|
1. |
Gas chromatographic separation of sugars by on‐column injection on glass capillary columns |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 558-562
H. Traitler,
S. Del Vedovo,
T. F. Schweizer,
Preview
|
PDF (312KB)
|
|
摘要:
AbstractSugars were separated gas chromatographically on short apolar glass capillary columns by using cold, on‐column injection (OCI) techniques. After silylation, oligomers up to the hexasaccharides could be efficiently separated in resonable retention times. Response factors of silylated sugars were determined as a function of varying sample amounts and concentrations. The optimum injection amount was found to be 1 μl in heptane as solve
ISSN:0935-6304
DOI:10.1002/jhrc.1240071002
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
2. |
Analysis of mutagenic amino acid pyrolyzates with a fused silica capillary column |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 563-565
H. Schunk,
T. Hayashi,
T. Shibamoto,
Preview
|
PDF (175KB)
|
|
摘要:
AbstractIn this study, application of a fused silica capillary column for analysis of major mutagenic heterocyclic compounds found in cooked foods was investigated.
ISSN:0935-6304
DOI:10.1002/jhrc.1240071003
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
3. |
Determination of tetraiodothyronine in serum by HPLC and electrochemical detection |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 566-569
E. Besenfelder,
Preview
|
PDF (329KB)
|
|
摘要:
AbstractTetraiodo‐L‐thyronine (T4) in human serum was determined by HPLC using a nonphysiological internal standard. For sample preparation, a cation exchange resin, RP‐chromatography on C‐18 or phenylphase, and electrochemical detection (Metrohm 656 or BAS‐LC 4 A) were employed. The mobile phase (0.8 ml/min) was 10 mMH3PO4/CH3OH (40/60 v/v) or 10 mMH3PO4/CH3CN (70/30 v/v, 1.5 ml/min), the voltage applied 800 mV. The coefficient of variation (day to day) was 6.8% (N = 40); concentrations of T4 found were 11 to 20% lower than those obtained by two different commercially available imm
ISSN:0935-6304
DOI:10.1002/jhrc.1240071004
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
4. |
Preparative HPLC. Part 1: A comparison of three types of equipment for the purification of steroids |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 570-576
S. A. Matlin,
L. Chan,
Preview
|
PDF (605KB)
|
|
摘要:
AbstractTwo commercial preparative liquid chromatographs have been evaluated for gram‐scale purification of steroid esters. The Jobin‐Yvon and Waters chromatographs both allow fast separations. Neither system has a high intrinsic column efficiency, but the resolving power of the Waters system can be increased by the use of recycle. A laboratory‐assembled preparative liquid chromatograph is described which is economical both in construction and operation, versatile, and considerably more efficient than the two commercial alternatives for single runs on up to a gram
ISSN:0935-6304
DOI:10.1002/jhrc.1240071005
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
5. |
Valveless flow switching using constant flow controllers |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 577-577
D. J. Abbott,
Preview
|
PDF (83KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240071006
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
6. |
Flexible capillary effluent splitter of the “all‐glass” type |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 578-579
F. Etzweiler,
Preview
|
PDF (149KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240071007
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
7. |
Non‐suppressed ion chromatography of carbonate and nitrite on steel surfaces |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 580-581
B. E. Andrew,
Preview
|
PDF (139KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240071008
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
8. |
Analysis of 1‐ and 4‐nitropyrene and 1‐nitropyrene‐d9via fused silica GC combined with negative ion atmospheric pressure ionization mass spectrometry |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 581-583
W. A. Korfmacher,
D. W. Miller,
Preview
|
PDF (226KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240071009
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
9. |
HPLC analysis of steroid esters |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 584-586
S. A. Matlin,
L. Chan,
M. A. Prazeres,
Preview
|
PDF (231KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240071010
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
10. |
Gas chromatographic determination of residual ethylene oxide in gas‐sterilized, medical‐grade plastics |
|
Journal of High Resolution Chromatography,
Volume 7,
Issue 10,
1984,
Page 587-589
D. De Rudder,
J. P. Remon,
E. De Graeve,
R. Van Severen,
P. Braeckman,
Preview
|
PDF (205KB)
|
|
ISSN:0935-6304
DOI:10.1002/jhrc.1240071011
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1984
数据来源: WILEY
|
|