1. |
THE STEREOSCOPIC SENSE OF ORDER—A CLASSIFICATION OF STEREOGRAMS |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 83-95
T. Shipley,
M. Hyson,
Preview
|
PDF (630KB)
|
|
摘要:
Stereograms are classified into those with constant disparity and those with continuously variable disparity. The first class gives rise to the perception of a displaced flat plane, the second gives rise to the perception of a tilting surface. The former class includes most of the stereograms studied to date: the latter includes those derived from considerations of aniseikonia. Certain ramifications of this classification arc noted. as well as the limits it sets on possible brain models of binocular stereoscopic function.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
2. |
THE F‐B CORNEA TONOMETER CALIBRATION DEVICE |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 96-104
Allan Freid,
Roy Brandreth,
Preview
|
PDF (341KB)
|
|
摘要:
An artificial cornea has been designed and produced which can be used to calibrate and evaluate and control the tonogram producing qualities of Mackay-Marg tonometers. The device has also shown promise of utilization with other types of tonometers.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
3. |
AN AUTOMATIC CASE‐HISTORY TAKER FOR EYE EXAMINATION |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 105-112
Elwin Marg,
Crossman P.,
Goodeve H.,
Preview
|
PDF (316KB)
|
|
摘要:
The paper describes an automatic system for conducting the case history interview, a necessary part of an eye examination. Questions are asked of the patient over a loudspeaker from a pre-recorded audio magnetic tape, played on a random-access tape deck controlled by a small, general-purpose digital computer. The patient responds to these questions through one of three pushbuttons labeled YES, DOUBTFUL, and NO. Hardware and software design is presented in detail, together with results of clinical trials employing a total of 80 patients. Results show reliable identification of primary and secondary complaints, the latter being found more reliably than in normal interviews of the same patients.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
4. |
PHOTOGRAPHIC RECORDING OF THE RETINOSCOPIC REFLEX |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 113-118
Christian,
Preview
|
PDF (189KB)
|
|
摘要:
Considerations leading to the design and construction of a prototype instrument suitable for retinoscopic photography are discussed, including an outline of its essential features.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
5. |
TELEVISION RETINOSCOPY — A NEW TEACHING AND RESEARCH TOOL |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 119-121
Dennis,
Bader Dennis,
Preview
|
PDF (135KB)
|
|
摘要:
The methodology and instrumentation for producing a videotape recording of the retinoscopic reflex as seen in different refractive conditions is discussed, along with advantages, disadvantages, and implications for future research in this area. There are no reports in the literature of filming the reflex.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
6. |
THE OPHTHALMETRON, PRINCIPLES AND OPERATION |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 122-127
Henry,
Knoll Richard,
Preview
|
PDF (243KB)
|
|
摘要:
The Ophthalmetron is an electro-optical instrument designed to determine the refractive state of an eye. The output is in the form of a graph which gives the refractive state for each meridian. The principle upon which its operation is based is described, and illustrations of its components and graphical output arc shown.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
7. |
A STUDY INVOLVING GLASS SAFETY LENSES |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 128-135
Margaret,
Dowaliby John,
Griffin Bert,
Palmer Lorraine,
Preview
|
PDF (305KB)
|
|
摘要:
Ninety-six dress hardened glass lenses were supplied by reputable, high quality optical laboratories in the Los Angeles area. These lenses were given the standard drop-ball test conforming to the Z.80.1 specifications. Thirty of the lenses broke upon testing. The analysis of breakage trends includes the results of a computer determined matrix correlation resulting in a factor analysts.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
8. |
NEW MEMBER |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 136-136
Preview
|
PDF (34KB)
|
|
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
9. |
AMERICAN ACADEMY OF OPTOMETRY |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 137-172
&NA;,
Preview
|
PDF (1316KB)
|
|
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
10. |
EDITORS AND STAFF |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 2,
1972,
Page 173-175
Preview
|
PDF (154KB)
|
|
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|