1. |
Editorial |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 365-365
Preview
|
PDF (113KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040802
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
2. |
Fused silica capillary column GC/MS for the analysis of priority pollutants |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 366-384
A. D. Sauter,
L. D. Betowski,
T. R. Smith,
V. A. Strickler,
R. G. Beimer,
B. N. Colby,
J. E. Wilkinson,
Preview
|
PDF (1603KB)
|
|
摘要:
AbstractOperational characteristics have been determined for fused silica capillary column (FSCC) GC/MS as applied to “extractable” priority polutants. Chromatographic data show excellent relative retention time (RRT) intralaboratory precision and interlaboratory accuracy when multiple internal standards are empolyed. Potential chromatographic problems, such as column overload and “double peaking”, are addressed. Response factor relative standard deviations (RSD) at 50 ng for most of the extractable priority pollutants over the long term indicated precise determination (i.e. RSD generally ≤ 10%). Linearity was demonstrated over two orders of magnitude for FSCC GC/MS analysis of compounds with relatively low and high RF (response factor) values. Potential quantitative problems, such as saturation, are discussed. For certain aromatic priority pollutants interlaboratory RF agreement was observed. This was noted as perhaps the most important property of FSCC GC/MS analysis when the multiple internal standard approach is utilized. Determinations of extractable priority pollutants are directly compared for paced column GC/MS and FSCC GC/MS analysis of separate and composited extracts. For six extracts analyzed in triplicate, the latter configuration was shown to produce more consistent results. In view of the superior analysis logistics of composite extract FSCC GC/MS analysis, this approach was established as the preferred method for the analysis of priority pollutants classified as ex
ISSN:0935-6304
DOI:10.1002/jhrc.1240040803
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
3. |
A general framework for the measurement of band broadening properties of GC capillary columns |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 385-392
T. W. Smuts,
T. S. Buys,
T. G. du Toit,
J. W. Du Toit,
P. A. Torline,
Preview
|
PDF (495KB)
|
|
摘要:
AbstractIn the approach to the developement of a practical procedure for the evaluation of band broadening properties of gas capillary columns, the expression for the variance of a solute band is cast in a dimensionless form. This expression supplies the basis for a valid bench mark for column evaluation. Experimental results demonstrate the applicability of the method.
ISSN:0935-6304
DOI:10.1002/jhrc.1240040804
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
4. |
Simultaneous detection of total and halogenated hydrocarbons in complex environmental samples |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 393-397
James R. Dahlgran,
Preview
|
PDF (340KB)
|
|
摘要:
AbstractA state‐of‐the‐art gas chromatographic system for automatic simultaneous detection of halogenated and normal hydrocarbons has been developed, which consists of a standard Hewlett‐Packard 5880 with a fused silica capillary column, whose effluent is split between the standard flame ionization detector and a Tracor Hall electroconductivity detector. The system provedes excellent capillary chromatography results and high sensitivity for halogenated compounds (a detection limit of 1 ppm Archlor 1254 in fuel oil). Reliability has been provides in the daily analysis of complex environmental samples.Emergency response cleanup and the containment of hazardous chemical spills and chemical dump sites forces one to deal with samples that are very complex. The contain large numbers of naturally occurring organic compounds and varying types of organic pollutants. Capillary chromatographic techniques of gas chromatographic and gas chromatographic/mass spectrometric analyses are necessary to achieve the resolution required for the analysis of these
ISSN:0935-6304
DOI:10.1002/jhrc.1240040805
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
5. |
Thin‐layer chromatography with high‐boiling mobile phases.1. Investigation of the flow of the high‐boiling mobile phases |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 398-401
V. G. Berezkin,
S. L. Bolotov,
Preview
|
PDF (299KB)
|
|
摘要:
AbstractThis paper considers some aspects of a new TLC technique using a molten mobile phase which is solid under ambient conditions. The flow of high‐boiling mobile phase at elevated temperature in thin‐layer chromatography has been investigated and it is shown that the equation Zf2= kt is not applicable to migration of the high boiling mobile phase front. The flow stability of the high‐boiling mobile phase is noted. It is suggested on the basis of studies of concentration profiles of the solidified mobile phases by scanning photometers that the shape of the mobile phase concentration profile be taken into account in calculation of RfV
ISSN:0935-6304
DOI:10.1002/jhrc.1240040806
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
6. |
Dynamic headspace analysis of solid waste materials |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 404-405
R. S. Brazell,
M. P. Maskarinec,
Preview
|
PDF (195KB)
|
|
摘要:
AbstractA dynamic headspace stripping technique for the extraction of volatile organic compounds has been applied to a variety of solid and semisolid waste materials. A simple glass apparatus accommodates a wide range of sample sizes and allows for the volatiles to be stripped at elevated temperatures. Concentration on Tenax, followed by thermal desorption and analysis by fused silica capillary gas chromatography provides detailed information on the volatile content of waste samples of widely differing matrix composition.
ISSN:0935-6304
DOI:10.1002/jhrc.1240040807
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
7. |
Construction of an efficient fused silica capillary column effluent splitter for gas chromatography |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 406-408
Douglas W. Later,
Bob W. Wright,
Milton L. Lee,
Preview
|
PDF (163KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040808
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
8. |
Transducer for monitoring solvent plugs in capillary column preparation |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 409-410
J. A. Hembree,
M. S. McCracken,
Preview
|
PDF (134KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040809
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
9. |
In situ cross‐linking of the stationary phase in capillary columns. Part 1: Introduction and preparation of apolar columns |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 411-412
P. Sandra,
G. Redant,
E. Schacht,
M. Verzele,
Preview
|
PDF (179KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040810
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
10. |
The generation of HPLC signals by temperature pulses |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 8,
1981,
Page 413-414
Daniel P. Carney,
J. B. Phillips,
Preview
|
PDF (165KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040811
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981