|
1. |
Determination of volatile carboxylic acids in animal wastes by (GC)2of their benzyl esters |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 49-53
X. Monseur,
J. Walravens,
P. Dourte,
M. Termonia,
Preview
|
PDF (338KB)
|
|
摘要:
AbstractThe C1‐C6fatty acids present in various types of heterogeneous animal wastes were isolated by steam distillation and determined as benzyl esters by high resolution gas chromatography. Glass capillary columns, deactivated with barium carbonate and coated with UCON HB 5100, allowed the analysis of benzyl formate, acetate, propionate, isobutyrate, butyrate, isovalerate, valerate, and caproate in less than 20 minutes. Recovery tests, performed on more than 50 different samples, indicated a benzylation yield and an overall efficiency higher than 99%, with a standard deviation of 2.6% (C5) to 6.0% (C1). The absolute detection limit ranged from 0.3 picomole (caproic acid) to 1.0 picomole (formic acid
ISSN:0935-6304
DOI:10.1002/jhrc.1240040202
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
2. |
Determination of the cephalosporin Ro 13‐99041in plasma, urine, and bile by means of ion‐pair reversed phase chromatography |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 54-59
K. H. Trautmann,
P. Haefelfinger,
Preview
|
PDF (484KB)
|
|
摘要:
AbstractAn HPLC method has been developed for the determination of the cephalosporin antibiotic Ro 13‐9904 in plasma, urine, and bile of dogs and of human volunteers using the technique of ion‐pair chromatography with a LiChrosorb RP‐18 column. The three mobile phases employed contained tetrapentyl‐, tetraoctyl‐ and hexadecyltrimethyl‐ammonium bromide, respectively, as lipophilic counterions. The chromatographic conditions chosen allowed simple and rapid sample preparation. Plasma was deproteinized with ethanol and the supernatant was directly injected onto the column; urine and bile were diluted with mobile phase and injected without any purification. The detection limit for the cephalosporin was about 0.5 μg/ml for plasma samples and approximately 5 μg/ml for b
ISSN:0935-6304
DOI:10.1002/jhrc.1240040203
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
3. |
An integrated GC/FT‐IR system for the analysis of environmental pollutants |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 60-69
L. V. Azarraga,
C. A. Potter,
Preview
|
PDF (665KB)
|
|
摘要:
AbstractAn integrated gas chromatography/Fourier transform infrared spectrometry (GC/FT‐IR) system developed for the analysis of environmental pollutants is described. The versatility of the system allows the utilization of many different techniques of sample introduction and manipulation during analysis. The sample can be introduced by direct injection or thermal desorption from an adsorbent cartridge, and can then be separated on one of two capillary columns and detected by FT‐IR or an FID. Cold traps and collection cartridges incorporated in the system permit recovery and additional fractionation of samples. Recovered sample and sample fractions can then be re‐analyzed by GC/FT‐IR or subsequently analyzed by GC/MS or other
ISSN:0935-6304
DOI:10.1002/jhrc.1240040204
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
4. |
Resolution of equine estrogens using glass capillary columns |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 70-73
G. K. Pillai,
K. M. McErlane,
Preview
|
PDF (320KB)
|
|
摘要:
AbstractA rapid and specific procedure is described for the resolution of nine steroids present in conjugated estrogen preparations. Resolution is achieved on a short glass capillary column coated with Silar 10C after dual derivatization to oxime‐trimethylsilyl ether
ISSN:0935-6304
DOI:10.1002/jhrc.1240040205
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
5. |
Correlation between excess adsorption data measured for solvent mixture/adsorbent systems and RMvalues obtained for different solutes chromatographed in binary mobile phases |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 74-78
B. Ościk‐Mendyk,
J. K. Róz̈ło,
M. Jaroniec,
Preview
|
PDF (362KB)
|
|
摘要:
AbstractThis paper concerns the application of excess adsorption isotherms, measured for solvent mixture/adsorbent systems, to the characterization of TLC data. For this purpose the excess adsorption isotherms for three liquid mixtures: cyclohexane/ benzene, benzene/acetone, and carbon tetrachloride/ethyl acetate on silica gel at 20°C have been measured. These mixtures have been used as binary mobile phases in TLC measurements. It has been shown for a given solute in binary mobile phase that the quantity RMis a simple function of the excess adsorption. Parameters of this function have been used to characterize chromatographic systems with binary mobile phases
ISSN:0935-6304
DOI:10.1002/jhrc.1240040206
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
6. |
Some comments on the barium carbonate (Grob) procedure for treating glass capillary columns for gas‐liquid chromatography |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 79-80
Victor Pretorius,
J. W. Du Toit,
J. C. Davidtz,
Preview
|
PDF (393KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040207
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
7. |
HPLC with chemically bonded stationary phases. 4. Amide, carbamate and chiral α‐aminoamide phases |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 81-83
S. A. Matlin,
A. Tito‐Lloret,
W. J. Lough,
D. G. Bryan,
T. Browne,
S. Mehani,
Preview
|
PDF (268KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040208
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
8. |
On‐column detection using a fused silica column |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 83-85
Frank J. Yang,
Preview
|
PDF (215KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040209
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
9. |
Application of multidimensional switching to the analysis of volatiles |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 86-89
J. Sevcik,
Preview
|
PDF (205KB)
|
|
摘要:
AbstractA multidimensional switching system with two packed columns has been used for the analysis of volatiles. Use of a high‐boiling solvent and the backflush mode permitted total resolution of the mixture discussed in a short analysis tim
ISSN:0935-6304
DOI:10.1002/jhrc.1240040210
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
10. |
Determination of solute‐solvent association effects in liquid‐solid chromatography with mixed mobile phases |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 2,
1981,
Page 89-90
M. Jaroniec,
J. A. Jaroniec,
W. Gołkiewicz,
Preview
|
PDF (139KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040211
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
|