|
1. |
Analysis of drugs and related compounds by capillary column GLC |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 381-394
W. J. A. Vandenheuvel,
J. S. Zweig,
Preview
|
PDF (1182KB)
|
|
摘要:
AbstractThis article describes the development of the application of capillary column GLC methods to steroids, prostaglandins and especially drugs and their metabolites in samples of biological origin. The wide variety – in terms of structures and pharmacological properties – of drugs now analyzed by capillary column GLC is made evident. Reasons for use of capillary rather than packed columns are given. The frequent use of and need for derivatization procedures prior to chromatography is emphasized. A bibliography of 83 references is included in the manuscr
ISSN:0935-6304
DOI:10.1002/jhrc.1240030802
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
2. |
Chromatogram surgery |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 395-399
G. Janssens,
Preview
|
PDF (393KB)
|
|
摘要:
AbstractA computer program is developed on a Hewlett‐Packard 3354 B Laboratory Automation System to eliminate background in gas and liquid chromatograms. Moreover undesired peaks, such as solvent peaks and spikes, can be excluded by selecting appropriate method parameters or by application of the integrator‐timed events directly affecting peak integration. Injudicious application of these codes deforms the chromatograms. Peaks can be labelled with retention times, areas or amou
ISSN:0935-6304
DOI:10.1002/jhrc.1240030803
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
3. |
High pressure liquid chromatography of standard and amniotic fluid phospholipids |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 400-404
J. Y‐K. Hsieh,
J. G. Turcotte,
J. Waraska,
D. Warburton,
W. Oh,
Preview
|
PDF (387KB)
|
|
摘要:
AbstractA method for the HPLC separation of phosphatidylglycerol (PG), phosphatidylinositol (PI), phosphatidylcholine (PC), and sphingomyelin (SPH) was achieved using five in‐series columns packed with LiChrosorb, Partisil, and μ‐Porasil adsorbents, a solvent mixture of chloroform/methanol/ammonium hydroxide (50 : 36 : 6.7, by volume), and a Pye LCM2 Moving Wire (FID) detector. The same phospholipid mixture was also separated using four μ‐Porasil columns with the same eluent and detector. The latter conditions were found to be suitable for the analysis of phospholipids obtained after centrifuging, extraction, and precipitation of surface‐active lipid components of patient amniotic fluid collected at amniocentesis section. The lecithin/sphingomyelin (L/S) ratios, determined by the HPLC method, correlated well with those determined by the TLC technique in four normal pregnancies, whereas results of shake tests did not correlate too well with L/S ratios determined by the above two chromatographic methods. Besides the lecithin/sphingomyelin ratio, the present method was able to supply additional information: the concentrations of phosphatidylglycerol and phosphatidylinositol, for prediction of fetal lung maturity, and the palmitic acid content of amniotic fluid phosphatid
ISSN:0935-6304
DOI:10.1002/jhrc.1240030804
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
4. |
Determination of adsorption by fluorescence in gas chromatography |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 405-410
O. Driessen,
J. Lugtenberg,
Preview
|
PDF (439KB)
|
|
摘要:
AbstractPMBF2, a pyrromethene pigment, can be used in gas chromatography. Because of its fluorescence, adsorption sites on glass columns and connections can be traced in situ. The compound can be employed to check the inertness of glass surfaces after deactivation procedures. Some applications are described.
ISSN:0935-6304
DOI:10.1002/jhrc.1240030805
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
5. |
All‐glass capillary T‐joints and manifolds |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 411-412
D. Müller,
H. Walther,
Preview
|
PDF (184KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030806
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
6. |
Nucleosides as stationary phases for the separation of dimethylnitrobenzene isomers by gas‐liquid chromatography |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 413-414
Aoi Ono,
Preview
|
PDF (147KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030807
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
7. |
Identification of volatile organic sulfur compounds in municipal sewage systems by GC/MS |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 415-416
W. A. König,
K. Ludwig,
S. Sievers,
M. Rinken,
K. H. Stölting,
W. Günther,
Preview
|
PDF (172KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030808
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
8. |
Comments on TZ: Its temperature dependence and relationship to other measures of column efficiency |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 416-418
Terrance A. Rooney,
Martin J. Hartigan,
Preview
|
PDF (223KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030809
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
9. |
GC and HPLC determination of meprobamate in plasma |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 419-420
R. N. Gupta,
F. Eng,
Preview
|
PDF (147KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030810
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
10. |
Some applications of quantitative HPTLC in pharmaceutical analysis |
|
Journal of High Resolution Chromatography,
Volume 3,
Issue 8,
1980,
Page 421-422
Margit Bidló‐Iglóy,
Tibor Horváth,
Preview
|
PDF (123KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240030811
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1980
数据来源: WILEY
|
|