1. |
Polygon diagrams of chromatographic data |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 99-101
Guido Janssens,
Preview
|
PDF (336KB)
|
|
摘要:
AbstractUse of a Hewlett‐Packard 2648 A graphics terminal connected to a HP 3354 B Laboratory Automation System for drawing polygon diagrams of chromatographic data has been investigated. The computer program is designed to reduce polygon overlapping and hiding by fully automatic parameter adjustmen
ISSN:0935-6304
DOI:10.1002/jhrc.1240040302
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
2. |
A study of the effects of temperature and pressure on the retention time in series‐coupled columns under conditions of constant mass flow rate |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 102-108
T. S. Buys,
T. W. Smuts,
Preview
|
PDF (351KB)
|
|
摘要:
AbstractThe technique of controlling chromatographic selectivity by the adjustment of column temperatures in systems of series‐coupled columns is investigated by means of a general model incorporating the effects of temperature and mobile phase compressibility. In a previous article the performance of series‐coupled columns was investigated under conditions of constant overall pressure drop. The present paper, on the other hand, considers systems in which a constant mass flow rate is maintained at all temperatures. The expressions derived for the effective partition coefficient and the retention time are compared with those of the previous paper. The numerical results for two‐column systems exhibit the same major trends as those for constant pressure drop. It is shown that the effective partition coefficient is slightly dependent on the mass flow
ISSN:0935-6304
DOI:10.1002/jhrc.1240040303
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
3. |
Gas chromatographic separation of triglycerides according to their degree of unsaturation on glass capillary columns |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 109-114
Helmut Traitler,
And RÉ Prévǒt,
Preview
|
PDF (402KB)
|
|
摘要:
AbstractTriglycerides are separated according to their molecular weight and their degree of unsaturation on glass capillary columns by use of the on‐column injection technique. The columns employed are silylated SE‐30 columns of 4.5, 8, and 10m length with a film thickness of ca. 0.15 μm. The paper gives several examples of chromatograms of natural and hydrogenated triglycerides as well as of mixtures of pure, known triglycerides before and after interesterifica
ISSN:0935-6304
DOI:10.1002/jhrc.1240040304
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
4. |
Continuous and gradient TLC development of 4‐dimethylaminoazobenzene‐4′‐sulfonyl amino acid derivatives |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 115-120
Władysław Gołkiewicz,
Tadeusz Wolski,
Preview
|
PDF (402KB)
|
|
摘要:
AbstractThin‐layer gradient elution chromatography is a convenient technique for separation of very complicated mixtures; in some cases the gradient technique can be replaced by continuous development. The two techniques are compared in practice by using them to separate a mixture of dabsyl derivatives of amino acid
ISSN:0935-6304
DOI:10.1002/jhrc.1240040305
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
5. |
Deactivation of fused silica capillary columns with pyrocarbon |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 122-123
Victor Pretorius,
D. H. Desty,
Preview
|
PDF (130KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040306
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
6. |
Rapid separation of isomeric Xylenes on a short liquid crystal‐coated glass capillary in the supercooled temperature range |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 123-124
G. Kraus,
M. Schierhorn,
Preview
|
PDF (123KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040307
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
7. |
A solid injection system for fused silica capillary columns in a GC/MS system |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 125-127
A. P. J. M. De Jong,
Preview
|
PDF (206KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040308
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
8. |
Effect of adsorption on resolution in capillary gas chromatography |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 127-129
L. Soják,
V. G. Berezkin,
Preview
|
PDF (220KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040309
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
9. |
Rapid combined liquid chromatography/mass spectrometry method for quantitative analysis of atrazine |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 130-131
J. E. Williamson,
N. Evans,
Preview
|
PDF (191KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040310
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
10. |
Ion‐pair HPLC of chlorhexidine–A simple, rapid method for quantitation in pharmaceutical preparations |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 3,
1981,
Page 132-134
J. Bachner,
G. Heinisch,
H. Matous,
Preview
|
PDF (164KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040311
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|