|
1. |
HLA‐Antibody‐Induced14C‐Serotonin Release from Platelets: |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 65-78
D. Heinrich,
S. Gutschank,
C. Mueller‐Eckhurdt,
Preview
|
PDF (692KB)
|
|
摘要:
Abstract.The prerequisites and kinetics of HLA‐antibody‐induced14C‐serotonin release from platelets were investigated with five HLA‐specific antisera. By studying the influence of incubation time, temperature, pH, platelet count, stirring and extent of platelet labeling, optimal results were obtained after 30 (to 60) min of incubation at 37°C, pH 7.5–8.0, under constant stirring (400 rpm). Optimal platelet counts varied between 160,000 and 400,000/μl depending on the antiserum applied. A comparison of the amount of14C‐serotonin released by different antisera from washed platelets and from platelets in platelet‐rich plasma suggests that plasma components ‐ most likely complement ‐ may additionally influence the results. Based on these experiments, a standardized microtechnique of HLA‐antibody‐induced14C‐seroton
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02236.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
2. |
Laboratory and Clinical Effects of the Infusion of ACD Solution During Plateletpheresis |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 79-87
Peter R. Olson,
Carol Cox,
Jefrey McCullough,
Preview
|
PDF (556KB)
|
|
摘要:
Abstract.Transfusion of massive amounts of citrate anticoagulated blood during plateletpheresis with the intermittent flow centrifuge can produce symptoms and electrocardiographic changes suggestive of hypocalcemia. Following 15 procedures the ionized calcium decreased by an average of 32.4%, the average postpheresis serum citrate was 26.7 mg/dl and the QT interval was prolonged by 0.08 sec. Twelve plateletphereses performed with half‐strength ACD solution caused an average decrease in ionized calcium of 16%, serum citrate levels of 12.5 mg/dl and QT prolongation of 0.04 sec. No donors experienced significant clinical symptoms with citrate infusion rates of less than 65 mg/kg/h. Solutions with citrate concentrations lower than ACD‐A should be developed for use in plateletpheresis procedures involving citrate infusion rates greater than t
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02237.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
3. |
Clinical and Immunological Studies on Healthy Blood Donors Hepatitis B Antibody Carriers |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 88-92
J. Cianciara,
H. Swiderska,
J. Slusarczyk,
T. Loch,
Preview
|
PDF (326KB)
|
|
摘要:
Abstract.Ten healthy blood donors persistently seropositive for anti‐HBs and without a history of clinically overt viral hepatitis were studied. While physical examination and biochemical liver function tests exhibited normal values in all cases, immunologic studies revealed coexistence of a long‐term anti‐HBs carrier state with the presence of cell‐mediated immunity to HBV antigens and autoantibodies in some. These results suggest a complex immunologic phenomenon underlying the development of the anti‐HBs carr
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02238.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
4. |
Studies on New Process Procedures in Plasma Fractionation on an Industrial Scale |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 93-96
H. Friedli,
E. Fournier,
T. Volk,
P. Kistler,
Preview
|
PDF (239KB)
|
|
摘要:
Abstract.Two semipermeable membrane systems for the production of salt‐poor, concentrated human albumin preparations for clinical use are compared. A very efficient method, on an industrial scale, is obtained by the combination of gel filtration and ultrafiltratio
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02239.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
5. |
A Chromatographic Procedure for the Purification of Human Plasma Albumin |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 97-107
J. M. Curling,
J. Berglöf,
L.‐O. Lindquist,
S. Eriksson,
Preview
|
PDF (1075KB)
|
|
摘要:
Abstract.Albumin is obtainable from human blood plasma by an ion exchange chromatographic procedure in a yield of about 95% and a purity well above Pharmacopoeia requirements. Cryosupernatant, factor IX depleted plasma is precipitated with 12 and 25% w/v polyethylene glycol 4000. The second precipitate is dissolved to 8% wjv protein and applied to a DEAE‐Sephadex® A‐50 or a DEAE‐Sepharose® CL‐6B column. Albumin is further purified by chromatography on SP‐Sephadex C‐50. Gel filtration on Sephadex G‐25 is used for desalting prior to lyophilization. The process has been initially designed for fractionation of 50 litres plasma/week but can be further scaled up to meet considerably higher capaci
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02240.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
6. |
Automated Readout of Sample Identification and Test Results in a BG‐8 Blood Grouping Machine |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 108-115
J. Rechsteiner,
C. J. Benjamin,
R. W. Budding,
Preview
|
PDF (597KB)
|
|
摘要:
Abstract.A fully automated readout unit for the BG‐8 blood‐grouping machine, printing Idee identification numbers with matching ABO grouping and rhesus (D) typing results is described. In 6,737 samples, no incorrect blood group was recorded. Two rhesus (D) positive samples were overlooked, however, and 16.4% of the samples had to be retested because of irregular reaction patterns. Better results are to be expected with properly selected test cells and anti‐D serum.The readout unit is easily operated and is not disturbed by clots. The additional equipment needed replaces the modules which were necessary for recording on filter
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02241.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
7. |
Automated Blood Grouping of Patients and Blood Donors using Groupamatic 360 S and a Separate Mini‐Computer |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 116-123
L. Messeter,
B. Löw,
Preview
|
PDF (542KB)
|
|
摘要:
Abstract.An automated blood‐grouping system for all kinds of blood samples is described. The system is built upon Groupamatic 360 S and a separate mini‐computer. Both the laboratory and the clerical work is automated. Blood group replies are given on coloured punch cards in the Scandinavian blood group colours. Lists of different groups of samples can be compiled. After 1 year of routine use, the refusal rate is about 5%. The system is reliable and rapid, and permits saving, both of manpower and reage
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02242.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
8. |
Absorption Tests on Cold Lymphocytotoxins |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 124-128
S. Mayer,
M. M. Tongio,
Preview
|
PDF (304KB)
|
|
摘要:
Abstract.Tests were carried out to absorb cold lymphocytotoxic antibodies on different types of cells. These included lymphocytes and neuraminidase‐treated lymphocytes from healthy donors, thymocytes from children undergoing open heart surgery, fetal thymocytes, human brain and cultured lymphocytes. The results showed these antibodies to be absorbed on some types of cells and eluted from others. The best absorption was obtained with fetal thymocytes and brain tissu
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02243.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
9. |
Erratum |
|
Vox Sanguinis,
Volume 33,
Issue 2,
1977,
Page 128-128
Preview
|
PDF (60KB)
|
|
ISSN:0042-9007
DOI:10.1111/j.1423-0410.1977.tb02244.x
出版商:Blackwell Publishing Ltd
年代:1977
数据来源: WILEY
|
|