11. |
Myocardial ischemia in a patient with anomalous origin of the left main coronary artery |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 48-50
Abdulmassih S. Iskandrian,
A‐Hamid Hakki,
Charles E. Bemis,
Preview
|
PDF (224KB)
|
|
ISSN:0098-6569
DOI:10.1002/ccd.1810120112
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
12. |
Right ventricular inflow and outflow obstruction due to adrenal cell carcinoma |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 51-54
Brian W. Carlin,
Sinda B. Dianzumba,
Christopher Wendel,
Claude R. Joyner,
Preview
|
PDF (315KB)
|
|
摘要:
AbstractA 48‐year‐old man with surgically removed adrenal cell carcinoma presented with shortness of breath and fatigue. Physical examination revealed neck vein distention and a new systolic murmur. Echocardiography showed a right ventricular mass causing inflow and outflow tract obstruction. These findings were confirmed at surg
ISSN:0098-6569
DOI:10.1002/ccd.1810120113
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
13. |
Fluoroscopic diagnosis of stuck tricuspid valve |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 55-56
M. Y. Flugelman,
B. S. Lewis,
E. Milgalter,
Y. Hasin,
M. S. Gotsman,
Preview
|
PDF (152KB)
|
|
ISSN:0098-6569
DOI:10.1002/ccd.1810120114
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
14. |
Angioplasty at coronary bifurcations: Single‐guide, two‐wire technique |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 57-63
Stephen N. Oesterle,
Bruce J. McAuley,
Maurice Buchbinder,
John B. Simpson,
Preview
|
PDF (454KB)
|
|
摘要:
AbstractA technique is described for angioplasty at coronary bifurcations. This simple approach utilizes a single guiding catheter, an exchange wire, and a conventional dilatation catheter and guidewire. With this “protective” guidewire technique, side branches at risk from occlusion during dilatation of a primary coronary segment can be protected and dilated secondarily; continual access to the threatened side branch is maintained with a “standby” exchange wire in the branch
ISSN:0098-6569
DOI:10.1002/ccd.1810120115
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
15. |
Use of pulmonary artery pressure and pacing catheter during PTCA |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 64-65
Andrew S. Jacob,
Thomas S. Goldbaum,
Augusto D. Richard,
Joseph Lindsay,
Preview
|
PDF (189KB)
|
|
摘要:
AbstractA balloon‐tipped pacing catheter capable of monitoring pulmonary artery pressure and providing standby right ventricular pacing was used in 20 percutaneous transluminal coronary angioplasties (PTCAs), without complication. The catheter was eily inserted in all cases (mean 85 sec) and achieved satisfactory pacing threshold in 17 patients (mean 7.5 ma). The design of this catheter theoretically reduces the risk of right ventricular perforation and tamponade, which may be increased during PTC
ISSN:0098-6569
DOI:10.1002/ccd.1810120116
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
16. |
A newly designed directionally controlled guidewire |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 66-70
Mark H. Wholey,
Preview
|
PDF (475KB)
|
|
摘要:
AbstractA directionally controlled, 1:1 torque ratio flexible. 035 guidewire has been developed for angioplasty procedures being done in the peripheral, renal, subclavian, and visceral circulation. A torque‐controlling device is incorporated with the wire in order to negotiate the stenotic or ulcerative atherosclerotic site without damage to the intimal plaque. The increased selectivity of the wire has also found application in subselective examinations within the peripheral, visceral, and extracranial circulation. Four designed configurations are describedNow manufactured by Advanced Cardiovascular Systems, Inc., Mountain View, CA
ISSN:0098-6569
DOI:10.1002/ccd.1810120117
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
17. |
Society news |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 71-72
Preview
|
PDF (102KB)
|
|
ISSN:0098-6569
DOI:10.1002/ccd.1810120118
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
18. |
Cardiac tamponade following PTCA |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 73-73
Ming H. Hwang,
G. Martin Mullen,
Zheu En Piao,
Preview
|
PDF (107KB)
|
|
ISSN:0098-6569
DOI:10.1002/ccd.1810120120
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
19. |
Angioplasty guidewire rotator |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page 74-74
David J. G. Fergusson,
Raymond K. Itagaki,
Preview
|
PDF (60KB)
|
|
ISSN:0098-6569
DOI:10.1002/ccd.1810120121
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
20. |
Masthead |
|
Catheterization and Cardiovascular Diagnosis,
Volume 12,
Issue 1,
1986,
Page -
Preview
|
PDF (94KB)
|
|
ISSN:0098-6569
DOI:10.1002/ccd.1810120101
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
|