|
1. |
Anthony M. Vintzileos, MD Fetus and placenta area editor |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 487-487
Russell L. Deter,
Preview
|
PDF (43KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870210802
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
2. |
Breast masses with mixed cystic‐solid sonographic appearance |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 489-495
Liria Mariko Omori,
Naofumi Hisa,
Kiyoshi Ohkuma,
Yuji Fujikura,
Kyoichi Hiramatsu,
Kouji Enomoto,
Tadashi Ikeda,
Makio Mukai,
Preview
|
PDF (783KB)
|
|
摘要:
AbstractRetrospective analysis was performed for 56 breast masses with mixed cystic and solid sonographic patterns encountered in the last 5 years at Keio University Hospital, with the objective of elucidating their significance. The lesions were classified into two major groups: tumor with cyst (TWC—solid mass with cystic component) and intracystic tumor (ICT—cystic mass with solid component). According to the pathological diagnosis, 57% were benign and 43% were malignant. Fifty eight percent of malignant lesions were shown to have a TWC pattern and 42% an ICT pattern. Among benign lesions, 66% were shown to be TWC and 34% ICT. In malignant tumors, 96% of the cases showed irregular shape and heterogeneous internal content. Even in benign lesions, a high incidence of irregular shape and rough border was found, although the predominant internal echo texture was homogeneous, and threedimensional (3‐D) contour was not clear. In conclusion, we observed that in the TWC group, the lack of a defined 3‐D contour is the most important criterion, and tumors with multiples cysts tend to be benign. © 1993 John Wiley&S
ISSN:0091-2751
DOI:10.1002/jcu.1870210803
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
3. |
Ultrasound‐guided percutaneous galactography |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 497-502
Tarja Rissanen,
Tapani Typpö,
Tapani Tikkakoski,
Jarmo Turunen,
Timo Myllymäki,
Ilkka Suramo,
Preview
|
PDF (624KB)
|
|
摘要:
AbstractWe present a new percutaneous ultrasound‐guided galactography technique that may be used in patients in whom the conventional technique fails and breast ultrasonography shows dilated ducts. © 1993 John Wiley&Sons, I
ISSN:0091-2751
DOI:10.1002/jcu.1870210804
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
4. |
A modified transvaginal sonographic technique for better ovarian evaluation |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 503-505
Joseph Pardo,
Boris Kaplan,
Carlos Rosenberg,
Yardena Ovadia,
Alexander Neri,
Preview
|
PDF (279KB)
|
|
摘要:
AbstractSonographic evaluation of the pelvis of postmenopausal women is not complete until both ovaries are scanned. Transvaginal sonographic examination combined with transabdominal screening is diagnostic in 85% of cases. Transvaginal examination performed with a partially full bladder significantly increased ovarian detection to 93.5% (p<0.05). © 1993 John Wiley&Sons, Inc
ISSN:0091-2751
DOI:10.1002/jcu.1870210805
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
5. |
Effect of variations of heart rate within the normal range on renal artery Doppler indices in nonpregnant and pregnant women |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 507-510
Marius Kublickas,
Ivar Randmaa,
Nils‐Olov Lunell,
Magnus Westgren,
Preview
|
PDF (322KB)
|
|
摘要:
AbstractThe effect of heart rate on Doppler indices in the renal artery was studied in 21 nonpregnant, 17 normal and 27 preeclamptic pregnant patients. The central hemodynamics was evaluated by Doppler ultrasound in all pregnant women. The study demonstrated no influence of heart rate on renal artery Doppler indices. Central hemodynamic parameters, such as cardiac output, stroke volume, mean arterial pressure and total systemic resistance did not change with increasing heart rate. We do not recommend any correction of the renal artery Doppler indices for heart rate in the range considered clinically normal (60 to 95 beats/min). Above or below this range further investigations are required to determine if corrections would be necessary. © 1993 John Wiley&Sons, Inc
ISSN:0091-2751
DOI:10.1002/jcu.1870210806
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
6. |
The management of ovarian cysts by sono‐guided transvaginal cyst aspiration |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 511-514
Chyi‐Long Lee,
Ying‐Ming Lai,
Shiuh‐Yang Chang,
Ming‐Yang Chang,
Swei Shueh,
Yung‐Kwei Soong,
Preview
|
PDF (365KB)
|
|
摘要:
AbstractNineteen transvaginal, sono‐guided ovarian cyst punctures were performed in 18 patients. These patients, who were high surgical risks, were diagnosed to possess benign ovarian tumors as revealed with sonography. Aspiration curettage of the inner surface of the cyst present during aspiration was also performed to facilitate cytologic diagnosis. The recurrence rate was 11.1%. Sono‐guided transvaginal cyst aspiration has been demonstrated here to be the treatment of choice for dealing with an ovarian cyst in patients at high surgical risk. © 1993 John Wiley&Sons,
ISSN:0091-2751
DOI:10.1002/jcu.1870210807
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
7. |
Ultrasonic fetal weight estimation: Analysis of inter‐ and intra‐observer variability |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 515-519
T. C. Chang,
Stephen C. Robson,
John A. D. Spencer,
Stephen Gallivan,
Preview
|
PDF (398KB)
|
|
摘要:
AbstractStandard ultrasound measurements were performed by two observers in 40 third‐trimester fetuses. Observers were blinded to the results of the meaurements. Estimated fetal weight (EFW) was calculated using two published formulae. The intra‐observer standard deviation for EFW, assessed using one‐way analysis of variance, was<75 g for both observers. The 95% prediction intervals for inter‐observer comparisons of EFW, calculated using the limits of agreement method, were − 187.3 g to 139.8 g, and − 159.9 g to 124.3 g, using the two formulae. The results suggest that measurements of EFW are reproducible. The prediction interval is comparable to the weekly fetal weight increment in normal fetuses. © 1993 John Wil
ISSN:0091-2751
DOI:10.1002/jcu.1870210808
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
8. |
Investigation of abnormal first‐trimester gestations by color Doppler imaging |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 521-526
Richard Jaffe,
Preview
|
PDF (687KB)
|
|
摘要:
AbstractColor Doppler imaging was employed to assess the uteroplacental circulation in abnormal first‐trimester gestations. Included in the study were 40 blighted ova, 35 missed abortions, 10 trophoblastic diseases, and 3 ectopic gestations. Normal gestations served as a control group. Flow was detected more frequently in the blighted ova than in the missed abortions. Flow was detected in all cases of trophoblastic disease and ectopic gestations. Resistance to flow was significantly lower in the trophoblastic group as compared to the other groups. © 1993 John Wiley&Sons, I
ISSN:0091-2751
DOI:10.1002/jcu.1870210809
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
9. |
Budd–Chiari syndrome due to hepatic venous web: Rapid color Doppler diagnosis |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 527-530
Ronald H. Wachsberg,
Laurence Needleman,
Dorian J. Wilson,
Baburao Koneru,
Preview
|
PDF (446KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870210810
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
10. |
Abscess formation in hepatocellular carcinoma: Complications of percutaneous ultrasound‐guided ethanol injection |
|
Journal of Clinical Ultrasound,
Volume 21,
Issue 8,
1993,
Page 531-533
Attilio Solinas,
Gian Severino Erbella,
Eleonora Distrutti,
Corrado Malaspina,
Stefano Fiorucci,
Carlo Clerici,
Gabrio Bassotti,
Antonio Morelli,
Preview
|
PDF (355KB)
|
|
ISSN:0091-2751
DOI:10.1002/jcu.1870210811
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1993
数据来源: WILEY
|
|