|
1. |
Summaries |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 549-549
Preview
|
PDF (110KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240020902
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
2. |
Design of a microprocessor‐controlled automated injection system for the analysis of gas phase cigarette smoke using glass capillary columns |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 551-557
Milton E. Parrish,
Charles T. Higgins,
D. R. Douglas,
Duane C. Watson,
Preview
|
PDF (545KB)
|
|
摘要:
AbstractAn automatic injection system for the analysis of gas phase smoke has been designed and evaluated using the microprocessor‐controlled Hewlett‐Packard 5830 gas chromatograph. The cryogenic preconcentration trap was constructed from relatively inexpensive and readily available materials. It was determined that the use of the preconcentration trap, as opposed to condensing the smoke on the head of the cold (‐50°C) chromatographic column, significantly enhanced the resolution of the more volatile gas phase components. Data are presented which illustrate the injection system characteristics. In addition, chromatograms of gas phase smoke are presented which demonstrate the effectiveness of this tec
ISSN:0935-6304
DOI:10.1002/jhrc.1240020903
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
3. |
High resolution gas chromatography/mass spectrometric characterization of urinary metabolites of N,N‐diethyl‐m‐toluamide (DEET) in man |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 558-562
Anthony Wu,
M. Lynn Pearson,
David L. Shekoski,
Ricardo J. Soto,
Richard D. Stewart,
Preview
|
PDF (270KB)
|
|
摘要:
AbstractStudies of the pharmacology and toxicology of the popular insect repellant, N,N‐diethyl‐m‐toluamide (DEET), have largely been done in animal models using radioactive tracing without the structural elucidation of its metabolites.This paper describes a high resolution gas chromatography/mass spectrometry (GC/MS) technique and reports the results of the preliminary characterization of the metabolites of DEET in the urine of a 30‐year‐old man who had been exposed to DEET contained in a commercial product. The metabolites were extracted and separated with an OV‐101 glass capillary column, 30 m × 0.3 mm, and mass spectrometric elucidations were carried out with both Electron Impact (EI) and Chemical Ionization‐Methane (MCI) modes.Oxidation of the benzylic moiety and hydroxylation of the sidechain of DEET molecules appeared to be the predominate routes of metabolism in man. The artifacts were
ISSN:0935-6304
DOI:10.1002/jhrc.1240020904
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
4. |
Pressure and flow changes in vaporizing GC injectors during injections and their impact on split ratio and discrimination of sample components |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 563-569
K. Grob,
H. P. Neukom,
Preview
|
PDF (541KB)
|
|
摘要:
AbstractThe effect of pressure changes in the vaporizing GC injectors on the split ratio is investigated. It is shown that the true split ratio depends on a number of parameters and may strongly differ from the split ratio expected from the flows set before injection. Quantitation with split injection based on external standards has to be carried out very carefully (or should be replaced by the method with internal standard). The split ratio may strongly change during the splitting of the sample. There are a number of mechanisms causing some sample components to be retarded and hence to be split by a different ratio. The split injector is a device which still requires further development.
ISSN:0935-6304
DOI:10.1002/jhrc.1240020905
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
5. |
A rapid, new and direct method for isolation and measurement of porphyrins in biological samples by high performance liquid chromatography |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 570-574
Edwin Englert,
Anthony W. Wayne,
Eugene E. Wales,
Richard C. Straight,
Preview
|
PDF (364KB)
|
|
摘要:
AbstractReversed‐phase high performance liquid chromatography on microparticulate columns of octadecylsilane with elution by a gradient of acetonitrile in phosphate buffer, pH 7.5, separated porphyrin free acids directly in urine for the first time. Interfering fluorescence was removed with a precolumn of large particle size at acid pH. Peak area fluorescence by the method of standard addition was related linearly to amount of a porphyrin from 5 to 60 nanograms. The method was reproducible to ± 13%, able to detect 0.3 nanograms of a porphyrin in a 1 ml urine sample in 45 minutes, and capable of detecting the typical clinical patterns of normal and porphyrinuric urines. Modifications make the method applicable to measurements in other biological samples and to research separations. With the added rapidity of analysis, the method could expand porphyrin analysis in routine clinical medici
ISSN:0935-6304
DOI:10.1002/jhrc.1240020906
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
6. |
Minimizing solvent peak tailing by pressure equalization into a buffer volume. A simple device applied to an easily removable splitless injector for capillary GC |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 576-576
P. Baeckström,
M. Lindström,
Preview
|
PDF (73KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240020907
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
7. |
Apparatus and technique for preparation of high performance support and packings for gas chromatography |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 577-578
A. A. Spark,
Preview
|
PDF (181KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240020908
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
8. |
Hydrogen as the carrier gas? are you crazy? |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 578-579
Bjørn Olufsen,
Preview
|
PDF (143KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240020909
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
9. |
An improved fluidizer for the preparation of gas chromatographic column packings |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 580-580
S. Meléndez‐R,
W. C. Parker,
Preview
|
PDF (83KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240020910
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
10. |
Relationship between retention indices and substituent constants of phenols on polarl stationary phases |
|
Journal of High Resolution Chromatography,
Volume 2,
Issue 9,
1979,
Page 581-582
A. Radecki,
J. Grzybowski,
H. Lamparczyk,
A. Nasal,
Preview
|
PDF (117KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240020911
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1979
数据来源: WILEY
|
|