenmassemeβgeräle (FMM-Geräte) mit Hife adaptiver Filter beschrieben, wodurch die Einstellzeit ohne störende Vergröβerung des statistischen Meβfehlers um mindestens eine Gröβenordnung verringert werden kann.
ISSN:0021-1915
DOI:10.1080/10256017808544149
出版商:Taylor & Francis Group
年代:1978
数据来源: Taylor
|
7. |
Messung der Kernstrahlung von59Fe unter besonderer Berücksichtigung der Flüssig-Szintillations-Messung |
|
Isotopenpraxis Isotopes in Environmental and Health Studies,
Volume 14,
Issue 2,
1978,
Page 74-77
L. Finsterbusch,
K.-D. Floβmann,
Preview
|
PDF (346KB)
|
|
摘要:
Die Messung von53Fe im Flüssigszintillationszāhler bringt gegenüber der Messung mit konventionellen Meβplätzen eine wesentliche Steigerung an Empfindlichkeit und Genauigkeit. Diese Tatsache ist bei Tracerversuchen besonders wichtig. Die automatische Quenchkorrektur wird jedoch bei waβrigen Proben infolge zeitlicher Instabilität der eisenhaltigen Lösungen gestört. Es wird ein spezieller LSC-Cocktail angegeben, der diese Probleme beseitigt. Um Inhomogenitäten in der Probenzusammenselzung zu erkennen, wird zur Beurteilung des Meβwertes die Doppelverhältnismethode herangezogen.
ISSN:0021-1915
DOI:10.1080/10256017808544150
出版商:Taylor & Francis Group
年代:1978
数据来源: Taylor
|
8. |
Buchbesprechungen |
|
Isotopenpraxis Isotopes in Environmental and Health Studies,
Volume 14,
Issue 2,
1978,
Page 78-80
Preview
|
PDF (300KB)
|
|
ISSN:0021-1915
DOI:10.1080/10256017808544151
出版商:Taylor & Francis Group
年代:1978
数据来源: Taylor
|