1. |
The Electroencephalogram in Metabolic/Toxic Coma |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 243-259
YoungG.B.,
LeungL.S.,
CampbellV.,
DeMeloJ.,
SchievenJ.,
TilsworthR.,
Preview
|
PDF (7454KB)
|
|
摘要:
ABSTRACT.Because of the EEG's sensitivity to brain dysfunction, it lends itself to the examination of the following aspects of coma: the severity and course (improvement or worsening with time) of brain dysfunction, the diagnosis of certain conditions, and the prognosis (especially in conditions which produce permanent structural damage and death of cortical neurons). It is very important to perform serial EEGs to confirm the stability of the pattern and to note evolutionary changes. Although limited, the“anesthesia model”helps conceptually in dealing with a large variety of conditions which produce altered consciousness.
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080417
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
2. |
The Practical Guide to Digital EEG |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 260-289
GorneyDavid S.,
Preview
|
PDF (13422KB)
|
|
摘要:
ABSTRACT.During the past ten years, computer technology has made its way into many facets of our lives. Until recently, however, computer technology had managed to elude the practice of clinical EEG. As instrument manufacturers increasingly use computerized systems and modular software package designs in their new product lines, the specialty of EEG is going to experience many benefits not offered by conventional EEG instruments. This paper addresses the basic concepts of digital EEG technology and the differences between digital and conventional instrumentation.
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080418
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
3. |
Seizure Detection by Fractal Dimensions Measurement in Long-Term Automated Video-EEG Monitoring: A Preliminary Report |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 290-294
TheodoreHerbert R.,
HaasLindsay F.,
WilkinsonValerie A.,
Preview
|
PDF (1908KB)
|
|
摘要:
ABSTRACT.A simple introduction to the concept of fractal dimensions and their use in EEG long-term video-EEG monitoring is discussed. This method detects primary and secondary generalized seizures and distinguishes them from pseudoseizures and complex partial seizures without secondary generalization and purely artifactual activity. The fractal values of physiological artifacts, e.g., chewing, laughing, are different from those obtained from raw EEG but similar to seizure activity. However, when electrodes became dislodged during a seizure a high fractal dimension in excess of that used to trigger the seizure alarm occurred. Inspection of the video allows ready separation of artifactual activity in a nonseizure situation from that created by generalized seizures.
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080419
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
4. |
Phase-Plane Trajectories of EEG Seizure Patterns in Epilepsy |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 295-307
ColluraThomas F.,
MorrisHarold H.,
BurgessRichard C.,
JacobsErnest C.,
KlemGeorge H.,
Preview
|
PDF (5237KB)
|
|
摘要:
ABSTRACT.We investigated EEG phase-plane trajectories associated with the transition from the interictal state to clinical seizures. Our recordings were taken from scalp and invasive electrodes placed in epilepsy patients undergoing prolonged video/EEG monitoring. We systematically examined trajectories from 60 seizures in an attempt to determine criteria which may be used for classifying interictal and ictal patterns. These phase-plane trajectories emphasize the presence of repetitive waves, and clearly show some phase relationships between EEG channels. It is possible to follow the progress of seizure onset using these trajectories, and to define the time-course of the activity. We have found that phase-plane representations provide a different set of criteria for classifying and grouping EEG signals.
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080420
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
5. |
Technical Tips: Evoked Potential Intraoperative Monitoring: Troubleshooting |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 308-317
HaisleyLinda,
Preview
|
PDF (3933KB)
|
|
摘要:
ABSTRACT.There are numerous factors in the operating room that can cause changes and/or artifacts while monitoring somatosensory evoked responses (Chiappa 1983, Nuwer 1986, York 1987). Drugs, anesthetic agents, irrigation, manipulation of the spinal column, changes in the patient's blood pressure and numerous other electrical equipment in the area can all cause changes in the evoked potentials. It is the responsibility of the EP technologist to determine the possible cause of changes when present. The technologist must know what factors can cause changes in the EPs and how to determine the source of artifact. The surgeon must be notified of any critical changes. Intraoperative monitoring can be less stressful and easier for the technologists involved if they are familiar with the surgical procedures, equipment, and medications.
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080421
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
6. |
Book Reviews |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 318-320
Preview
|
PDF (1638KB)
|
|
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080422
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
7. |
Announcements |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 321-321
Preview
|
PDF (338KB)
|
|
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080423
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
8. |
The American Board of Registration of Electroencephalographic and Evoked Potential Technologists, Inc. |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 326-331
Preview
|
PDF (2366KB)
|
|
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080424
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
9. |
Society Proceedings |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 332-344
Preview
|
PDF (6026KB)
|
|
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080425
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
10. |
Indexes |
|
American Journal of EEG Technology,
Volume 32,
Issue 4,
1992,
Page 345-351
Preview
|
PDF (2356KB)
|
|
ISSN:0002-9238
DOI:10.1080/00029238.1992.11080426
出版商:Taylor&Francis
年代:1992
数据来源: Taylor
|
|