|
1. |
Effects of organic mobile phase modifiers in micellar electrokinetic capillary chromatography |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 554-559
J. Gorse,
A. T. Balchunas,
D. F. Swaile,
M. J. Sepaniak,
Preview
|
PDF (446KB)
|
|
摘要:
AbstractThe addition of 1–20% (v/v) of methanol or acetonitrile as organic modifier to the mobile phase in a micellar electrokinetic capillary chromatographic (MECC) system, containing sodium dodecyl sulfate and a buffer, is shown to extend the elution range and thus increase the peak capacity of a given system. Although the net change in the elution range parameter, to/tmc, is essentially the same for both modifiers, the acetonitrile‐modified system exhibits much faster elution times for the polar and non‐polar test solutes employed in this study. Retention, as measured by the capacity factor, is generally decreased with the increase of an organic modifier, just as in conventional reversed phase chromatography. However, changes in selectivity as a function of the added modifiers are noted among polar and non‐polar solutes as well. The efficiency of these MECC systems is increased with the addition of either organic m
ISSN:0935-6304
DOI:10.1002/jhrc.1240110802
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
2. |
Co‐solvent effects for preventing broadening or loss of early eluted peaks when using concurrent solvent evaporation in capillary GC. Part 2:n‐Heptane inn‐pentane as an example |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 560-565
Konrad Grob,
Eugen Müller,
Preview
|
PDF (481KB)
|
|
摘要:
AbstractCo‐solvent effects are applied to allow use of concurrent solvent evaporation for applications requiring analysis of compounds eluted less than some 50° above the column temperature during sample introduction,i.e.at oven temperatures below some 100–120°C. Required conditions such as GC even temperature, concentration of the co‐solvent and length of the uncoated pre‐column (retention gap) are studied theoretically as well as experimentally for the case ofn‐heptane as co‐solven
ISSN:0935-6304
DOI:10.1002/jhrc.1240110803
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
3. |
Retention characteristics of volatile compounds on tenax TA |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 566-576
I. Maier,
M. Fieber,
Preview
|
PDF (913KB)
|
|
摘要:
AbstractThe chromatographic separation properties of long, thin adsorption tubes enable substance‐specific quantitative enrichment and reduction to be achieved when sampling and thermal desorption are carried out in the same flow direction.The specific retention volumes, and also the breakthrough and peak end volumes, of 69 compounds in the boiling range between‐164 and 126°C and of a relative molecular mass between 16 and 119 were determined at temperatures between 30 and 130°C: normal alkanes, isoalkanes, cycloalkanes, alkenes, polyenes, alkynes, aromatics, ethers, alcohols, aldehydes, ketones, carboxylic acids and their esters, nitroalkanes, O‐heterocycles, S‐heterocycles, chloroalkanes, water, nitrogen monoxide, nitrogen dioxide, carbon dioxide, and sulfur dioxide.The correlation between adsorbent temperature and specific retention volume of these components, presented in the form of diagrams, permits the required quantity of adsorbent to be determined for a given sample volume. Contrary to literature sources, even extremely volatile compounds such as propane, propene, methanol, formaldehyde, formic acid, and chloromethane can be quantitatively retained on Tenax provided the operating conditions are appropriately
ISSN:0935-6304
DOI:10.1002/jhrc.1240110804
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
4. |
Gas chromatographic separations on packed microcolumns using various 10 μm support particles |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 577-583
V. Lagesson,
J. M. Newman,
Preview
|
PDF (398KB)
|
|
摘要:
AbstractPacked columns using 10 μm HPLC‐packing materials as supports for various liquid phases have been studied. The glass columns used were 80 mm long (o.d. 3 mm and i.d. 1.5 mm), the amount of solid support in the column being approximately 0.15 g. A. wide variety of separation characteristics were obtained by combining support material of various surface areas, chemically bonded surfaces, applied liquid phases, and various liquid phase loadings. This type of column is also characterized by a very short gas hold‐up time, leading to possibilities for relatively fast separations. Other advantages are high sample loading, high sample capacity, and low operating
ISSN:0935-6304
DOI:10.1002/jhrc.1240110805
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
5. |
Reverse search spectrum comparison and elution profile analysis in GC‐MS data set |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 585-587
I. Hazai,
Preview
|
PDF (248KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240110806
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
6. |
GC and HPLC analysis of alkyl triphenylphosphonium salts used in the wittig reaction |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 587-588
R. C. Harden,
G. A. Harvey,
D. M. Rackham,
Preview
|
PDF (144KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240110807
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
7. |
Progress in all‐glass stream splitting systems in capillary gas chromatography. Part II: Application of a simple “glass‐cap‐cross” as inlet splitter for on‐column injection |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 589-592
W. Bretschneider,
P. Werkhoff,
Preview
|
PDF (286KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240110808
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
8. |
Dimensionless representation of concentration profiles in chromatography‐application to preparative chromatography |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 592-594
A. S. Said,
G. A. Al‐Enezi,
M. G. Eidan,
Preview
|
PDF (236KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240110809
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
9. |
New alternative to normal phase HPLC automation using methylene chloride mobile phases: A synchronized dual switching valve loop injection system |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 595-598
E. M. Fujinari,
Preview
|
PDF (326KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240110810
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
10. |
Perturbation of baseline in HPLC analysis as the consequence of sample injection |
|
Journal of High Resolution Chromatography,
Volume 11,
Issue 8,
1988,
Page 598-600
B. Buszewski,
K. Šebeková,
Preview
|
PDF (250KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240110811
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1988
数据来源: WILEY
|
|