|
1. |
Determination of chelating agents in Hanford tank waste simulant by capillary zone electrophoresis |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 183-188
Nathan E. Ballou,
Gerald R. Ducatte,
Changyue Quang,
Vincent T. Remcho,
Preview
|
PDF (579KB)
|
|
摘要:
AbstractA capillary electrophoretic method has been developed which achieves rapid quantitative separation and determination of ethylenediaminetetraacetic acid,N‐(2‐hydroxyethyl)ethylenediaminetriacetic acid, diethylenetriaminepentaacetic acid, ethylenediaminediacetic acid, and nitrilotriacetic acid in Hanford tank waste simulant (TWS). Direct UV detection of Cu2+/chelator complexes is used to achieve enhanced sensitivity. The qualitative and quantitative reliability of the method and the quality of separations, as given by efficiency and resolution, is presented. In addition, the limits of detection and linearity of detector response with concentration are given for each chelator. The selection of Cu as the UV‐absorbing species over other transition metals present in the waste is disc
ISSN:0935-6304
DOI:10.1002/jhrc.1240190402
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
2. |
Micellar and microemulsion electrokinetic chromatography of hop bitter acids |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 189-192
Roman Szücs,
Erik Van Hove,
Pat Sandra,
Preview
|
PDF (287KB)
|
|
摘要:
AbstractThe elution order of the hop α‐ and β‐acids has been studied under different modes of electrokinetic separation. A model is advanced to explain the shorter migration times of the more hydrophobic β‐acids compared to the α‐acids in micellar electrokinetic chromatography (MEKC). For quality control of the bitter principles in hops, the ruggedness of electrokinetic separation could be improved by replacing MEKC by microemulsion electrokinetic chromatogra
ISSN:0935-6304
DOI:10.1002/jhrc.1240190403
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
3. |
Characterization of polymers by multi‐step thermal desorption/programmed pyrolysis gas chromatography using a high temperature PTV injector |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 193-199
Mark H. P. M. van Lieshout,
Hans‐Gerd Janssen,
Carel A. Cramers,
Martin J. J. Hetem,
Huub J. P. Schalk,
Preview
|
PDF (642KB)
|
|
摘要:
AbstractThermal treatment hyphenated with gas chromatography is a versatile and powerful tool in the study of polymer characterization. An inexpensive system where thermal treatment at different temperatures occurs inside a Programmable Temperature Vaporization injector (PTV) is described. The samples investigated, commercial plastics, are complex mixtures that contain several polymers and additives. These plastics as well as their pure constituents are subjected to multi‐step thermal treatment. The individual chromatograms of the various constituents of the polymeric sample are correlated with those of the final material in order to identify additives (thermal desorption) and degradation products (pyrolysis). Results obtained with the new method indicate the interesting potentials of the technique for the characterization of polymer compositions. Reproducibility of absolute and relative peak areas has been considered and found to be acceptable. The absence of a heated transfer line and switching valves, which are always present in conventional set‐ups, eliminates the risk of losses of high molecular weight components. Further advantages of the technique proposed are simplicity, versatility, and its inexpensive nat
ISSN:0935-6304
DOI:10.1002/jhrc.1240190404
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
4. |
Analysis of Carbaryl and carbofuran in tobacco samples by HRGC, HPLC, and CZE |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 200-206
Fernando M. Lanças,
Sandra R. Rissato,
Mário S. Galhiane,
Preview
|
PDF (565KB)
|
|
摘要:
AbstractDetermination of carbamate residues in tobacco samples was carried out by three different methods, two having been described in the literature and one developed for the purpose of this work. The extracts were analyzed by HRGC‐FID (using derivatization), by HPLC‐RP with photodiode array detection and by Capillary Zone Electrophoresis (CZE) with UV detection. The extraction method developed used in conjunction with capillary zone electrophoresis showed to be the most suitable for carbamate residue analysis in real tobacco samples. The developed method presented better recovery results in relation to the others. CZE allowed the determination of carbamate residue in real tobacco sample while HPLC and HRGC could not do this, due to co‐elution pro
ISSN:0935-6304
DOI:10.1002/jhrc.1240190405
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
5. |
Gas‐chromatographic headspace analysis of phenol and cresols in soils by direct acetylation |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 207-212
Maria P. Llompart‐Vizoso,
Rosa A. Lorenzo‐Ferreira,
Rafael Cela‐Torrijos,
Preview
|
PDF (546KB)
|
|
摘要:
AbstractA quick, simple and selective procedure has been developed for the determination of phenol,o‐cresol,m‐cresol, andp‐cresol in soil samples. The method is based on the gas chromatographic headspace analysis of phenols as acetate derivatives. These acetates were prepared directly in the wetted soil samples by acetic anhydride in the presence of KHCO3˙With this procedure sample handling is reduced to a minimum as desorption and derivatization of the analytes are developed from the wetted samples inside the vial of the head space sampler.The acetate esters were analyzed using a 60 m × 0.56 mm DIIDP capillary column (di‐isodecyl‐phthalate), using 2‐chlorophenol as an internal standard. The detection limit was between 0.03–0.08 μg g−1for the different species considered. Soil samples having carbon contents lower than 5 % can be analyzed by the
ISSN:0935-6304
DOI:10.1002/jhrc.1240190406
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
6. |
Open‐tubular supercritical fluid chromatography with simultaneous flame ionization and chemiluminescent nitrogen detection |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 213-216
Heng Shi,
Larry T. Taylor,
Eugene M. Fujinari,
Preview
|
PDF (321KB)
|
|
摘要:
AbstractThe use of a simultaneous detection system for open‐tubular supercritical fluid chromatogrphic separation of aniline isomers, alkyl(C8to C18)dimethylamines, a dialkylmethylamine mixture, and an extract of a Japanese horseradish power “Wasabi” is demonstrated. A chemiluminescent nitrogen detector (CLND) and a flame ionization detector (FID) were configured at the end of the open tubular columnviaa zero‐ to dead‐volume tee. The dual detection was achieved with a post‐column split at a 1:2.5 ratio for the CLND and FID, respectively. The optimized CLND showed virtually no response to non‐nitrogenous components such as benzene, toluene, and methanol which were used as injection solvents in these
ISSN:0935-6304
DOI:10.1002/jhrc.1240190407
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
7. |
High speed analysis of H2S and COS impurities in coal gas by capillary gas chromatography |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 217-223
J. B. Laurens,
E. R. Rohwer,
Preview
|
PDF (653KB)
|
|
摘要:
AbstractThere is a need for rapid, on‐line, gas chromatographic analysis of trace levels of hydrogen sulfide and carbon oxysulfide in the oil‐from‐coal industry. In order to improve an existing method based on a polymer bed concentrator, a porous layer open tubular column, and a flame photometric detector, time‐optimization of the various steps involved was attempted. Use of a redesigned concentrator, changed column operating conditions, and a photoionization detector reduced analysis times from 6.5 to 3 min and cycle times from 8 to 3 min. This could be achieved without compromising the 10 ppb detection limit r
ISSN:0935-6304
DOI:10.1002/jhrc.1240190408
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
8. |
Ion chromatography. By Joachim Weiss, VCH, Weinheim, Germany, 1995, Second Edition, ISBN 3‐527‐28698‐5 |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 224-224
Andreas Zemann,
Preview
|
PDF (174KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240190411
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
9. |
Ergot alkaloids as novel chiral selectors in capillary electrophoresis |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 225-226
Benno A. Ingelse,
Jetse C. Reijenga,
Henk A. Claessens,
Frans Everaerts,
Mirko Flieger,
Preview
|
PDF (231KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240190412
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
10. |
Study on the separation of D, L‐ andmeso‐N,N′‐di(carbobenzyloxy)‐2,6‐diaminopimelic acid by SFC |
|
Journal of High Resolution Chromatography,
Volume 19,
Issue 4,
1996,
Page 227-228
Andrei Medvedovici,
Pat Sandra,
Agata Kot,
Alexander Kolodziejczyk,
Preview
|
PDF (168KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240190413
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1996
数据来源: WILEY
|
|