1. |
Electron caputure detection in high‐speed narrow‐bore capillary gas chromatography: Fast and sensitive analysis of PCBs and pesticides |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 397-402
Peter G. van Ysacker,
Hans‐Gerd Janssen,
Henri M. J. Snijders,
Carl A. Cramers,
Preview
|
PDF (671KB)
|
|
摘要:
AbstractIn this work the combination of high‐speed narrow‐bore capillary GC with electron capture detection is evaluated. The make‐up gas flow rate is a key parameter in the successful coupling of narrowbore columns and ECD detection. The make‐up flow has to be as high as possible to eliminate peak tailing caused by the large detection cell volume. The sensitivities at these elevated make‐up flow rates (400 to 1000 ml/min), measured for some pesticides like HCB and dieldrin, were very good. Detection limits for these compounds of 0.1 pg were obtained, resulting in minimum detectable concentrations of approximately 0.2 ppb. The performance of the system is illustrated by several high‐speed analyses of environmentally relevant samples of PCBs and
ISSN:0935-6304
DOI:10.1002/jhrc.1240180702
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
2. |
The analysis of C4–C11hydrocarbons in naphtha and reformate with a new apolar fused silica column |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 403-412
Dietrich Estel,
Manfred Mohnke,
Frans Biermans,
Harald Rotzsche,
Preview
|
PDF (560KB)
|
|
摘要:
AbstractThis paper deals with the separation of alkanes, naphthenes, and aromatic compounds in naphtha and reformate, on a newly developed apolar high resolution GC column. The selectivity of this apolar phase has been compared with those of squalane, DB‐1, and SE‐30. A total of 95 hydrocarbons were reliably identified, mostly by GC‐MS. Repeated measurements of Kováts retention indices are presented as evidence for the reproducible manufacture of fused silica columns coated with this
ISSN:0935-6304
DOI:10.1002/jhrc.1240180703
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
3. |
GLC‐MS analysis of the fatty acids of the seed oil, triglycerides, and cyanolipid ofPaulliania elegans(Sapindaceae) – a rich source ofcis‐13‐eicosenoic acid (paullinic acid) |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 413-416
Volker Spitzer,
Preview
|
PDF (393KB)
|
|
摘要:
AbstractThe fatty acids of the total lipids, triglycerides, and the cyanolipid ofPaullinia elegans(Sapindaceae) have been analyzed as their methyl esters and 4,4‐dimethyloxazoline derivatives by gas chromatography‐mass spectrometry. It was shown that the gas chromatographic separation of the oxazoline derivatives was sufficient to ensure the correct identification of the monoenic fatty acid positional isomers. Stereochemistry of the double bonds has been confirmed by infrared and13C‐nuclear magnetic resonance (NMR) spectroscopy.cis‐13‐Eicosenoic Acid (Paullinic acid) (44.4%) andcis‐11‐octadecenoic acid (cis‐vaccenic acid) (19.8%) were found to be the main components beside other monoenoic acid positional isomers. The cyanolipid ofP. eleganswas identified as 2,4‐dihydroxy‐3‐methylenebutyronitrile derivative by IR,1H‐NMR,13C‐NMR spectroscopy and was quantified by1H
ISSN:0935-6304
DOI:10.1002/jhrc.1240180704
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
4. |
Microwave extraction in analytical chemistry of pollutants: Polychlorinated biphenyls |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 417-421
Francis I. Onuska,
Ken A. Terry,
Preview
|
PDF (592KB)
|
|
摘要:
AbstractThe microwave energy produced by a high intensity microwave oven was used to extract polychlorinated biphenyls (PCB) from water samples. This static method was compared with liquid‐liquid extraction to determine the optimum and limiting conditions in extraction processes. The sample size and sample container shape determine the temperature profiles in the sample. Using a 500 mL sample size, the detection limit is in the low ng/L range when an electron capture detector is employe
ISSN:0935-6304
DOI:10.1002/jhrc.1240180705
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
5. |
Separation and determination ofm‐phenoxybenzaldehyde reaction products by capillary gas chromatography |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 422-424
Sajid Husain,
Ponnapalli Nageswara Sarma,
Sankarayya Swamy,
Preview
|
PDF (209KB)
|
|
摘要:
AbstractA capillary GC method employing an internal standard has been developed and successfully used for quantitative determination both of the raw materials used for the manufacture ofm‐phenoxybenzaldehyde and for the components of the reaction mixtures obtained at various stages of the development of the process. A complete analysis can be performed in a single temperature programmed ru
ISSN:0935-6304
DOI:10.1002/jhrc.1240180706
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
6. |
Chromatographic methods for the analysis of crude tall‐oil |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 425-432
José M. F. Nogueira,
José L. C. Pereira,
Pat Sandra,
Preview
|
PDF (475KB)
|
|
摘要:
AbstractChromatographic methods currently used for isolation, separation, and identification of the components of crude tall‐oil have been reviewed, and their resolution and analytical methodology compared. Sample introduction by cold on‐column, rather than vaporizing, injection provides good reproducibility and operational convenience for capillary GC analysis. Size exclusion chromatography for isolation followed by capillary GC‐MS for identification, gave the best performance for analysis of acidic and dimeric comp
ISSN:0935-6304
DOI:10.1002/jhrc.1240180707
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
7. |
On‐line reversed‐phase liquid chromatography‐capillary gas chromatography using a programmed temperature vaporizer as interface |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 433-438
F. Javier Señoráns,
Marta Herraiz,
Javier Tabera,
Preview
|
PDF (545KB)
|
|
摘要:
AbstractAn on‐line reversed‐phase LC‐GC method involving the use of a Programmed Temperature Vaporizer (PTV) as interface is used for the rapid analysis of sterols. The experimental procedure requires only the use of commercial HPLC and GC equipments and a Rheodyne valve. The LC preseparation can be performed satisfactorily even with aqueous eluents containing up to 25% water. Factorial experimental design is applied to investigate the sensitivity achievable in the analysis with some variables (adsorbent material used in the PTV, particle size and plug length) being considered at two different levels. As a result, the sensitivty can be increased by a factor as large as 35 merely by performing the analysis under the experimental conditions giving the highest response. The use of the proposed configuration allows the transfer of up to 1050 μL from LC into the GC system, 1400 μL/min being the speed of sample introduction. The proposed procedure was succesfully applied to the analysis of real
ISSN:0935-6304
DOI:10.1002/jhrc.1240180708
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
8. |
Simultaneous determination of the electroosmotic flow and pseudo‐stationary phase migration time in electrokinetic capillary chromatography |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 439-442
Scott A. Kuzdzal,
Jeffrey J. Hagen,
Curtis A. Monning,
Preview
|
PDF (460KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240180709
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
9. |
Separation of highly hydrophobic compounds in MEKC with an ionic polymer |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 443-445
Shenyuan Yang,
Jefferson G. Bumgarner,
Morteza G. Khaledi,
Preview
|
PDF (290KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240180710
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
10. |
Supercritical fluid extraction of phenoxy acids from water |
|
Journal of High Resolution Chromatography,
Volume 18,
Issue 7,
1995,
Page 446-448
Ali Daneshfar,
Mohsen Barzegar,
Mehdi Ashraf‐Khorassani,
Joseph M. Levy,
Preview
|
PDF (285KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240180711
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1995
数据来源: WILEY
|
|