1. |
VISUO‐SENSORY DEVELOPMENT OF THE CHILD |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 991-1001
George Amigo,
Preview
|
PDF (455KB)
|
|
摘要:
This paper reviews the development of visual function from pre-parturition to the time when functional maturity is reached. The discovery of new and ingenious methods for assessing visual function during the past two decades has enabled researchers to up-date knowledge about visual functional capability. The visuo-sensory apparatus of the human infant has been shown to be much more advanced at birth than was formerly believed, and it attains near-normal capacity much earlier than investigators prior to 1950 believed.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
2. |
DIURNAL CONSTANCY OF CORNEAL CURVATURE |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1002-1004
Roy Rengstorff,
Preview
|
PDF (119KB)
|
|
摘要:
The corneal curvature of four subjects was measured at 7 a.m., 11 a.m., 3 p.m., and 11 p.m. for three consecutive days. No pattern of diurnal variations was found, in sharp distinction to the changes occurring with contact lens wearers.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
3. |
ARRHENIUS PLOTS OF HUMAN AQUEOUS FLOW RATES |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1005-1007
J. Daubs,
Preview
|
PDF (147KB)
|
|
摘要:
Summated aqueous flow rates, estimated from tonometric data. in chronostatically synchronized human subjects were found to be temperature dependent and to conform to the Arrhenius equation.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
4. |
VISION SCREENING IN NURSING AND RETIREMENT HOMES |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1008-1010
Bert Corwin,
Preview
|
PDF (149KB)
|
|
摘要:
This is a report of a joint project in South Dakota. by the Association for the Blind, the Lions Sight and Service Foundation of South Dakota. Inc., the South Dakota Service to the Visually Impaired, and the South Dakota Optometric Association. The project was funded through grant #3.69.02 from Title III of the Older Americans Act of 1965. A total of 4383 residents in 154 homes were screened. Thirty-eight percent were found to be in need of additional visual care.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
5. |
CEREBRAL PALSY VISION SCREENING |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1011-1014
George Lo Cascio,
Preview
|
PDF (125KB)
|
|
摘要:
A comprehensive preschool-age vision screening program is applied to students with cerebral palsy. Based upon actual test results on a selected number of afflicted children. various tests are evaluated. These include visual acuity, fusion, squint, refractive error, and motility. Data are compared to the normal population. Techniques are outlined, results are summarized, and conclusions are made relative to the value of the tests and program.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
6. |
OPTOMETRY'S IMAGE AND ROLE |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1015-1027
S. Bartley,
Preview
|
PDF (567KB)
|
|
摘要:
This is a lecture given to memorialize the series of achievements of The Indians Optometric Association, to indicate some features of professionalism in general, and to discuss the role of optometry—particularly regarding such things as reading disability. The fact that optometery deals with vision as a performance of the total person is stressed.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
7. |
A FAST, ACCURATE MONOCHROMATIC LIGHT STIMULUS GENERATOR |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1028-1029
Theodore Cohn,
Preview
|
PDF (100KB)
|
|
摘要:
The light emitting diode, in conjunction with a feedback control circuit, can be used as a light stimulus generator characterized by good speed. small size, and minimal power supply equipments.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
8. |
FRESNEL LENSES TO CORRECT TWENTY‐FOUR DIOPTERS OF MYOPIA |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1030-1031
Sheldon Wechsler,
Barry weisman,
Preview
|
PDF (107KB)
|
|
摘要:
Fresnel lenses have been used to correct various refractive errors. This paper reports one instance of the successful use of Fresnel lenses to correct high myopia. Although visual acuity was decreased visual performance and comfort were enhanced.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
9. |
A MODEL FOR DEMONSTRATING OCULAR REFRACTION |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1032-1034
Tom Mihok,
William Rosenblum,
Preview
|
PDF (112KB)
|
|
摘要:
A method of constructing a model eye composed of a corneal lens and a crystalline lens contained in aqucous solution is demonstrated, By use of laser illumination, one is able to construct a bundle of rays whose path clearly demonstrates the nature of ocular refraction.
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|
10. |
1972 PRESIDENT'S REPORT TO THE ACADEMY |
|
American Journal of Optometry and Archives of American Academy of Optometry,
Volume 49,
Issue 12,
1972,
Page 1035-1039
Preview
|
PDF (186KB)
|
|
ISSN:0002-9408
出版商:OVID
年代:1972
数据来源: OVID
|