|
1. |
Editorial |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 636-636
Franz P. Schmitz,
Preview
|
PDF (235KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240101202
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
2. |
Editorial |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 637-640
Leslie S. Ettre,
Preview
|
PDF (829KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240101203
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
3. |
Identification of mononitropyrenes and mononitrofluoranthenes in air particulate matter via fused silica gas, chromatography combined with negative ion atmospheric pressure ionization mass spectrometry |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 641-646
W. A. Korfmacher,
L. G. Rushing,
J. Arey,
B. Zielinska,
J. N. Pitts,
Preview
|
PDF (496KB)
|
|
摘要:
AbstractThis paper describes the use of high resolution capillary gas chromatography combined with negative ion atmospheric pressure ionization mass spectrometry (NIAPIMS) for the analysis of an air particulate extract for mononitropyrenes and mononitrofluoranthenes, some of which are powerful bacterial mutagens. The results are compared to those obtained by the electron impact mass spectrometric analysis of the same sample In addition, the NIAPIMS method confirmed the identification of 4‐nitropyrene in the ambient air sampl
ISSN:0935-6304
DOI:10.1002/jhrc.1240101204
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
4. |
An optimized gas chromatographic determination of priority pollutant phenols |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 647-649
O. H. Masi,
W. M. Gulick,
Preview
|
PDF (210KB)
|
|
摘要:
AbstractPriority pollutant phenols are determined by gas chromatography on an SE‐30 WCOT column using hydrogen carrier and flame ionization detection with dual internal standards. Linear responses over ranges ca. 12–125 ng per component are achieved and detection limits at or below 1 ng are obtained. Carrier flow and temperature program are optimized to maintain baseline resolution while affording an analysis time of less than 15 minu
ISSN:0935-6304
DOI:10.1002/jhrc.1240101205
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
5. |
Comparison of eluents in supercritical fluid chromatography as based on density and free volume |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 650-653
F. P. Schmitz,
Preview
|
PDF (250KB)
|
|
摘要:
AbstractA comparative study of chromatographic properties of different supercritical eluents has been performed by considering the retention at equal density or at equal free volume for different mobile phases. At equal density, the temperature dependence of the capacity ratios of aromatic hydrocarbons is the same for different alkane mobile phases, whereas significant deviations are observed when carbon dioxide is employed as the mobile phase. At equal free volume, a comparison of the capacity ratios measured in carbon dioxide and in alkane eluents showed a pronounced similarity for the different mobile phases when the free volume was low, i.e., at high densities. With increasing free volume, the chemical differences of the alkanes on the one hand and carbon dioxide on the other become more apparent in their elution behavior. Furthermore, it is demonstrated that the free volume can also be used as a reference basis for the data of solvatochromic shift experiments.
ISSN:0935-6304
DOI:10.1002/jhrc.1240101206
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
6. |
Analysis of calcium blocker drugs in plasma, HRGC and HPLC analytical conditions for pharmacokinetic studies |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 654-658
C. Giachetti,
P. Poletti,
G. Zanolo,
Preview
|
PDF (325KB)
|
|
摘要:
AbstractCalcium blocker drugs are of increasing therapeutic relevance. Verapamil, nifedipine, diltiazem, and flunarizine are the most widely applied drugs of this type. New dihydropyridines (felodipine, nitrendipine) and related agents are presently undergoing intense investigation. HRGC and HPLC were used to determine eight of these drugs in spiked plasma samples. Both methods allow separation of most of the compounds in a single run and are specific, sensitive, and reproducible both for therapeutic monitoring and for pharmacokinetic studies in man and animals.
ISSN:0935-6304
DOI:10.1002/jhrc.1240101207
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
7. |
High performance liquid chromatographic determination of metoclopramide in plasma and urine and its application to biopharmaceutical investigations |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 659-664
M. Nieder,
H. Jaeger,
Preview
|
PDF (487KB)
|
|
摘要:
AbstractAn optimized HPLC method for the quantification of metoclopramide (MCP) in human plasma and urine is described. MCP and internal standard are extracted from alkalinized substrate into diethyl ether and back‐extracted into dilute acid. The analytes are separated with a ternary mobile phase at cyanopropyl‐silica and detected at 312 nm (UV detection). The lower limit of quantification is 0.5 ng/ml in plasma and 50 ng/ml in urine. Optimization of extraction, chromatography, and detection is discussed. The method is selective to numerous common drug substances with excellent accuracy and precision data. After validation, the method is applied to the samples of a pharmacokinetic study. Pharmacokinetic parameters indicate the need for a sophisticated method as tool for optimization of metoclopramide formulati
ISSN:0935-6304
DOI:10.1002/jhrc.1240101208
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
8. |
Chiral SFC‐separations using polymer‐coated open tubular fused silica columns. Comparison of enantiomeric selectivity in SFC and LC using the same stationary phase of the Pirkle type |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 665-667
W. Röder,
F.‐J. Ruffing,
G. Schomburg,
W. H. Pirkle,
Preview
|
PDF (234KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240101209
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
9. |
Pump filling techniques in SFC: Do they affect precision? |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 668-669
H. E. Schwartz,
P. J. Barthel,
S. E. Moring,
Preview
|
PDF (188KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240101210
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
10. |
Importance of the retention index standards in determining the magnitude of McReynolds phase constants |
|
Journal of High Resolution Chromatography,
Volume 10,
Issue 12,
1987,
Page 670-671
C. F. Poole,
S. K. Poole,
R. M. Pomaville,
B. R. Kersten,
Preview
|
PDF (184KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240101211
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1987
数据来源: WILEY
|
|