1. |
The Computer in the Closet |
|
Journal of Histotechnology,
Volume 5,
Issue 1,
1982,
Page 9-10
KoskiJohn P.,
Preview
|
PDF (143KB)
|
|
ISSN:0147-8885
DOI:10.1179/his.1982.5.1.9
出版商:Taylor&Francis
年代:1982
数据来源: Taylor
|
2. |
Letter to the Editor |
|
Journal of Histotechnology,
Volume 5,
Issue 1,
1982,
Page 10-10
Preview
|
PDF (77KB)
|
|
ISSN:0147-8885
DOI:10.1179/his.1982.5.1.10
出版商:Taylor&Francis
年代:1982
数据来源: Taylor
|
3. |
Immunoperoxidase Localization of Morphine in the Rat Basal Ganglia |
|
Journal of Histotechnology,
Volume 5,
Issue 1,
1982,
Page 12-14
BarileFrank,
TrombettaLouis D.,
Preview
|
PDF (383KB)
|
|
摘要:
AbstractA procedure has been developed for the immunohistochemical localization of morphine in the rat basal ganglia. Corpora striata of Sprague-Dawley rats, treated with morphine sulfate subcutaneously, were removed and quick frozen in isopentane/liquid nitrogen. Fiveμm sections were reacted with various dilutions of goat anti-morphine serum (IgG), rabbit anti-sheep and rabbit anti-goat peroxidase-labeled IgG, diaminobenzidine and counterstained with methyl green. Light microscopic presence of dark brown reaction product indicated positive staining. Diffuse and particulate cytoplasmic and plasmalemmal staining were observed. Nonspecific background staining was substantially eliminated by adsorbing the morphine antiserum with lyophilized rat brain followed by DEAE-cellulose chromatography prior to the immune reactions. The technique utilizes a two-stage conjugation reaction employing peroxidaselabeled immunoglobulin.
ISSN:0147-8885
DOI:10.1179/his.1982.5.1.12
出版商:Taylor&Francis
年代:1982
数据来源: Taylor
|
4. |
Book Reviews |
|
Journal of Histotechnology,
Volume 5,
Issue 1,
1982,
Page 17-18
Preview
|
PDF (166KB)
|
|
ISSN:0147-8885
DOI:10.1179/his.1982.5.1.17
出版商:Taylor&Francis
年代:1982
数据来源: Taylor
|
5. |
A Method for Measuring Clearance Range Between Microtome Knife and Paraffin Block |
|
Journal of Histotechnology,
Volume 5,
Issue 1,
1982,
Page 23-25
CohenBonnie M.,
Preview
|
PDF (179KB)
|
|
摘要:
AbstractWith the aid of a Craftsman Universal Protractor Plumb and Level,1a method for measuring the clearance angle range between microtome knife and paraffin block has been devised. With this method the clearance angle range desired is reproducible from one microtome to another and easily adjusted as necessary during cuting.
ISSN:0147-8885
DOI:10.1179/his.1982.5.1.23
出版商:Taylor&Francis
年代:1982
数据来源: Taylor
|
6. |
Tissue and Organ Culture Studies of Cartilage |
|
Journal of Histotechnology,
Volume 5,
Issue 1,
1982,
Page 29-32
GetzyLee L.,
MalemudCharles J.,
Preview
|
PDF (506KB)
|
|
ISSN:0147-8885
DOI:10.1179/his.1982.5.1.29
出版商:Taylor&Francis
年代:1982
数据来源: Taylor
|
7. |
Current Concepts in Diagnostic Histopathology: Immunohistologic Methods and Their Application in Diagnostic Histopathology |
|
Journal of Histotechnology,
Volume 5,
Issue 1,
1982,
Page 35-40
EliasJules M.,
Preview
|
PDF (451KB)
|
|
ISSN:0147-8885
DOI:10.1179/his.1982.5.1.35
出版商:Taylor&Francis
年代:1982
数据来源: Taylor
|
8. |
Society Officers |
|
Journal of Histotechnology,
Volume 5,
Issue 1,
1982,
Page 47-47
Preview
|
PDF (58KB)
|
|
ISSN:0147-8885
DOI:10.1179/his.1982.5.1.47
出版商:Taylor&Francis
年代:1982
数据来源: Taylor
|