1. |
The Centro Sperimentale Metallurgico CSM SpA in Rome |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 543-545
Preview
|
PDF (604KB)
|
|
ISSN:0003-8962
DOI:10.1002/srin.198500684
出版商:Wiley
年代:2016
数据来源: WILEY
|
2. |
ECSC announcements |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 546-546
Preview
|
PDF (114KB)
|
|
ISSN:0003-8962
DOI:10.1002/srin.198500685
出版商:Wiley
年代:2016
数据来源: WILEY
|
3. |
Hot metal flow in a blast furnace hearth – model tests |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 547-551
Karl‐Heinz Peters,
Heinrich‐Wilhelm Gudenau,
Gunnar Still,
Preview
|
PDF (468KB)
|
|
摘要:
Very recent operation measurements and test bore holes made in solidified blast furnace hearths indicate the presence of a downward‐arching, convex‐shaped coke zone in blast furnace hearths. By means of model tests using a two‐dimensional electric simulator that stands out against previously used models because of its easy handling, simulations were made of the effects of this convex‐shaped coke zone base on hot metal flows in blast furnace hearths. It was possible to detect a hot metal flow that has a different path to those known so far in the hearth bath and runs radially along the periphery of the hearth bottom to the tap hole. This flow path occurs when the coke zone rests partially on the hearth bottom centre. It causes increased stress on the refractory lining at the junction between the hearth bottom and hearth wall and in the long run can lead to extensive disintegration of the lining in these areas.When a coke zone with a convex base floats in the hearth bath, compared with a flat base, it produces no appreciable changes in the hot metal flows.As further tests showed, it is only possible to a limited extent to directly influence the hot metal flows by applying such operational measures as longer tap holes and a lower bath level.
ISSN:0003-8962
DOI:10.1002/srin.198500686
出版商:Wiley
年代:2016
数据来源: WILEY
|
4. |
ECSC announcements |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 552-552
Preview
|
PDF (116KB)
|
|
ISSN:0003-8962
DOI:10.1002/srin.198500687
出版商:Wiley
年代:2016
数据来源: WILEY
|
5. |
Darstellung komplexer Betriebsschlacken des LD‐Verfahrens im Quasidreistoffsystem |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 553-558
Eberhard Schürmann,
Karl‐Heinz Obst,
Ludwig Fiege,
Heinz‐Peter Kaiser,
Preview
|
PDF (522KB)
|
|
摘要:
Aus der Darstellung der Schlackenzusammensetzungen im Quasidreistoffsystemist die Lage der Schlacken zur Kalksättigungslinie deutlich zu erkennen. Die Sublanzenschlacken lassen den Schlackenweg während der letzten Blasminuten erkennen, durch Bodenspülung und Nachspülen wird eine geringe Annäherung an die Kalksättigungslinie erreicht. Aus der Lage der Schlacken im Quasidreistoffsystemläßt sich der Einfluß der Temperatur auf den Verlauf der Kalksättigung entlang unterschiedlicherT‐X‐Schnitte bestimmen.
ISSN:0003-8962
DOI:10.1002/srin.198500688
出版商:Wiley
年代:2016
数据来源: WILEY
|
6. |
Influence of non‐uniform material properties and water cooling on current density and temperature profiles in arc furnace electrodes |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 559-564
Klaus Bullerschen,
Herbert Wilhelmi,
Wolfgang Wimmer,
Preview
|
PDF (620KB)
|
|
摘要:
The influence of the simplifying assumption of constant electrical conductivity on the modelling of current density and temperature profiles in arc furnace electrodes is investigated in comparison with calculations taking into account the complete interdependence of electrical and thermal effects. With respect to the accuracy of the calculated values for UHP arc furnace electrodes it is shown that the classical theory for the skin effect using the approximation of constant electrical conductivity is inferior to an exact numerical evaluation, especially concerning the current distribution. A two‐dimensional thermal analysis is performed for combination electrodes consisting of a water cooling shank and a graphite wearing part, in order to demonstrate the cooling effect for the reduction of graphite consumption. In the electrodes considered here, the cooled region in the wearing part covers an axial distance in the order of one electrode diameter.
ISSN:0003-8962
DOI:10.1002/srin.198500689
出版商:Wiley
年代:2016
数据来源: WILEY
|
7. |
Description of an experimental/theoretical method to determine the metal flow during steady‐state forming processes |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 565-570
Rainer Herbertz,
Hans‐Peter Kallabis,
Reiner Kopp,
Paul‐Josef Mauk,
Helmut Osterburg,
Preview
|
PDF (613KB)
|
|
摘要:
A new method to determine the metal flow within the deformation zone of stationary deformation processes is introduced. Specimen preparation and analysis are explained for hot rolling of bars and structural shapes.Theoretical fundamentals concerning material velocity in the deformation zone are defined and specific equations are deduced.The method is applied to bars and structural steel and its results are discussed, demonstrating possible problems, inaccuracies and limits.
ISSN:0003-8962
DOI:10.1002/srin.198500690
出版商:Wiley
年代:2016
数据来源: WILEY
|
8. |
ECSC announcements |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 570-570
Preview
|
PDF (114KB)
|
|
ISSN:0003-8962
DOI:10.1002/srin.198500691
出版商:Wiley
年代:2016
数据来源: WILEY
|
9. |
Ein empirisch‐theoretisches Verfahren zur Berechnung von Verzerrungen und Umformgraden beim Induktivbiegen von Rohren |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 571-574
Rolf Kümmerling,
Preview
|
PDF (348KB)
|
|
摘要:
Am Beispiel des Biegens mit induktiver Erwärmung wird eine empirisch‐theoretische Methode zur Berechnung der Verzerrungen im Rohr vorgestellt. Die Empirie wird benutzt, um die Geometrie des Rohres nach dem Biegen zu beschreiben. Über theoretische Ansätze werden hieraus dann die Dehnungen berechnet.Ein Vergleich von Messungen mit gerechneten Werten ergab, daß der theoretische Teil die auftretenden Längsdehnungen bei gegebener Geometrie gut wiedergibt. Die Geometrie selbst wird durch die Empirie nur dann ausreichend gut beschrieben, wenn für die Einflußgröße Vorschubkraft der jeweilige Meßwert und nicht der theoretische Wert eingesetzt wird. Dies heißt, daß die in dieser Größe enthaltenen Einflußgrößen wie Temperatur, Materialeigenschaften etc. gesondert zu berücksichtigen sind.
ISSN:0003-8962
DOI:10.1002/srin.198500692
出版商:Wiley
年代:2016
数据来源: WILEY
|
10. |
ECSC announcements |
|
Archiv für das Eisenhüttenwesen,
Volume 56,
Issue 11,
2016,
Page 574-574
Preview
|
PDF (92KB)
|
|
ISSN:0003-8962
DOI:10.1002/srin.198500693
出版商:Wiley
年代:2016
数据来源: WILEY
|