|
1. |
Letters to the editor |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 19-20
Roy A. Filly,
Ernest N. Carlsen,
Robert L. Wilson,
Preview
|
PDF (108KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870040402
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
2. |
Editorial |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 247-248
Preview
|
PDF (136KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870040403
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
3. |
Differences in the attenuation of ultrasound by normal, benign, and malignant breast tissue |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 249-254
C. Calderon,
D. Vilkomerson,
R. Mezrich,
K. F. Etzold,
B. Kingsley,
M. Haskin,
Preview
|
PDF (748KB)
|
|
摘要:
AbstractIn quantitative measurements of the attenuation of ultrasound in 18 samples of variously normal, benign, and malignant breast tissue, we found significantly different ranges of attenuation. As observed in previousin vivostudies, with the exception of medullary carcinoma, malignant tissue produces the most attentuation of ultrasound in the frequency range of 1.5 to 3.0 MHz we employed. The apparatus, measurement method, results, and the possible causes of the differences in attenuation are presented.
ISSN:0091-2751
DOI:10.1002/jcu.1870040404
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
4. |
In vitro gray scale echography of protein‐lipid fluid collections in liver tissue |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 255-258
Jerome J. Cunningham,
Preview
|
PDF (458KB)
|
|
摘要:
AbstractThree types of protein‐lipid fluid collections–homogenized milk, buttermilk, and yogurt –were studied in liver tissue byin vitrogray scale echography. These fluid collections are capable of producing internal echoes, dampened sound transmission, partial acoustic “shadows,” and ill‐defined interfaces with hepatic parenchyma. Such effects may preclude universal detection of purulent hepatic abscesses when they contain similar types of
ISSN:0091-2751
DOI:10.1002/jcu.1870040405
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
5. |
Rapid evaluation of many pulse echo system characteristics by use of a triggered pulse burst generator with exponential decay |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 259-263
Paul L. Carson,
Preview
|
PDF (595KB)
|
|
摘要:
AbstractA pulse burst generator is utilized in which the pulses are triggered by the transmitter pulse of the ultrasound system being tested. The pulses are spaced the equivalent of every 2 mm in the body, and their amplitude decays with 0, 1.25, or 2.5 dB/cm over greater than a 50 dB dynamic range. By replacing the ultrasound transducer with the pulse generator, one can record quite easily the accuracy of depth gain compensation (DGC) and of distance measurements in A mode and B mode. If the DGC on the ultrasound unit can be turned to zero, the unit's A mode display characteristic and B mode gray scale curve can be determined rapidly and the receiver gain control or attenuator can be calibrated. Measurement of a receiver signal‐to‐noise ratio is possible, and more quantitative imaging should be facilitated as w
ISSN:0091-2751
DOI:10.1002/jcu.1870040406
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
6. |
Ultrasonic diagnosis of liver metastases |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 265-268
Colin R. McArdle,
Preview
|
PDF (522KB)
|
|
摘要:
AbstractTwenty‐one patients were investigated with ultrasound for the diagnosis of liver metastases. The most common specific appearnces of liver metastases encountered in this series were echogenic nodules and transsonic areas within an echogenic parenchyma. Nonspecific signs include hepatomegaly, distortion of the hepatic outline and alteration of the normal liver architecture. The results of this study suggest that the accuracy of this method of identifying liver metastases may be hig
ISSN:0091-2751
DOI:10.1002/jcu.1870040407
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
7. |
Ultrasonic evaluation of intrathoracic masses |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 269-273
Alan H. Wolson,
Preview
|
PDF (772KB)
|
|
摘要:
AbstractB mode ultrasound can be used to evaluate intrathoracic masses that contact the chest wall. It provides a noninvasive technique to distinguish cystic from solid lesions and to assess the internal structure. Four cases are reported in which this procedure was used to provide diagnostic information.
ISSN:0091-2751
DOI:10.1002/jcu.1870040408
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
8. |
Pulsed doppler ultrasound detection of flow disturbances in arteriosclerosis |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 275-282
W. Robert Felix,
Bernard Sigel,
Robert J. Gibson,
Jimmie Williams,
George L. Popky,
Annette L. Edelstein,
Jeffrey R. Justin,
Preview
|
PDF (1080KB)
|
|
摘要:
AbstractPulsed Doppler ultrasound blood flow detection has been used in a noninvasive manner to detect arterial abnormalities associated with arteriosclerosis. Sound spectrograms of ultrasound signals obtained fromin uitroand animal studies in which flow was disturbed by obstacles placed in the flow stream showed a different distribution of energy over frequency than signals obtained from studies with no flow disturbances. Similar findings were seen clinically. A technique has been developed which can detect disturbed flow patterns resulting from partial occlusion in important superficial arteries (e.g. femoral and carotid) up to 15 cm distal to localized arterial wall abnormalities. Thirty‐five arterial examinations of normal and arteriographically abnormal arteries in 12 patients revealed a sensitivity of 83 percent and a specificity of 61 percent. This study suggests that pulsed Doppler ultrasound may be useful as a screening technique for detection of arteriosclerotic lesions in major superficial arterie
ISSN:0091-2751
DOI:10.1002/jcu.1870040409
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
9. |
Anterior position of the lower pole of the right kidney: Potential confusion with right upper quadrant mass |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 283-285
Robert L. Bree,
Preview
|
PDF (440KB)
|
|
摘要:
AbstractA group of patients with anterior position of the lower pole of the right kidney were examined with ultrasound to evaluate a palpable right upper quadrant mass. After it was determined, with the use of ultrasound, that the palpable mass represented the kidney, no further evaluations were necessary. This appearance is seen fairly often in normal individuals and should be considered a normal variant. The possible anatomic explanation for this appearance is discussed.
ISSN:0091-2751
DOI:10.1002/jcu.1870040410
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
10. |
Demonstration of left ventricular thrombus by conventional echocardiography |
|
Journal of Clinical Ultrasound,
Volume 4,
Issue 4,
1976,
Page 287-288
John H. Horgan,
Fergus O'M Shiel,
Alice C. Goodman,
Preview
|
PDF (266KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870040411
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1976
数据来源: WILEY
|
|