1. |
The Diffraction Theory of the Aberrations of Stigmatic Orthomorphic Optical or Electron Optical Systems Containing Toric Lenses or Quadrupoles |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 237-251
Preview
|
PDF (642KB)
|
|
摘要:
The diffraction theory of the aberrations of optical systems with an axis of rotational symmetry is now thoroughly established, and the extension to kindred electron optical systems is straightforward. In electron optics, however, certain types of systems containing quadrupoles are of importance, and such systems suffer from aberrations which affect only very oblique rays in axially symmetrical systems. The distortions of the wave surface which correspond to these new aberrations are listed in the present note, and Nijboer's expressions for the consequent disturbances in the image plane of a rotationally symmetrical system are supplemented accordingly. Only the special case—which is, nevertheless, an important one—of stigmatic systems, producing an image free of first-order distortion‡, is considered. The analysis is applicable to electron optical orthogonal systems containing quadrupoles and optical systems containing parallel toric lenses alike.
ISSN:0030-3909
DOI:10.1080/713817886
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|
2. |
Focomètre Interférentiel |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 253-266
Maurice Françon,
Roland Prat,
Preview
|
PDF (820KB)
|
|
摘要:
Le focomètre interférentiel décrit permet de mesurer la puissance d'une lentille sans qu'il y ait de mise au point à effectuer, d'où l'avantage principal de l'appareil au point de vue fatigue d'utilisation. Il suffit de regarder un système de franges à l'oeil nu et de mettre en coïncidence une frange, successivement sur 2 repères. Une graduation donne immédiatement la puissance de la lentille. L'appareil est particulièrement adapté aux mesures en lunetterie. Le dispositif produisant les franges est un interféromètre à polarisation utilisant la méthode différentielle. La description du focomètre interférentiel est suivie d'une étude des éléments biréfringents employés dans l'appareil.
ISSN:0030-3909
DOI:10.1080/713817883
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|
3. |
Messung der Absorptionsfarben von Mineralen und Ihre Auswertung |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 267-279
Preview
|
PDF (1099KB)
|
|
摘要:
Die nun vollständig erschienene DIN-Farbenkarte DIN 6164 ist ein Farbmessmittel von hoher Qualität, wenngleich auch sie noch Wünsche often lässt. Zur Auswertung und Veranschaulichung der Messergebnisse werden neue Vorschläge gerrtacht, insbesondere zur modellmässigen Darstellung der räumlichen Beziehungen in cter Farbenwelt. Dies ist besonders nötig und vorteilhaft, wenn nicht nur bestimmte Farbörter, sondern ganze Farbbereiche, z. T. mit verlaufenden Grenzen beschrieben werden sollen. Diese Möglichkeiten werden am Beispiel von Mineral-absorptionsfarben, speziell am Begrift der ‘Türkisfarbe’, erläutert und durchbehandelt.
ISSN:0030-3909
DOI:10.1080/713817885
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|
4. |
Eindimensionales Schlierenverfahren Hoher Genauigkeit |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 281-285
Wolfgang Dersch,
Hans Wolter,
Preview
|
PDF (343KB)
|
|
摘要:
Um die Schwierigkeiten des Philpot-Svenssonschen und verwandter Schlierenverfahren zu vermeiden, wählt man eine Anordnung, bei der die unvermeidbaren Beugungserscheinungen einfach gestaltet sind und deshalb eine exakte Auswertung erlauben. Der Gewinnfaktor der Genauigkeit beträgt 14 bis 19.
ISSN:0030-3909
DOI:10.1080/713817889
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|
5. |
Refractive Indices of Fluoride Interference Films on Thorium Dioxide |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 287-294
Preview
|
PDF (494KB)
|
|
摘要:
Optically isotropic interference films of uniform thicknesses were formed on the flat surface of oriented, single-crystalline thorium dioxide by reaction with anhydrous gaseous hydrogen fluoride. The films were studied by immersion spectrophotometry, from which the optical constants were determined as a function of wavelength, order of interference, angle of incidence and plane of polarization.
ISSN:0030-3909
DOI:10.1080/713817891
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|
6. |
Über Einen Zusammenhang Zwischen Wellenoptik und Geometrischer Optik |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 295-299
Hansjoachim Drucks,
Preview
|
PDF (316KB)
|
|
摘要:
Die Strahlenoptik wird in der Literatur bekanntlich als Grenzfall der Wellenoptik für verschwindende Wellenlänge hergeleitet. Daß die Strahlenoptik nicht nur ein Grenzfall der Wellenoptik ist, wird in dieser Arbeit gezeigt. Unabhängig von der Wellenlänge wird für den Fall, daß die Amplitude der Welle durch eine harmonische Funktion dargestellt werden kann, eine notwendige und hinreichende Bedingung für einen Übergang von der Wellen- zur Strahlenoptik bewiesen. Die Verknüpfung von harmonischen Funktionen mit den Lösungen der Differentialgleichung der Wellenoptik wird durch die Arbeiten von Stefan Bergman nahegelegt.
ISSN:0030-3909
DOI:10.1080/713817887
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|
7. |
The Oculomotor Response to Small Target Replacements |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 301-314
Preview
|
PDF (952KB)
|
|
摘要:
The speed and accuracy with which a small target (from 7·5 min to 15 min) is tracked by visual axis has been investigated using an after-image method of observing eye-movements (27 subjects). Complementary measurements (using a contact lens and mirror) were made on accuracy of fixation and time of response (two subjects). A range of tracking performance is found: at one extreme (called Type A subject) a target displacement of 7·5 min is compensated in 1 sec by a saccade. At the other extreme (which we call Type B) compensation requires up to 10 sec and only the larger target displacements stimulate a compensating saccade. For subjects of Type B, the time required for compensation increases rapidly as the size of saccade is reduced so as to indicate a 'dead-space' within which target movements are not compensated. The size of the dead. space was measured for two subjects, yielding values of 5·5 min and 9·8 min. Mechanisms that maintain the direction of the visual axis are discussed in the light of these findings.
ISSN:0030-3909
DOI:10.1080/713817890
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|
8. |
Some Properties of Multi-layer Films with Periodic Structure |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 315-331
Preview
|
PDF (832KB)
|
|
摘要:
The properties of periodical multi-layers are surveyed in respect of width, shape and phase change of the stopping band. It is shown that for a given range of possible refractive indices the widest stopping band is obtained with, in effect, a two-layer fundamental period with the maximum ratio of refractive indices; this can also be expressed as a symmetrical three-layer period with the same stopping band width, but with different properties. The application of the results obtained to the polarizing beam-splitters is briefly indicated.
ISSN:0030-3909
DOI:10.1080/713817888
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|
9. |
Index of Authors (with titles) |
|
Optica Acta: International Journal of Optics,
Volume 11,
Issue 4,
1964,
Page 333-334
Hansjoachim Drucks,
Preview
|
PDF (125KB)
|
|
ISSN:0030-3909
DOI:10.1080/713817884
出版商:Taylor & Francis Group
年代:1964
数据来源: Taylor
|