|
1. |
Thermostable persilylated polar glass capillary columns by the ammonia‐etching method |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 433-436
H. Traitler,
A. Prévôt,
Preview
|
PDF (275KB)
|
|
摘要:
AbstractStatic ammonia etching has been used to effect regular surface roughening of glass capillaries. Following such treatment, polar phases could be coated after persilylation with varioussilylation agents such as hexamethyl‐, tetramethyldiphenyl‐, and tetra‐ phenyldimethyldisilazane, respectively. This method produces columns of high thermostability, which is limited only by the maximum applicable temperature for the phase i
ISSN:0935-6304
DOI:10.1002/jhrc.1240040902
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
2. |
Glass capillary column chromatography of mixed derivatives of primary prostaglandins, 6‐keto prostaglandin F1αand thromboxane B2 |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 437-443
J. Roselló,
E. Gelpi,
M. Rigaud,
J. C. Breton,
Preview
|
PDF (542KB)
|
|
摘要:
AbstractThis work describes the use of glass capillary columns (GCC) in the rapid concurrent analysis of primary prostaglandins (PGs) (e. g. PGE2, PGE2, PGF2α) and other functionally significant metabolites of arachidonic acid (AA) such as TXB2and 6‐keto PGF1α. The use of a new multistep mixed derivatization approach that generates the methyl esters ofn‐butylboronate, pentafluorobenzyloxime, trimethylsilyl ether derivatives of these compounds remarkably simplifies the GC profiling of the three main pathways of AA metabolism (PGs, thromboxane, and prostacyclin). Furthermore, isomeric species giving very similar or identical mass spectral patterns can be easily identified by their relative retention times on high efficiency capillary co
ISSN:0935-6304
DOI:10.1002/jhrc.1240040903
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
3. |
Effect of some parameters on the liquid chromatographic separation of biogenic amines and their metabolites |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 444-447
N. Lammers,
J. Zeeman,
G. J. De Jong,
Preview
|
PDF (273KB)
|
|
摘要:
AbstractThe liquid chromatographic separation of some biogenic amines and their metabolites with a reversed‐phase ion‐pair system has been optimized. The effects of the nature of the stationary phase, the column temperature, the pH, and the ion‐pair reagent concentration of the mobile phase have been investigated. The most striking result is the influence of the column temperature on select
ISSN:0935-6304
DOI:10.1002/jhrc.1240040904
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
4. |
High‐performance liquid chromatography with continuous gradient elution in screening for unknown metabolites of butoprozine directly in dog bile |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 448-453
F. Overzet,
B. F. H. Drenth,
R. A. de Zeeuw,
Preview
|
PDF (458KB)
|
|
摘要:
AbstractThis paper describes the screening for metabolites of butoprozine, a new anti‐anginal drug, in dog bile by means of reverse‐phase HPLC. Although it does involve a simple clean‐up step to remove a substantial amount of endogenous bile compounds, this screening method nevertheless avoids extraction of metabolites and thus allows all metabolites to be introduced into the chromatographic system. A single run of 100 minutes from 100% water to 100% methanol in a linear gradient effects adequate separation of the great majority of metabolites without interference from remaining endogenous compounds.Two methods of differentiating between metabolite peaks and endogenous peaks have been worked out. The first one makes use of14C‐labeled butoprozine by measuring the amount of radioactivity in the column effluent while simultaneously recording the UV absorbance. The second method compares continuous gradient chromatograms of bile recorded before and after butoprozine administration under very similar conditions. The latter method can be applied to both radioactive and non‐radioactive
ISSN:0935-6304
DOI:10.1002/jhrc.1240040905
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
5. |
An approach to the prediction of retention times in liquid chromatography |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 454-460
T. Hanai,
C. Tran,
J. Hubert,
Preview
|
PDF (521KB)
|
|
摘要:
AbstractThe utility ofRekker'shydrophobic fragmental constant has been examined for optimization of reversed‐phase mode liquid chromatographic separations. The chromatographic behavior of about 60 non‐ionic compounds was measured in different acetonitrile/water mixtures and the logarithm of their capacity factors (log k) was correlated with their calculated hydrophobicities (log P). Linear relations were found in each case between log k and log P. The slope of the various lines was related to the percentage concentration of acetonitrile in the mobile phase. It was shown that, by using nine stand ard compounds and measuring their capacity factors in five eluents with different acetonitrile concentrations, the retention time could be predicted for 60 compounds. Calculation of the concentration of the organic modifier was also possible in a system of well coated octadecyl bonded packings with acetonitrile/water mixtures as eluent. Prediction of the capacity factor was accomplished to within 5% er
ISSN:0935-6304
DOI:10.1002/jhrc.1240040906
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
6. |
Accurate mass measurement in capillary GC‐MS at low resolution; separation and mass spectrometric characterization of two isomeric clavams |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 463-464
R. J. Edser,
J. L. Gower,
G. D. Risbridger,
Preview
|
PDF (131KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040907
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
7. |
Comparison of solubility of naphthols in mixtures of water and methanol and their retention in reversed‐phase liquid/solid systems |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 465-466
M. Bieganowska,
E. Soczewiński,
Preview
|
PDF (162KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040908
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
8. |
Investigation of the low temperature effect in micro high performance liquid chromatography‐open tubular microcapillary column |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 466-468
K. Jinno,
Y. Hirata,
Preview
|
PDF (229KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040909
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
9. |
Valve injection in micro‐HPLC |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 469-470
T. Takeuchi,
D. Ishii,
Preview
|
PDF (141KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040910
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
10. |
HPLC of triglycerides using UV detection |
|
Journal of High Resolution Chromatography,
Volume 4,
Issue 9,
1981,
Page 471-473
B. G. Herslöf,
Preview
|
PDF (186KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240040911
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1981
数据来源: WILEY
|
|